Liston Matindife
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liston Matindife has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Zenghui Wang
University of South Africa
7 shared publications - Yanxia Sun
Department of Electrical and Electronic Engineering Science, University of Johannesburg, Auckland Park 2006, South Africa
4 shared publications - Destine Mashava
National University of Science and Technology, Zimbabwe
2 shared publications - James Kuria Kimotho
Jomo Kenyatta University of Agriculture and Technology, Kenya
1 shared publication - Kenneth Okello
Jomo Kenyatta University of Agriculture and Technology, Kenya
1 shared publication
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in Preprints.org
A Reduced-Order Proof of Concept for AI-Guided Scenario-Criticality Search and VVUQ in a Battery-Electric Rail Vehicle Cell Digital Twin
The “Daydreaming Factory” is a conceptual framework in which a digital model is used to explore future operating scenarios before they occur. It has not been given a formal mathematical form or an executed demonstration of its central algorithmic claim, that AI-guided search finds reliability-critical scenarios more efficiently than manual or random exploration. This paper gives a reduced-order, single-cell instantiation for a battery-electric rail vehicle (BERV) Li-ion cell, using equivalent-circuit and ageing parameters previously identified from NASA PCoE data. We define a four-dimensional scenario space (current stress, resistive fault, ageing-rate stress, initial state of charge) and a criticality score that includes a battery-management-system (BMS) overcurrent trip, which makes the landscape discontinuous: the worst case lies just below the trip point, not at the corner of the space. Differential evolution (DE) found a score of 7.867 with 1,345 evaluations, matching an exhaustive 390,625-point grid (7.847) at 0.34% of its cost, whereas random search with the same budget reached 7.447 ± 0.178 over ten trials. A coarse-versus-fine time-step check gave perfect rank agreement (Spearman ρ = Kendall τ = 1.000), although this is a weak test. The landscape and its constants are assumptions of this study, and DE was run once. The work is an algorithmic proof of concept, not a validated vehicle-level system.
- 24 November 2026
- Published by MDPI AG in Preprints.org
Open AccessA Reduced-Order Proof of Concept for AI-Guided Scenario-Criticality Search and VVUQ in a Battery-Electric Rail Vehicle Cell Digital Twin
The “Daydreaming Factory” is a conceptual framework in which a digital model is used to explore future operating scenarios before they occur. It has not been given a formal mathematical form or an executed demonstration of its central algorithmic claim, that AI-guided search finds reliability-critical scenarios more efficiently than manual or random exploration. This paper gives a reduced-order, single-cell instantiation for a battery-electric rail vehicle (BERV) Li-ion cell, using equivalent-circuit and ageing parameters previously identified from NASA PCoE data. We define a four-dimensional scenario space (current stress, resistive fault, ageing-rate stress, initial state of charge) and a criticality score that includes a battery-management-system (BMS) overcurrent trip, which makes the landscape discontinuous: the worst case lies just below the trip point, not at the corner of the space. Differential evolution (DE) found a score of 7.867 with 1,345 evaluations, matching an exhaustive 390,625-point grid (7.847) at 0.34% of its cost, whereas random search with the same budget reached 7.447 ± 0.178 over ten trials. A coarse-versus-fine time-step check gave perfect rank agreement (Spearman ρ = Kendall τ = 1.000), although this is a weak test. The landscape and its constants are assumptions of this study, and DE was run once. The work is an algorithmic proof of concept, not a validated vehicle-level system.
- Open Access
- 20 November 2026
- Published by MDPI AG in Preprints.org
A Real-Data Digital Twin Foundation for Battery-Electric Rail Vehicle Li-Ion Packs: Capacity-Fade and Equivalent-Circuit Identification on the NASA PCoE Dataset
Battery-electric rail vehicles (BERVs) need digital twins whose building blocks are identified from measured data before any prognostic or scenario layer is trusted. This study identifies the two foundational sub-models of a Li-ion digital twin from the NASA Ames Prognostics Center of Excellence (PCoE) dataset (cells B0005, B0006, B0007 and B0018): a power-law capacity-fade model and a first-order Thévenin equivalent-circuit model (ECM). Both were fitted by nonlinear least squares to measured data, with no synthetic data. The fade model explained 95.4–97.8% of the capacity variance (R2 = 0.954–0.978; RMSE = 24.5–37.1 mAh). The ECM reproduced one mid-life discharge voltage trace of cell B0005 with R2 = 0.936 (RMSE = 58.6 mV), but the series and polarisation resistances could not be separated: their standard errors exceeded the estimates, which matters for on-board parameter estimation in a rail battery management system. The fit also degrades at the discharge knee and in the post-discharge rest period. Finally, we specify, a vibration-coupled ageing law in which a stress multiplier derived from IEC 61373-type vibration spectra scales the capacity-loss rate. Its coupling coefficient needs vibration-instrumented cycling data that are not yet available.
- 20 November 2026
- Published by MDPI AG in Preprints.org
Open AccessA Real-Data Digital Twin Foundation for Battery-Electric Rail Vehicle Li-Ion Packs: Capacity-Fade and Equivalent-Circuit Identification on the NASA PCoE Dataset
Battery-electric rail vehicles (BERVs) need digital twins whose building blocks are identified from measured data before any prognostic or scenario layer is trusted. This study identifies the two foundational sub-models of a Li-ion digital twin from the NASA Ames Prognostics Center of Excellence (PCoE) dataset (cells B0005, B0006, B0007 and B0018): a power-law capacity-fade model and a first-order Thévenin equivalent-circuit model (ECM). Both were fitted by nonlinear least squares to measured data, with no synthetic data. The fade model explained 95.4–97.8% of the capacity variance (R2 = 0.954–0.978; RMSE = 24.5–37.1 mAh). The ECM reproduced one mid-life discharge voltage trace of cell B0005 with R2 = 0.936 (RMSE = 58.6 mV), but the series and polarisation resistances could not be separated: their standard errors exceeded the estimates, which matters for on-board parameter estimation in a rail battery management system. The fit also degrades at the discharge knee and in the post-discharge rest period. Finally, we specify, a vibration-coupled ageing law in which a stress multiplier derived from IEC 61373-type vibration spectra scales the capacity-loss rate. Its coupling coefficient needs vibration-instrumented cycling data that are not yet available.
- Open Access
- 23 August 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-14
Few-Shot Learning for Image-Based Nonintrusive Appliance Signal Recognition
In this article, we present the recognition of nonintrusive disaggregated appliance signals through a reduced dataset computer vision deep learning approach. Deep learning data requirements are costly in terms of acquisition time, storage memory requirements, computation time, and dynamic memory usage. We develop our recognition strategy on Siamese and prototypical reduced data few-shot classification algorithms. Siamese networks address the 1-shot recognition well. Appliance activation periods vary considerably, and this can result in imbalance in the number of appliance-specific generated signal images. Prototypical networks address the problem of data imbalance in training. By first carrying out a similarity test on the entire dataset, we establish the quality of our data before input into the deep learning algorithms. The results give acceptable performance and show the promise of few-shot learning in recognizing appliances in the nonintrusive load-monitoring scheme for very limited data samples.
- 23 August 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-14
Open AccessFew-Shot Learning for Image-Based Nonintrusive Appliance Signal Recognition
In this article, we present the recognition of nonintrusive disaggregated appliance signals through a reduced dataset computer vision deep learning approach. Deep learning data requirements are costly in terms of acquisition time, storage memory requirements, computation time, and dynamic memory usage. We develop our recognition strategy on Siamese and prototypical reduced data few-shot classification algorithms. Siamese networks address the 1-shot recognition well. Appliance activation periods vary considerably, and this can result in imbalance in the number of appliance-specific generated signal images. Prototypical networks address the problem of data imbalance in training. By first carrying out a similarity test on the entire dataset, we establish the quality of our data before input into the deep learning algorithms. The results give acceptable performance and show the promise of few-shot learning in recognizing appliances in the nonintrusive load-monitoring scheme for very limited data samples.
- Open Access
- 5 January 2021
- Published by Springer Nature in Complex & Intelligent Systems
- Vol. 7 (2) , 901-927
Image-based mains signal disaggregation and load recognition
The mains signal is a complex fusion of various electrical equipment load signals in a building. In the non-intrusive load monitoring recognition, our main aim is to be able to extract as much load features as possible from the complex aggregate mains signal in a simpler way through a computer vision-based approach as opposed to the powers series signal approach. Power series methods, which are one dimensional in nature, suffer from poor aggregate and load signal feature localization necessitating a larger training dataset spanning very long time periods and normally require signal formatting and pre-processing. We use Gramian angular summation fields to transform the power series into a reduced image dataset that contains a rich set of localized signal features. A computer vision approach allows us to capture as much information as possible, and then propose an image-based mains load recognition system with high performance. In this paper for the entire recognition system, we use convolutional neural networks that very well adapted to vision recognition. The load signal image disaggregation is achieved through the powerful stacked denoising autoencoder noise extraction network. To test the proposed system, some simulations and comparisons are carried out and the results show that our easier to handle method can achieve acceptable performance.
- 5 January 2021
- Published by Springer Nature in Complex & Intelligent Systems
- Vol. 7 (2) , 901-927
Open AccessImage-based mains signal disaggregation and load recognition
The mains signal is a complex fusion of various electrical equipment load signals in a building. In the non-intrusive load monitoring recognition, our main aim is to be able to extract as much load features as possible from the complex aggregate mains signal in a simpler way through a computer vision-based approach as opposed to the powers series signal approach. Power series methods, which are one dimensional in nature, suffer from poor aggregate and load signal feature localization necessitating a larger training dataset spanning very long time periods and normally require signal formatting and pre-processing. We use Gramian angular summation fields to transform the power series into a reduced image dataset that contains a rich set of localized signal features. A computer vision approach allows us to capture as much information as possible, and then propose an image-based mains load recognition system with high performance. In this paper for the entire recognition system, we use convolutional neural networks that very well adapted to vision recognition. The load signal image disaggregation is achieved through the powerful stacked denoising autoencoder noise extraction network. To test the proposed system, some simulations and comparisons are carried out and the results show that our easier to handle method can achieve acceptable performance.
- 13 August 2020
- Published by Springer Nature
- p. 345-356
Disaggregated Power System Signal Recognition Using Capsule Network
- 13 August 2020
- Published by Springer Nature
- p. 345-356
Disaggregated Power System Signal Recognition Using Capsule Network
- Open Access
- 28 February 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-18
Fuzzy Logic System for Intermixed Biogas and Photovoltaics Measurement and Control
This study develops a new integrated measurement and control system for intermixed biogas and photovoltaic systems to achieve safe and optimal energy usage. Literature and field studies show that existing control methods on small- to medium-scale systems fall short of comprehensive system optimization and fault diagnosis, hence the need to revisit these control methods. The control strategy developed in this study is intelligent as it is wholly based on fuzzy logic algorithms. Fuzzy logic controllers due to their superior nonlinear problem solving capabilities to classical controllers considerably simplify controller design. The mathematical models that define classical controllers are difficult or impossible to realize in biogas and photovoltaic generation process. A microcontroller centered fuzzy logic measurement and control embedded system is designed and developed on the existing hybrid biogas and photovoltaic installations. The designed system is able to accurately predict digester stability, quantify biogas output, and carry out biogas fault detection and control. Optimized battery charging and photovoltaic fault detection and control are also successfully implemented. The system is able to optimize the operation and performance of biogas and photovoltaic energy generation.
- 28 February 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-18
Open AccessFuzzy Logic System for Intermixed Biogas and Photovoltaics Measurement and Control
This study develops a new integrated measurement and control system for intermixed biogas and photovoltaic systems to achieve safe and optimal energy usage. Literature and field studies show that existing control methods on small- to medium-scale systems fall short of comprehensive system optimization and fault diagnosis, hence the need to revisit these control methods. The control strategy developed in this study is intelligent as it is wholly based on fuzzy logic algorithms. Fuzzy logic controllers due to their superior nonlinear problem solving capabilities to classical controllers considerably simplify controller design. The mathematical models that define classical controllers are difficult or impossible to realize in biogas and photovoltaic generation process. A microcontroller centered fuzzy logic measurement and control embedded system is designed and developed on the existing hybrid biogas and photovoltaic installations. The designed system is able to accurately predict digester stability, quantify biogas output, and carry out biogas fault detection and control. Optimized battery charging and photovoltaic fault detection and control are also successfully implemented. The system is able to optimize the operation and performance of biogas and photovoltaic energy generation.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 98-104
Fuzzy logic based solar panel and battery control system design
Photovoltaic systems, whether they are domestic, commercial or industrial often incorporate some forms of system protection. However, elaborate real-time fault detection is not defined for most such systems. To address this shortfall, a comprehensive photovoltaic installation system fault detection and control strategy is presented in this paper. The designed system is made up of fault detection in any of one of the photovoltaic system components that include the solar panel, charge controller, battery and inverter. The system also includes battery and user load current control. Fuzzy logic principle, due to its powerful non-linear problem solving capabilities is used in formulation of the fault detection and control algorithms as opposed to the classical method. This results in simpler, cheaper and faster hardware, which in this case is implemented on the PIC18F4550 microcontroller.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 98-104
Fuzzy logic based solar panel and battery control system design
Photovoltaic systems, whether they are domestic, commercial or industrial often incorporate some forms of system protection. However, elaborate real-time fault detection is not defined for most such systems. To address this shortfall, a comprehensive photovoltaic installation system fault detection and control strategy is presented in this paper. The designed system is made up of fault detection in any of one of the photovoltaic system components that include the solar panel, charge controller, battery and inverter. The system also includes battery and user load current control. Fuzzy logic principle, due to its powerful non-linear problem solving capabilities is used in formulation of the fault detection and control algorithms as opposed to the classical method. This results in simpler, cheaper and faster hardware, which in this case is implemented on the PIC18F4550 microcontroller.
- Open Access
- 1 January 2017
- Published by Elsevier in Procedia Manufacturing
- Vol. 7, 339-344
Fuzzy Logic Algorithms Based Measurement and Control System for Intermixed Biogas and Photovoltaic Systems
- 1 January 2017
- Published by Elsevier in Procedia Manufacturing
- Vol. 7, 339-344
Open AccessFuzzy Logic Algorithms Based Measurement and Control System for Intermixed Biogas and Photovoltaic Systems
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 249-253
Biogas system fault detection and control
Critical aspects that are lacking in present digester operation are that of fault detection and control. Too high or too low a biogas pressure, methane gas leak, oxygen ingress into the digester and varying slurry levels are all potential contributors of catastrophe, to the installation and to the user. In this paper an integrated fault detection and control strategy based both on fuzzy logic algorithm of internal digesters' operating conditions and external leak detection is developed. The fuzzy logic algorithm being fed by pressure and slurry level inputs seeks to establish the internal danger level of the digester at any particular instant with the view of taking corrective action, whilst any methane and oxygen leaks are to be immediately halted. The fault detection and control strategy is implemented in the PIC18F4550-I/P microcontroller.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 249-253
Biogas system fault detection and control
Critical aspects that are lacking in present digester operation are that of fault detection and control. Too high or too low a biogas pressure, methane gas leak, oxygen ingress into the digester and varying slurry levels are all potential contributors of catastrophe, to the installation and to the user. In this paper an integrated fault detection and control strategy based both on fuzzy logic algorithm of internal digesters' operating conditions and external leak detection is developed. The fuzzy logic algorithm being fed by pressure and slurry level inputs seeks to establish the internal danger level of the digester at any particular instant with the view of taking corrective action, whilst any methane and oxygen leaks are to be immediately halted. The fault detection and control strategy is implemented in the PIC18F4550-I/P microcontroller.