ARAdela Roubickova

Adela Roubickova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adela Roubickova has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Pavel Bradna

    Institute of Dental Medicine, First Faculty of Medicine of the Charles University and General University Hospital in Prague, Karlovo namesti 32, Prague, 121 11, Czech Republic

    4 shared publications
  • Michal Dudek

    Michal Dudek, MD, Institute of Clinical and Experimental Dental Medicine, First Faculty of Medicine of the Charles University in Prague, General Teaching Hospital, Prague, Czech Republic

    3 shared publications
  • D Housova

    Devana Housova, MD, PhD, Institute of Clinical and Experimental Dental Medicine, First Faculty of Medicine of the Charles University in Prague, General Teaching Hospital, Prague, Czech Republic

    2 shared publications
  • L Comba

    Lukas Comba, MD, First Faculty of Medicine of the Charles University Institute of Clinical and Experimental Dental Medicine, First Faculty of Medicine of the Charles University in Prague, General Teaching Hospital, Prague, Czech Republic

    2 shared publications
  • Radka Vrbova

    Department of Stomatology, General Teaching Hospital, 1st Faculty of Medicine, Charles University, Kateřinská 32, 121 08 Prague, Czech Republic

    2 shared publications
  • Alex Vinsu

    Institute of Dental Medicine, First Faculty of Medicine and General University Hospital in Prague, Charles University, Prague, Czech Republic

    1 shared publication

Latest Publications

  • Open Access

    Transcriptome changes in humans acutely exposed to nanoparticles during grinding of dental nanocomposites

    by Zuzana Simova, Michal Sima, Daniela Pelclova, Pavlina Klusackova, Vladimir Zdimal, Jaroslav Schwarz, Ludmila Maskova, Pavel Bradna, Adela Roubickova, Zdenek Krejcik, et al.

    Aim: Today, there is a lack of research studies concerning human acute exposure to nanoparticles (NPs). Our investigation aimed to simulate real-world acute inhalation exposure to NPs released during work with dental nanocomposites in a dental office or technician laboratory. Methods: Blood samples from female volunteers were processed before and after inhalation exposure. Transcriptomic mRNA and miRNA expression changes were analyzed. Results: We detected large interindividual variability, 90 significantly deregulated mRNAs, and 4 miRNAs when samples of participants before and after dental nanocomposite grinding were compared. Conclusion: The results suggest that inhaled dental NPs may present an occupational hazard to human health, as indicated by the changes in the processes related to oxidative stress, synthesis of eicosanoids, and cell division.


  • Open Access

    Titanium and Other Metal Hypersensitivity Diagnosed by MELISA® Test: Follow‐Up Study

    by Radka Vrbova, Stepan Podzimek, Lucie Himmlova, Adela Roubickova, Marketa Janovska, Tatjana Janatova, Martin Bartos, Alex Vinsu

    This study is aimed at proving the clinical benefit of the MELISA® test in the minimization or complete elimination of health problems in patients with confirmed hypersensitivity to metals used for tissue replacements. A group of 305 patients aged 20‐75 years with previously proven metal hypersensitivity (initial MELISA® test), mainly to titanium and then to another fifteen metals, was chosen from the database at the Institute of Dental Medicine. From these patients, a final group of 42 patients agreed to participate in the study, 35 of which were female and 7 were male. The patients completed a special questionnaire aimed at information regarding change of health status from their last visit and determining whether the results of the initial MELISA® test and recommendations based on it were beneficial for patients or not. They were clinically examined, and peripheral blood samples were taken to perform follow‐up MELISA® tests. Questionnaire data was processed, and the follow‐up MELISA® test results were compared with the results of the initial MELISA® tests. For statistical analysis, the Fisher’s exact test and paired T‐test were used. Thirty‐two patients reported that they followed the recommendations based on the results of the initial MELISA® tests, and of these, 30 patients (94%) confirmed significant health improvement. Six patients did not follow the recommendation, and from these, only one patient reported an improvement in his health problems. By comparison of the initial and follow‐up MELISA® test results, it can be stated that the hypersensitivity to the given metal decreased or disappeared after the therapeutic interventions performed based on the initial MELISA® test results. The evaluation of the data obtained from patients in this study confirmed a significant clinical benefit of MELISA® test.


  • Effect of Postoperative Peroxide Bleaching on the Marginal Seal of Composite Restorations Bonded With Self-etch Adhesives

    by A Roubickova, M Dudek, L Comba, D Housova, P Bradna

    SUMMARY: The aim of this study was to determine the effect of peroxide bleaching on the marginal seal of composite restorations bonded with several adhesive systems. Combined cylindrical Class V cavities located half in enamel and half in dentin were prepared on the buccal and lingual surfaces of human molars. The cavities were bonded with the self-etch adhesives Clearfil SE-Bond (CLF), Adper Prompt (ADP), and iBond (IBO) and an etch-and-rinse adhesive Gluma Comfort Bond (GLU) and restored with a microhybrid composite Charisma. Experimental groups were treated 25 times for eight hours per day with a peroxide bleaching gel Opalescence PF 20, while the control groups were stored in distilled water for two months and then subjected to a microleakage test using a dye penetration method. Scanning electron microscopy was used to investigate the etching and penetration abilities of the adhesives and morphology of debonded restoration-enamel interfaces after the microleakage tests. Statistical analyses were performed using nonparametric Kruskal-Wallis, Mann-Whitney, and Wilcoxon tests at p=0.05. The microleakage of all GLU groups was low and not significantly affected by peroxide bleaching. Low microleakage was recorded for CLF control groups, but after bleaching, a small but significant increase in microleakage at the enamel margin indicated its sensitivity to peroxide bleaching. For ADP and IBO control groups, the microleakage at the enamel margins was significantly higher than for GLU and CLF and exceeded that at the dentin margins. Bleaching did not induce any significant changes in the microleakage. Electron microscopy analysis indicated that in our experimental setup, decreased adhesion and mechanical resistance of the ADP- and IBO-enamel interfaces could be more important than the chemical degradation effects induced by the peroxide bleaching gel.


  • Effect of Postoperative Peroxide Bleaching on the Stability of Composite to Enamel and Dentin Bonds

    by M Dudek, A Roubickova, L Comba, D Housova, P Bradna

    SUMMARY: This study investigated the effect of peroxide bleaching gel on the durability of the adhesive bond between composite material, enamel, and dentin created with the etch-and-rinse adhesive Gluma Comfort Bond (GLU) and with the self-etch adhesives Clearfil SE Bond (CLE), Adper Prompt (ADP), and iBond (IBO). The adhesives were applied to flattened enamel and dentin of extracted human molars and built up with a microhybrid composite (Charisma). After 25 eight-hour cycles of bleaching with a 20% carbamide peroxide bleaching gel (Opalescence PF 20), the shear bond strength was measured and compared with one-day and two-month control specimens stored in water. The data were analyzed using nonparametric Mann-Whitney and Kruskal-Wallis statistics (p<0.05). Detailed fractographic analysis was performed using scanning electron microscopy. The bleaching gel significantly decreased the bond strength on both enamel and dentin for the simplified single-step self-etch adhesives ADP and IBO and markedly affected a fracture pattern of ADP specimens at the periphery of their bonded area. The results of our study indicate that the durability of adhesive restorations can be detrimentally influenced by carbamide peroxide bleaching and that different adhesives show varying sensitivity levels to the bleaching gel.


    • 1 December 2008
      • Vol. 10  (6) , 423-9

    Comparison of bonding performance of self-etching and etch-and-rinse adhesives on human dentin using reliability analysis.

    by Pavel Bradna, Radka Vrbova, Michal Dudek, Adela Roubickova, Devana Housova

    To estimate the in vitro reliability of typical self-etching and etch-and-rinse adhesives of various application protocols. The following adhesives were applied on flat dentin surfaces of extracted human teeth (n = 223): self-etching two-step adhesives: AdheSE (AH), Clearfil SE Bond (CL), OptiBond SE (OS); one-step adhesives: Adper Prompt L-Pop (ADP), Adper Prompt (AD), and Xeno III (XE); all-in-one adhesive: iBond (IB); etch-and-rinse three-step adhesives: OptiBond FL (OF), two-step Gluma Comfort Bond (G), Excite (E) and Prime & Bond NT (PB). Composite buildups were prepared using a microhybrid composite, Opticor New. Shear bond strength was determined after 24 h of storage at 37 degrees C in distilled water. The results were analyzed with a nested ANOVA (adhesive, type of adhesive) followed by the Fisher post-hoc tests of group homogeneity at alpha = 0.05. A two-parameter Weibull distribution was used to calculate the critical shear bond strength corresponding to 5% probability of failure as a measure of system reliability. ANOVA revealed a significant decrease (p < 0.001) in the mean shear bond strength as follows: AH=CL=OS=G=E=OF>AD=IB=XE>PB=ADP, but no significant difference (p > 0.48) between the etch-and-rinse and self-etching adhesives. The corresponding characteristic bond strength of Weibull distribution ranged between 24.1 and 12.1 MPa, Weibull modulus between 8.3 and 2.1, and the critical shear bond strength varied from 16.0 to 3.0 MPa. Pronounced differences in the critical shear bond strength suggest reliability variations in the adhesive systems tested, which originate from chemical composition rather than type of adhesive.