Salih Zeki Bas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Salih Zeki Bas has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Ozmen
Department of Chemistry, Faculty of Science, University of Selcuk, 42250, Konya, Turkey
7 shared publications - Keziban Atacan
Department of Engineering Fundamental Sciences, Faculty of Technology, Sakarya University of Applied Sciences, Serdivan, Türkiye
3 shared publications - Faruk Ozel
Department of Department of Mechanical Engineering, Recep Tayyip Erdoğan University, 53100, Rize, Türkiye
2 shared publications Handan Gülce
Department of Chemical Engineering , Selcuk University , Konya , Turkey
2 shared publicationsKeziban Atacan
Biomedical, Magnetic and Semiconductor Materials Application and Research Center (BIMAS-RC), Sakarya University, Sakarya, Turkey
2 shared publicationsAdem Sarilmaz
Department of Metallurgical and Materials Engineering, Karamanoglu Mehmetbey University, 70200, Karaman, Turkey
1 shared publication
Latest Publications
- 30 March 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (9) , 2159-2169
A new sensing platform based on a ternary nanocomposite of graphitic carbon nitride–silver sulfide–nickel molybdate for quercetin determination
In this study, we have shown how to prepare a ternary nanocomposite (Ag2S–NiMoO4–g-C3N4) consisting of graphitic carbon nitride (g-C3N4) nanosheets, silver sulfide (Ag2S) nanocrystals, and nickel molybdate (NiMoO4) nanorods and its sensing ability to detect quercetin, a flavonoid found in many fruits and vegetables. An Ag2S–NiMoO4–g-C3N4 nanocomposite-modified screen-printed electrode (SPE) exhibited remarkable sensing performance in a quercetin (Que) concentration range of 0.005 μM–20 μM with a low detection limit of 2.7 nM. Moreover, we have aimed at improving the selectivity and sensitivity of a sensor for detecting Que by optimizing the composition of Ag2S–NiMoO4–g-C3N4, the film thickness, and the electrolyte pH. The sensor's selectivity for Que was tested in the presence of potential interferents such as ascorbic acid, citric acid, fructose, glucose, lactose, maltose, mannose, sucrose, and tyrosine. The performance of the sensor was tested on a variety of food samples, including green apple, green tea, honey, and red onion skin.
- 30 March 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (9) , 2159-2169
A new sensing platform based on a ternary nanocomposite of graphitic carbon nitride–silver sulfide–nickel molybdate for quercetin determination
In this study, we have shown how to prepare a ternary nanocomposite (Ag2S–NiMoO4–g-C3N4) consisting of graphitic carbon nitride (g-C3N4) nanosheets, silver sulfide (Ag2S) nanocrystals, and nickel molybdate (NiMoO4) nanorods and its sensing ability to detect quercetin, a flavonoid found in many fruits and vegetables. An Ag2S–NiMoO4–g-C3N4 nanocomposite-modified screen-printed electrode (SPE) exhibited remarkable sensing performance in a quercetin (Que) concentration range of 0.005 μM–20 μM with a low detection limit of 2.7 nM. Moreover, we have aimed at improving the selectivity and sensitivity of a sensor for detecting Que by optimizing the composition of Ag2S–NiMoO4–g-C3N4, the film thickness, and the electrolyte pH. The sensor's selectivity for Que was tested in the presence of potential interferents such as ascorbic acid, citric acid, fructose, glucose, lactose, maltose, mannose, sucrose, and tyrosine. The performance of the sensor was tested on a variety of food samples, including green apple, green tea, honey, and red onion skin.
- 3 February 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (6) , 1664-1673
A lab-made screen-printed sensing strip for sensitive and selective electrochemical detection of butylated hydroxyanisole
This study describes the fabrication of a lab-made screen-printed electrode (LabSPE) and its sensing ability for the detection of butylated hydroxyanisole (BHA) which is a synthetic antioxidant utilized widely in food industries. The lab-made screen-printed electrodes were printed on a polycarbonate substrate stepwise via a screen-printing technique using various inks suitable for electrode templates and then modified for the detection of BHA. As for the design of the sensor, firstly, graphitic carbon nitride (g-C3N4) was synthesized electrochemically through the one-pot synthesis method. After the synthesis of Fe3O4 nanoparticles (Fe3O4 NPs), the surface of SPE was modified with the dual composite consisting of g-C3N4 and Fe3O4 NPs. Lastly, platinum nanoparticles (Pt NPs) were deposited electrochemically on the modified electrode in 0.5 M HCl solution containing 2 mM H2PtCl6 at a constant potential of 0.25 V for 45 s. After optimization of varied parameters such as pH of the electrolyte solution, deposition time, and deposition potential, the current responses of the sensor (Pt/g-C3N4–Fe3O4/LabSPE) toward BHA displayed linearity in the wide concentration range of 0.25 μM to 90 μM with a low detection limit of 0.053 μM. The selectivity of Pt/g-C3N4–Fe3O4/SPE was tested successfully in the presence of other antioxidants (BHT, TBHQ, GA, and PG). Moreover, the applicability of the proposed sensor for practical tests was verified by the detection of BHA in commercial samples.
- 3 February 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (6) , 1664-1673
A lab-made screen-printed sensing strip for sensitive and selective electrochemical detection of butylated hydroxyanisole
This study describes the fabrication of a lab-made screen-printed electrode (LabSPE) and its sensing ability for the detection of butylated hydroxyanisole (BHA) which is a synthetic antioxidant utilized widely in food industries. The lab-made screen-printed electrodes were printed on a polycarbonate substrate stepwise via a screen-printing technique using various inks suitable for electrode templates and then modified for the detection of BHA. As for the design of the sensor, firstly, graphitic carbon nitride (g-C3N4) was synthesized electrochemically through the one-pot synthesis method. After the synthesis of Fe3O4 nanoparticles (Fe3O4 NPs), the surface of SPE was modified with the dual composite consisting of g-C3N4 and Fe3O4 NPs. Lastly, platinum nanoparticles (Pt NPs) were deposited electrochemically on the modified electrode in 0.5 M HCl solution containing 2 mM H2PtCl6 at a constant potential of 0.25 V for 45 s. After optimization of varied parameters such as pH of the electrolyte solution, deposition time, and deposition potential, the current responses of the sensor (Pt/g-C3N4–Fe3O4/LabSPE) toward BHA displayed linearity in the wide concentration range of 0.25 μM to 90 μM with a low detection limit of 0.053 μM. The selectivity of Pt/g-C3N4–Fe3O4/SPE was tested successfully in the presence of other antioxidants (BHT, TBHQ, GA, and PG). Moreover, the applicability of the proposed sensor for practical tests was verified by the detection of BHA in commercial samples.
- 24 May 2022
- Published by Wiley in ChemElectroChem
- Vol. 9 (10)
Block Copolymer Templated WO3 Surface Nanolines as Catalysts for Enhanced Epinephrine Sensing and the Oxygen Evolution Reaction
We report the development of a multifunctional, nanostructured tungsten oxide catalytic device using block copolymer (BCP) templating, which was utilised for both the oxygen evolution reaction (OER) and epinephrine (EP) detection. The device was constructed by depositing a self‐assembled BCP film atop an indium tin oxide (ITO) substrate. A tungsten precursor was then selectively coordinated into the film via liquid phase infiltration, which upon UV‐ozone treatment yielded WO3 surface nanolines (NLs) with excellent surface coverage. The resulting device was firstly investigated as a photoanode for OER. The onset overpotential of the WO3NLs‐ITO electrode was determined to be 240 mV and 390 mV, with and without light illumination, respectively. Moreover, the applicability of the WO3NLs‐ITO device for the electrochemical sensing of EP was explored using cyclic voltammetry and amperometry, exhibiting a linear response in a wide working range of 0.5–250 μM with a sensitivity of 0.0491 μA μM−1 and detection limit of 0.086 μM. The device demonstrated high durability over multiple EP measurements, as well as strong anti‐interference abilities versus well‐known interfering compounds. Additionally, the device was successfully applied to accurately determine EP concentrations in commercial drug samples. The results of this study attest to the significant potential of BCP templating for developing low cost, high‐performance electrocatalytic devices for future nanomanufacturing strategies.
- 24 May 2022
- Published by Wiley in ChemElectroChem
- Vol. 9 (10)
Block Copolymer Templated WO3 Surface Nanolines as Catalysts for Enhanced Epinephrine Sensing and the Oxygen Evolution Reaction
We report the development of a multifunctional, nanostructured tungsten oxide catalytic device using block copolymer (BCP) templating, which was utilised for both the oxygen evolution reaction (OER) and epinephrine (EP) detection. The device was constructed by depositing a self‐assembled BCP film atop an indium tin oxide (ITO) substrate. A tungsten precursor was then selectively coordinated into the film via liquid phase infiltration, which upon UV‐ozone treatment yielded WO3 surface nanolines (NLs) with excellent surface coverage. The resulting device was firstly investigated as a photoanode for OER. The onset overpotential of the WO3NLs‐ITO electrode was determined to be 240 mV and 390 mV, with and without light illumination, respectively. Moreover, the applicability of the WO3NLs‐ITO device for the electrochemical sensing of EP was explored using cyclic voltammetry and amperometry, exhibiting a linear response in a wide working range of 0.5–250 μM with a sensitivity of 0.0491 μA μM−1 and detection limit of 0.086 μM. The device demonstrated high durability over multiple EP measurements, as well as strong anti‐interference abilities versus well‐known interfering compounds. Additionally, the device was successfully applied to accurately determine EP concentrations in commercial drug samples. The results of this study attest to the significant potential of BCP templating for developing low cost, high‐performance electrocatalytic devices for future nanomanufacturing strategies.
- 25 November 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (1) , 67-75
An electrochemical sensor based on a Co 3 O 4 –ERGO nanocomposite modified screen-printed electrode for detection of uric acid in artificial saliva
The schematic illustration shows the Co 3 O 4 –ERGO/SPE sensor and electro-oxidation mechanism of uric acid. The present sensor allows for quick and simple detection of UA in a few drops of a saliva sample as well as point-of-care testing.
- 25 November 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (1) , 67-75
An electrochemical sensor based on a Co 3 O 4 –ERGO nanocomposite modified screen-printed electrode for detection of uric acid in artificial saliva
The schematic illustration shows the Co 3 O 4 –ERGO/SPE sensor and electro-oxidation mechanism of uric acid. The present sensor allows for quick and simple detection of UA in a few drops of a saliva sample as well as point-of-care testing.
- 1 August 2021
- Published by Elsevier in Electrochimica Acta
- Vol. 386
A comparison study of MFe2O4 (M: Ni, Cu, Zn)-reduced graphene oxide nanocomposite for electrochemical detection of bisphenol A
- 1 August 2021
- Published by Elsevier in Electrochimica Acta
- Vol. 386
A comparison study of MFe2O4 (M: Ni, Cu, Zn)-reduced graphene oxide nanocomposite for electrochemical detection of bisphenol A
- 15 June 2020
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 44 (27) , 11759-11767
Design of a new electrochemical sensing system based on MoS 2 –TiO 2 /reduced graphene oxide nanocomposite for the detection of paracetamol
Synthetic route for the MoS 2 –TiO 2 /rGO nanocomposite and the electrode reaction for paracetamol.
- 15 June 2020
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 44 (27) , 11759-11767
Design of a new electrochemical sensing system based on MoS 2 –TiO 2 /reduced graphene oxide nanocomposite for the detection of paracetamol
Synthetic route for the MoS 2 –TiO 2 /rGO nanocomposite and the electrode reaction for paracetamol.
- 13 December 2019
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (4) , 499-506
An Ag–TiO 2 –reduced graphene oxide hybrid film for electrochemical detection of 8-hydroxy-2′-deoxyguanosine as an oxidative DNA damage biomarker
Here, a notably sensitive and selective electrochemical sensor based on an Ag–TiO 2 –rGO hybrid nanomaterial modified SPE was developed for 8-OHdG detection, which is a significant DNA biomarker due to one of the main products of oxidative DNA damage.
- 13 December 2019
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (4) , 499-506
An Ag–TiO 2 –reduced graphene oxide hybrid film for electrochemical detection of 8-hydroxy-2′-deoxyguanosine as an oxidative DNA damage biomarker
Here, a notably sensitive and selective electrochemical sensor based on an Ag–TiO 2 –rGO hybrid nanomaterial modified SPE was developed for 8-OHdG detection, which is a significant DNA biomarker due to one of the main products of oxidative DNA damage.
- 18 August 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (19) , 7752-7759
A gold nanoparticle functionalized multiwalled carbon nanotube–poly(o-phenylenediamine) composite film for glucose biosensing applications
A new biosensor based on immobilization of glucose oxidase on a multiwalled carbon nanotube–gold nanoparticle coated glassy carbon electrode (GCE) was fabricated for the electrochemical determination of glucose. First, a carboxylated multiwalled carbon nanotube (cMWCNT) was functionalized with 4-aminothiophenol (ATP) by a coupling agent, N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride, and then gold nanoparticles (AuNPs) were covalently linked to the ATP–cMWCNT via the formation of a covalent Au–S bond. Finally, glucose oxidase was immobilized simultaneously by the electropolymerization of o-phenylenediamine on the AuNP–ATP–cMWCNT coated GCE. The biosensor showed a linear range from 0.05 mM to 8.85 mM with a sensitivity of 27.93 μA mM−1 cm−2 and a detection limit of 0.015 mM for the detection of glucose. The biosensor was successfully applied to estimate the glucose concentration in human blood serum samples. Furthermore, the AuNP–ATP–cMWCNT was investigated for the non-enzymatic detection of hydrogen peroxide by using voltammetric and amperometric techniques, indicating a linear relationship in the range of 5 × 10−3 to 13.10 mM.
- 18 August 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (19) , 7752-7759
A gold nanoparticle functionalized multiwalled carbon nanotube–poly(o-phenylenediamine) composite film for glucose biosensing applications
A new biosensor based on immobilization of glucose oxidase on a multiwalled carbon nanotube–gold nanoparticle coated glassy carbon electrode (GCE) was fabricated for the electrochemical determination of glucose. First, a carboxylated multiwalled carbon nanotube (cMWCNT) was functionalized with 4-aminothiophenol (ATP) by a coupling agent, N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride, and then gold nanoparticles (AuNPs) were covalently linked to the ATP–cMWCNT via the formation of a covalent Au–S bond. Finally, glucose oxidase was immobilized simultaneously by the electropolymerization of o-phenylenediamine on the AuNP–ATP–cMWCNT coated GCE. The biosensor showed a linear range from 0.05 mM to 8.85 mM with a sensitivity of 27.93 μA mM−1 cm−2 and a detection limit of 0.015 mM for the detection of glucose. The biosensor was successfully applied to estimate the glucose concentration in human blood serum samples. Furthermore, the AuNP–ATP–cMWCNT was investigated for the non-enzymatic detection of hydrogen peroxide by using voltammetric and amperometric techniques, indicating a linear relationship in the range of 5 × 10−3 to 13.10 mM.
- 13 March 2014
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 131 (16)
Design of a probe based on poly(glycidyl methacrylate‐co‐vinylferrocene)‐coated Pt electrode for electrochemical detection of PTEN gene in PCR amplified samples from prostate tissues
In this study, a new probe based on immobilization of amino linked oligonucleotide (NH2‐linked DNA) on poly(glycidyl methacrylate‐co‐vinylferrocene)‐coated Pt electrode was fabricated for the electrochemical detection of PTEN gene from human prostate tissues. The experimental parameters such as DNA immobilization time, DNA concentration, and target concentration were optimized. The selectivity of the NH2‐linked DNA probe was assessed with mismatch (MM) and noncomplementary (NC) sequences. The applicability of the NH2‐linked DNA probe to the PCR amplified samples correspond to PTEN gene from prostate tissues was evaluated. The immobilization of DNA on the copolymer was confirmed by FTIR, AFM, CV and DPV analysis. The PCR products were also identified by using agarose gel electrophoresis. The prepared probe indicated a linear range (10–100 μg mL−1) with a detection limit (4.7 μg mL−1) and a good selectivity of the NH2‐linked DNA probe toward target DNA sequence. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014, 131, 40638.
- 13 March 2014
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 131 (16)
Design of a probe based on poly(glycidyl methacrylate‐co‐vinylferrocene)‐coated Pt electrode for electrochemical detection of PTEN gene in PCR amplified samples from prostate tissues
In this study, a new probe based on immobilization of amino linked oligonucleotide (NH2‐linked DNA) on poly(glycidyl methacrylate‐co‐vinylferrocene)‐coated Pt electrode was fabricated for the electrochemical detection of PTEN gene from human prostate tissues. The experimental parameters such as DNA immobilization time, DNA concentration, and target concentration were optimized. The selectivity of the NH2‐linked DNA probe was assessed with mismatch (MM) and noncomplementary (NC) sequences. The applicability of the NH2‐linked DNA probe to the PCR amplified samples correspond to PTEN gene from prostate tissues was evaluated. The immobilization of DNA on the copolymer was confirmed by FTIR, AFM, CV and DPV analysis. The PCR products were also identified by using agarose gel electrophoresis. The prepared probe indicated a linear range (10–100 μg mL−1) with a detection limit (4.7 μg mL−1) and a good selectivity of the NH2‐linked DNA probe toward target DNA sequence. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014, 131, 40638.