Véronique Miette
Research Subjects
Research Interests
Véronique Miette has a total of 254 co-authors. Here are the top co-authors by number of shared publications:
Laurent Sandrin
R&D Department, Echosens, Paris, France
15 shared publications- Magali Sasso
R&D Department, Echosens, Paris, France
9 shared publications L. Sandrin
6 shared publicationsYuejun Liu
R&D Department, Echosens, Paris, France; Institute of Cardiometabolism and Nutrition, ICAN, UMR INSERM/UPMC 1166, Nutrition Department, Pitié-Salpêtrière Hospital, Paris, France
5 shared publicationsC. Fournier
Medical Affairs Department, Echosens, Paris
4 shared publicationsGilles Le Naour
4 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 11 November 2022
- Published by Elsevier in Journal of Hepatology
- Vol. 78 (2) , 247-259
Enhanced diagnosis of advanced fibrosis and cirrhosis in individuals with NAFLD using FibroScan-based Agile scores
- 11 November 2022
- Published by Elsevier in Journal of Hepatology
- Vol. 78 (2) , 247-259
Top Cited PapersOpen AccessEnhanced diagnosis of advanced fibrosis and cirrhosis in individuals with NAFLD using FibroScan-based Agile scores
- 7 January 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (3) , 569-581
Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
Objectives: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.Methods: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.Results: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.Conclusions: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
- 7 January 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (3) , 569-581
Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
Objectives: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.Methods: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.Results: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.Conclusions: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
- Top Cited PapersOpen Access
- 1 April 2020
- Published by Elsevier in The Lancet Gastroenterology & Hepatology
- Vol. 5 (4) , 362-373
FibroScan-AST (FAST) score for the non-invasive identification of patients with non-alcoholic steatohepatitis with significant activity and fibrosis: a prospective derivation and global validation study
- 1 April 2020
- Published by Elsevier in The Lancet Gastroenterology & Hepatology
- Vol. 5 (4) , 362-373
Top Cited PapersOpen AccessFibroScan-AST (FAST) score for the non-invasive identification of patients with non-alcoholic steatohepatitis with significant activity and fibrosis: a prospective derivation and global validation study
- Open Access
- 26 July 2019
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 31 (5) , 665-673
Use of serum biomarkers in staging of canine hepatic fibrosis
Accurate staging of hepatic fibrosis (HF) is important for treatment and prognosis of canine chronic hepatitis. HF scores are used in human medicine to indirectly stage and monitor HF, decreasing the need for liver biopsy. We developed a canine HF score to screen for moderate or greater HF. We included 96 dogs in our study, including 5 healthy dogs. A liver biopsy for histologic examination and a biochemistry profile were performed on all dogs. The dogs were randomly split into a training set of 58 dogs and a validation set of 38 dogs. A HF score that included alanine aminotransferase, alkaline phosphatase, total bilirubin, potassium, and gamma-glutamyl transferase was developed in the training set. Model performance was confirmed using the internal validation set, and was similar to the performance in the training set. The overall sensitivity and specificity for the study group were 80% and 70% respectively, with an area under the curve of 0.80 (0.71–0.90). This HF score could be used for indirect diagnosis of canine HF when biochemistry panels are performed on the Konelab 30i (Thermo Scientific), using reagents as in our study. External validation is required to determine if the score is sufficiently robust to utilize biochemical results measured in other laboratories with different instruments and methodologies.
- 26 July 2019
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 31 (5) , 665-673
Open AccessUse of serum biomarkers in staging of canine hepatic fibrosis
Accurate staging of hepatic fibrosis (HF) is important for treatment and prognosis of canine chronic hepatitis. HF scores are used in human medicine to indirectly stage and monitor HF, decreasing the need for liver biopsy. We developed a canine HF score to screen for moderate or greater HF. We included 96 dogs in our study, including 5 healthy dogs. A liver biopsy for histologic examination and a biochemistry profile were performed on all dogs. The dogs were randomly split into a training set of 58 dogs and a validation set of 38 dogs. A HF score that included alanine aminotransferase, alkaline phosphatase, total bilirubin, potassium, and gamma-glutamyl transferase was developed in the training set. Model performance was confirmed using the internal validation set, and was similar to the performance in the training set. The overall sensitivity and specificity for the study group were 80% and 70% respectively, with an area under the curve of 0.80 (0.71–0.90). This HF score could be used for indirect diagnosis of canine HF when biochemistry panels are performed on the Konelab 30i (Thermo Scientific), using reagents as in our study. External validation is required to determine if the score is sufficiently robust to utilize biochemical results measured in other laboratories with different instruments and methodologies.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Hybrid Elastography: A New Technique for the Assessment of Tissue Stiffness
Vibration-Controlled Transient Elastography (VCTE) is a clinically well validated method to assess Liver Stiffness (LS) using FibroScan (Echosens, Paris, France). The operator relies on ultrasound (U/S) A-and M-mode images to locate the liver. Finding a good measurement window is key to get a good penetration of the Shear Wave (SW) and therefore a valid LS measurement. However, relying only on U/S may be suboptimal to identify the right measurement position. We developed a new technique called Hybrid Elastography (HE) that combines monochromatic and transient elastography, respectively to assist the operator finding an optimal measurement position and to perform the measurement.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Hybrid Elastography: A New Technique for the Assessment of Tissue Stiffness
Vibration-Controlled Transient Elastography (VCTE) is a clinically well validated method to assess Liver Stiffness (LS) using FibroScan (Echosens, Paris, France). The operator relies on ultrasound (U/S) A-and M-mode images to locate the liver. Finding a good measurement window is key to get a good penetration of the Shear Wave (SW) and therefore a valid LS measurement. However, relying only on U/S may be suboptimal to identify the right measurement position. We developed a new technique called Hybrid Elastography (HE) that combines monochromatic and transient elastography, respectively to assist the operator finding an optimal measurement position and to perform the measurement.
- 1 August 2018
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 44 (8) , 1616-1626
A Novel FibroScan Examination Dedicated to Spleen Stiffness Measurement
- 1 August 2018
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 44 (8) , 1616-1626
A Novel FibroScan Examination Dedicated to Spleen Stiffness Measurement
- 1 May 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 283 (2) , 418-428
Diagnostic Performance of MR Elastography and Vibration-controlled Transient Elastography in the Detection of Hepatic Fibrosis in Patients with Severe to Morbid Obesity
The results of the study show that in this obese patient population, both MR elastography and vibration-controlled transient elastography (VCTE) had excellent diagnostic performance for assessing l... Purpose To evaluate the diagnostic performance and examination success rate of magnetic resonance (MR) elastography and vibration-controlled transient elastography (VCTE) in the detection of hepati...
- 1 May 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 283 (2) , 418-428
Diagnostic Performance of MR Elastography and Vibration-controlled Transient Elastography in the Detection of Hepatic Fibrosis in Patients with Severe to Morbid Obesity
The results of the study show that in this obese patient population, both MR elastography and vibration-controlled transient elastography (VCTE) had excellent diagnostic performance for assessing l... Purpose To evaluate the diagnostic performance and examination success rate of magnetic resonance (MR) elastography and vibration-controlled transient elastography (VCTE) in the detection of hepati...
- 1 March 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43 (3) , 670-681
High-Resolution Elastography for Thin-Layer Mechanical Characterization: Toward Skin Investigation
- 1 March 2017
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 43 (3) , 670-681
High-Resolution Elastography for Thin-Layer Mechanical Characterization: Toward Skin Investigation
- 1 October 2016
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 42 (10) , 2401-2413
AdipoScan: A Novel Transient Elastography-Based Tool Used to Non-Invasively Assess Subcutaneous Adipose Tissue Shear Wave Speed in Obesity
- 1 October 2016
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 42 (10) , 2401-2413
AdipoScan: A Novel Transient Elastography-Based Tool Used to Non-Invasively Assess Subcutaneous Adipose Tissue Shear Wave Speed in Obesity