RERadwa Mohsen Kamal Emera

Radwa Mohsen Kamal Emera

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Radwa Mohsen Kamal Emera has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of patients’ oral health-related quality of life and chewing efficiency between conventional and 3D-printed complete dentures: A crossover clinical trial

    by Radwa Mohsen Kamal Emera, Zeena Farhan AL Sultani, Fatma Fathe Mahanna

    Background. Additive manufacturing has introduced novel materials and workflows for complete denture fabrication; however, high-quality clinical evidence comparing patient-centered outcomes of 3D-printed and conventionally fabricated dentures remains limited. This compared oral health-related quality of life (OHRQoL) and chewing efficiency between conventional and 3D-printed dimethacrylate-based resin complete dentures. Methods. Twenty completely edentulous patients were enrolled in this randomized two-period crossover clinical trial. Each participant received both interventions—conventional complete dentures and 3D-printed dimethacrylate-based resin complete dentures—in a randomized sequence. OHRQoL was assessed using the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT), and chewing efficiency was evaluated using a two-colored chewing gum mixing ability test by calculating the standard deviation of hue (H-SD). Assessments were performed at insertion (T0), after 3 months (T3), and after 6 months (T6). Normality was assessed using the Shapiro–Wilk test. Intra-subject comparisons were conducted using the Wilcoxon signed-rank test for OHIP-EDENT scores and paired t-tests for chewing efficiency. Statistical significance was set at P≤0.05. Results. No statistically significant differences were observed between conventional and 3D-printed dentures regarding overall OHIP-EDENT scores or individual domains at T0 , T3 , or T6 (P>0.05). Both denture types demonstrated significant improvements in OHRQoL from the pre-treatment period to T6 (P0.05). Conclusion. Within the limitations of this randomized crossover study, 3D-printed dimethacrylate-based resin complete dentures demonstrated clinical performance and satisfaction comparable to conventional dentures, supporting their use as a reliable alternative in complete denture rehabilitation.

  • Open Access

    Comparison of retention and denture base adaptation between conventional and 3D-printed complete dentures

    by Radwa Mohsen Kamal Emera, Mohamed Shady, Mahmoud Almabrouk Alnajih

    Background. In recent years, complete denture construction has been revolutionized using computer-aided designing and computer-aided manufacturing (CAD-CAM) technology. This clinical study compared the retention and denture base adaptation of 3D-printed complete dentures fabricated using dimethacrylate-based resins with a photoinitiator versus conventional complete dentures. Methods. Ten completely edentulous patients were nominated for this study. Each patient received two complete dentures. One complete denture was conventionally fabricated, while the other was digitally fabricated through 3D printing of dimethacrylate-based resins with a photoinitiator. Denture base adaptation for both dentures was evaluated using surface matching software. Denture retention was also evaluated using a digital force meter at the time of complete denture insertion (T0 ), after three months (T3 ) and six months (T6 ) of denture use. Results. Regarding adaptation (mean misfit values), a statistically insignificant difference was detected between the two differently fabricated complete dentures. In addition, comparable satisfactory retention values were observed for both conventionally fabricated and 3D-printed dentures; however, there was an insignificant increase in retention over time. Conclusion. 3D-printed complete dentures fabricated using dimethacrylate-based resins could be a promising alternative to conventionally fabricated complete dentures with satisfactory denture base adaptation and retention.


  • Open Access

    Denture base adaptation, retention, and mechanical properties of BioHPP versus nano-alumina-modified polyamide resins

    by Radwa Mohsen Kamal Emera, Reham Mohammed Abdallah

    Background. Continuous development of denture base materials has led to the introduction of innovative alternatives to polymethyl methacrylate. The present study aimed to evaluate the mechanical properties, adaptation, and retention of alumina nanoparticles (Al2 O3 NPs) modified polyamide resin versus BioHPP (high-performance polymer) denture base materials. Methods. Four groups of specimens, one control (group I) (unmodified polyamide) and two groups (groups II and III) (2.5 and 5 wt% Al2 O3 NP-modified polyamide, respectively) versus BioHPP specimen group (group IV), were tested for surface microhardness and flexural strength. Complete dentures fabricated from 5 wt% Al2 O3 NP-modified polyamide resin and BioHPP were used to evaluate denture base adaptation and retention. Results. The higher concentration in the alumina NP-modified polyamide group (5 wt%) demonstrated significantly higher flexural strength values and insignificantly higher hardness values than the lower concentration (2.5 wt%). There was a significant increase in the BioHPP group in both flexural strength and surface hardness compared to all polyamide groups. A statistically insignificant difference was observed between the two denture base materials regarding mean misfit values of the calculated total tissue surface area and four of the total seven evaluated areas. Satisfactory and comparable retention values were observed for both denture base materials. Conclusion. BioHPP and Al2 O3 NP-modified polyamide resin could be used as a promising alternative denture base material with good adaptation, retention, and mechanical properties.


  • Open Access

    Retention force of zirconia bar retained implant overdenture: Clinical comparative study between PEEK and plastic clips.

    by Radwa Mohsen Kamal Emera, Gilan Youssef Altonbary

    Aim: This study aimed to evaluate and compare retention force of two implants retained mandibular overdenture with zirconia bar using two different clip materials. Methodology: 20 completely edentulous patients (8 women and 12 men) with age ranged between 45 and 65 years were selected for this study. All patients received conventional maxillary and mandibular complete dentures. Two implants were inserted bilaterally in the mandibular canine region. CAD-CAM fabricated zirconia bar attachment was used to retain mandibular overdentures. Patients were randomly divided into two equal groups where poly-oxy-methylene (POM) clip was used for Group I and poly-ether-ether-ketone (PEEK) clip for Group II. Retention force was measured at time of overdenture insertion (T0), six months (T6), and twelve months (T12) later. Results: significant difference was recorded between the two groups in initial retention forces (T0) where PEEK clip group recorded higher retention forces in comparison to POM clip group (P=0.029). However, insignificant difference was observed at (T6) and (T12). Within group comparison of mean retention values at different follow-up periods revealed significant difference for both groups. Conclusion: Within parameters of this study, it could be concluded that both POM and PEEK retentive clips can provide comparable retention forces when used with zirconia bar during 12 months period of overdenture use. How to cite this article: Emera RMK, Altonbary GY. Retention force of zirconia bar retained implant overdenture: Clinical comparative study between PEEK and plastic clips. Int Dent Res 2019;9(3):92-8. Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


  • Effect of Different Degrees of Mesial Implant Inclination on the Retention and Stability of Two-Implant Mandibular Overdentures Retained with Stud Attachments: An In Vitro Study

    by Moustafa Elsyad, Omar Hatem, Ahmad Shawky, Radwa Emera

    Moustafa Abdou ELsyad, BDS, MSc, PhD/Omar Emhemed Abo Hatem, BDS/Ahmad Fathalla Shawky, BDS, MSc, PhD/Radwa Mohsen Kamal Emera, BDS, MSc, PhD: Purpose: To evaluate the effect of different degrees of mesial implant inclinations on the retention and stability of two-implant mandibular overdentures retained with stud attachments. Materials and Methods: Four experimental mandibular acrylic models were constructed. Two laboratory implants were inserted in the canine areas of each model with the following degrees of mesial inclinations: 0, 5, 10, and 20 degrees. Experimental overdentures were connected to the implants with Locator extra-light retention (Le), Locator light retention (Ll), and Locator medium retention (Lm). Vertical (retention) and oblique (stability) dislodging forces (anterior, posterior, and lateral) were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention). Results: The final retention was not significantly affected by small (5 degrees) and large (20 degrees) implant inclinations, but decreased with a moderate (10 degrees) inclination. For a small implant inclination (5 degrees), Lm showed the highest final retention/stability and Le showed the lowest, while for moderate and large inclinations (10 and 20 degrees), Le showed the highest final retention/stability and Lm showed the lowest. Vertical dislodging recorded the highest final stability, and lateral dislodgment recorded the lowest stability. Conclusion: Within the limitations of this in vitro study, only moderate implant angulation (10 degrees) negatively affects the final retention and stability of Locator-retained overdentures. Locator medium retention for small angulation (5 degrees) and Locator extra-light retention for moderate (10 degrees) and large (20 degrees) angulations are recommended to maintain high retention and stability after 540 cycles of denture insertion and removal.