Gul Moonis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gul Moonis has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Amy F. Juliano
Harvard Medical School
6 shared publications - Daniel Thomas Ginat
Department of Radiology, University of Chicago, Chicago, IL
4 shared publications Prachi Dubey
Rhode Island Medical Imaging, Providence, Rhode Island
3 shared publications- Siddhant Dogra
Department of Radiology, New York University Langone Health, New York, USA
3 shared publications - Caroline D. Robson
Harvard Medical School
2 shared publications - Deborah R. Shatzkes
From the Department of Radiology, Northwell Lenox Hill Hospital, 100 E 77th St, New York, NY 10075 (R.S.); Zwanger-Pesiri Radiology, Lindenhurst, New York, NY (D.S.); Department of Radiology, Metro North Hospital and Health Service, Brisbane, Australia (J.G.); and Department of Neuroradiology, QScan Radiology, Queensland, Australia (J.G.).
2 shared publications
Latest Publications
- Open Access
- 16 May 2026
- Published by Edorium Journals Pvt. Ltd.
- Vol. 5 (1) , 6-11
In vivo and ex vivo interrogation of the spectral properties of a middle ear and mastoid cholesteatoma
Introduction: We sought to compare in vivo and ex vivo spectral properties of a recurrent middle ear and mastoid cholesteatoma. Case Report: A 25-year-old male with clinically suspected recurrent cholesteatoma four years after a canal wall up mastoidectomy was consented for the study. He underwent preoperative computed tomography (CT) imaging of the temporal bone on a Photon Counting CT scanner followed by right tympanomastoidectomy with cholesteatoma removal. The cholesteatoma specimen was separated into mastoid and middle ear samples that were packed in two centrifuge tubes and placed in a phantom to scan on a dual energy computed tomography (DECT) scanner. Following post-processing, regions-of-interest (ROIs) were placed on pre- and post-operative images and iodine densities were compared. On in vivo images, iodine densities were 0.9 mg/mL in a mastoid ROI, 0.3 mg/mL in an aditus ad antrum ROI, −0.7 mg/mL in a middle ear ROI and 0 mg/mL in a right cerebellar ROI (used as reference). On ex vivo images, iodine densities were 0.1 mg/mL in both the mastoid and tympanic specimens. Conclusion: In vivo cholesteatoma iodine densities differed based on location. The mastoid iodine density was higher than ex vivo cholesteatoma iodine densities, which may reflect a combination of beam hardening artifact on in vivo images, sample rinsing before transfer to the centrifuge tubes, and different scanners used for in vivo and ex vivo images. Additional research is needed to better understand variations in in vivo and ex vivo findings to facilitate accurate dual energy spectral analysis.
- 16 May 2026
- Published by Edorium Journals Pvt. Ltd.
- Vol. 5 (1) , 6-11
Open AccessIn vivo and ex vivo interrogation of the spectral properties of a middle ear and mastoid cholesteatoma
Introduction: We sought to compare in vivo and ex vivo spectral properties of a recurrent middle ear and mastoid cholesteatoma. Case Report: A 25-year-old male with clinically suspected recurrent cholesteatoma four years after a canal wall up mastoidectomy was consented for the study. He underwent preoperative computed tomography (CT) imaging of the temporal bone on a Photon Counting CT scanner followed by right tympanomastoidectomy with cholesteatoma removal. The cholesteatoma specimen was separated into mastoid and middle ear samples that were packed in two centrifuge tubes and placed in a phantom to scan on a dual energy computed tomography (DECT) scanner. Following post-processing, regions-of-interest (ROIs) were placed on pre- and post-operative images and iodine densities were compared. On in vivo images, iodine densities were 0.9 mg/mL in a mastoid ROI, 0.3 mg/mL in an aditus ad antrum ROI, −0.7 mg/mL in a middle ear ROI and 0 mg/mL in a right cerebellar ROI (used as reference). On ex vivo images, iodine densities were 0.1 mg/mL in both the mastoid and tympanic specimens. Conclusion: In vivo cholesteatoma iodine densities differed based on location. The mastoid iodine density was higher than ex vivo cholesteatoma iodine densities, which may reflect a combination of beam hardening artifact on in vivo images, sample rinsing before transfer to the centrifuge tubes, and different scanners used for in vivo and ex vivo images. Additional research is needed to better understand variations in in vivo and ex vivo findings to facilitate accurate dual energy spectral analysis.
- 12 March 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (4) , 879-889
Comprehensive Review of the Imaging of Adult Facial Nerve Reanimation
- 12 March 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (4) , 879-889
Comprehensive Review of the Imaging of Adult Facial Nerve Reanimation
- 7 February 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (8) , ajnr.A9205-2159
Multi-reader Comparison of Photon-Counting Detector CT Reconstructions for Evaluation of Temporal Bone Cochlear Implants
Photon-counting CT (PCCT) offers several advantages over conventional CT for cochlear implant (CI) imaging, including improved spatial resolution, and both signal-to-noise and contrast-to-noise ratios. However, the optimal PCCT reconstruction parameters for CI imaging has not been established. This study compared six PCCT reconstruction approaches for temporal bone CI imaging in a multi-reader design. 20 patients with CIs (24 implants) underwent temporal bone PCCT on a NAEOTOM Alpha scanner. Raw data was reconstructed using six different algorithms, as follows: Hr84 0.2mm T3D (head-regular, sharpness level 84, polyenergetic), Hr84 0.4mm T3D, Qr56 0.4mm iMAR T3D (quantitative-regular, sharpness level 56, iterative metal artifact reduction), Qr76 0.4mm M_140 (virtual monoenergetic 140 keV), Qr76 0.4mm M_70 (virtual monoenergetic 70 keV), and Qr76 0.4mm T3D.Two fellowship-trained neuroradiologists independently rated electrode visibility and overall image quality for all implants, and wire visibility for implants with visible wires, on 0-2 Likert scales. Inter-reader agreement was assessed with quadratic weighted Cohen's kappa. A mixed effects model was used to evaluate reconstruction differences for each metric. Mean patient age was 50.9 ± 26 years; 8 were women. Inter-reader agreement was substantial for electrode visibility (κ = 0.66) and overall image quality (κ = 0.79), and moderate for wire visibility (κ = 0.52). Reconstruction type significantly affected all three metrics. The sharp kernel reconstructions (Hr84 0.2mm T3D and Hr84 0.4mm T3D) consistently ranked highest, with significantly greater scores than most other reconstructions. Qr56 0.4mm iMAR T3D was the lowest rated in every category, significantly worse than all other reconstructions. PCCT reconstruction parameters substantially influence postoperative CI image quality. Ultra-high-resolution reconstructions provided the best combination of artifact suppression and fine structural detail, while iterative MAR and high-keV monoenergetic reconstructions performed the worst. These findings can guide reconstruction selection to optimize PCCT protocols for CI evaluation.
- 7 February 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (8) , ajnr.A9205-2159
Multi-reader Comparison of Photon-Counting Detector CT Reconstructions for Evaluation of Temporal Bone Cochlear Implants
Photon-counting CT (PCCT) offers several advantages over conventional CT for cochlear implant (CI) imaging, including improved spatial resolution, and both signal-to-noise and contrast-to-noise ratios. However, the optimal PCCT reconstruction parameters for CI imaging has not been established. This study compared six PCCT reconstruction approaches for temporal bone CI imaging in a multi-reader design. 20 patients with CIs (24 implants) underwent temporal bone PCCT on a NAEOTOM Alpha scanner. Raw data was reconstructed using six different algorithms, as follows: Hr84 0.2mm T3D (head-regular, sharpness level 84, polyenergetic), Hr84 0.4mm T3D, Qr56 0.4mm iMAR T3D (quantitative-regular, sharpness level 56, iterative metal artifact reduction), Qr76 0.4mm M_140 (virtual monoenergetic 140 keV), Qr76 0.4mm M_70 (virtual monoenergetic 70 keV), and Qr76 0.4mm T3D.Two fellowship-trained neuroradiologists independently rated electrode visibility and overall image quality for all implants, and wire visibility for implants with visible wires, on 0-2 Likert scales. Inter-reader agreement was assessed with quadratic weighted Cohen's kappa. A mixed effects model was used to evaluate reconstruction differences for each metric. Mean patient age was 50.9 ± 26 years; 8 were women. Inter-reader agreement was substantial for electrode visibility (κ = 0.66) and overall image quality (κ = 0.79), and moderate for wire visibility (κ = 0.52). Reconstruction type significantly affected all three metrics. The sharp kernel reconstructions (Hr84 0.2mm T3D and Hr84 0.4mm T3D) consistently ranked highest, with significantly greater scores than most other reconstructions. Qr56 0.4mm iMAR T3D was the lowest rated in every category, significantly worse than all other reconstructions. PCCT reconstruction parameters substantially influence postoperative CI image quality. Ultra-high-resolution reconstructions provided the best combination of artifact suppression and fine structural detail, while iterative MAR and high-keV monoenergetic reconstructions performed the worst. These findings can guide reconstruction selection to optimize PCCT protocols for CI evaluation.
- 10 November 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (1) , 117-122
Management of Incidentally Discovered Pineal Cyst on CT and MRI: Recommendations from the ACR Incidental Findings Committee
- 10 November 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (1) , 117-122
Management of Incidentally Discovered Pineal Cyst on CT and MRI: Recommendations from the ACR Incidental Findings Committee
- 27 July 2025
- Published by Springer Nature
- p. 169-184
Imaging of Neck and Facial Infections
- 13 June 2025
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (1) , 46-53
Neuroimaging Applications of Photon-counting CT
Photon-counting computed tomography (PCCT) is a new imaging technology that has advanced diagnostic imaging by offering improved spatial and contrast resolution as well as novel spectral imaging capabilities. Unlike conventional CT, which uses energy-integrating detectors, PCCT employs photon-counting detectors that directly measure individual photon energies, enabling applications such as virtual monochromatic imaging (VMI) and material decomposition. These innovations allow for artifact reduction, better visualization of fine anatomic structures, and improved diagnostic accuracy, all while reducing radiation dose. This review explores select applications of PCCT in neuroimaging, focusing on the brain, temporal bone, and spine. In the brain, we discuss how PCCT demonstrates superior performance for evaluating aneurysms, metallic prostheses, and vessel stenosis, offering enhanced visualization of vascular structures and minimizing artifacts. For temporal bone imaging, we review assessment of both complex anatomy and potentially subtle pathologies such as otosclerosis, as well as visualization of implants like cochlear devices and their intricate components. In spinal imaging, we explore how PCCT improves precise detection of causes of cerebrospinal fluid leaks, improves localization of tiny vessels such as the artery of Adamkiewicz and spinal dural arteriovenous fistulas, and reduces metal artifacts associated with postoperative hardware. PCCT addresses limitations of conventional CT while unlocking new diagnostic possibilities across neuroimaging applications. As clinical adoption of PCCT grows, ongoing research and development will refine imaging protocols and expand its utility. The accumulating evidence underscores PCCT’s transformative potential to improve diagnostic confidence in neuroimaging and beyond. Export
- 13 June 2025
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (1) , 46-53
Neuroimaging Applications of Photon-counting CT
Photon-counting computed tomography (PCCT) is a new imaging technology that has advanced diagnostic imaging by offering improved spatial and contrast resolution as well as novel spectral imaging capabilities. Unlike conventional CT, which uses energy-integrating detectors, PCCT employs photon-counting detectors that directly measure individual photon energies, enabling applications such as virtual monochromatic imaging (VMI) and material decomposition. These innovations allow for artifact reduction, better visualization of fine anatomic structures, and improved diagnostic accuracy, all while reducing radiation dose. This review explores select applications of PCCT in neuroimaging, focusing on the brain, temporal bone, and spine. In the brain, we discuss how PCCT demonstrates superior performance for evaluating aneurysms, metallic prostheses, and vessel stenosis, offering enhanced visualization of vascular structures and minimizing artifacts. For temporal bone imaging, we review assessment of both complex anatomy and potentially subtle pathologies such as otosclerosis, as well as visualization of implants like cochlear devices and their intricate components. In spinal imaging, we explore how PCCT improves precise detection of causes of cerebrospinal fluid leaks, improves localization of tiny vessels such as the artery of Adamkiewicz and spinal dural arteriovenous fistulas, and reduces metal artifacts associated with postoperative hardware. PCCT addresses limitations of conventional CT while unlocking new diagnostic possibilities across neuroimaging applications. As clinical adoption of PCCT grows, ongoing research and development will refine imaging protocols and expand its utility. The accumulating evidence underscores PCCT’s transformative potential to improve diagnostic confidence in neuroimaging and beyond. Export
- Open Access
- 11 March 2025
- Published by Springer Nature
- p. C1
Correction to: What Radiology Residents Need to Know: Neuroradiology
- 11 March 2025
- Published by Springer Nature
- p. C1
Open AccessCorrection to: What Radiology Residents Need to Know: Neuroradiology
- 26 November 2024
- Published by Springer Nature
- p. 95-107
Mastoiditis
- 2 November 2024
- Published by Springer Nature
- p. 445-464
Posterior Skull Base
- 1 November 2024
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1802-1812
A review of applications of photon-counting computed tomography in head and neck imaging
Photon-counting CT (PCCT), approved for clinical practice for over 2 years now, both improves on features of conventional energy-integrating detector (EID)-CT and introduces new capabilities such as multienergy acquisition. PCCT is already transforming all domains of radiology, including head and neck imaging, and will become increasingly utilized in the approaching years. In this review, we first concisely explain the key physical principles distinguishing PCCT from EID-CT. We then discuss how the underlying physics leads to the novel features associated with PCCT, focusing on improved artefact reduction, spatial resolution, contrast-to-noise ratio, as well as multienergy acquisition and reduced contrast and radiation doses. Next, we review head and neck PCCT applications and comparison to EID-CT in dental imaging, sinus imaging, temporal bone, tumour imaging, and vascular imaging. Within the temporal bone applications, we explore normal anatomy, pathologic anatomy, and the appearance of prostheses and implants. Representative imaging is provided to highlight differences between PCCT and EID-CT. Finally, we highlight areas of ongoing research in PCCT.
- 1 November 2024
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1802-1812
A review of applications of photon-counting computed tomography in head and neck imaging
Photon-counting CT (PCCT), approved for clinical practice for over 2 years now, both improves on features of conventional energy-integrating detector (EID)-CT and introduces new capabilities such as multienergy acquisition. PCCT is already transforming all domains of radiology, including head and neck imaging, and will become increasingly utilized in the approaching years. In this review, we first concisely explain the key physical principles distinguishing PCCT from EID-CT. We then discuss how the underlying physics leads to the novel features associated with PCCT, focusing on improved artefact reduction, spatial resolution, contrast-to-noise ratio, as well as multienergy acquisition and reduced contrast and radiation doses. Next, we review head and neck PCCT applications and comparison to EID-CT in dental imaging, sinus imaging, temporal bone, tumour imaging, and vascular imaging. Within the temporal bone applications, we explore normal anatomy, pathologic anatomy, and the appearance of prostheses and implants. Representative imaging is provided to highlight differences between PCCT and EID-CT. Finally, we highlight areas of ongoing research in PCCT.