HBHalil Bozkaya

Halil Bozkaya

*This is an algorithmically generated author record based on publicly available information.

Halil Bozkaya has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Long-term Results of Renal Chimney Grafts In Juxtarenal Abdominal Aortic Aneurysms

    by Ahmet Daylan, Emrah Oğuz, Serkan Ertugay, Halil Bozkaya, Mustafa Parıldar, Hakan Posacıoğlu

  • Open Access

    Kısa Boyunlu Jukstarenal Aort Anevrizmalarının Greft Stent ile Tedavisinde Chimney Tekniğinin Kullanımı: Retrospektif Bir Çalışma

    by Eren İsMai̇lOğlu, Secil Eker, Halil Bozkaya, Emrah Oğuz, Celal Ci̇nAr, Mustafa Parildar, Hakan Posacioğlu, İsMail Oran

    Giriş: Endovasküler tedavi yöntemlerinden biri olan chimney tekniğinin sonuçlarının yüz güldürücü olması, ucuz olması, fenestre stentlere ve hibrid yönteme göre avantajlarının bulunması bu yöntemin daha fazla tercih edilme sebebidir. Amaç: Kısa boyunlu jukstarenal aort anevrizmalarının greft stent ile endovasküler tedavisinde chimney tekniğinin sonuçlarının değerlendirilmesidir. Gereç-Yöntem: Çalışmaya 2008-2013 tarihleri arasında abdominal aort anevrizması nedeniyle girişimsel radyoloji bölümünde chimney tekniği uygulanarak endovasküler greft stent yöntemi ile tedavi edilen; preoperatif ve postoperatif bilgisayarlı tomografi anjiografi görüntüleri dijital radyoloji arşiv sisteminde kayıtlı olan jukstarenal aort anevrizmalı 17 hasta alındı. Hastaların preoperatif ve postoperatif dijital subtraksiyon anjiografi ve BTA görüntüleri retrospektif olarak değerlendirildi. Chimney tekniği kullanımının sonuçları tartışıldı. Bulgular: Çalışmaya alınan 17 hastanın yaş ortalaması 68.94±9.46’dır. Anevrizma etiyolojisinde 14 hastada ateroskleroz, 3 hastada ise vaskülit yer almaktaydı. 4 hastada operasyon öncesi anevrizma rüptürü mevcuttu. Hastaların anevrizma boyun uzunluğu ortalaması 3.02±2.8 mm (0-9 mm), operasyon sonrası takip süresi ortalaması 6.86±4.6 ay (1-16 ay) idi. Preoperatif ve postoperatif 6 ve 12. ay anevrizma çap ortalamaları arasında anlamlı fark bulundu (p<0.05). 17 hastaya planlanan toplam 28 chimney stent girişiminin 2’sinde chimney stentlerin yerleştirilmesi başarısızlıkla sonuçlandı (Başarı oranı %92.86). Başarılı olunan 15 hastanın 9’unda bilateral renal artere, 3’ünde sol renal artere, 2’sinde sağ renal artere, 1’inde SMA’ya chimney stent yerleştirildi. Takipte 3 hastada endoleak (2 hasta Tip IIA, 1 hasta Tip IA), 3 hastada toplam 4 arterde ise tromboz gelişti. Sonuç: Jusktarenal aort anevrizmalı bireylerin endovasküler tedavisinde chimney yönteminin kullanımı başarılı bir yöntemdir


  • Open Access

    Comparison of the multi-epitope recombinant antigen DIPOL and hydatid fluid for the diagnosis of patients with cystic echinococcosis

    by Eylem Akdur Ozturk, Raúl Manzano-Román, Carlos Sánchez-Ovejero, Ayse Caner, Mesude Angın, Cumhur Gunduz, Ülkü Karaman, Nuray Altintas, Halil Bozkaya, Omer Unalp, et al.


  • Comparison of the New Multiepitope Recombinant Peptide Antigen with Cyst Fluid Antigen in the Follow-up of Patients with Cystic Echinococcosis

    by Eylem Akdur Öztürk, Mesut Akıl, Ayşe Caner, Halil Bozkaya, Nazmiye Altıntaş, Ayşegül Ünver

    The follow-up of patients with cystic echinococcosis (CE) offers the opportunity of evaluating the prognosis of the infection as well as detecting relapse. This study aimed to evaluate the performance of the new multiepitope recombinant peptide (recDipol) antigen in the follow-up of CE patients treated by surgery or percutaneous aspiration injection respiration. A total of 137 blood samples from 28 patients were evaluated by IgG-ELISA method using recDipol and hydatid fluid (HF) antigens. The patients were simultaneously checked for recurrence by ultrasonography. The seropositivity rate of the 28 patients varied considerably during the follow-up. When the first blood of the patients was evaluated, 4 (14.28%) were seronegative by HF-ELISA and 9 (32.14%) were recDipol-ELISA. During the entire follow-up, only 1 (3.5%) and 6 (21.4%) patients were seronegative by HF-ELISA and recDipol ELISA, respectively. We found that recDipol did not perform as expected in the follow-up due to the higher number of seronegative patients compared to HF-ELISA in the first blood and during the entire follow-up. Our results suggest that imaging methods are gold standards in the diagnosis and that, in parallel, longer-term patient follow-up is required with recombinant antigens that have an improved diagnostic performance.

  • Open Access

    Böbrek Nakli Sonrası Önemli Bir Komplikasyon: Transplant Renal Arter Stenozu

    by Sevgin Taner, Sebla Güneş, Halil Bozkaya, Mehmet Arda Kılınç, İpEk Kaplan Bulut, Ahmet Keski̇noğlu, Pınar Yazıcı Özkaya, Caner Kabasakal, Bülent Karapinar

    Renal transplantation is a preferred treatment option because of its low long-term mortality and increased quality of life. However, complications after transplantation affect graft and patient survival. Transplant Renal Artery Stenosis (TRAS) is the most common vascular complication following renal transplantation affecting 1-23% of patients. Although it usually causes refractory hypertension, it can also cause graft loss. Although Peripheral Angiography (Digital subtraction angiography) is the gold standard for the diagnosis of TRAS, Doppler USG has become a primary imaging method because it is portable, inexpensive and noninvasive. There are surgical and endoluminal options in the treatment. In this report, a 16-year-old girl who had renal artery stenosis at the 4th month after renal transplantation and underwent percutaneous transluminal balloon angioplasty was reported. She is now in her second year of transplantation without any need for antihypertensive treatment and with preserved graft function.

  • Open Access

    Chimney technique for solitary pelvic kidney

    by Serkan Ertugay, Hakan Posacioglu, Halil Bozkaya, Mustafa Parildar

    The combination of solitary pelvic kidney and abdominal aortic aneurysm is extremely rare. In this report, we present chimney graft implantation in a patient with solitary pelvic kidney. A 63-year-old man had the diagnosis of infrarenal abdominal aortic aneurysm made incidentally. Preoperative computed tomography illustrated a fusiform abdominal aortic aneurysm accompanying a solitary ectopic kidney in the pelvis with aberrant renal artery. A bifurcated endograft was implanted, and a covered stent graft was placed into the renal artery by use of the chimney technique. Good patency of the chimney graft was documented with early postoperative and first month scans. To the best of our knowledge, this is the first report of the chimney technique used in a solitary pelvic kidney.


  • Open Access

    A pilot comparative study between serological and genetic investigations in relationship to clinical outcomes on patients with cystic echinococcosis

    by Nu Altintas, S A Karamil, O Turkum, M Akil, A Sakarya, H Bozkaya, J Šoltys, Na Altintas

    Summary: The aim of this study was to investigate whether Enzyme-Linked Immunosorbent Assays (ELISA) and Western Blotting (WB) methods could contribute to the assessment of clinical outcomes in genotype-defined cystic echinococcosis (CE) patients. Twenty-nine human isolates and blood samples have been taken from patients who underwent surgery or percutaneous aspiration (PAIR) for therapeutic purposes at Ege University and Manisa Celal Bayar University Hospitals. All sera of patients were screened for the presence of E. granulosus IgG antibodies using in-house approved ELISA and WB methods. According to the ELISA results, five patients had high, thirteen patients had medium and eight patients had low specific antibody level response which ranged 1/640 -1/5000. Despite confirmed WB positivity three patients were found to be negative by ELISA. Immunoblot analysis of EgAg showed many protein bands with size of 8, 12, 20, 22, 24, 36, 75 and 90 kDa. Among of them, 8 – 12 kDa bands (90 %), 20 – 22 kDa and 36 kDa bands presented strong reactivity against human serum specimens. No serum samples from healthy control reacted with EgAg. Phylogenetic analysis of resulting COX1 and NAD1sequences has revealed that all patients in our study were infected with the E. granulosus G1-G3 genotype. There was no consistent correlation between results of ELISA and WB, the number or size of cysts and genotype. Our study brings a unique contribution in terms of relationship between serological investigation, disease genotypes and clinical outcomes.


  • Reduced Activity of von Willebrand Factor after Flow-Diverting Stent Implantation for Intracranial Aneurysms: A Link to Acquired von Willebrand Disease?

    by I. Oran, C. Cinar, H. Bozkaya, M. Parildar, S. Duman

    BACKGROUND AND PURPOSE: Vascular devices generating high shear stress can cause type 2A acquired von Willebrand disease, which is characterized by low von Willebrand factor activity accompanied by hemorrhagic complications. The braided mesh structure of flow-diverting stents with a relatively small strut size can create abnormally high shear stress while arterial blood flows through the stent struts into the aneurysm, and flow-diverting stent may be associated with reduced von Willebrand factor activity. MATERIALS AND METHODS: Aneurysmal morphologic parameters and patient data were examined retrospectively among patients who had an unruptured intracranial aneurysm treated with a flow-diverting stent. The RISTOtest (test for whole blood ristocetin-induced platelet aggregation) for von Willebrand factor activity, as well as tests for aspirin and clopidogrel/prasugrel effectiveness, were performed immediately before the endovascular procedure and 24 hours later by multiple electrode aggregometry. RESULTS: A total of 39 patients with 56 aneurysms were recruited, and statistical analyses were performed in 32 patents with 49 aneurysms. Compared with the baseline values, von Willebrand factor activity was reduced in 16 patients but increased in 23 patients. Aneurysmal variables (eg, neck area, volume, volume-to-neck area ratio, size ratio, and morphologic index) clearly distinguished patients with reduced von Willebrand factor activity from those with nonreduced von Willebrand factor activity. The receiver operating characteristic curve showed that the morphologic index and volume had the highest discriminative power, with an area under the curve of 0.99. CONCLUSIONS: In high-volume/large-neck aneurysms, flow-diverting stent implantation can cause reduced von Willebrand factor activity, which may be linked causally to acquired von Willebrand disease.


  • Open Access

    Servikokranial damarlar için dijital subtraksiyon anjiografi ve multislice bilgisayarlı tomografi anjiografi radyasyon dozlarının karşılaştırılması

    by H. İbrahim Özdemi̇r, Celal Çinar, Halil Bozkaya, Selçuk Topal, İsmail Oran

    Aim: In this study our purpose was to compare the digital subtraction angiography (DSA) and computed tomography angiography (CTA) techniques in terms of the superiority of diagnosis and radiation doses. Materials and Methods: Forty-six patients (21 men, 25 women) who were subjected to both digital subtraction angiography (DSA) and computed tomography (CT) neck-brain angiographic examinations between January and December 2014 were screened retrospectively. Radiation dose records taken from the cards provided by DSA and CT devices were reviewed. The total DSA [DSA+ tri-dimension (3D) DSA], DSA, 3D-DSA and CTA dose reports were examined separately. Generated 3D images were evaluated by two radiologists who had experience in neuro radiology and interventional radiology at least for five years. Independent samples test and in dual comparisons the paired samples test, were used for statistical analyses. Results: Comparison made between DSA and CTA radiation doses has found that the total dose of total DSA (DSA+3D DSA) was three times and the DSA doses were two times higher than the CTA dose. There was no statistical difference between 3D DSA and CTA doses. CTA is less sensitive than DSA; four of 68 intracranial aneurisms could not be demonstrated with CTA. The radiation doses received by patients did not change with gender. Conclusion: CTA contains less radiation doses in the diagnosis of intracranial aneurisms, but its sensitivity, however, is lower than DSA.

  • Open Access

    Servikokranial damarlar için dijital subtraksiyon anjiyografi ve multislice bilgisayarlı tomografi: Radyasyon dozlarının karşılaştırılması

    by Halil İbrahim Özdemi̇r, Celal Çinar, Halil Bozkaya, Selçuk Topal, İsmail Oran

    Aim: In this study our purpose was to compare the DSA and CTA techniques in terms of the superiority of diagnosis and radiation doses. Materials and Methods: Forty-six patients (21 men, 25 women) who were subjected to both digital subtraction angiography (DSA) and computed tomography (CT) neck-brain angiographic examination between January 2014 and December of 2014 were screened retrospectively. Radiation dose records taken from the cards provided by DSA and CT devices were reviewed. The total DSA [DSA+ tri-dimension (3D) DSA], DSA, 3D-DSA and computed tomography angiography (CTA) dose reports were examined separately. Generated 3D images were evaluated by two radiologists who had experience in neuro radiology and interventional radiology at least 5 years. Independent-samples test and in dual comparisons the paired samples test, were used for statistical analyses. Results: Comparison made between DSA and CTA radiation doses has found that the total dose of TDSA (DSA+3D DSA) was more than 3 times higher than the CTA dose and the DSA doses were 2 times greater than the CTA dose. There was no statistical difference between 3D DSA and CTA doses. CTA is less sensitive than DSA; four of 68 intracranial aneurisms could not be demonstrated with CTA. The radiation doses received by patients did not change with gender. Conclusion: CTA contains less radiation doses in the diagnosis of intracranial aneurisms, but its sensitivity, however, is lower than DSA.