Gang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gang Zhang has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Yuhang Ding
6 shared publications- Shichao Wang
School of Highway, Chang’an University, Xi’an 710064, China
5 shared publications - Chaojie Song
School of Highway, Chang’an University, Xi’an, China
3 shared publications Feng Xu
3 shared publicationsShichao Wang
Chang’an University
3 shared publicationsShuanhai He
School of Highway, Chang’an University, Xi’an, China
3 shared publications
Latest Publications
- Open Access
Behavior of Suspension Bridge Exposed to Oil-Tanker Fire
This paper presents an investigation into the structural behavior of a suspension bridge exposed to an oil-tanker-truck fire. A coupled CFD-FEM analysis model is established to incorporate realistic oil-tanker fire scenarios and multiscale thermo-mechanical coupling, allowing the local thermal responses of critical components and global structural behavior of the suspension bridge to be captured within a unified framework. This model is validated to investigate thermal and structural responses on suspension bridges under different fire exposure lengths and locations influenced by transverse wind. Herein, this response embraces temperature rise, deflection progression, stress evolution in the main cable, force redistribution of hangers, and global failure evolution. Thereafter, failure assessment methods for main cables and hangers in suspension bridges exposed to oil-tanker-truck fires are proposed. The predominant results indicate that crosswind causes the flame to tilt toward and even fully envelop the main cable. Rapid temperature rise along the circumference of the main cable accelerates the degradation of cable load-carrying capacity, eventually leading to main cable rupture and global collapse of the suspension bridge. The proposed main-cable failure assessment method, based on fire exposure duration and surface temperature, can rapidly estimate the fire-resistance limit of main cables. Ruptured hangers lead to upward jumping of deflection in the main cable and a downward deflecting of the main girder. Force redistribution to adjacent hangers may trigger successive ruptures, and the force-based assessment method effectively evaluates the progressive collapse of a suspension bridge subjected to an oil-tanker-truck fire.
Open AccessBehavior of Suspension Bridge Exposed to Oil-Tanker Fire
This paper presents an investigation into the structural behavior of a suspension bridge exposed to an oil-tanker-truck fire. A coupled CFD-FEM analysis model is established to incorporate realistic oil-tanker fire scenarios and multiscale thermo-mechanical coupling, allowing the local thermal responses of critical components and global structural behavior of the suspension bridge to be captured within a unified framework. This model is validated to investigate thermal and structural responses on suspension bridges under different fire exposure lengths and locations influenced by transverse wind. Herein, this response embraces temperature rise, deflection progression, stress evolution in the main cable, force redistribution of hangers, and global failure evolution. Thereafter, failure assessment methods for main cables and hangers in suspension bridges exposed to oil-tanker-truck fires are proposed. The predominant results indicate that crosswind causes the flame to tilt toward and even fully envelop the main cable. Rapid temperature rise along the circumference of the main cable accelerates the degradation of cable load-carrying capacity, eventually leading to main cable rupture and global collapse of the suspension bridge. The proposed main-cable failure assessment method, based on fire exposure duration and surface temperature, can rapidly estimate the fire-resistance limit of main cables. Ruptured hangers lead to upward jumping of deflection in the main cable and a downward deflecting of the main girder. Force redistribution to adjacent hangers may trigger successive ruptures, and the force-based assessment method effectively evaluates the progressive collapse of a suspension bridge subjected to an oil-tanker-truck fire.
- Open Access
Fire Performance Study of Through Concrete-Filled Steel Tubular Arch Bridges
Advancing rapidly in modern bridge engineering technology, through concrete-filled steel tubular (CFST) arch bridges have achieved widespread application in transportation infrastructure development. Nevertheless, vehicle fires occurring in complicated operational settings may rapidly escalate into major disasters. Fires in oil tankers are particularly dangerous for the safety of bridges. This study examines the fire resistance of through concrete-filled steel tubular (CFST) arch bridges exposed to tanker truck fires. The study formulates a detailed model utilizing Fire Dynamics Simulator (FDS) to simulate fire scenarios, elucidating the spatial temperature distribution characteristics within arch bridge structures. A three-dimensional finite element model established in ABAQUS (Abaqus 2024, Dassault Systèmes Simulia Corp, Providence, RI, USA) is employed to simulate structural responses by analyzing the mechanical behavior of key components under different fire conditions. Practical fire resistance design recommendations for extreme tanker truck fire scenarios are ultimately proposed. Numerical results demonstrate that structural components near the fire source (such as transverse bracings, hangers, and fire-exposed arch surfaces) experience significantly higher temperatures than other regions. Notable temperature gradients developing along hangers and arch ribs in fire-affected zones are observed, while substantial cross-sectional temperature gradients occurring in these components under tanker truck fires reveal their damage evolution mechanisms. The fire exposure scenario at the quarter-point of the midspan is identified as the most critical fire exposure scenario for through CFST arch bridges under tanker truck fires. Under this extreme scenario, the deflection on the fire-exposed side of the global structure exhibits a significant three-stage distribution characteristic: an initial ascending phase around 0–800 s, followed by a sharp descending phase during 800–1100 s, and then a stabilization trend. A fire resistance limit criterion based on component failure ( = 853.43 s) is established, and a global fire resistance limit assessment methodology for through CFST arch bridges under extreme tanker truck scenarios is proposed.Open AccessFire Performance Study of Through Concrete-Filled Steel Tubular Arch Bridges
Advancing rapidly in modern bridge engineering technology, through concrete-filled steel tubular (CFST) arch bridges have achieved widespread application in transportation infrastructure development. Nevertheless, vehicle fires occurring in complicated operational settings may rapidly escalate into major disasters. Fires in oil tankers are particularly dangerous for the safety of bridges. This study examines the fire resistance of through concrete-filled steel tubular (CFST) arch bridges exposed to tanker truck fires. The study formulates a detailed model utilizing Fire Dynamics Simulator (FDS) to simulate fire scenarios, elucidating the spatial temperature distribution characteristics within arch bridge structures. A three-dimensional finite element model established in ABAQUS (Abaqus 2024, Dassault Systèmes Simulia Corp, Providence, RI, USA) is employed to simulate structural responses by analyzing the mechanical behavior of key components under different fire conditions. Practical fire resistance design recommendations for extreme tanker truck fire scenarios are ultimately proposed. Numerical results demonstrate that structural components near the fire source (such as transverse bracings, hangers, and fire-exposed arch surfaces) experience significantly higher temperatures than other regions. Notable temperature gradients developing along hangers and arch ribs in fire-affected zones are observed, while substantial cross-sectional temperature gradients occurring in these components under tanker truck fires reveal their damage evolution mechanisms. The fire exposure scenario at the quarter-point of the midspan is identified as the most critical fire exposure scenario for through CFST arch bridges under tanker truck fires. Under this extreme scenario, the deflection on the fire-exposed side of the global structure exhibits a significant three-stage distribution characteristic: an initial ascending phase around 0–800 s, followed by a sharp descending phase during 800–1100 s, and then a stabilization trend. A fire resistance limit criterion based on component failure ( = 853.43 s) is established, and a global fire resistance limit assessment methodology for through CFST arch bridges under extreme tanker truck scenarios is proposed. - 10 October 2025
- Published by Elsevier in Engineering Structures
- Vol. 345
Fire resistance of steel truss-concrete composite bridge girders: Experimental study and case analysis
- 10 October 2025
- Published by Elsevier in Engineering Structures
- Vol. 345
Fire resistance of steel truss-concrete composite bridge girders: Experimental study and case analysis
- 1 October 2025
- Published by Elsevier in Engineering Structures
- Vol. 345
A method for investigating the responses of cable-stayed bridge exposed to distinctive tank truck fires
- 1 October 2025
- Published by Elsevier in Engineering Structures
- Vol. 345
A method for investigating the responses of cable-stayed bridge exposed to distinctive tank truck fires
- Open Access
Study on Residual Load-Bearing Capacity of Composite Steel Truss Bridge Girders After Vehicle Fire
To investigate the residual load-bearing capacity of composite steel truss bridge girders after vehicle fire, a 100 m simple supported composite steel truss bridge girder was selected as the research object, and a typical oil tanker fire was taken as the fire scenario. This study identifies the most critical conditions associated with an oil tanker fire and outlines the degradation pattern of the residual load-bearing capacity of composite steel truss bridge girders after a vehicle fire. It also proposes a damage classification standard and an evaluation method for the load-bearing capacity based on the structural failure path and load-displacement curve. The results indicate that the most critical scenario during a vehicle fire occurs when the fire is located on the bridge deck, particularly in the middle section of the longitudinal bridge and the outermost lane of the transverse bridge. During a vehicle fire, the top chord is the component most affected by the thermal history. Under immersion cooling conditions, the remaining load-bearing capacity of the girder decreases more significantly compared with natural cooling. After the fire, the upper chord first reaches the yield strength, causing load transfer to adjacent horizontal inclined members. The stress of the horizontal inclined rod will develop rapidly, leading to structural instability and eventual failure. Four grades of load-bearing capacity damage for composite steel truss bridge girders after vehicle fire are defined to serve as references for practical engineering applications.
Open AccessStudy on Residual Load-Bearing Capacity of Composite Steel Truss Bridge Girders After Vehicle Fire
To investigate the residual load-bearing capacity of composite steel truss bridge girders after vehicle fire, a 100 m simple supported composite steel truss bridge girder was selected as the research object, and a typical oil tanker fire was taken as the fire scenario. This study identifies the most critical conditions associated with an oil tanker fire and outlines the degradation pattern of the residual load-bearing capacity of composite steel truss bridge girders after a vehicle fire. It also proposes a damage classification standard and an evaluation method for the load-bearing capacity based on the structural failure path and load-displacement curve. The results indicate that the most critical scenario during a vehicle fire occurs when the fire is located on the bridge deck, particularly in the middle section of the longitudinal bridge and the outermost lane of the transverse bridge. During a vehicle fire, the top chord is the component most affected by the thermal history. Under immersion cooling conditions, the remaining load-bearing capacity of the girder decreases more significantly compared with natural cooling. After the fire, the upper chord first reaches the yield strength, causing load transfer to adjacent horizontal inclined members. The stress of the horizontal inclined rod will develop rapidly, leading to structural instability and eventual failure. Four grades of load-bearing capacity damage for composite steel truss bridge girders after vehicle fire are defined to serve as references for practical engineering applications.
- 17 June 2025
- Published by Springer Nature
- p. 1479-1488
A Numerical Method for Evaluating Thermal Response of Hot-Cast Anchorage
- 17 June 2025
- Published by Springer Nature
- p. 1479-1488
A Numerical Method for Evaluating Thermal Response of Hot-Cast Anchorage
- 20 May 2025
- Published by Elsevier in Engineering Structures
- Vol. 338
Experimental investigation and numerical analysis on fire response of parallel-wire cable exposed to open-air fire
- 20 May 2025
- Published by Elsevier in Engineering Structures
- Vol. 338
Experimental investigation and numerical analysis on fire response of parallel-wire cable exposed to open-air fire
- 21 April 2025
- Published by Elsevier in Engineering Structures
- Vol. 335
An approach for predicting fire response of steel truss-concrete composite bridge girders subjected to semi-open fires
- 21 April 2025
- Published by Elsevier in Engineering Structures
- Vol. 335
An approach for predicting fire response of steel truss-concrete composite bridge girders subjected to semi-open fires
- Open Access
Mitigating Temperature Effects in Curved Continuous Steel Box Girders: A Parametric Thermodynamic Analysis and Design Recommendations
Curved continuous steel box girders are extensively utilized in bridge construction due to their efficiency and environmental benefits. However, in regions with significant temperature fluctuations, temperature effects can result in cumulative deformation and stress concentration, which may severely impact structural safety and durability. This study examines the structural response of curved continuous steel box girders with five spans under diverse temperature conditions and also develops a comprehensive parameterized thermodynamic numerical model. The model assesses the influence of cross-sectional shape parameters, including the number of cross-sectional box chambers, diaphragm thickness, and height-to-width ratio, as well as longitudinal structural parameters such as planar configurations, width-to-span ratio, and support arrangements, along with the arrangement of stiffening ribs on the temperature-induced effects in the girders. The results indicate that optimizing the width and eccentricity of support stiffeners to 30% and 25%, respectively, in support plate size can significantly alleviate local temperature-induced stresses. Additionally, variations in longitudinal and transverse stiffeners manifest minimal impact on thermal performance. These findings provide a theoretical foundation for improved design and construction practices, offering practical design recommendations to mitigate temperature effects and enhance the longevity and safety of such structures.
Open AccessMitigating Temperature Effects in Curved Continuous Steel Box Girders: A Parametric Thermodynamic Analysis and Design Recommendations
Curved continuous steel box girders are extensively utilized in bridge construction due to their efficiency and environmental benefits. However, in regions with significant temperature fluctuations, temperature effects can result in cumulative deformation and stress concentration, which may severely impact structural safety and durability. This study examines the structural response of curved continuous steel box girders with five spans under diverse temperature conditions and also develops a comprehensive parameterized thermodynamic numerical model. The model assesses the influence of cross-sectional shape parameters, including the number of cross-sectional box chambers, diaphragm thickness, and height-to-width ratio, as well as longitudinal structural parameters such as planar configurations, width-to-span ratio, and support arrangements, along with the arrangement of stiffening ribs on the temperature-induced effects in the girders. The results indicate that optimizing the width and eccentricity of support stiffeners to 30% and 25%, respectively, in support plate size can significantly alleviate local temperature-induced stresses. Additionally, variations in longitudinal and transverse stiffeners manifest minimal impact on thermal performance. These findings provide a theoretical foundation for improved design and construction practices, offering practical design recommendations to mitigate temperature effects and enhance the longevity and safety of such structures.
- Open Access
- 25 November 2024
- Published by Springer Nature in Advances in Bridge Engineering
- Vol. 5 (1) , 1-27
Fire behavior of composite steel truss bridge girders: numerical investigation and design strategies
Fire pose more severe threat to steel truss bridge girders as compared to common steel plate and box bridge girders. To deeply clarify failure mechanism of fire exposed steel truss bridge girders, this paper presents an investigation on fire performance of composite steel truss bridge girders simultaneously subjected to structural loadings and hydrocarbon fires. A numerical model, developed using the computer program ANSYS, is validated dependent on fire test to trace fire behavior of a typical through-type composite steel truss bridge girders under different hydrocarbon fire exposure conditions. The analysis is applied to evaluate influence of potential fire exposure scenarios occurred in bridge structures, including fire exposure lanes on bridge deck and fire exposure length beneath bridge, on temperature and structural response in steel truss bridge girders. The results shows that fire exposure lanes on bridge decks and fire exposure length beneath bridge has a significant influence on fire performance of steel truss bridge girders. Fire exposure on all lanes and side lanes can cut down fire resistance highly as compared to fire exposure on mid-lanes. The composite steel truss bridge girders exhibit special multi-hinge failure modes when fire exposure under bridge. Further, the composite steel truss bridge girders exposed to side-lane fire exhibit significant transverse torsional deformation. The established failure criteria dependent on structural deflection limit states, chord deformation and strength can be applied to evaluate fire resistance of actual composite steel truss bridge girders under realistic fire exposure scenarios. Limiting the minimum clearance of passage on bridge deck and increasing fire protection measures in upper portion of trusses can effectively improve fire resistance of through-type composite steel truss bridge girders. Some predominant design strategies closely related to oil tanker trucks traversing composite steel truss bridge girders are proposed to minimize probability of fire incidents on bridge and keep integrity of structure in the case of fire to the maximum extent possible.
- 25 November 2024
- Published by Springer Nature in Advances in Bridge Engineering
- Vol. 5 (1) , 1-27
Open AccessFire behavior of composite steel truss bridge girders: numerical investigation and design strategies
Fire pose more severe threat to steel truss bridge girders as compared to common steel plate and box bridge girders. To deeply clarify failure mechanism of fire exposed steel truss bridge girders, this paper presents an investigation on fire performance of composite steel truss bridge girders simultaneously subjected to structural loadings and hydrocarbon fires. A numerical model, developed using the computer program ANSYS, is validated dependent on fire test to trace fire behavior of a typical through-type composite steel truss bridge girders under different hydrocarbon fire exposure conditions. The analysis is applied to evaluate influence of potential fire exposure scenarios occurred in bridge structures, including fire exposure lanes on bridge deck and fire exposure length beneath bridge, on temperature and structural response in steel truss bridge girders. The results shows that fire exposure lanes on bridge decks and fire exposure length beneath bridge has a significant influence on fire performance of steel truss bridge girders. Fire exposure on all lanes and side lanes can cut down fire resistance highly as compared to fire exposure on mid-lanes. The composite steel truss bridge girders exhibit special multi-hinge failure modes when fire exposure under bridge. Further, the composite steel truss bridge girders exposed to side-lane fire exhibit significant transverse torsional deformation. The established failure criteria dependent on structural deflection limit states, chord deformation and strength can be applied to evaluate fire resistance of actual composite steel truss bridge girders under realistic fire exposure scenarios. Limiting the minimum clearance of passage on bridge deck and increasing fire protection measures in upper portion of trusses can effectively improve fire resistance of through-type composite steel truss bridge girders. Some predominant design strategies closely related to oil tanker trucks traversing composite steel truss bridge girders are proposed to minimize probability of fire incidents on bridge and keep integrity of structure in the case of fire to the maximum extent possible.