Carlos Eduardo García Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carlos Eduardo García Sánchez has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Elizabeth Ayala Blanco
Centro de Investigación en Catálisis (CICAT) –Escuela de Química, Universidad Industrial de Santander, Ciudad Universitaria, Cra. 27 #9, Bucaramanga, Santander, Colombia
3 shared publications Adriana Alexandra Aparicio Ariza
Universidad Industrial de Santander
2 shared publicationsCarlos Mauricio Villamizar Mora
2 shared publications- Cesar Augusto Vargas-Garcia
AGROSAVIA Corporación Colombiana de Investigación Agropecuaria, Mosquera, Colombia
2 shared publications Jonathan Javier Duarte Franco
2 shared publications- Carolina Madolet Pinto
Universidad Industrial de Santander
1 shared publication
Latest Publications
- Open Access
- 20 January 2026
- Published by Sociedade Brasileira de Computação in Journal of the Brazilian Computer Society
- Vol. 32 (1) , 987-1008
Multiphase Measurement, Soft Sensors, Digital Twins: A Systematic Literature Review
Accurate multiphase flow measurement (MPFM) is essential in the oil and gas industry to optimize production, manage reservoirs, and ensure operational safety. Conventional MPFMs, such as Venturi, Coriolis, and positive displacement meters, remain costly and often unreliable under complex flow conditions, limiting their widespread application. In recent years, artificial intelligence (AI), soft sensors, and digital twins have emerged as promising alternatives to improve accuracy, reduce costs, and enable real-time monitoring. This paper presents a systematic review of multiphase measurement technologies, soft sensors, and digital twin applications in hydrocarbon production. Following a structured protocol, we analyze 150 publications from the past decade, addressing three research questions: (i) the current state, challenges, and limitations of MPFM technologies; (ii) the role of soft sensors and data-driven modeling, including statistical methods, machine learning algorithms, and hybrid physics-guided approaches; and (iii) methodological and industrial applications of digital twins in oil and gas operations. The review shows that while traditional MPFMs have reached technological maturity, their costs and operational constraints remain significant barriers. Soft sensors and AI-based methods offer high predictive capacity, although the challenges of interpretability and data quality persist. Digital twins demonstrate potential for integration of realtime monitoring and predictive analytics, but require clearer frameworks distinguishing theoretical models from industrial practice. In general, the findings highlight opportunities to advance multiphase measurement through the integration of AI, soft computing, and digital twin paradigms, and outline directions for future research in this field.
- 20 January 2026
- Published by Sociedade Brasileira de Computação in Journal of the Brazilian Computer Society
- Vol. 32 (1) , 987-1008
Open AccessMultiphase Measurement, Soft Sensors, Digital Twins: A Systematic Literature Review
Accurate multiphase flow measurement (MPFM) is essential in the oil and gas industry to optimize production, manage reservoirs, and ensure operational safety. Conventional MPFMs, such as Venturi, Coriolis, and positive displacement meters, remain costly and often unreliable under complex flow conditions, limiting their widespread application. In recent years, artificial intelligence (AI), soft sensors, and digital twins have emerged as promising alternatives to improve accuracy, reduce costs, and enable real-time monitoring. This paper presents a systematic review of multiphase measurement technologies, soft sensors, and digital twin applications in hydrocarbon production. Following a structured protocol, we analyze 150 publications from the past decade, addressing three research questions: (i) the current state, challenges, and limitations of MPFM technologies; (ii) the role of soft sensors and data-driven modeling, including statistical methods, machine learning algorithms, and hybrid physics-guided approaches; and (iii) methodological and industrial applications of digital twins in oil and gas operations. The review shows that while traditional MPFMs have reached technological maturity, their costs and operational constraints remain significant barriers. Soft sensors and AI-based methods offer high predictive capacity, although the challenges of interpretability and data quality persist. Digital twins demonstrate potential for integration of realtime monitoring and predictive analytics, but require clearer frameworks distinguishing theoretical models from industrial practice. In general, the findings highlight opportunities to advance multiphase measurement through the integration of AI, soft computing, and digital twin paradigms, and outline directions for future research in this field.
- Open Access
- 21 October 2021
- Published by Servicio Nacional de Aprendizaje SENA in Informador Técnico
- Vol. 86 (1)
A review of the different boiler efficiency calculation and modeling methodologies
A review of the different mathematical methodologies for calculating energy efficiency in boilers was carried out in this work, considering both the methods included in standards and the proposals and applications published in research works. The classification was delimited in analytical methods, mechanistic modeling, and empirical modeling; moreover, the main equations for each of the methodologies are presented, which allows building a compilation that is expected to be useful for a first approach to the subject. It is displayed that those mechanistic models are used to evaluate subsystems or specific cases that require a high level of detail, while analytical models are used to make a first approximation to the systems described, and empirical models stand out in terms of their use at the industrial level if there is access to a starting database to adjust them.
- 21 October 2021
- Published by Servicio Nacional de Aprendizaje SENA in Informador Técnico
- Vol. 86 (1)
Open AccessA review of the different boiler efficiency calculation and modeling methodologies
A review of the different mathematical methodologies for calculating energy efficiency in boilers was carried out in this work, considering both the methods included in standards and the proposals and applications published in research works. The classification was delimited in analytical methods, mechanistic modeling, and empirical modeling; moreover, the main equations for each of the methodologies are presented, which allows building a compilation that is expected to be useful for a first approach to the subject. It is displayed that those mechanistic models are used to evaluate subsystems or specific cases that require a high level of detail, while analytical models are used to make a first approximation to the systems described, and empirical models stand out in terms of their use at the industrial level if there is access to a starting database to adjust them.
- 30 September 2021
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 10 (3) , 185-191
Analysis of the mathematical modelling of a static expansion system
Static expansion systems are used to generate pressures in medium and high vacuum and are used in the calibration of absolute pressure meters in these pressure ranges. In the present study, the suitability of different models to represent the final pressures in a static expansion system with two tanks is analysed. It is concluded that the use of the ideal gas model is adequate in most simulated conditions, while the assumption that the residual pressure is zero before expansion presents problems under certain conditions. An uncertainty analysis of the process is carried out, which leads to evidence of the high importance of uncertainty in a first expansion over subsequent expansion processes. Finally, an analysis of the expansion system based on uncertainty is carried out to estimate the effect of the metrological characteristics of the measurements of the input quantities. Said design process can make it possible to determine a set of restrictions on the uncertainties of the input quantities.
- 30 September 2021
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 10 (3) , 185-191
Analysis of the mathematical modelling of a static expansion system
Static expansion systems are used to generate pressures in medium and high vacuum and are used in the calibration of absolute pressure meters in these pressure ranges. In the present study, the suitability of different models to represent the final pressures in a static expansion system with two tanks is analysed. It is concluded that the use of the ideal gas model is adequate in most simulated conditions, while the assumption that the residual pressure is zero before expansion presents problems under certain conditions. An uncertainty analysis of the process is carried out, which leads to evidence of the high importance of uncertainty in a first expansion over subsequent expansion processes. Finally, an analysis of the expansion system based on uncertainty is carried out to estimate the effect of the metrological characteristics of the measurements of the input quantities. Said design process can make it possible to determine a set of restrictions on the uncertainties of the input quantities.
- 21 April 2021
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 28 (3) , 593-604
Characterization of a static expansion standard for calibrating medium and high vacuum pressure gauges
- 21 April 2021
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 28 (3) , 593-604
Characterization of a static expansion standard for calibrating medium and high vacuum pressure gauges
- Open Access
- 22 April 2019
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 97,p. 10-21
Characterization of the urban heat island at Bucaramanga, Colombia, using real-time temperature monitoring
One of the meteorological effects in cities is the increase in local temperature, which is known as urban heat island (UHI). The objective of this study was to detect and quantify the possible UHI in the city of Bucaramanga, Colombia. For this purpose, a real-time temperature measurement network was installed, composed of seven nodes, used to obtain temperature values every minute. Six of the nodes were located in different positions in the city, and the remaining one was used to give the reference measurement. The data collected were processed for elimination of outliers, management of missing data and noise filtering. Analysis of the data allowed detecting differences in the diurnal and nocturnal UHI intensity trends. It was concluded that the UHI intensity during the day varies depending on the Local Climate Zone that represents the location, while the UHI intensity value at night is quite uniform across the city, with a mean value of 1.0 °C. It was also possible to conclude that the magnitude of the daytime UHI is lower in the dry season.
- 22 April 2019
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 97,p. 10-21
Open AccessCharacterization of the urban heat island at Bucaramanga, Colombia, using real-time temperature monitoring
One of the meteorological effects in cities is the increase in local temperature, which is known as urban heat island (UHI). The objective of this study was to detect and quantify the possible UHI in the city of Bucaramanga, Colombia. For this purpose, a real-time temperature measurement network was installed, composed of seven nodes, used to obtain temperature values every minute. Six of the nodes were located in different positions in the city, and the remaining one was used to give the reference measurement. The data collected were processed for elimination of outliers, management of missing data and noise filtering. Analysis of the data allowed detecting differences in the diurnal and nocturnal UHI intensity trends. It was concluded that the UHI intensity during the day varies depending on the Local Climate Zone that represents the location, while the UHI intensity value at night is quite uniform across the city, with a mean value of 1.0 °C. It was also possible to conclude that the magnitude of the daytime UHI is lower in the dry season.
- Open Access
- 18 June 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1044 (1) , 012030
Estimating the uncertainty of the specific surface area of Titanium Oxide Nanotubes calculated from nitrogen adsorption isotherms
- 18 June 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1044 (1) , 012030
Open AccessEstimating the uncertainty of the specific surface area of Titanium Oxide Nanotubes calculated from nitrogen adsorption isotherms
- Open Access
- 24 May 2018
- Published by Universidad Militar Nueva Granada in Ciencia e Ingeniería Neogranadina
- Vol. 28 (2) , 105-120
Cuantificación del efecto de obstrucciones en el área transversal de un túnel de viento sobre los resultados de la calibración de anemómetros
Los instrumentos utilizados para cuantificar magnitudes físicas requieren de calibraciones periódicas, para garantizar la fiabilidad y precisión de sus mediciones. Uno de los métodos de calibración de anemómetros más utilizados consiste en la comparación directa de las lecturas obtenidas por el anemómetro que se desea calibrar y por un instrumento patrón, al exponer ambos instrumentos a un gas a la misma velocidad en el interior de un túnel de viento. La presencia del anemómetro que está siendo calibrado supone una obstrucción que puede distorsionar el perfil de velocidad al interior del túnel de viento. La presente investigación tuvo como objetivo estudiar y modelar el efecto de las obstrucciones causadas por los anemómetros bajo prueba sobre los perfiles de velocidad al interior del túnel de viento WSL 20, de la Corporación CDT de Gas, y así evaluar su influencia sobre los procesos de calibración de instrumentos. Se concluye que el tamaño del anemómetro bajo prueba tiene efecto sobre la velocidad de gas registrada por el instrumento patrón. Los resultados muestran que el tubo de Pitot tipo L no causa una distorsión significativa en el perfil de velocidad, mientras que anemómetros rotativos de diferentes dimensiones ocasionan incrementos en la velocidad registrada por el patrón que varían entre 2,5 % y 5,6 %. Se evidencia la importancia de considerar el efecto de las obstrucciones al interior del túnel de viento y de cuantificar el sesgo que ocasionan, para evitar que este hecho se convierta en un error sistemático dentro del proceso de calibración.
- 24 May 2018
- Published by Universidad Militar Nueva Granada in Ciencia e Ingeniería Neogranadina
- Vol. 28 (2) , 105-120
Open AccessCuantificación del efecto de obstrucciones en el área transversal de un túnel de viento sobre los resultados de la calibración de anemómetros
Los instrumentos utilizados para cuantificar magnitudes físicas requieren de calibraciones periódicas, para garantizar la fiabilidad y precisión de sus mediciones. Uno de los métodos de calibración de anemómetros más utilizados consiste en la comparación directa de las lecturas obtenidas por el anemómetro que se desea calibrar y por un instrumento patrón, al exponer ambos instrumentos a un gas a la misma velocidad en el interior de un túnel de viento. La presencia del anemómetro que está siendo calibrado supone una obstrucción que puede distorsionar el perfil de velocidad al interior del túnel de viento. La presente investigación tuvo como objetivo estudiar y modelar el efecto de las obstrucciones causadas por los anemómetros bajo prueba sobre los perfiles de velocidad al interior del túnel de viento WSL 20, de la Corporación CDT de Gas, y así evaluar su influencia sobre los procesos de calibración de instrumentos. Se concluye que el tamaño del anemómetro bajo prueba tiene efecto sobre la velocidad de gas registrada por el instrumento patrón. Los resultados muestran que el tubo de Pitot tipo L no causa una distorsión significativa en el perfil de velocidad, mientras que anemómetros rotativos de diferentes dimensiones ocasionan incrementos en la velocidad registrada por el patrón que varían entre 2,5 % y 5,6 %. Se evidencia la importancia de considerar el efecto de las obstrucciones al interior del túnel de viento y de cuantificar el sesgo que ocasionan, para evitar que este hecho se convierta en un error sistemático dentro del proceso de calibración.
- 1 April 2018
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 7 (1) , 68
Mathematical analysis of the effect of the constant temperature assumption in the leak test of PTB Testing Instructions, Volume 25
"PTB Testing Instructions, Volume 25: Gas meters – Test rigs with critical nozzles" (PTB 25) includes a detailed description of a test to evaluate the tightness of the rig (leak test). The mathematical modeling of this test assumes that temperature remains constant, and it is established a maximum allowable change of 0.1 K during the test. PTB 25 defines a maximum value of the leak flow rate as criteria for approval of the test.In this work, the effect of the assumption of constant temperature over the leak test result was analyzed. Different processes in which the real leak flow rate was zero and there was a change in the temperature of the system equal to the maximum permissible (according to PTB 25) were simulated, and the leak flow rate calculated by PTB 25’s model was determined. The assumption of constant temperature does not simplifies drastically the mathematical model. It is concluded that PTB 25’s maximum allowable temperature change is too high for most practical situations, leading to errors that exceeds the maximum allowable leakage rate. The factors “test time” and “enclosed volume” have a high effect over the magnitude of the error given by PTB 25’s leak flow rate model.
- 1 April 2018
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 7 (1) , 68
Mathematical analysis of the effect of the constant temperature assumption in the leak test of PTB Testing Instructions, Volume 25
"PTB Testing Instructions, Volume 25: Gas meters – Test rigs with critical nozzles" (PTB 25) includes a detailed description of a test to evaluate the tightness of the rig (leak test). The mathematical modeling of this test assumes that temperature remains constant, and it is established a maximum allowable change of 0.1 K during the test. PTB 25 defines a maximum value of the leak flow rate as criteria for approval of the test.In this work, the effect of the assumption of constant temperature over the leak test result was analyzed. Different processes in which the real leak flow rate was zero and there was a change in the temperature of the system equal to the maximum permissible (according to PTB 25) were simulated, and the leak flow rate calculated by PTB 25’s model was determined. The assumption of constant temperature does not simplifies drastically the mathematical model. It is concluded that PTB 25’s maximum allowable temperature change is too high for most practical situations, leading to errors that exceeds the maximum allowable leakage rate. The factors “test time” and “enclosed volume” have a high effect over the magnitude of the error given by PTB 25’s leak flow rate model.
- Open Access
- 28 December 2016
- Published by Universidad Industrial de Santander in Revista ION
- Vol. 29 (2) , 85-97
Revisión del cálculo de poder calorífico y punto de rocío del gas natural, y de la estimación de sus incertidumbres
Revisión del cálculo de poder calorífico y punto de rocío del gas natural, y de la estimación de sus incertidumbres
- 28 December 2016
- Published by Universidad Industrial de Santander in Revista ION
- Vol. 29 (2) , 85-97
Open AccessRevisión del cálculo de poder calorífico y punto de rocío del gas natural, y de la estimación de sus incertidumbres
Revisión del cálculo de poder calorífico y punto de rocío del gas natural, y de la estimación de sus incertidumbres
- 20 April 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (11) , 1907-1915
Comparison of different methods to estimate the uncertainty in composition measurement by chromatography
Natural gas is a mixture that contains hydrocarbons and other compounds, such as CO2 and N2 . Natural gas composition is commonly measured by gas chromatography, and this measurement is important for the calculation of some thermodynamic properties that determine its commercial value. The estimation of uncertainty in chromatographic measurement is essential for an adequate presentation of the results and a necessary tool for supporting decision making. Various approaches have been proposed for the uncertainty estimation in chromatographic measurement. The present work is an evaluation of three approaches of uncertainty estimation, where two of them (guide to the expression of uncertainty in measurement method and prediction method) were compared with the Monte Carlo method, which has a wider scope of application. The aforementioned methods for uncertainty estimation were applied to gas chromatography assays of three different samples of natural gas. The results indicated that the prediction method and the guide to the expression of uncertainty in measurement method (in the simple version used) are not adequate to calculate the uncertainty in chromatography measurement, because uncertainty estimations obtained by those approaches are in general lower than those given by the Monte Carlo method.
- 20 April 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (11) , 1907-1915
Comparison of different methods to estimate the uncertainty in composition measurement by chromatography
Natural gas is a mixture that contains hydrocarbons and other compounds, such as CO2 and N2 . Natural gas composition is commonly measured by gas chromatography, and this measurement is important for the calculation of some thermodynamic properties that determine its commercial value. The estimation of uncertainty in chromatographic measurement is essential for an adequate presentation of the results and a necessary tool for supporting decision making. Various approaches have been proposed for the uncertainty estimation in chromatographic measurement. The present work is an evaluation of three approaches of uncertainty estimation, where two of them (guide to the expression of uncertainty in measurement method and prediction method) were compared with the Monte Carlo method, which has a wider scope of application. The aforementioned methods for uncertainty estimation were applied to gas chromatography assays of three different samples of natural gas. The results indicated that the prediction method and the guide to the expression of uncertainty in measurement method (in the simple version used) are not adequate to calculate the uncertainty in chromatography measurement, because uncertainty estimations obtained by those approaches are in general lower than those given by the Monte Carlo method.