Wojciech Uchman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wojciech Uchman has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Janusz Kotowicz
7 shared publications- Michał Jurczyk
Department of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland
6 shared publications Anna Skorek-Osikowska
5 shared publications- Jakub Ochmann
Department of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland
4 shared publications - Leszek Remiorz
Department of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland
3 shared publications - Łukasz Bartela
Department of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland
3 shared publications
Latest Publications
- Open Access
Sustainable Energy Transition Challenges: Limits to the Integration of Core Energy System Components—Reliability Perspective
The rapid expansion of non-dispatchable renewable energy sources (VRE) and energy storage technologies raises fundamental questions regarding the structural limits of their integration into power systems. This study aims to determine, from a structural reliability perspective, the adequate penetration limits of VRE in a synthetic power system and to assess how firm generation share, storage capacity, and wind–solar technology mix influence system reliability. A synthetic annual load profile reflecting current European conditions was developed from real-life data, along with a set of indicators enabling the consistent characterization and comparison of demand profiles. A deterministic system model was then applied to evaluate power and energy balance under parametrized configurations of firm generation, variable renewable capacity, and storage. Reliability performance was assessed using proposed indices (RIs) covering, among others, capacity margin, loss of load duration, frequency, etc. The results demonstrate the existence of structural penetration limits of non-dispatchable renewables that cannot be eliminated solely by increasing storage capacity, but only shifted. The technological composition of VRE is shown to be as important as total penetration: higher wind shares improve seasonal alignment and reduce reliability risks, whereas PV-dominated configurations increase curtailment and storage dependence. Moderate overcapacity, combined with a balanced wind–solar mix, provides the most favorable structural reliability conditions. These findings underscore the importance of incorporating reliability-based structural constraints into long-term energy transition planning, beyond purely economic optimization criteria.
Open AccessSustainable Energy Transition Challenges: Limits to the Integration of Core Energy System Components—Reliability Perspective
The rapid expansion of non-dispatchable renewable energy sources (VRE) and energy storage technologies raises fundamental questions regarding the structural limits of their integration into power systems. This study aims to determine, from a structural reliability perspective, the adequate penetration limits of VRE in a synthetic power system and to assess how firm generation share, storage capacity, and wind–solar technology mix influence system reliability. A synthetic annual load profile reflecting current European conditions was developed from real-life data, along with a set of indicators enabling the consistent characterization and comparison of demand profiles. A deterministic system model was then applied to evaluate power and energy balance under parametrized configurations of firm generation, variable renewable capacity, and storage. Reliability performance was assessed using proposed indices (RIs) covering, among others, capacity margin, loss of load duration, frequency, etc. The results demonstrate the existence of structural penetration limits of non-dispatchable renewables that cannot be eliminated solely by increasing storage capacity, but only shifted. The technological composition of VRE is shown to be as important as total penetration: higher wind shares improve seasonal alignment and reduce reliability risks, whereas PV-dominated configurations increase curtailment and storage dependence. Moderate overcapacity, combined with a balanced wind–solar mix, provides the most favorable structural reliability conditions. These findings underscore the importance of incorporating reliability-based structural constraints into long-term energy transition planning, beyond purely economic optimization criteria.
- Open Access
Designing a Thermoacoustic Cooler for Energy Applications: Experimental Insights
Thermoacoustic devices, such as refrigerators and heat pumps, present unique measurement challenges due to the simultaneous presence of rapidly fluctuating acoustic parameters and more stable thermal variables. Accurate and informative measurements during operation are crucial for developing effective control algorithms and optimizing performance under specific conditions. However, issues like inappropriate sampling frequencies and excessive data storage can lead to unintended averaging, compromising measurement quality. This study introduces a comprehensive experimental procedure aimed at enhancing the reliability of measurements in thermoacoustic systems. The approach encompasses meticulous experimental design, identification of measurement uncertainties and influencing factors during standard operation, and a statistical uncertainty analysis. Experimental findings reveal a significant reduction in temperature measurement uncertainty with increased thermoacoustic channel length and highlight the substantial impact of device structural features on performance. These insights are instrumental for refining measurement protocols and advancing the development of efficient thermoacoustic technologies.
Open AccessDesigning a Thermoacoustic Cooler for Energy Applications: Experimental Insights
Thermoacoustic devices, such as refrigerators and heat pumps, present unique measurement challenges due to the simultaneous presence of rapidly fluctuating acoustic parameters and more stable thermal variables. Accurate and informative measurements during operation are crucial for developing effective control algorithms and optimizing performance under specific conditions. However, issues like inappropriate sampling frequencies and excessive data storage can lead to unintended averaging, compromising measurement quality. This study introduces a comprehensive experimental procedure aimed at enhancing the reliability of measurements in thermoacoustic systems. The approach encompasses meticulous experimental design, identification of measurement uncertainties and influencing factors during standard operation, and a statistical uncertainty analysis. Experimental findings reveal a significant reduction in temperature measurement uncertainty with increased thermoacoustic channel length and highlight the substantial impact of device structural features on performance. These insights are instrumental for refining measurement protocols and advancing the development of efficient thermoacoustic technologies.
- Open Access
Review of Thermal Energy Storage Materials for Application in Large-Scale Integrated Energy Systems—Methodology for Matching Heat Storage Solutions for Given Applications
This article is a broad literature review of materials used and defined as potential for heat storage processes. Both single-phase and phase-change materials were considered. An important part of this paper is the definition of the toxicity of heat storage materials and other factors that disqualify their use depending on the application. Based on the literature analysis, a methodology was developed for selecting the optimal heat storage material depending on the typical parameters of the process and the method of heat transfer and storage. Based on the presented results, a solution was proposed for three temperature ranges: 100 °C (low-temperature storage), 300 °C (medium-temperature storage) and 500 °C (high-temperature storage). For all defined temperature levels, it is possible to adapt solid, liquid or phase-change materials for heat storage. However, it is essential to consider the characteristics of the specific system and to assess the advantages and disadvantages of the accumulation material used. Rock materials are characterised by similar thermophysical parameters and relatively low prices compared with their universality, while liquid energy storage allows for greater flexibility in power generation while maintaining the operational parameters of the heat source.
Open AccessReview of Thermal Energy Storage Materials for Application in Large-Scale Integrated Energy Systems—Methodology for Matching Heat Storage Solutions for Given Applications
This article is a broad literature review of materials used and defined as potential for heat storage processes. Both single-phase and phase-change materials were considered. An important part of this paper is the definition of the toxicity of heat storage materials and other factors that disqualify their use depending on the application. Based on the literature analysis, a methodology was developed for selecting the optimal heat storage material depending on the typical parameters of the process and the method of heat transfer and storage. Based on the presented results, a solution was proposed for three temperature ranges: 100 °C (low-temperature storage), 300 °C (medium-temperature storage) and 500 °C (high-temperature storage). For all defined temperature levels, it is possible to adapt solid, liquid or phase-change materials for heat storage. However, it is essential to consider the characteristics of the specific system and to assess the advantages and disadvantages of the accumulation material used. Rock materials are characterised by similar thermophysical parameters and relatively low prices compared with their universality, while liquid energy storage allows for greater flexibility in power generation while maintaining the operational parameters of the heat source.
- Open Access
Evaluation of the Diagnostic Sensitivity of Digital Vibration Sensors Based on Capacitive MEMS Accelerometers
In recent years, there has been an increasing use of digital vibration sensors that are based on capacitive MEMS accelerometers for machine vibration monitoring and diagnostics. These sensors simplify the design of monitoring and diagnostic systems, thus reducing implementation costs. However, it is important to understand how effective these digital sensors are in detecting rolling bearing faults. This article describes a method for determining the diagnostic sensitivity of diagnostic parameters provided by commercially available vibration sensors based on MEMS accelerometers. Experimental tests were conducted in laboratory conditions, during which vibrations from 11 healthy and faulty rolling bearings were measured using two commercial vibration sensors based on MEMS accelerometers and a piezoelectric accelerometer as a reference sensor. The results showed that the diagnostic sensitivity of the parameters depends on the upper-frequency band limit of the sensors, and the parameters most sensitive to the typical fatigue faults of rolling bearings are the peak and peak-to-peak amplitudes of vibration acceleration. Despite having a lower upper-frequency range compared to the piezoelectric accelerometer, the commercial vibration sensors were found to be sensitive to rolling bearing faults and can be successfully used in continuous monitoring and diagnostics systems for machines.
Open AccessEvaluation of the Diagnostic Sensitivity of Digital Vibration Sensors Based on Capacitive MEMS Accelerometers
In recent years, there has been an increasing use of digital vibration sensors that are based on capacitive MEMS accelerometers for machine vibration monitoring and diagnostics. These sensors simplify the design of monitoring and diagnostic systems, thus reducing implementation costs. However, it is important to understand how effective these digital sensors are in detecting rolling bearing faults. This article describes a method for determining the diagnostic sensitivity of diagnostic parameters provided by commercially available vibration sensors based on MEMS accelerometers. Experimental tests were conducted in laboratory conditions, during which vibrations from 11 healthy and faulty rolling bearings were measured using two commercial vibration sensors based on MEMS accelerometers and a piezoelectric accelerometer as a reference sensor. The results showed that the diagnostic sensitivity of the parameters depends on the upper-frequency band limit of the sensors, and the parameters most sensitive to the typical fatigue faults of rolling bearings are the peak and peak-to-peak amplitudes of vibration acceleration. Despite having a lower upper-frequency range compared to the piezoelectric accelerometer, the commercial vibration sensors were found to be sensitive to rolling bearing faults and can be successfully used in continuous monitoring and diagnostics systems for machines.
- Open Access
Solution for Post-Mining Sites: Thermo-Economic Analysis of a Large-Scale Integrated Energy Storage System
The intensive development of renewable energy sources and the decreasing efficiency of conventional energy sources are reducing the flexibility of the electric power system. It becomes necessary to develop energy storage systems that allow reducing the differences between generation and energy demand. This article presents a multivariant analysis of an adiabatic compressed air energy storage system. The system uses a post-mining shaft as a reservoir of compressed air and also as a location for the development of a heat storage tank. Consideration was given to the length of the discharge stage, which directly affects the capital expenditure and operating schedule of the system. The basis for the analyses was the in-house numerical model, which takes into account the variability of air parameters during system operation. The numerical model also includes calculations of Thermal Energy Storage’s transient performance. The energy efficiency of the system operating on a daily cycle varies from 67.9% to 70.3%. Various mechanisms for economic support of energy storage systems were analyzed. The levelized cost of storage varies, depending on the variant, from 75.86 EUR/MWh for the most favorable case to 223.24 EUR/MWh for the least favorable case.
Open AccessSolution for Post-Mining Sites: Thermo-Economic Analysis of a Large-Scale Integrated Energy Storage System
The intensive development of renewable energy sources and the decreasing efficiency of conventional energy sources are reducing the flexibility of the electric power system. It becomes necessary to develop energy storage systems that allow reducing the differences between generation and energy demand. This article presents a multivariant analysis of an adiabatic compressed air energy storage system. The system uses a post-mining shaft as a reservoir of compressed air and also as a location for the development of a heat storage tank. Consideration was given to the length of the discharge stage, which directly affects the capital expenditure and operating schedule of the system. The basis for the analyses was the in-house numerical model, which takes into account the variability of air parameters during system operation. The numerical model also includes calculations of Thermal Energy Storage’s transient performance. The energy efficiency of the system operating on a daily cycle varies from 67.9% to 70.3%. Various mechanisms for economic support of energy storage systems were analyzed. The levelized cost of storage varies, depending on the variant, from 75.86 EUR/MWh for the most favorable case to 223.24 EUR/MWh for the least favorable case.
- Open Access
- 25 May 2023
- Published by Elsevier in Applied Energy
- Vol. 344
Evaluation of the potential for distributed generation of green hydrogen using metal-hydride storage methods
- 25 May 2023
- Published by Elsevier in Applied Energy
- Vol. 344
Open AccessEvaluation of the potential for distributed generation of green hydrogen using metal-hydride storage methods
- Open Access
Assessment of Operational Performance for an Integrated ‘Power to Synthetic Natural Gas’ System
This article presents a power to SNG (synthetic natural gas) system that converts hydrogen into SNG via a methanation process. In our analysis, detailed models for all the elements of the system are built. We assume a direct connection between a wind farm and a hydrogen generator. For the purposes of our calculations, we also assume that the hydrogen generator is powered by the renewable source over a nine-hour period per day (between 21:00 and 06:00), and this corresponds to the off-peak period in energy demand. In addition, a hydrogen tank was introduced to maximize the operating time of the methanation reactor. The cooperation between the main components of the system were simulated using Matlab software. The primary aim of this paper is to assess the influence of various parameters on the operation of the proposed system, and to optimize its yearly operation via a consideration of the most important constraints. The analyses also examine different nominal power values of renewables from 8 to 12 MW and hydrogen generators from 3 to 6 MW. Implementing the proposed configuration, taking into account the direct connection of the hydrogen generator and the methanation reactor, showed that it had a positive effect on the dynamics and the operating times of the individual subsystems within the tested configuration.
Open AccessAssessment of Operational Performance for an Integrated ‘Power to Synthetic Natural Gas’ System
This article presents a power to SNG (synthetic natural gas) system that converts hydrogen into SNG via a methanation process. In our analysis, detailed models for all the elements of the system are built. We assume a direct connection between a wind farm and a hydrogen generator. For the purposes of our calculations, we also assume that the hydrogen generator is powered by the renewable source over a nine-hour period per day (between 21:00 and 06:00), and this corresponds to the off-peak period in energy demand. In addition, a hydrogen tank was introduced to maximize the operating time of the methanation reactor. The cooperation between the main components of the system were simulated using Matlab software. The primary aim of this paper is to assess the influence of various parameters on the operation of the proposed system, and to optimize its yearly operation via a consideration of the most important constraints. The analyses also examine different nominal power values of renewables from 8 to 12 MW and hydrogen generators from 3 to 6 MW. Implementing the proposed configuration, taking into account the direct connection of the hydrogen generator and the methanation reactor, showed that it had a positive effect on the dynamics and the operating times of the individual subsystems within the tested configuration.
- Open Access
- 1 November 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (79) , 39095-39107
Varying load distribution impacts on the operation of a hydrogen generator plant
- 1 November 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (79) , 39095-39107
Open AccessVarying load distribution impacts on the operation of a hydrogen generator plant
- 1 August 2021
- Published by Elsevier in Renewable Energy
- Vol. 174, 635-653
A system analysis of hybrid solar PTC-CPV absorber operation
- 1 August 2021
- Published by Elsevier in Renewable Energy
- Vol. 174, 635-653
A system analysis of hybrid solar PTC-CPV absorber operation