Iñaki Tejero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Iñaki Tejero has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Javier Temprano
Department of Water and Environmental Sciences and Techniques, Cantabria University, 39005 Santander, Spain
8 shared publications - Rubén Díez-Montero
Universidad de Cantabria, Spain
6 shared publications - Ana Lorena Esteban‐García
Department of Sciences and Techniques of Water and the Environment University of Cantabria E‐39005 Santander Spain
4 shared publications - Carlos Alfonso Zafra-Mejía
Facultad del Medio Ambiente y Recursos Naturales, Universidad Distrital Francisco José de Caldas, Bogotá 110321, Colombia
4 shared publications - Amaya Lobo
Grupo de Ingeniería Ambiental, Departamento de Ciencias y Técnicas del Agua y del Medio Ambiente, Universidad de Cantabria, Avda. de Los Castros, 39005 Santander, Spain
3 shared publications - Carlos Rico
Department of Water and Environmental Science and Technologies, University of Cantabria, Avda. Los Castros, s/n, 39005 Santander, Spain
3 shared publications
Latest Publications
- Open Access
- 11 April 2022
- Published by Taylor & Francis in Environmental Technology
- Vol. 44 (22) , 3415-3436
Theoretical analysis of urban runoff pollutographs: identification of characterization variables and impact
This research presents a novel methodology to determine runoff water retention volumes that allow the design of storage tanks for storm sewer overflows. It is based on the use of the Stormwater Management Model (SWMM) to generate hydrographs and runoff pollutographs of a fictional urban basin. Three pollutants (TS, BOD5 and TN) are simulated for a given set of rains and the values taken by a proposed set of characterization variables for the pollutographs obtained are analyzed. Correlation and determination coefficients that exist between the different variables are analyzed while also performing a multivariate characterization using PCA and cluster analysis. In the case study presented, using IDF curves of the studied city, a probability of occurrence (Tr) is assigned to the values taken by the proposed characterization variables. To assess the impact and identify the most unfavorable pollutographs within the set of selected rains, impact evaluation variables (IEV’s) are established, based on the proposed characterization variables and by simulating the discharge to a receiving water body (river with initial concentration and constant flow). Finally, a storm sewer overflow is simulated, deriving a maximum flow for purification, and dimensioning retention tanks for different fractions of the total volume of runoff to control the maximum values of a specific IEV impact evaluation variable. Taking a design return period Trssd ≥ 10 years, the results obtained in the study case were 146.50 m3/ha imp for a 100% retention of the total runoff volume and 117.20 m3/ha imp for an 80% retention. GRAPHICAL ABSTRACT
- 11 April 2022
- Published by Taylor & Francis in Environmental Technology
- Vol. 44 (22) , 3415-3436
Open AccessTheoretical analysis of urban runoff pollutographs: identification of characterization variables and impact
This research presents a novel methodology to determine runoff water retention volumes that allow the design of storage tanks for storm sewer overflows. It is based on the use of the Stormwater Management Model (SWMM) to generate hydrographs and runoff pollutographs of a fictional urban basin. Three pollutants (TS, BOD5 and TN) are simulated for a given set of rains and the values taken by a proposed set of characterization variables for the pollutographs obtained are analyzed. Correlation and determination coefficients that exist between the different variables are analyzed while also performing a multivariate characterization using PCA and cluster analysis. In the case study presented, using IDF curves of the studied city, a probability of occurrence (Tr) is assigned to the values taken by the proposed characterization variables. To assess the impact and identify the most unfavorable pollutographs within the set of selected rains, impact evaluation variables (IEV’s) are established, based on the proposed characterization variables and by simulating the discharge to a receiving water body (river with initial concentration and constant flow). Finally, a storm sewer overflow is simulated, deriving a maximum flow for purification, and dimensioning retention tanks for different fractions of the total volume of runoff to control the maximum values of a specific IEV impact evaluation variable. Taking a design return period Trssd ≥ 10 years, the results obtained in the study case were 146.50 m3/ha imp for a 100% retention of the total runoff volume and 117.20 m3/ha imp for an 80% retention. GRAPHICAL ABSTRACT
- Open Access
- 1 September 2021
- Published by Elsevier in Journal of Environmental Management
- Vol. 294, 112940
Unplanted wetland-type filter for co-treatment of landfill leachate and septic tank wastewater: Analysing gravel replacement by plastic and passive (filling-emptied) aeration effects at pilot scale
- 1 September 2021
- Published by Elsevier in Journal of Environmental Management
- Vol. 294, 112940
Open AccessUnplanted wetland-type filter for co-treatment of landfill leachate and septic tank wastewater: Analysing gravel replacement by plastic and passive (filling-emptied) aeration effects at pilot scale
- 1 September 2019
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Municipal Engineer
- Vol. 172 (3) , 175-184
Sustainable urban drainage systems: a tool to adapt combined sewer systems to climate change
Climate change is a big challenge that may affect water and sanitation services. The authors studied a strategy to adapt current infrastructure to adverse effects due to climate change, such as more frequent and heavier rainfall, through sustainable urban drainage systems (SUDS). A part of the sewer network of Santander, in Spain, is taken as a case study. After building the model under the SWMM-5 code, some scenarios were simulated, including short-duration storm analysis, under the current climate and with climate change estimation, for an extended period simulation. The same analysis was performed adding SUDS. Peak flow, energy consumption reductions and the total storm water volume disconnected were measured. Every action had a positive effect in adapting the existing infrastructure to climate change, but the authors observed that when SUDS worked together, the benefits were greater, as expected. Any future intervention might be focused on encouraging SUDS as a drainage solution, not as isolated pilot projects.
- 1 September 2019
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Municipal Engineer
- Vol. 172 (3) , 175-184
Sustainable urban drainage systems: a tool to adapt combined sewer systems to climate change
Climate change is a big challenge that may affect water and sanitation services. The authors studied a strategy to adapt current infrastructure to adverse effects due to climate change, such as more frequent and heavier rainfall, through sustainable urban drainage systems (SUDS). A part of the sewer network of Santander, in Spain, is taken as a case study. After building the model under the SWMM-5 code, some scenarios were simulated, including short-duration storm analysis, under the current climate and with climate change estimation, for an extended period simulation. The same analysis was performed adding SUDS. Peak flow, energy consumption reductions and the total storm water volume disconnected were measured. Every action had a positive effect in adapting the existing infrastructure to climate change, but the authors observed that when SUDS worked together, the benefits were greater, as expected. Any future intervention might be focused on encouraging SUDS as a drainage solution, not as isolated pilot projects.
- 1 April 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 661, 187-195
Model-based evaluation of a trickling filter facility upgrade to biological nutrient removal
- 1 April 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 661, 187-195
Model-based evaluation of a trickling filter facility upgrade to biological nutrient removal
- 1 April 2019
- Published by Elsevier in Water Research
- Vol. 152, 1-11
Mass transfer enhancement and improved nitrification in MABR through specific membrane configuration
- 1 April 2019
- Published by Elsevier in Water Research
- Vol. 152, 1-11
Mass transfer enhancement and improved nitrification in MABR through specific membrane configuration
- 1 January 2018
- Published by Elsevier in Algal Research
- Vol. 29, 304-318
Model-based feasibility assessment of a deep solar photobioreactor for microalgae culturing
- 1 January 2018
- Published by Elsevier in Algal Research
- Vol. 29, 304-318
Model-based feasibility assessment of a deep solar photobioreactor for microalgae culturing
- 20 September 2016
- Published by Taylor & Francis in Urban Water Journal
- Vol. 14 (6) , 639-649
The physical factors affecting heavy metals accumulated in the sediment deposited on road surfaces in dry weather: a review
The main objective of this review is to identify and analyse physical factors (PF) involved in the heavy metal accumulation phenomenon in the road-deposited sediment (RDS) in dry weather. Electronic databases were used to establish an order of prevalence by establishing quartiles (Q-citation frequency) for the PF identified. The results show that the eleven PF can most likely be classified into three categories: climatic-anthropogenic-morphometric. The studies most frequently referenced land use (Q1), rainfall (Q2), particle size (Q2) and vehicles (Q3) as key PF. There is a similar behaviour between the concentrations of Zn-Pb-Cu associated with the RDS in dry weather and the dissolved fraction washed from the surface in road runoff. The size fraction <250 μm is representative of RDS to characterize the metals. The review expands knowledge about the influences of the PF in the processes of deposition-suspension-interception-removal of the metals load in road environments.
- 20 September 2016
- Published by Taylor & Francis in Urban Water Journal
- Vol. 14 (6) , 639-649
The physical factors affecting heavy metals accumulated in the sediment deposited on road surfaces in dry weather: a review
The main objective of this review is to identify and analyse physical factors (PF) involved in the heavy metal accumulation phenomenon in the road-deposited sediment (RDS) in dry weather. Electronic databases were used to establish an order of prevalence by establishing quartiles (Q-citation frequency) for the PF identified. The results show that the eleven PF can most likely be classified into three categories: climatic-anthropogenic-morphometric. The studies most frequently referenced land use (Q1), rainfall (Q2), particle size (Q2) and vehicles (Q3) as key PF. There is a similar behaviour between the concentrations of Zn-Pb-Cu associated with the RDS in dry weather and the dissolved fraction washed from the surface in road runoff. The size fraction <250 μm is representative of RDS to characterize the metals. The review expands knowledge about the influences of the PF in the processes of deposition-suspension-interception-removal of the metals load in road environments.
- 1 June 2016
- Published by Elsevier in Bioresource Technology
- Vol. 209, 195-204
Performance evaluation of a novel anaerobic–anoxic sludge blanket reactor for biological nutrient removal treating municipal wastewater
- 1 June 2016
- Published by Elsevier in Bioresource Technology
- Vol. 209, 195-204
Performance evaluation of a novel anaerobic–anoxic sludge blanket reactor for biological nutrient removal treating municipal wastewater
- 4 February 2016
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 91 (12) , 2950-2958
Denitrification coupled with methane oxidation in a membrane bioreactor after methanogenic pre‐treatment of wastewater
BACKGROUND: The presence of dissolved methane is an important environmental problem related to greenhouse gas emissions from wastewater treated in methanogenic bioreactors. Methane has a global warming potential of 28. For low‐strength wastewaters, such as sewage, dissolved methane could account for up to 50% of the total methane produced. Dissolved methane is easily desorbed from effluents when released into the environment or post‐treated in aerobic bioreactors. The use of dissolved methane as a carbon source for biological denitrification has been proposed as an alternative for reducing both greenhouse gas emissions and nitrogen concentrations in treated wastewater.RESULTS: The effluent of a methanogenic reactor operating at ambient temperature was post‐treated in a two‐compartment biological membrane bioreactor (MBR). The first compartment consisted of an anoxic denitrification reactor in which dissolved methane was oxidized. The second compartment was an aerobic membrane filtration reactor. Up to 60% nitrogen removal and 95% methane consumption were observed. Batch experiments indicated the presence of microorganisms that were capable of denitrification using dissolved methane.CONCLUSIONS: Denitrification using dissolved methane as a carbon source was feasible in an anoxic–aerobic MBR system. Denitrification resulted from a mixture of aerobic and anaerobic methane oxidizing bacteria, anammox and heterotrophic bacteria activity. © 2016 Society of Chemical Industry
- 4 February 2016
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 91 (12) , 2950-2958
Denitrification coupled with methane oxidation in a membrane bioreactor after methanogenic pre‐treatment of wastewater
BACKGROUND: The presence of dissolved methane is an important environmental problem related to greenhouse gas emissions from wastewater treated in methanogenic bioreactors. Methane has a global warming potential of 28. For low‐strength wastewaters, such as sewage, dissolved methane could account for up to 50% of the total methane produced. Dissolved methane is easily desorbed from effluents when released into the environment or post‐treated in aerobic bioreactors. The use of dissolved methane as a carbon source for biological denitrification has been proposed as an alternative for reducing both greenhouse gas emissions and nitrogen concentrations in treated wastewater.RESULTS: The effluent of a methanogenic reactor operating at ambient temperature was post‐treated in a two‐compartment biological membrane bioreactor (MBR). The first compartment consisted of an anoxic denitrification reactor in which dissolved methane was oxidized. The second compartment was an aerobic membrane filtration reactor. Up to 60% nitrogen removal and 95% methane consumption were observed. Batch experiments indicated the presence of microorganisms that were capable of denitrification using dissolved methane.CONCLUSIONS: Denitrification using dissolved methane as a carbon source was feasible in an anoxic–aerobic MBR system. Denitrification resulted from a mixture of aerobic and anaerobic methane oxidizing bacteria, anammox and heterotrophic bacteria activity. © 2016 Society of Chemical Industry
- 3 January 2015
- Published by Taylor & Francis in Urban Water Journal
- Vol. 13 (3) , 321-330
Cost-effectiveness analysis of sewer mining versus centralized wastewater treatment: Case study of the Arga river basin, Spain
In the context of the EU Water Framework Directive, a Cost-Effectiveness Analysis (CEA) was performed to compare centralized and decentralized wastewater treatment strategies aimed to improve the ecological status of a Spanish river. The implementation of several hybrid membrane bioreactors within the urban framework for sewer mining (SM) was compared with the more common wastewater treatment plant enlargement option. The assessment ranked 6 alternatives based on 12 potential scenarios, aimed at narrowing the uncertainty of the CEA. The cost analysis illustrated that SM is the most expensive option regarding both investment and operation and maintenance costs. However, the effectiveness of the alternatives evaluated depends significantly on the scenarios considered, being SM the most effective in most cases. Finally, the cost-effectiveness ratio showed SM as the best cost-effective alternative. CEA provides an ecological-economic indicator useful to prioritize wastewater treatment alternatives to achieve a given objective
- 3 January 2015
- Published by Taylor & Francis in Urban Water Journal
- Vol. 13 (3) , 321-330
Cost-effectiveness analysis of sewer mining versus centralized wastewater treatment: Case study of the Arga river basin, Spain
In the context of the EU Water Framework Directive, a Cost-Effectiveness Analysis (CEA) was performed to compare centralized and decentralized wastewater treatment strategies aimed to improve the ecological status of a Spanish river. The implementation of several hybrid membrane bioreactors within the urban framework for sewer mining (SM) was compared with the more common wastewater treatment plant enlargement option. The assessment ranked 6 alternatives based on 12 potential scenarios, aimed at narrowing the uncertainty of the CEA. The cost analysis illustrated that SM is the most expensive option regarding both investment and operation and maintenance costs. However, the effectiveness of the alternatives evaluated depends significantly on the scenarios considered, being SM the most effective in most cases. Finally, the cost-effectiveness ratio showed SM as the best cost-effective alternative. CEA provides an ecological-economic indicator useful to prioritize wastewater treatment alternatives to achieve a given objective