Vinicius Do Lago Pimentel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vinicius Do Lago Pimentel has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
A. Basharina-Freshville
University College London, London, WC1E 6BT
5 shared publications- Andrea Zani
Istituto Nazionale di Fisica Nucleare Sezione di Milano, 20133 Milano
5 shared publications - Andrew Blake
Lancaster University, Lancaster LA1 4YW, United Kingdom
5 shared publications - Andrew Mastbaum
Rutgers University, Piscataway, NJ, 08854, U.S.A.
5 shared publications D. Mladenov
CERN, The European Organization for Nuclear Research, 1211 Meyrin
5 shared publications- Dominic Brailsford
Lancaster University
5 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Open AccessCharge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- Open Access
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Measurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessMeasurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 14 November 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (7)
Differential balanced transimpedance amplifier for low-capacitance measurements in real-time monitoring of metal nanoparticle deposition.
Impedance measurements are crucial in various fields such as sensor transduction, process monitoring, and control systems, yet measuring low values of capacitance (~1 pF) in electrically noisy environments remains a challenge, particularly at an affordable cost. This paper presents a differential transimpedance amplifier (TIA)-based electronic circuit , which incorporates three blocks: two TIAs and a differential circuit with fine-tuning for null adjustment. The differential configuration improves common-mode noise rejection, allowing the system to operate reliably even in high-interference environments, which represents its main novelty. Detailed characterization of the circuit is provided, including its frequency-dependent response and baseline noise analysis. The circuit is suitable for frequencies below 20 kHz for samples with capacitance below 1 nF, though this capability varies depending on the capacitance being measured. The primary application demonstrated in this study is the real-time monitoring of silver nanoparticle deposition using a gas aggregation source. Capacitance measurements effectively tracked the deposition progress, even in electrically noisy environments, confirming the circuit’s ability to suppress external disturbances while maintaining picofarad-level sensitivity. Results show that the system can accurately monitor capacitance changes from the very initial stages of nanoparticle deposition, making it a valuable tool for in-situ real-time monitoring. The findings highlight the setup's precision and its potential for applications requiring detailed capacitance measurements. This work presents a robust and reliable method for nanoparticle deposition monitoring, emphasizing its differential noise-rejection performance and low-cost implementation, which is essential for advancing research and development in nanotechnology and materials science. Future improvements aim to enhance integration with other characterization techniques.
- 14 November 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (7)
Differential balanced transimpedance amplifier for low-capacitance measurements in real-time monitoring of metal nanoparticle deposition.
Impedance measurements are crucial in various fields such as sensor transduction, process monitoring, and control systems, yet measuring low values of capacitance (~1 pF) in electrically noisy environments remains a challenge, particularly at an affordable cost. This paper presents a differential transimpedance amplifier (TIA)-based electronic circuit , which incorporates three blocks: two TIAs and a differential circuit with fine-tuning for null adjustment. The differential configuration improves common-mode noise rejection, allowing the system to operate reliably even in high-interference environments, which represents its main novelty. Detailed characterization of the circuit is provided, including its frequency-dependent response and baseline noise analysis. The circuit is suitable for frequencies below 20 kHz for samples with capacitance below 1 nF, though this capability varies depending on the capacitance being measured. The primary application demonstrated in this study is the real-time monitoring of silver nanoparticle deposition using a gas aggregation source. Capacitance measurements effectively tracked the deposition progress, even in electrically noisy environments, confirming the circuit’s ability to suppress external disturbances while maintaining picofarad-level sensitivity. Results show that the system can accurately monitor capacitance changes from the very initial stages of nanoparticle deposition, making it a valuable tool for in-situ real-time monitoring. The findings highlight the setup's precision and its potential for applications requiring detailed capacitance measurements. This work presents a robust and reliable method for nanoparticle deposition monitoring, emphasizing its differential noise-rejection performance and low-cost implementation, which is essential for advancing research and development in nanotechnology and materials science. Future improvements aim to enhance integration with other characterization techniques.
- Open Access
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Supernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Open AccessSupernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- Open Access
- 14 November 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (9)
First measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024
- 14 November 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (9)
Open AccessFirst measurement of the total inelastic cross section of positively charged kaons on argon at energies between 5.0 and 7.5 GeV
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV / c beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380 ± 26 mbarns for the 6 GeV / c setting and 379 ± 35 mbarns for the 7 GeV / c setting. Published by the American Physical Society 2024
- 1 June 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (06) , P06033
Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)
- 1 June 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (06) , P06033
Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)
- 1 May 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (05) , C05048
Study and characterization of WLS for ARAPUCA to DUNE experiment
The photon detection system of the far detector of the Deep Underground Neutrino Experiment (DUNE) will collect liquid argon scintillation photons with an array of modules whose working principle is based on the ARAPUCA technology. These devices acting as light traps are able to convert VUV scintillation photons into visible ones and capture them inside a reflective cavity observed by an array of SiPMs as active photo-sensitive elements. The use of wavelength shifting techniques in light collecting systems for particle detection in liquid argon is of fundamental importance, since the scintillation photon wavelength is around 127 nm of the photon produced which is extremely challenging to be directly detected. The main objective of the present work was to explore and characterize different substrates, wavelength shifting compounds and deposition methods to optimize and improve the light collection of the ARAPUCA device.
- 1 May 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (05) , C05048
Study and characterization of WLS for ARAPUCA to DUNE experiment
The photon detection system of the far detector of the Deep Underground Neutrino Experiment (DUNE) will collect liquid argon scintillation photons with an array of modules whose working principle is based on the ARAPUCA technology. These devices acting as light traps are able to convert VUV scintillation photons into visible ones and capture them inside a reflective cavity observed by an array of SiPMs as active photo-sensitive elements. The use of wavelength shifting techniques in light collecting systems for particle detection in liquid argon is of fundamental importance, since the scintillation photon wavelength is around 127 nm of the photon produced which is extremely challenging to be directly detected. The main objective of the present work was to explore and characterize different substrates, wavelength shifting compounds and deposition methods to optimize and improve the light collection of the ARAPUCA device.
- 1 May 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (05) , C05045
First liquid argon test of the X-ARAPUCA
The X-ARAPUCA is a device for the detection of scintillation light in liquid argon and represents an evolution of the ARAPUCA design, with an increased collection efficiency and a simpler design. The first liquid argon test of an X-ARAPUCA prototype has been performed in the cryogenic facility of the Laboratáorio de Léptons da UNCIAMP and showed a detection efficiency of 3.5%± 0.5%, in line with the expectations from Monte Carlo simulations and extrapolations from measurements with standard ARAPUCAs.
- 1 May 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (05) , C05045
First liquid argon test of the X-ARAPUCA
The X-ARAPUCA is a device for the detection of scintillation light in liquid argon and represents an evolution of the ARAPUCA design, with an increased collection efficiency and a simpler design. The first liquid argon test of an X-ARAPUCA prototype has been performed in the cryogenic facility of the Laboratáorio de Léptons da UNCIAMP and showed a detection efficiency of 3.5%± 0.5%, in line with the expectations from Monte Carlo simulations and extrapolations from measurements with standard ARAPUCAs.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Blade Coating System for Organic Electronics
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Blade Coating System for Organic Electronics
- 15 August 2018
- Published by Springer Nature
- p. 239-247
Biopotential Amplification System Developed for Surface Electromyography Using Dry Electrodes
- 15 August 2018
- Published by Springer Nature
- p. 239-247
Biopotential Amplification System Developed for Surface Electromyography Using Dry Electrodes