TMTomasz Mróz

Tomasz Mróz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomasz Mróz has a total of 315 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pulse shape discrimination for event rejection in BEGe-type high-purity germanium detectors

    by A. Biondi, K. Szczepaniec, T. Mróz, M. Misiaszek, G. Zuzel

    High-purity germanium detectors are widely used in rare-event searches due to their excellent energy resolution and extremely high intrinsic (radio)purity. In experiments searching for neutrinoless double beta decay in $$^{76}$$ 76 Ge such as Legend , pulse shape discrimination is required to suppress multi-site $$\gamma $$ γ events. In this work, we investigate whether pulse shape discrimination classifiers trained exclusively on $$\gamma $$ γ ray data can be used to identify and reject $$\alpha $$ α events, without the need for dedicated $$\alpha $$ α training. In detectors such as Legend , the total number of registered $$\alpha $$ α events over the experiment lifetime is expected to be insufficient to train dedicated classifiers, while still contributing to the background. Two approaches based on machine learning are studied: a multilayer perceptron and a projective likelihood classifier. The p+ surface of a point-contact semi-planar germanium detector was exposed to $$^{209}$$ 209 Po and $$^{210}$$ 210 Po sources deposited on a thin gold foil. Two measurement campaigns were performed, yielding $$1.36\times 10^{5}$$ 1.36 × 10 5 and $$1.87\times 10^{6}$$ 1.87 × 10 6 $$\alpha $$ α events, respectively. Both classification methods achieve efficient separation of single-site and multi-site $$\gamma $$ γ events while strongly reducing the $$\alpha $$ α component. The multilayer perceptron provides the best overall performance, with a signal-like event survival greater than 80%, a background-like event survival below 20%, and an $$\alpha $$ α -rejection factor exceeding $$2.71\times 10^{4}$$ 2.71 × 10 4 . These results demonstrate that robust pulse shape discrimination for high-purity germanium detectors can be achieved using training information derived solely from $$\gamma $$ γ events, providing a promising strategy for next-generation neutrinoless double beta decay searches.

  • Environmental γ -ray flux in Hall C at LNGS and its correlation with radon activity

    by L. Luzzi, R. Santorelli, G. Zuzel, P. Agnes, D. Cano-Ott, C. Ghiano, M. Laubenstein, T. Mroz, V. Pesudo Fortes, J. Plaza del Olmo, et al.

    We report a comprehensive measurement of the environmental $\ensuremath{\gamma}$-ray flux in Hall C of the Gran Sasso National Laboratory. A spatial mapping of the radiation was carried out using a high-purity germanium detector mounted on a movable cart and deployed at eight locations within the hall. The detector response function and full-energy-peak efficiencies were determined through Geant4 simulations validated with calibrated $\ensuremath{\gamma}$-ray sources, with particular attention devoted to the efficiency modeling and associated systematic uncertainties. In the energy range of 57--2800 keV, the average $\ensuremath{\gamma}$-ray flux is measured to be ($0.46\ifmmode\pm\else\textpm\fi{}0.0{6}_{\mathrm{stat}}\ifmmode\pm\else\textpm\fi{}0.0{3}_{\mathrm{syst}}$) ${\mathrm{cm}}^{\ensuremath{-}2}\text{ }{\mathrm{s}}^{\ensuremath{-}1}$. The radon level was monitored for about a month using a radon detector mounted on the same cart, and a clear correlation is observed between the environmental $\ensuremath{\gamma}$-ray rate and the ambient radon concentration, consistent with the short-lived daughters of $^{222}\mathrm{Rn}$. This result represents the first high-precision and efficiency-corrected mapping of the $\ensuremath{\gamma}$-ray flux in Hall C, substantially improving its radiological characterization and providing key input for future rare-event experiments operating in this hall.

  • Study of proton-induced reactions on natural zinc targets

    by Arshiya Anees Ahmed, Tomasz M. Mróz, Jerzy W. Mietelski

  • Top Cited Papers
    Open Access

    First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment

    by H Acharya, N Ackermann, M Agostini, A Alexander, C Andreoiu, G R Araujo, F T Avignone, M Babicz, W Bae, A M Bakalyarov, et al.

    The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.


  • Open Access

    99mTc activity concentrations in room air and resulting internal contamination of medical personnel during ventilation–perfusion lung scans

    by K. Brudecki, E. Borkowska, K. Gorzkiewicz, M. Kostkiewicz, T. Mróz

    This paper presents the results of measurements of 99mTc activity concentrations in indoor air in a nuclear medicine department and resulting estimated 99mTc intake by medical personnel. 99mTc air activity measurements were conducted at the Nuclear Medicine Department, John Paul II Hospital, Krakow, Poland, during ventilation–perfusion SPECT lung scans. Technetium from the air was collected by means of a mobile aerosol sampler with a Petryanov filter operating at an average flow rate of 10 dm3 min−1. Measured activities ranged from 99 ± 11 to 6.1 ± 0.5 kBq m−3. The resulting daily average intake of 99mTc by medical staff was estimated to be 5.4 kBq, 4.4 kBq, 3.0 kBq and 2.5 kBq, respectively, for male technicians, female technicians, male nurses and female nurses. Corresponding annual effective doses were 1.6 µSv for technicians and 1 µSv for nurses. The highest equivalent dose values were determined for extrathoracic (ET) airways: 5 µSv and 10 µSv for nurses and technicians, respectively. It is concluded that estimated annual absorbed doses are over three orders of magnitude lower than the dose limit established in the Polish Atomic Law Act and in recommendations of the International Commission on Radiological Protection for medical staff.


  • Open Access

    Medical activated charcoal tablets as a cheap tool for passive monitoring of gaseous 131I activity in air of nuclear medicine departments

    by Tomasz Mróz, Kamil Brudecki, Jerzy W. Mietelski, Mirosław Bartyzel, Ryszard Misiak, Andrzej Kornas

    It is well known that monitoring of radioactivity released from nuclear medicine departments is necessary to ensure the radiological safety of patients and personnel. Unfortunately, equipment for air sampling is often expensive, loud and is not suitable to use in hospitals. Our goal was to find cheap and simple system for passive monitoring of 131I activity concentration in the air of nuclear medicine departments. Medical activated charcoal tablets were used, because charcoal is excellent material for 131I trapping and tablets are readily available. Our proposed sampling protocol contains tablets preparation, exposure and measurements using HPGe detector. Different methods of tablets preparation (drying, impregnation with KI or NaOH) were tested while an experimental chamber was prepared for estimating 131I (released from Na131I, similar to that used in therapy) trapping efficiency of tablets in different conditions. Finally, tablets were placed in plastic holders and tested in nuclear medicine facilities.


  • The Influence of Biochar Enriched with Magnesium and Sulfur on the Amount of Perennial Ryegrass Biomass and Selected Chemical Properties and Biological of Sandy Soil

    by Krzysztof Gondek, Monika Mierzwa-Hersztek, Michał Kopeć, Tomasz Mróz

    Biochar used in this study was prepared from wheat straw and enriched with 10% solutions of chemically pure salts: ammonium sulfate [(NH4)2SO4] and magnesium sulfate (MgSO4 7H2O). The aim of this study was to determine the growth response of Perennial ryegrass L. as well as identify changes in chemical and biological properties of sandy soil after the application of biochar. A significant increase in the amount of Perennial ryegrass L. biomass was determined after amending the soil with unenriched biochar and biochar enriched with (NH4)2SO4. The highest immobilization of available forms of Mg was observed for biochar enriched with (NH4)2SO4. The highest dehydrogenase activity was determined in the soil with biochar enriched with MgSO4 7H2O.


  • Open Access

    Measurement of 131I activity in air indoor Polish nuclear medical hospital as a tool for an internal dose assessment

    by K. Brudecki, A. Szczodry, T. Mróz, A. Kowalska, J. W. Mietelski

    This paper presents results of 131I air activity measurements performed within nuclear medical hospitals as a tool for internal dose assessment. The study was conducted at a place of preparation and administration of 131I (“hot room”) and at a nurse station. 131I activity measurements were performed for 5 and 4 consecutive working days, at the “hot room” and nurse station, respectively. Iodine from the air was collected by a mobile HVS-30 aerosol sampler combined with a gas sampler. Both the gaseous and aerosol fractions were measurement. The activities in the gaseous fraction ranged from (28 ± 1 Bq m−3) to (492 ± 4) Bq m−3. At both sampling sites, the activity of the gaseous iodine fraction trapped on activated charcoal was significantly higher than that of the aerosol fraction captured on Petrianov filter cloth. Based on these results, an attempt has been made to estimate annual inhalation effective doses, which were found to range from 0.47 mSv (nurse female) to 1.3 mSv (technician male). The highest annual inhalation equivalent doses have been found for thyroid as 32, 27, 13, and 11 mSv, respectively, for technician male, technical female, nurse male, and nurse female. The method presented here allows to fill the gaps in internal doses measurements. Moreover, because method has been successful used for many years in radioactive contamination monitoring of air in cases of serious nuclear accidents, it should also be used in nuclear medicine.


  • 131I INTERNAL CONTAMINATION AND COMMITTED DOSE ASSESSMENT AMONG NUCLEAR MEDICINE MEDICAL PERSONNEL

    by K Brudecki, A Kluczewska-Gałka, T Mróz, B Jarząb, P Zagrodzki, P Janowski

    This study presents 131I thyroid activity measurements of 56 employees of the Department of Nuclear Medicine and Endocrine Oncology, Centre for Oncology in Gliwice. The research instrument was a whole-body spectrometer. In 44 out of 56 examined staff members, the determined 131I activity was found to be above the detection limit. The measured activities ranged from 6 ± 2 to 457 ± 118 Bq. The maximum estimated committed effective dose reached was 1.5 mSv/y. The results were compared with previous measurements conducted in another Polish nuclear medical unit. From this comparison, we can see that radiological safety among nuclear medicine personnel can be improved by appropriate work organisation. Reducing exposure of workers can be achieved by properly organised turnovers concerning the most vulnerable worksites. In addition, to lower the radiation risk, it is essential to comply strictly with the isolation regime for the patients.


  • Open Access

    Determination of element composition and extraterrestrial material occurrence in moss and lichen samples from King George Island (Antarctica) using reactor neutron activation analysis and SEM microscopy

    by Tomasz Mróz, Katarzyna Szufa, Marina V. Frontasyeva, Vladimir Tselmovich, Tatiana Ostrovnaya, Andrzej Kornaś, Maria A. Olech, Jerzy W. Mietelski, Kamil Brudecki

    Seven lichens (Usnea antarctica and U. aurantiacoatra) and nine moss samples (Sanionia uncinata) collected in King George Island were analyzed using instrumental neutron activation analysis, and concentration of major and trace elements was calculated. For some elements, the concentrations observed in moss samples were higher than corresponding values reported from other sites in the Antarctica, but in the lichens, these were in the same range of concentrations. Scanning electron microscopy (SEM) and statistical analysis showed large influence of volcanic-origin particles. Also, the interplanetary cosmic particles (ICP) were observed in investigated samples, as mosses and lichens are good collectors of ICP and micrometeorites.