Toshihiro Takeshita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Toshihiro Takeshita has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Takeshi Kobayashi
National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan
10 shared publications Takeshi Kobayashi
Sensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, JAPAN
6 shared publicationsYusuke Takei
Sensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, JAPAN
5 shared publicationsNatsumi Makimoto
Natl Inst Adv Ind Sci & Technol, 1-2-1 Namiki, Tsukuba, Ibaraki 3050028, Japan
4 shared publications- Takahiro Yamashita
National Institute of Advanced Industrial Science and Technology
4 shared publications - Yusuke Takei
National Institute of Advanced Industrial Science and Technology (AIST), Research Institute for Hybrid Functional Integration (HyFI), Tsukuba, Japan
4 shared publications
Latest Publications
- Open Access
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (1) , 20-25
Lever Mechanism for Diaphragm-Type Vibrators to Enhance Vibrotactile Intensity
Thin and light vibrators that leverage the inverse piezoelectric effect with a diaphragm mechanism are promising vibrotactile actuators owing to their form factors and high temporal and frequency response. However, generating perceptually sufficient displacement in the low-frequency domain is challenging. This study presents a lever mechanism mounted on a diaphragm vibrator to enhance the vibrotactile intensity of low-frequency vibrotactile stimuli. The lever mechanism is inspired by the tactile contact lens consisting of an array of cylinders held against the skin on a sheet that enhances micro-bump tactile detection. We built an experimental apparatus including our previously developed thin-film diaphragm-type vibrator, which reproduced the common characteristic of piezoelectric vibrators: near-threshold displacement (10 to 20 μm) at low frequency. Experiments demonstrated enhanced vibrotactile intensity at frequencies less than 100 Hz with the lever mechanism. Although the arrangement and material of the mechanism can be improved, our findings can help improve the expressiveness of diaphragm-type vibrators.
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (1) , 20-25
Open AccessLever Mechanism for Diaphragm-Type Vibrators to Enhance Vibrotactile Intensity
Thin and light vibrators that leverage the inverse piezoelectric effect with a diaphragm mechanism are promising vibrotactile actuators owing to their form factors and high temporal and frequency response. However, generating perceptually sufficient displacement in the low-frequency domain is challenging. This study presents a lever mechanism mounted on a diaphragm vibrator to enhance the vibrotactile intensity of low-frequency vibrotactile stimuli. The lever mechanism is inspired by the tactile contact lens consisting of an array of cylinders held against the skin on a sheet that enhances micro-bump tactile detection. We built an experimental apparatus including our previously developed thin-film diaphragm-type vibrator, which reproduced the common characteristic of piezoelectric vibrators: near-threshold displacement (10 to 20 μm) at low frequency. Experiments demonstrated enhanced vibrotactile intensity at frequencies less than 100 Hz with the lever mechanism. Although the arrangement and material of the mechanism can be improved, our findings can help improve the expressiveness of diaphragm-type vibrators.
- 5 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (1) , 8-13
Representing Fine Texture of Pencil Hardness by High-Frequency Vibrotactile Equivalence Conversion Using Ultra-Thin PZT-MEMS Vibrators
This study aims to represent fine texture differences in pencil hardness using intensity segment modulation (ISM), a sensory equivalent conversion method of vibration from high to low frequencies. This method enables the presentation of delicate tactile sensations even with small transducers. We integrated this approach in the world's thinnest ultra-thin PZT-MEMS vibrator with a stylus-type device. The vibration waveforms of four types of pencil hardness were captured under the same conditions, and the differences in the frequency components were confirmed. We compared the fine texture feelings under raw signal, ISM, and ISM below 1 kHz conditions by conducting discrimination tests and subjective similarity evaluations. The results showed that ISM could reproduce similar feelings of the pencil hardness.
- 5 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 17 (1) , 8-13
Representing Fine Texture of Pencil Hardness by High-Frequency Vibrotactile Equivalence Conversion Using Ultra-Thin PZT-MEMS Vibrators
This study aims to represent fine texture differences in pencil hardness using intensity segment modulation (ISM), a sensory equivalent conversion method of vibration from high to low frequencies. This method enables the presentation of delicate tactile sensations even with small transducers. We integrated this approach in the world's thinnest ultra-thin PZT-MEMS vibrator with a stylus-type device. The vibration waveforms of four types of pencil hardness were captured under the same conditions, and the differences in the frequency components were confirmed. We compared the fine texture feelings under raw signal, ISM, and ISM below 1 kHz conditions by conducting discrimination tests and subjective similarity evaluations. The results showed that ISM could reproduce similar feelings of the pencil hardness.
- Open Access
- 11 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Development of wearable multi-lead ECG measurement device using cubic flocked electrode
This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable the measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient’s skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.
- 11 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Open AccessDevelopment of wearable multi-lead ECG measurement device using cubic flocked electrode
This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable the measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient’s skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.
- 18 August 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SN) , SN1024
Development of a nail-deformation haptics device fabricated adopting ultra-thin PZT-MEMS technology
We describe the fabrication and evaluation of a nail-deformation haptics actuator having a flexible haptics film. The novelty of the developed actuator is the generation of a vibration that directly deforms the nail and finger pad. The flexible piezo-MEMS film is fabricated adopting ultra-thin lead-zirconate-titanate microelectromechanical system (MEMS) and lamination technology. The flexible piezo-MEMS film has flexibility (thickness: 65 μ m) and low weight (mass: 55 mg). The device can thus be attached on a nail without discomfort. A nail-deformation haptics actuator was fabricated by attaching this flexible piezo-MEMS film on an artificial nail. When applying a DC voltage of 40 V to the film, there was a strain of −36.5 × 10 −6 in the cylindrical direction of the nail and −12.1 × 10 −6 in the circumferential direction. Furthermore, applying an AC voltage (40 V pp , 20 V offset ) at a frequency of 200–300 Hz, the finger pad deformed sufficiently to perceive vibration.
- 18 August 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SN) , SN1024
Development of a nail-deformation haptics device fabricated adopting ultra-thin PZT-MEMS technology
We describe the fabrication and evaluation of a nail-deformation haptics actuator having a flexible haptics film. The novelty of the developed actuator is the generation of a vibration that directly deforms the nail and finger pad. The flexible piezo-MEMS film is fabricated adopting ultra-thin lead-zirconate-titanate microelectromechanical system (MEMS) and lamination technology. The flexible piezo-MEMS film has flexibility (thickness: 65 μ m) and low weight (mass: 55 mg). The device can thus be attached on a nail without discomfort. A nail-deformation haptics actuator was fabricated by attaching this flexible piezo-MEMS film on an artificial nail. When applying a DC voltage of 40 V to the film, there was a strain of −36.5 × 10 −6 in the cylindrical direction of the nail and −12.1 × 10 −6 in the circumferential direction. Furthermore, applying an AC voltage (40 V pp , 20 V offset ) at a frequency of 200–300 Hz, the finger pad deformed sufficiently to perceive vibration.
- 12 August 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (10) , 105001
Mechanical characteristics of laminated film vibrator using an ultra-thin MEMS actuator
This paper describes fabrication of a laminated film vibrator that uses an ultra-thin micro-electric mechanical system (MEMS) and the effect of lamination on the actuator. The thickness of the ultra-thin MEMS actuator fabricated by ultra-thin MEMS technology was 7.26 µ m, making it especially flexible. The vibrator was actuated by applying voltage on a lead zirconate titanate (PZT) thin film. Then, we applied a lamination method to package the actuator. However, the lamination structure influenced the mechanical characteristics of the vibrator. Therefore, we evaluated the effect of the lamination structure on the static and dynamic characteristics of the laminated film vibrator. Four types of laminated film vibrators with different layer structures were prepared, and their displacements and velocity were measured when DC and AC voltages were applied. The maximum displacement of the cantilevers constructed from the laminated film vibrator (PZT: 11 mm × 11 mm) was 113.3 µ m at 40 V DC. This result is in good agreement with the calculated result. Furthermore, the dynamic characteristics from both the experimental and simulated results confirmed that the resonant frequency of the laminated film vibrator depends on the film structure. This means the dynamic characteristics can be adjusted to suit the application. Applications of this laminated film actuator include use as a flexible hybrid electronics haptic device for monitoring vital signs.
- 12 August 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (10) , 105001
Mechanical characteristics of laminated film vibrator using an ultra-thin MEMS actuator
This paper describes fabrication of a laminated film vibrator that uses an ultra-thin micro-electric mechanical system (MEMS) and the effect of lamination on the actuator. The thickness of the ultra-thin MEMS actuator fabricated by ultra-thin MEMS technology was 7.26 µ m, making it especially flexible. The vibrator was actuated by applying voltage on a lead zirconate titanate (PZT) thin film. Then, we applied a lamination method to package the actuator. However, the lamination structure influenced the mechanical characteristics of the vibrator. Therefore, we evaluated the effect of the lamination structure on the static and dynamic characteristics of the laminated film vibrator. Four types of laminated film vibrators with different layer structures were prepared, and their displacements and velocity were measured when DC and AC voltages were applied. The maximum displacement of the cantilevers constructed from the laminated film vibrator (PZT: 11 mm × 11 mm) was 113.3 µ m at 40 V DC. This result is in good agreement with the calculated result. Furthermore, the dynamic characteristics from both the experimental and simulated results confirmed that the resonant frequency of the laminated film vibrator depends on the film structure. This means the dynamic characteristics can be adjusted to suit the application. Applications of this laminated film actuator include use as a flexible hybrid electronics haptic device for monitoring vital signs.
- Open Access
- 18 July 2022
- Published by Springer Nature in Research Square
Development of Wearable Multi-Lead ECG Measurement Device using Cubic Flocked Electrode
This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient’s skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.
- 18 July 2022
- Published by Springer Nature in Research Square
Open AccessDevelopment of Wearable Multi-Lead ECG Measurement Device using Cubic Flocked Electrode
This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient’s skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 592-595
Flexible Parametric Speaker with Ultra-Thin PZT/Si MEMS Chips Integrated On Paper Substrate
In this paper, we report on the integration of an ultra-thin PZT/Si chip on a paper substrate, which functions as a simple speaker by applying a voltage in the audible frequency range. The PZT/Si chip used is very thin, only 5 µm thick, so it does not interfere with the flexibility of the substrate, and the electrode connection process does not use a high temperature process, allowing integration on paper. This technology is expected to be applied to electronic paper, electronic components for smartphone surrounds, and flexible parametric speakers.
- 9 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 592-595
Flexible Parametric Speaker with Ultra-Thin PZT/Si MEMS Chips Integrated On Paper Substrate
In this paper, we report on the integration of an ultra-thin PZT/Si chip on a paper substrate, which functions as a simple speaker by applying a voltage in the audible frequency range. The PZT/Si chip used is very thin, only 5 µm thick, so it does not interfere with the flexibility of the substrate, and the electrode connection process does not use a high temperature process, allowing integration on paper. This technology is expected to be applied to electronic paper, electronic components for smartphone surrounds, and flexible parametric speakers.
- Open Access
Practical Evaluation of Printed Strain Sensors Based on Long-Term Static Strain Measurements
Recent progress in printable electronics has enabled the fabrication of printed strain sensors for diverse applications. These include the monitoring of civil infrastructure, the gradual aging of which raises concerns about its effective maintenance and safety. Therefore, there is a need for automated sensing systems that provide information on the performance and behavior of engineering structures that are subjected to dynamic and static loads. The application of printed strain sensors in structural health monitoring is of growing interest owing to its large-area and cost-effective fabrication process. Previous studies have proven the suitability of printable strain sensors for dynamic strain measurements on bridges; however, the analysis of the long-term stability of printed sensors during static strain measurements is still lacking. Thus, this study aims to assess the long-term stability of printed strain sensor arrays and their suitability for the static strain analysis of large civil structures. The developed sensors and a dedicated wireless data acquisition system were deployed inside a gravity dam, which was selected as the field test environment. This test environment was chosen owing to the relatively stable temperature inside the dam and the very slow static strain changes associated with periodic water level changes. The results exhibited an average signal drift of 20 over 127 days. One of the sensor arrays was installed on a small crack in the dam structure; it showed that the sensors can track static strain changes owing to variations in the crack opening, which are related to the water level changes in the dam. Overall, the results of the developed sensors exhibit good strain sensitivity and low signal drift. This indicates the potential suitability of printed sensors for applications in the static strain analysis of engineering structures.Open AccessPractical Evaluation of Printed Strain Sensors Based on Long-Term Static Strain Measurements
Recent progress in printable electronics has enabled the fabrication of printed strain sensors for diverse applications. These include the monitoring of civil infrastructure, the gradual aging of which raises concerns about its effective maintenance and safety. Therefore, there is a need for automated sensing systems that provide information on the performance and behavior of engineering structures that are subjected to dynamic and static loads. The application of printed strain sensors in structural health monitoring is of growing interest owing to its large-area and cost-effective fabrication process. Previous studies have proven the suitability of printable strain sensors for dynamic strain measurements on bridges; however, the analysis of the long-term stability of printed sensors during static strain measurements is still lacking. Thus, this study aims to assess the long-term stability of printed strain sensor arrays and their suitability for the static strain analysis of large civil structures. The developed sensors and a dedicated wireless data acquisition system were deployed inside a gravity dam, which was selected as the field test environment. This test environment was chosen owing to the relatively stable temperature inside the dam and the very slow static strain changes associated with periodic water level changes. The results exhibited an average signal drift of 20 over 127 days. One of the sensor arrays was installed on a small crack in the dam structure; it showed that the sensors can track static strain changes owing to variations in the crack opening, which are related to the water level changes in the dam. Overall, the results of the developed sensors exhibit good strain sensitivity and low signal drift. This indicates the potential suitability of printed sensors for applications in the static strain analysis of engineering structures. - Open Access
- 24 March 2021
- Published by MYU K.K. in Sensors and Materials
- Vol. 33 (3) , 1073-1080
Relationship between Thermal Stability and Structure of MEMS Cantilevers Embedded in an Elastomer
- 24 March 2021
- Published by MYU K.K. in Sensors and Materials
- Vol. 33 (3) , 1073-1080
Open AccessRelationship between Thermal Stability and Structure of MEMS Cantilevers Embedded in an Elastomer
- 2 March 2020
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 5 (2) , 025001
Flexible substrate with floating island structure for mounting ultra-thin silicon chips
A flexible substrate with a novel floating island structure design was developed for mounting ultra-thin silicon chips. The structure reduced the strain propagated from the stretching base to the ultra-thin silicon chips. While conventional structures reduce strain by 64.2%, the floating island structure reduced strain by 90.2%. Furthermore, tests for operational stability and durability were conducted using an ultra-thin operational amplifier (OPAMP) mounted on the flexible substrate with a floating island structure, where the OPAMP was thinned to 30 µm by chemical mechanical polishing. The ultra-thin OPAMP operated with no strain effects even when repeatedly stretched to 30% elongation. Also, the ultra-thin silicon chip mounted on the floating island structure demonstrated durability against >25000 stretching cycles. This research is applicable for functional wearable devices using ultra-thin silicon chips and featuring high flexibility and stretchability.
- 2 March 2020
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 5 (2) , 025001
Flexible substrate with floating island structure for mounting ultra-thin silicon chips
A flexible substrate with a novel floating island structure design was developed for mounting ultra-thin silicon chips. The structure reduced the strain propagated from the stretching base to the ultra-thin silicon chips. While conventional structures reduce strain by 64.2%, the floating island structure reduced strain by 90.2%. Furthermore, tests for operational stability and durability were conducted using an ultra-thin operational amplifier (OPAMP) mounted on the flexible substrate with a floating island structure, where the OPAMP was thinned to 30 µm by chemical mechanical polishing. The ultra-thin OPAMP operated with no strain effects even when repeatedly stretched to 30% elongation. Also, the ultra-thin silicon chip mounted on the floating island structure demonstrated durability against >25000 stretching cycles. This research is applicable for functional wearable devices using ultra-thin silicon chips and featuring high flexibility and stretchability.