JWJan-Willem A. Wasmann

Jan-Willem A. Wasmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jan-Willem A. Wasmann has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluating the Quality of Artificial Intelligence Chatbot Responses in Audiology Case Interpretation and Management: A Blinded Comparative Study

    by Nicole Labuschagne, Faheema Mahomed-Asmail, Vinaya Manchaiah, Jan-Willem Wasmann, De Wet Swanepoel

    Purpose: This study aimed to compare the quality of audiological case interpretation and management recommendations generated by two freely-accessible large language model (LLM) chatbots (ChatGPT 3.5 and Gemini 2.0 Flash) with those of qualified audiologists, using an expert-rated quality assessment tool. Method: This study followed a two-phased, cross-sectional design with comparative analysis: Phase 1: 15 anonymized adult audiological cases were interpreted by 10 qualified audiologists (> 2 years' experience) and two LLM chatbots, producing 60 interpretations; each interpretation answered two questions (diagnostic interpretation and management), giving 120 responses. Phase 2: 30 qualified audiologists independently rated all 120 responses using the CLEAR (Completeness, Lack of false information, Evidence, Appropriateness, Relevance) tool to assess the quality of AI-generated health information (five raters per response; 600 total ratings), blinded to responder identity. Results: There were no statistically significant differences in CLEAR scores between artificial intelligence–generated and audiologist-generated responses (all p > .22 in mixed-effects modeling). Absolute differences did not exceed 1.2 CLEAR points on a 5–25 scale, with 95% confidence intervals crossing zero, indicating no statistically detectable differences in expert-rated quality. Interrater reliability was poor for single audiologist raters (ICC = .17–.18) but moderate for aggregated scores (ICC = .50–.53). Internal consistency was excellent (Cronbach's alpha = .94–.95). Conclusions: Under controlled conditions, no statistically significant differences in CLEAR scores were detected between LLM-generated and audiologist-generated responses. These findings do not establish formal equivalence but represent a meaningful empirical benchmark for this emerging area of research.

  • Open Access

    From policy debate to empirical evidence: a proof-of-concept bibliometric and LLM-assisted abstract-level content analysis of OTC hearing aid research before and after FDA regulation

    by Changgeng Mo, Vinaya Manchaiah, Jan-Willem A. Wasmann, Shangqiguo Wang

    1. In August 2017, the U.S. Congress passed the Over-the-Counter (OTC) Hearing Aid Act as part of the FDA Reauthorization Act (Warren and Grassley 2017), following recommendations by the President’...


  • Open Access

    Remote cochlear implant programming in real-life listening environments: a feasibility and acceptability study

    by Charlotte V. R. Snoeck, Martina Brendel, Jan-Willem A. Wasmann

    Objectives: This study investigates the feasibility, acceptability, and perceived benefits of conducting cochlear implant (CI) remote fitting in real-life listening situations. Methods: Twelve post-lingually deafened CI users participated in four sessions: a baseline in-clinic visit, two remote fitting sessions (at home and in a real-life setting), and a final in-clinic evaluation. Participants completed a Client Oriented Scale of Improvement (COSI) and a custom post-study survey to assess usability, technical stability, satisfaction, and communication quality. Results: Half of the participants (six out of twelve) reported high satisfaction or satisfaction (four out of twelve) with remote fitting. Frequently cited benefits included reduced travel time and improved satisfaction in specific listening situations, while common drawbacks were technical issues and reduced non-verbal communication. Group-level speech intelligibility in quiet remained stable across sessions, which served as a safety check. All participants would recommend remote fitting to other CI users, and most considered it important for future CI care. Conclusion: This study provides insights into challenges and lessons learned of using remote fitting tools for practicing clinicians and designers of future remote programming tools. Remote fitting in real-world settings is feasible and well accepted by CI users with relatively good aided speech intelligibility. It can offer added value by enabling fitting and subjective assessment in listening situations that are according to the COSI, important to the CI user. Improving current remote fitting tools with better communication features and usability may broaden access, particularly for users with poorer speech recognition, and may increase adoption within hybrid care pathways.

  • Open Access

    Large Language Models Readability Classification: A Variability Analysis of Sources and Metrics

    by Hector Gabriel Corrale de Matos, Jan-Willem A. Wasmann, Thais Catalani Morata, Kátia de Freitas Alvarenga, Lilian Cássia Bórnia Jacob

    : Accurate health information is ineffective if patients cannot understand it. Large Language Model (LLM) health research values veridical precision; however, linguistic accessibility remains an under-examined component of output quality and usability. This study investigated two sources of variability in readability classification: differences across LLM systems and across readability metrics. The analysis tested 1,120 data points from seven systems in English and Portuguese, comparing baseline responses with a Wikipedia-grounded condition. Content was assessed using five standard readability metrics that measure distinct aspects of text complexity. Systems were statistically homogeneous at baseline but became significantly heterogeneous under Wikipedia grounding, indicating variability in the combination of Retrieval-Augmented Generation (differential readability effects of the same source-grounding instruction across systems). Significant metric variability was observed in all conditions, showing that readability metrics are not interchangeable. Although retrieval grounding is commonly used to improve accuracy, our findings show a trade-off: verified-source grounding can yield inconsistent readability. Therefore, evaluation protocols should use transparent, vendor-agnostic criteria, with metric-specific and language-aware thresholds, and be applied whenever models or grounding configurations change to support accessible cross-language health communication.

  • Top Cited Papers
    Open Access

    Data standards in audiology: a mixed-methods exploration of community perspectives and implementation considerations

    by Charlotte Vercammen, Antje Heinrich, Christophe Lesimple, Alessia Paglialonga, Jan-Willem A. Wasmann, Mareike Buhl

    This study addresses conceptual issues around data standardisation in audiology, and outlines steps towards achieving it. It reports a survey of the computational audiology community on their current understanding, needs, and preferences concerning data standards. Based on survey findings and a panel discussion, recommendations are made concerning moving forward with standardisation in audiology. Mixed-methods: (1) review of existing standardisation efforts; (2) a survey of the computational audiology community; (3) expert panel discussion in a dedicated session at the 2024 Virtual Conference of Computational Audiology. Survey: 82 members of the global community; Panel discussion: five experts. A prerequisite for any global audiology database are agreed data standards. Although many are familiar with the general idea, few know of existing initiatives, or have actively participated in them. Ninety percent of respondents expressed willingness to follow or contribute to standardisation efforts. The panel discussed relevant initiatives (e.g. OMOP, openEHR, Noah) and explored both challenges (around harmonisation) and opportunities (alignment with other medical fields and conversion among approaches). Combining conceptual discussion with stakeholder views, the study offers guidance for implementing interoperable data standards in audiology. It highlights community support, key issues to address, and suggests paths for future work.


  • Open Access

    Using AI on Wikipedia and Wikidata Editing for Health Education: Implementation and Evaluation

    by Hector Gabriel Corrale de Matos, Jan-Willem Wasmann, Lilian Cássia Bornia Jacob

    This session explores the integration of generative AI in health education within Wikimedia editing projects focused on hearing health information. The educational implications of AI in collaborative knowledge production remain an open question to exploration. We aim to present a teaching model and educational use of AI assistance to improve edits by students and engagement on Wikimedia projects. The framework proposed to analyze AI-assisted compared to traditional editorial approaches with machine-based and human evaluation on metrics, student perceptions, and content production. This session is relevant to the Edu Wiki conference because it directly addresses the intersection of AI and education in Wikimedia projects. It provides an opportunity to discuss how AI tools can transform student contributions while maintaining educational goals and community standards. The proposal includes a structured approach to training and editing using chatbots and metrics assessment using wiki-based tools such as LiftWing, ProVe, and Recoin, as well as student surveys and content analysis sheets. The focus on specialized health content provides insights into how AI can fill knowledge gaps in technical domains, making this session valuable for those interested in expanding Wikimedia's reach in specialized subject areas using AI.

  • Open Access

    Reaction time as a measure of spectrotemporal modulation sensitivity in Nucleus cochlear implant users

    by J. Ignacio Calderon De Palma, Enrico Migliorini, Andy J. Beynon, Bas van Dijk, Wendy Huinck, Cris Lanting, Emmanuel Mylanus, A. John van Opstal, Birgit Philips, Nikki Philpott, et al.

    Cochlear implant users can achieve high levels of speech recognition despite severe hearing loss. However, outcomes vary considerably, and some users continue to struggle. This study assessed Nucleus cochlear implant users’ sensitivity to spectrotemporal modulations, important acoustic features for speech recognition, using a reaction-time task with ripple sounds. Ripples contain similar spectrotemporal dynamics as speech, without resembling words, and allow precise control over spectral and temporal parameters. Cochlear implant users’ reaction times to ripple onsets varied systematically with modulation characteristics: temporal modulations around 16 Hz consistently yielded the shortest reaction times, while reaction times increased with increasing spectral density. These effects of modulation were nearly identical across participants, indicating a similar tuning to the tested spectrotemporal features. In contrast, the average reaction time, across all modulations, differed substantially between participants, ranging from 200 ms to about 1 second. These individual differences correlated modestly with phoneme recognition scores (r = 0.52), indicating that overall reaction times for the tested modulations relates to speech processing ability. These two findings (consistent modulation-dependent reaction times across participants, and their modest correlation with phoneme recognition) indicate that reaction times reflect underlying auditory sensitivity to spectrotemporal modulations. The substantial unexplained variance in phoneme recognition, however, suggests that modulation sensitivity alone is not sufficient to account for individual differences in speech understanding. This points to an additional role for non-acoustic, cognitive factors. Further, modeling results also suggest that individual differences in reaction times can be attributed to a combination of both sensory factors (i.e., modulation sensitivity) and non-auditory influences, such as decision-making processes.

  • Open Access

    Feasibility of a Cochlear Implant Fitting Approach Based on Phoneme Confusions: Lessons Learned from the AuDiET Study

    by Jan-Willem A. Wasmann, Enrico Migliorini, Nikki Philpott, Birgit Philips, Bas van Dijk, Wendy Huinck

    Background: Traditional speech recognition testing in Cochlear Implant (CI) care primarily captures aggregate speech recognition performance, often overlooking detailed phoneme identification errors. This feasibility study introduces a fitting approach focusing on individual CI users' phoneme difficulties identified through self-testing paradigms.Methods: Twenty-three postlingually deaf, experienced CI users underwent fitting adjustments based on Phoneme Recognition in Quiet test outcomes. A basic fitting check was followed by advanced fitting adjustments that ranged from generic (7 out of 23) to specific adjustments targeting specific phonemes (16 out of 23).Results: The new MAP was preferred by 74% (18 out of 23) of participants, yet the aggregate phoneme identification performance showed no significant change between the pre- and post-fitting visits. However, a positive trend in targeted phoneme identification was noted (t(22) = -2.3, p = .03), approaching but not reaching conventional significance after Bonferroni-Holm correction (adjusted p = .09). A significant improvement in targeted phoneme identification was observed in the subgroup that adhered to a targeted fitting (t(11) = -3.3, P = .006, adjusted p = .03, Cohen’s d = .88).Conclusion: Using phoneme identification evaluations in the CI fitting process in experienced adult CI users is feasible.

  • Remote Cochlear Implant Assessments: Validity and Stability in Self-Administered Smartphone-Based Testing

    by Jan-Willem A. Wasmann, Wendy J. Huinck, Cris P. Lanting

    Objectives: The stability of remote testing in cochlear implant care was studied by testing the influence of time-of-day, listener fatigue, and motivation on the outcomes of the aided threshold test (ATT) and digit triplets test (DTT) in cochlear implant (CI) recipients using self-tests at-home on a smartphone or tablet. Design: A single-center repeated measures cohort study design (n = 50 adult CI recipients). The ATT and DTT were tested at-home ten times, with nine of these sessions planned within a period of eight days. Outcomes were modeled as a function of time-of-day, momentary motivation, listeners’ task-related fatigue, and chronotype (i.e., someone’s preference for morning or evening due to the sleep-wake cycle) using linear mixed models. Additional factors included aided monosyllabic word recognition in quiet, daily-life fatigue, age, and CI experience. Results: Out of 500 planned measurements, 407 ATTs and 476 DTTs were completed. The ATT determined thresholds and impedances were stable across sessions. The factors in the DTT model explained 75% of the total variance. Forty-nine percent of the total variance was explained by individual differences in the participants’ DTT performance. For each 10% increase in word recognition in quiet, the DTT speech reception threshold improved by an average of 1.6 dB. DTT speech reception threshold improved, on average by 0.1 dB per repeated session and correlated with the number of successful DTTs per participant. There was no significant time-of-day effect on auditory performance in at-home administered tests. Conclusions: This study is one of the first to report on the validity and stability of remote assessments in CI recipients and reveals relevant factors. CI recipients can be self-tested at any waking hour to monitor performance via smartphone or tablet. Motivation, task-related fatigue, and chronotype did not affect the outcomes of ATT or DTT in the studied cohort. Word recognition in quiet is a good predictor for deciding whether the DTT should be included in an individual’s remote test battery. At-home testing is reliable for cochlear implant recipients and offers an opportunity to provide care in a virtual hearing clinic setting.


  • Open Access

    Remote Cochlear Implant Assessments: Validity and Stability in Self-Administered Smartphone-Based Testing

    by Jan-Willem A. Wasmann, Wendy Huinck, Cris Lanting

    Objectives. The stability of remote testing in cochlear implant care was studied by testing the influence of time-of-day, listener fatigue, and motivation on the outcomes of the aided threshold test (ATT) and digit triplets test (DTT) in CI recipients using self-tests at-home on a smartphone or tablet.Design. A single-center repeated measures cohort study design (n = 50 adult CI recipients). The ATT and DTT were tested at-home ten times, with nine of these sessions planned within a period of eight days. Outcomes were modeled as a function of time-of-day, momentary motivation, listeners’ task-related fatigue, and chronotype (i.e., someone’s preference for morning or evening due to the sleep-wake cycle) using linear mixed models. Additional factors included aided monosyllabic word recognition in quiet, daily-life fatigue, age, and CI experience. Results. Out of 500 planned measurements, 407 ATTs and 476 DTTs were completed. The ATT determined thresholds and impedances were stable across sessions. The factors in the DTT model explained 75% of the total variance. 49% of the total variance was explained by individual differences in the participants’ DTT performance. For each 10% increase in word recognition in quiet, the DTT Speech Reception Threshold (SRT) improved by an average of 1.6 dB. DTT SRT improved, on average by 0.1 dB per repeated session and correlated with the number of successful DTTs per participant. There was no significant time-of-day effect on auditory performance in at-home administered tests. Conclusions. This study is one of the first to report on the validity and stability of remote assessments in CI recipients and reveals relevant factors. CI recipients can be self-tested at any waking hour to monitor performance via smartphone or tablet. Motivation, task-related fatigue, and chronotype did not affect the outcomes of ATT or DTT in the studied cohort. Word recognition in quiet is a good predictor for deciding whether the DTT should be included in an individual’s remote test battery. At-home testing is reliable for cochlear implant recipients and offers an opportunity to provide care in a virtual hearing clinic setting.