Saad Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saad Ali has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Gregory L. Katzman
Department of Radiology, The University of Chicago, Illinois
3 shared publicationsCarina W. Yang
Department of Radiology, The University of Chicago, Chicago, IL
2 shared publicationsRishi Ramakrishna
Department of Radiology, The University of Chicago, Chicago, IL
2 shared publications- Seon-Kyu Lee
Radiology, Montefiore Hospital and Medical Center, Bronx, New York, USA
2 shared publications Amar S. Mehta
Department of Radiology, University of Chicago Medical Center, 5841 S Maryland Ave., MC2026, Chicago, IL 60637, USA
1 shared publicationAnup Alexander
Department of Radiology
1 shared publication
Latest Publications
- 17 June 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (2) , 191-195
Sacroiliac joint injections with the guidance of three-dimensional cone beam computed tomography (3D-CBCT) and fluoroscopy fusion
Background We describe our diagnostic sacroiliac joint (SIJ) injection technique under the guidance of three-dimensional cone beam computed tomography (3D-CBCT) fused with real-time fluoroscopy. Methods A retrospective review of 17 patients (mean age 55.4 (range 40–74) years) who received a total of 23 diagnostic SIJ injections between March 2016 and November 2017 were performed. Pre- and post-procedure pain scores were reviewed from the medical records and then these findings were correlated with which patients were and were not diagnosed with SIJ pain by clinical management. The final diagnosis of SIJ-related pain was made in cases with at least 50% symptomatic improvement following SIJ-specific pain treatments. Results Some 87% (n=20/23) of injections achieved more than 50% pain relief after the diagnostic SIJ injection. The final diagnosis of the target SIJ-related pain after follow-up and management was found in 90% (n=18/20) of cases. There were two cases with positive tests diagnosed as non-SIJ pain including one with the diagnosis of femuroacetabular impingement and one with pain related to loosening of knee hardware. The sensitivity, specificity, positive predictive value, and negative predicative value of diagnostic SIJ injections were 100%, 60%, 89%, and 100%, respectively, with a 40% false-positive rate. There were no procedure-related complications. Conclusion 3D-CBCT fused with real-time fluoroscopy for SIJ injection is accurate and safe.
- 17 June 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (2) , 191-195
Sacroiliac joint injections with the guidance of three-dimensional cone beam computed tomography (3D-CBCT) and fluoroscopy fusion
Background We describe our diagnostic sacroiliac joint (SIJ) injection technique under the guidance of three-dimensional cone beam computed tomography (3D-CBCT) fused with real-time fluoroscopy. Methods A retrospective review of 17 patients (mean age 55.4 (range 40–74) years) who received a total of 23 diagnostic SIJ injections between March 2016 and November 2017 were performed. Pre- and post-procedure pain scores were reviewed from the medical records and then these findings were correlated with which patients were and were not diagnosed with SIJ pain by clinical management. The final diagnosis of SIJ-related pain was made in cases with at least 50% symptomatic improvement following SIJ-specific pain treatments. Results Some 87% (n=20/23) of injections achieved more than 50% pain relief after the diagnostic SIJ injection. The final diagnosis of the target SIJ-related pain after follow-up and management was found in 90% (n=18/20) of cases. There were two cases with positive tests diagnosed as non-SIJ pain including one with the diagnosis of femuroacetabular impingement and one with pain related to loosening of knee hardware. The sensitivity, specificity, positive predictive value, and negative predicative value of diagnostic SIJ injections were 100%, 60%, 89%, and 100%, respectively, with a 40% false-positive rate. There were no procedure-related complications. Conclusion 3D-CBCT fused with real-time fluoroscopy for SIJ injection is accurate and safe.
- 1 February 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (2) , 235-239
Virtual Simulation in Enhancing Procedural Training for Fluoroscopy-guided Lumbar Puncture
- 1 February 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (2) , 235-239
Virtual Simulation in Enhancing Procedural Training for Fluoroscopy-guided Lumbar Puncture
- 1 January 2018
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of neurosurgery. Pediatrics
- Vol. 21 (1) , 4-10
Magnetic resonance imaging in the prone position and the diagnosis of tethered spinal cord
OBJECTIVE: Tethered cord syndrome (TCS) is a neurosurgical disorder with varied clinical manifestations believed to result from vascular compromise due to stretch forces on the spinal cord. Conventional supine MRI findings may include a low-lying conus medullaris, thickened or fat-infiltrated filum terminale, or lipoma; however, imaging sensitivity and specificity for tethered cord can be low. The purpose of this study was to evaluate the utility of prone MRI in the diagnosis of tethered and retethered spinal cord.METHODS: Medical records were reviewed in 41 patients who underwent surgical release of tethered cord and in whom preoperative prone MRI sequences were available. Patients were divided into Group 1 (new TCS diagnosis) and Group 2 (recurrent TCS after previous untethering). Absolute conus ventral motion and motion as a percentage of canal width between supine and prone positions was measured in these 2 groups via sagittal T2-weighted sequences; these groups were compared with 30 consecutive patients (Group 3) who were classified as the normal control group.RESULTS: The mean ventral motion was as follows: Group 1 (absolute: 0.5 ± 0.5 mm [range 0–2.4 mm]; canal percentage: 3.7% ± 3.9% [range 0%–16.3%]); Group 2 (absolute: 0.4 ± 0.7 mm [range 0–2.6 mm]; canal percentage: 2.2% ± 3.7% [range 0%–14.0%]); and Group 3 (absolute: 3.4 ± 1.3 mm [range 1.4–5.6 mm]; canal percentage: 22.0% ± 7.2% [range 10.5%–36.1%]). Whereas 38/41 surgically treated patients with TCS had diminished (< 10% canal width) ventral motion on preoperative MRI, 30/30 controls had > 10% canal width motion. Sensitivity and specificity were thereby calculated as 92.7% and 100%, respectively.CONCLUSIONS: In the present series, prone imaging is found to be a sensitive and specific tool, and the authors believe it may have a role as supportive evidence in the diagnosis of tethered and retethered spinal cord.
- 1 January 2018
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of neurosurgery. Pediatrics
- Vol. 21 (1) , 4-10
Magnetic resonance imaging in the prone position and the diagnosis of tethered spinal cord
OBJECTIVE: Tethered cord syndrome (TCS) is a neurosurgical disorder with varied clinical manifestations believed to result from vascular compromise due to stretch forces on the spinal cord. Conventional supine MRI findings may include a low-lying conus medullaris, thickened or fat-infiltrated filum terminale, or lipoma; however, imaging sensitivity and specificity for tethered cord can be low. The purpose of this study was to evaluate the utility of prone MRI in the diagnosis of tethered and retethered spinal cord.METHODS: Medical records were reviewed in 41 patients who underwent surgical release of tethered cord and in whom preoperative prone MRI sequences were available. Patients were divided into Group 1 (new TCS diagnosis) and Group 2 (recurrent TCS after previous untethering). Absolute conus ventral motion and motion as a percentage of canal width between supine and prone positions was measured in these 2 groups via sagittal T2-weighted sequences; these groups were compared with 30 consecutive patients (Group 3) who were classified as the normal control group.RESULTS: The mean ventral motion was as follows: Group 1 (absolute: 0.5 ± 0.5 mm [range 0–2.4 mm]; canal percentage: 3.7% ± 3.9% [range 0%–16.3%]); Group 2 (absolute: 0.4 ± 0.7 mm [range 0–2.6 mm]; canal percentage: 2.2% ± 3.7% [range 0%–14.0%]); and Group 3 (absolute: 3.4 ± 1.3 mm [range 1.4–5.6 mm]; canal percentage: 22.0% ± 7.2% [range 10.5%–36.1%]). Whereas 38/41 surgically treated patients with TCS had diminished (< 10% canal width) ventral motion on preoperative MRI, 30/30 controls had > 10% canal width motion. Sensitivity and specificity were thereby calculated as 92.7% and 100%, respectively.CONCLUSIONS: In the present series, prone imaging is found to be a sensitive and specific tool, and the authors believe it may have a role as supportive evidence in the diagnosis of tethered and retethered spinal cord.
- 1 January 2018
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 210 (1) , W18-W21
Improving Clinical Information on Head CT Requisitions From the Emergency Department to Aid Interpretation and Billing Efficiency
OBJECTIVE. The accuracy of radiologic interpretations is higher when appropriate clinical information is provided, as is the likelihood of reimbursement for the studies. The purpose of this project was to evaluate and improve the quality of clinical information provided on head CT requisitions from an urban emergency department (ED). SUBJECTS AND METHODS. In a prospective study conducted from July 2015 to May 2016, attending neuroradiologists evaluated 1100 randomly selected ED requisitions for unenhanced head CT, grading them for clinical and billing adequacy on a scale of 0–2. After acquisition of baseline data (400 studies), an intervention was performed that consisted of education of ED staff on the importance of clinical information in requisitions. A reminder slide was placed on a large screen in the ED staff working area with examples of appropriate history. Postintervention data (700 studies) were subsequently obtained. Mean scores and payment lag time before versus after the intervention were compared by Wilcoxon rank sum test. RESULTS. Statistically significant improvement was found in mean scores after the intervention for both clinical (1.32 to 1.43, p = 0.003) and billing (1.64 to 1.74, p = 0.02) adequacy categories. The percentage of studies with a score of 2 increased in both categories, and the percentages of 0 and 1 scores declined. There was a 21.1-day decrease in payment lag time (from 75.8 to 54.7 days, p < 0.0001). CONCLUSION. The quality of clinical information provided on imaging requisitions by ED faculty and residents improved after a fairly simple intervention. Billing efficiency improved, and payment lag time decreased substantially.
- 1 January 2018
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 210 (1) , W18-W21
Improving Clinical Information on Head CT Requisitions From the Emergency Department to Aid Interpretation and Billing Efficiency
OBJECTIVE. The accuracy of radiologic interpretations is higher when appropriate clinical information is provided, as is the likelihood of reimbursement for the studies. The purpose of this project was to evaluate and improve the quality of clinical information provided on head CT requisitions from an urban emergency department (ED). SUBJECTS AND METHODS. In a prospective study conducted from July 2015 to May 2016, attending neuroradiologists evaluated 1100 randomly selected ED requisitions for unenhanced head CT, grading them for clinical and billing adequacy on a scale of 0–2. After acquisition of baseline data (400 studies), an intervention was performed that consisted of education of ED staff on the importance of clinical information in requisitions. A reminder slide was placed on a large screen in the ED staff working area with examples of appropriate history. Postintervention data (700 studies) were subsequently obtained. Mean scores and payment lag time before versus after the intervention were compared by Wilcoxon rank sum test. RESULTS. Statistically significant improvement was found in mean scores after the intervention for both clinical (1.32 to 1.43, p = 0.003) and billing (1.64 to 1.74, p = 0.02) adequacy categories. The percentage of studies with a score of 2 increased in both categories, and the percentages of 0 and 1 scores declined. There was a 21.1-day decrease in payment lag time (from 75.8 to 54.7 days, p < 0.0001). CONCLUSION. The quality of clinical information provided on imaging requisitions by ED faculty and residents improved after a fairly simple intervention. Billing efficiency improved, and payment lag time decreased substantially.
- 29 July 2017
- Published by BMJ in BMJ Simulation and Technology Enhanced Learning
- Vol. 4 (4) , 205-206
Simulation of fluoroscopic-guided lumbar puncture with a novel spine task trainer
The use of fluoroscopy in guiding spinal procedures can be challenging to a new learner as it requires integration of anatomy and procedural technique while attempting to minimise fluoroscopy times and radiation dosage; the importance of the latter is indicated by data revealing medical radiation's contribution of almost half of the American population's average annual radiation exposure.1 The procedure is traditionally taught on actual patients who are awake, aware and without sedation. Unfamiliarity of a new learner with the procedure can lead to undue patient anxiety, pain and increased radiation dose, as well as increased stress on the learner.2,3 The ability to train for this procedure …
- 29 July 2017
- Published by BMJ in BMJ Simulation and Technology Enhanced Learning
- Vol. 4 (4) , 205-206
Simulation of fluoroscopic-guided lumbar puncture with a novel spine task trainer
The use of fluoroscopy in guiding spinal procedures can be challenging to a new learner as it requires integration of anatomy and procedural technique while attempting to minimise fluoroscopy times and radiation dosage; the importance of the latter is indicated by data revealing medical radiation's contribution of almost half of the American population's average annual radiation exposure.1 The procedure is traditionally taught on actual patients who are awake, aware and without sedation. Unfamiliarity of a new learner with the procedure can lead to undue patient anxiety, pain and increased radiation dose, as well as increased stress on the learner.2,3 The ability to train for this procedure …
- 1 December 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (12) , e17-e18
Hemorrhagic schwannoma presenting with subarachnoid hemorrhage and resulting cauda equina syndrome
- 1 December 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (12) , e17-e18
Hemorrhagic schwannoma presenting with subarachnoid hemorrhage and resulting cauda equina syndrome
- Open Access
- 1 October 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (12) , E69-E70
Ipilimumab Therapy for Melanoma: A Mimic of Leptomeningeal Metastases
We have recently observed that patients with malignant melanoma on treatment with ipilimumab can demonstrate leptomeningeal enhancement on brain MR imaging mimicking metastatic disease. In [Fig 1][1] is shown one such case of a 40-year-old man presenting with subacute onset of headaches, right-sided
- 1 October 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (12) , E69-E70
Open AccessIpilimumab Therapy for Melanoma: A Mimic of Leptomeningeal Metastases
We have recently observed that patients with malignant melanoma on treatment with ipilimumab can demonstrate leptomeningeal enhancement on brain MR imaging mimicking metastatic disease. In [Fig 1][1] is shown one such case of a 40-year-old man presenting with subacute onset of headaches, right-sided