Norlela Ishak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Norlela Ishak has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Ramli Adnan
College of Engineering, Universiti Teknologi MARA, Malaysia
42 shared publicationsMazidah Tajjudin
Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam, 40450, Selangor
31 shared publications- Mohd Hezri Fazalul Rahiman
Faculty of Electrical Engineering, Universiti Teknologi Mara, Shah Alam, Selangor, Malaysia
24 shared publications Hashimah Ismail
Faculty of Engineering, Universiti Selangor (UNISEL), Selangor, Malaysia
19 shared publicationsNorhashim Mohd Arshad
Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam, Malaysia
7 shared publicationsMohd Hezri Fazalul Rahiman
Faculty of Electrical Engineering, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
5 shared publications
Latest Publications
- Open Access
- 28 August 2021
- Published by Penerbit UTM Press in ELEKTRIKA- Journal of Electrical Engineering
- Vol. 20 (2) , 8-13
Tracking Control of an Electro-Hydraulic Actuator System using LQR Controller
Electro-Hydraulic actuator (EHA) is a one type of application used in industry and building high performance of motion control process. Apparently, dealing with EHA behaviour is quite difficult and make the controlling process complicated. Designing Linear Quadratic Regulator (LQR) controller as a feedback controller require in selecting the weighting parameter Q and R. The result shows that the higher value of Q offers fast response and high stability by referring the placement of close-loop poles. However, the higher value of Q gives a higher error that can make position performance of hydraulic actuator become worst. In order to overcome this problem, the feedforward controller is developed by implementing the zero-phase error tracking control (ZPETC). It shows that both feedforward and feedback controller offers good tracking position performance in reducing gain and phase error.
- 28 August 2021
- Published by Penerbit UTM Press in ELEKTRIKA- Journal of Electrical Engineering
- Vol. 20 (2) , 8-13
Open AccessTracking Control of an Electro-Hydraulic Actuator System using LQR Controller
Electro-Hydraulic actuator (EHA) is a one type of application used in industry and building high performance of motion control process. Apparently, dealing with EHA behaviour is quite difficult and make the controlling process complicated. Designing Linear Quadratic Regulator (LQR) controller as a feedback controller require in selecting the weighting parameter Q and R. The result shows that the higher value of Q offers fast response and high stability by referring the placement of close-loop poles. However, the higher value of Q gives a higher error that can make position performance of hydraulic actuator become worst. In order to overcome this problem, the feedforward controller is developed by implementing the zero-phase error tracking control (ZPETC). It shows that both feedforward and feedback controller offers good tracking position performance in reducing gain and phase error.
- Open Access
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
I2CACIS 2020 Organizing Committee
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Open AccessI2CACIS 2020 Organizing Committee
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 57-61
Studies on Robustness of Trajectory Adaptive ZPETC with Application to Electro-Hydraulic Actuator
Mostly modern mechanical systems have becoming an expanding field in industrial applications which require the support of precision motion control strategies. This paper is on the studies of robustness of trajectory adaptive ZPETC to discrete-time plant model that having a non-minimum phase zero very near to unity circle. This model was obtained from open-loop experiment of Electro-Hydraulic actuator using 50 ms sampling-time. This would contribute significant challenges in designing suitable feedforward controller since this model is very difficult to control. This is due to the non-minimum phase zero of this kind is producing slow decaying transient response. The ZPETC controller that does not require the factorization of zeros polynomial was used in the studies. Simulation results of the studies had shown better tracking and controls as compare to the conventional ZPETC. The simulation works were also validated via real-time control of hydraulic actuator.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 57-61
Studies on Robustness of Trajectory Adaptive ZPETC with Application to Electro-Hydraulic Actuator
Mostly modern mechanical systems have becoming an expanding field in industrial applications which require the support of precision motion control strategies. This paper is on the studies of robustness of trajectory adaptive ZPETC to discrete-time plant model that having a non-minimum phase zero very near to unity circle. This model was obtained from open-loop experiment of Electro-Hydraulic actuator using 50 ms sampling-time. This would contribute significant challenges in designing suitable feedforward controller since this model is very difficult to control. This is due to the non-minimum phase zero of this kind is producing slow decaying transient response. The ZPETC controller that does not require the factorization of zeros polynomial was used in the studies. Simulation results of the studies had shown better tracking and controls as compare to the conventional ZPETC. The simulation works were also validated via real-time control of hydraulic actuator.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 133-136
A Study on IMC-based PID for Steam Distillation Process
PID controller had been widely accepted in industrial applications since decades. The PID algorithm even though is simple but yet, can produce satisfactory results. However, the efficiency of the PID controller is derived from a proper tuning of its parameters. There are no generic rules that can fulfill all the system design requirements. Due to that, PID tuning techniques are progressively being developed and refined by researchers in order to enhance the performance of PID control loop. Recently, an internal model control (IMC) tuning method had been introduced and been studied by many researchers. This paper adopts a version of IMC rules and simulated the response on a steam distillation for essential oil extraction process which is an FOPDT type model. The performance was compared to rule-based tuning methods, namely Ziegler-Nichols and AMIGO. The implementation of IMC tuning rules which are less sensitive to the accuracy of process parameters had attained better results compared to Ziegler Nichols and AMIGO based PID.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 133-136
A Study on IMC-based PID for Steam Distillation Process
PID controller had been widely accepted in industrial applications since decades. The PID algorithm even though is simple but yet, can produce satisfactory results. However, the efficiency of the PID controller is derived from a proper tuning of its parameters. There are no generic rules that can fulfill all the system design requirements. Due to that, PID tuning techniques are progressively being developed and refined by researchers in order to enhance the performance of PID control loop. Recently, an internal model control (IMC) tuning method had been introduced and been studied by many researchers. This paper adopts a version of IMC rules and simulated the response on a steam distillation for essential oil extraction process which is an FOPDT type model. The performance was compared to rule-based tuning methods, namely Ziegler-Nichols and AMIGO. The implementation of IMC tuning rules which are less sensitive to the accuracy of process parameters had attained better results compared to Ziegler Nichols and AMIGO based PID.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 100-104
Fuzzy PID tracking performance for ball and beam system
This paper presents a design of Fuzzy PID controller to control the position of ball and beam system. The design objective is to improve the transient performance and to evaluate the controller ability to track a sine and square wave input signal. Fuzzy controller is proposed to overcome the problem of PID controller especially in obtaining optimal parameters. The effectiveness of the proposed controller was verified by simulation and compared with a PID controller obtained using PID auto-tune function in Simulink Toolbox. The results from step response and input tracking show that the proposed controller had a better performance in both evaluations compared to PID.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 100-104
Fuzzy PID tracking performance for ball and beam system
This paper presents a design of Fuzzy PID controller to control the position of ball and beam system. The design objective is to improve the transient performance and to evaluate the controller ability to track a sine and square wave input signal. Fuzzy controller is proposed to overcome the problem of PID controller especially in obtaining optimal parameters. The effectiveness of the proposed controller was verified by simulation and compared with a PID controller obtained using PID auto-tune function in Simulink Toolbox. The results from step response and input tracking show that the proposed controller had a better performance in both evaluations compared to PID.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 301-304
Load effect studies on ARX model parameters of vertical position Electro-Hydraulic Actuator
EHA system is commonly found in industrial processes such as aircraft manufacturing, food production and automotive assembly due to accurate positioning toward the load and fast response. There are some behavior limitations in modeling this system due to uncertainties, highly nonlinearities, and leakage effect. This paper studies the effect of loads on ARX model parameters of vertical position EHA system. Open-loop experimental tests on EHA system without load and with load were conducted. Load experimental weights of 1kg, 2.25kg and 3.5kg and sampling-time of 30ms were used. ARX model structure was used and derived from Matlab System Identification Toolbox. Results showed that no significant effect to ARX331 model parameters due to varying load applied.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 301-304
Load effect studies on ARX model parameters of vertical position Electro-Hydraulic Actuator
EHA system is commonly found in industrial processes such as aircraft manufacturing, food production and automotive assembly due to accurate positioning toward the load and fast response. There are some behavior limitations in modeling this system due to uncertainties, highly nonlinearities, and leakage effect. This paper studies the effect of loads on ARX model parameters of vertical position EHA system. Open-loop experimental tests on EHA system without load and with load were conducted. Load experimental weights of 1kg, 2.25kg and 3.5kg and sampling-time of 30ms were used. ARX model structure was used and derived from Matlab System Identification Toolbox. Results showed that no significant effect to ARX331 model parameters due to varying load applied.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 334-339
Comparison of varied order for fractional-order model
Fractional-order model is a generalization of integration and differentiation of non-integer number. Due to its flexibility, it explains a dynamic system better than integer-order model does. In this study, fractional-order model is applied in model identification of electro-hydraulic actuator system and the performance is compared with integer-order model. First-order until third-order model of both models were evaluated using output-error method. The models were validated based on their best-fit and independence test. The findings show fractional-order model can give a better estimation with less parameter.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 334-339
Comparison of varied order for fractional-order model
Fractional-order model is a generalization of integration and differentiation of non-integer number. Due to its flexibility, it explains a dynamic system better than integer-order model does. In this study, fractional-order model is applied in model identification of electro-hydraulic actuator system and the performance is compared with integer-order model. First-order until third-order model of both models were evaluated using output-error method. The models were validated based on their best-fit and independence test. The findings show fractional-order model can give a better estimation with less parameter.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 253-257
Design of fuzzy fractional-order PI+ PD controller
This paper presents the design of a fuzzy fractional-order Proportional Integral plus Proportional Derivative controller in a two stage control structures where fractional-order terms were considered. Due to some weaknesses discovered in both PID and fuzzy controllers, this design was proposed. Basically, fuzzy system was implemented to tune the fractional-order of PI while fractional-order PD was fixed. The proposed controller was compared against conventional PID controller, fuzzy PID and fuzzy PI+PD controller. All results were presented from simulation studies applied to a steam temperature process which inherit slow dynamics and non-linear properties. Based on the results, the significance of fractional-order controller was evidently shown where the proposed controller had improved the response in terms of speed and control output efficiency.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 253-257
Design of fuzzy fractional-order PI+ PD controller
This paper presents the design of a fuzzy fractional-order Proportional Integral plus Proportional Derivative controller in a two stage control structures where fractional-order terms were considered. Due to some weaknesses discovered in both PID and fuzzy controllers, this design was proposed. Basically, fuzzy system was implemented to tune the fractional-order of PI while fractional-order PD was fixed. The proposed controller was compared against conventional PID controller, fuzzy PID and fuzzy PI+PD controller. All results were presented from simulation studies applied to a steam temperature process which inherit slow dynamics and non-linear properties. Based on the results, the significance of fractional-order controller was evidently shown where the proposed controller had improved the response in terms of speed and control output efficiency.
- Open Access
- 1 January 2016
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 9 (1) , 32-48
Identification Of Electro-Hydraulic Actuator Using Fractional Model
Electro-hydraulic actuator (EHA system) identification is to describe the characteristic of the system that useful for prediction or control system design. There are numerous methods of EHA modeling but there has not been much model using fractional-order (FO) model. In this work, integer-order (IO) model and FO model are developed to model EHA system. Output-error method is used as the estimator for both model. The coefficient of IO model was first estimated and using the estimated coefficient, the derivative order of FO model is estimated. These models has been validated by comparison of error, coefficient of determination (R2), mean square error (MSE) and correlation function. The results for the proposed model show improvement compared to the IO model.
- 1 January 2016
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 9 (1) , 32-48
Open AccessIdentification Of Electro-Hydraulic Actuator Using Fractional Model
Electro-hydraulic actuator (EHA system) identification is to describe the characteristic of the system that useful for prediction or control system design. There are numerous methods of EHA modeling but there has not been much model using fractional-order (FO) model. In this work, integer-order (IO) model and FO model are developed to model EHA system. Output-error method is used as the estimator for both model. The coefficient of IO model was first estimated and using the estimated coefficient, the derivative order of FO model is estimated. These models has been validated by comparison of error, coefficient of determination (R2), mean square error (MSE) and correlation function. The results for the proposed model show improvement compared to the IO model.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 157-161
Identification of electro-hydraulic actuator system using commensurate fractional-order
System identification using fractional-order model gives more suitable explanation of the dynamic system properties that classical integer-order model could provide. The derivative order of fractional-order model is more flexible because it has more degree-of-freedom. In FO modeling, output error method is commonly used is because the process behavior or the system to be modeled is assumed as non-stochastic. In this study, a fractional-order model with variation of commensurate order was considered. The result showed that fractional-order model with commensurate order gives better accuracy.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 157-161
Identification of electro-hydraulic actuator system using commensurate fractional-order
System identification using fractional-order model gives more suitable explanation of the dynamic system properties that classical integer-order model could provide. The derivative order of fractional-order model is more flexible because it has more degree-of-freedom. In FO modeling, output error method is commonly used is because the process behavior or the system to be modeled is assumed as non-stochastic. In this study, a fractional-order model with variation of commensurate order was considered. The result showed that fractional-order model with commensurate order gives better accuracy.