FOFrancis Obiweluozor Onyekachi

Francis Obiweluozor Onyekachi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Francis Obiweluozor Onyekachi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Chan Hee Park

    Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea; Department of Mechanical Engineering Graduate School, Chonbuk National University, Jeonju city, Republic of Korea

    4 shared publications
  • In Seok Jeong

    Department of Thoracic and Cardiovascular Surgery, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea

    4 shared publications
  • Mukhammad Kayumov

    Extracorporeal Cardiopulmonary Innovation, Technology, and Education (EXCITE) Research Group, Chonnam National University Hospital, Gwangju 61469, Republic of Korea

    3 shared publications
  • Bikendra Maharjan

    2 shared publications
  • Cheol Sang Kim

    Department of Bionanosystem Engineering Graduate School, Chonbuk National University, Jeonju City, Republic of Korea

    2 shared publications
  • Cheol Sang Kim

    Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju, Republic of Korea

    2 shared publications

Latest Publications

  • Open Access

    Extracorporeal circulation models in small animals: beyond the limits of preclinical research

    by Mukhammad Kayumov, Reverien Habimana, Dowan Kim, Francis O Obiweluozor, In Seok Jeong, Hwa Jin Cho

    Extracorporeal membrane oxygenation (ECMO) use has remarkably increased in recent years. Although ECMO has become essential for patients with refractory cardiac and respiratory failure, extracorporeal circulation (ECC) is associated with significant complications. Small-animal models of ECC have been developed and widely used to better understand ECC-induced pathophysiology. This review article summarizes the development of small-animal ECC models, including the animal species, circuit configuration, priming, perioperative procedures, cannulation, and future perspectives of small-animal ECMO models.


  • Open Access

    A Comparative Study of an Anti-Thrombotic Small-Diameter Vascular Graft with Commercially Available e-PTFE Graft in a Porcine Carotid Model

    by Kyo Seon Lee, Mukhammad Kayumov, Gladys A. Emechebe, Do-Wan Kim, Hwa-Jin Cho, Yun-Jin Jeong, Dong-Weon Lee, Jun-Kyu Park, Chan-Hee Park, Cheol-Sang Kim, et al.

    Background: We have designed a reinforced drug-loaded vascular graft composed of polycaprolactone (PCL) and polydioxanone (PDO) via a combination of electrospinning/3D printing approaches. To evaluate its potential for clinical application, we compared the in vivo blood compatibility and performance of PCL/PDO + 10%DY grafts doped with an antithrombotic drug (dipyridamole) with a commercial expanded polytetrafluoroethylene (e-PTFE) graft in a porcine model. Methods: A total of 10 pigs (weight: 25–35 kg) were used in this study. We made a new 5-mm graft with PCL/PDO composite nanofiber via the electrospinning technique. We simultaneously implanted a commercially available e-PTFE graft (n = 5) and our PCL/PDO + 10%DY graft (n = 5) into the carotid arteries of the pigs. No anticoagulant/antiplatelet agent was administered during the follow-up period, and ultrasonography was performed weekly to confirm the patency of the two grafts in vivo. Four weeks later, we explanted and compared the performance of the two grafts by histological analysis and scanning electron microscopy (SEM). Results: No complications, such as sweating on the graft or significant bleeding from the needle hole site, were seen in the PCL/PDO + 10%DY graft immediately after implantation. Serial ultrasonographic examination and immunohistochemical analysis demonstrated that PCL/PDO + 10%DY grafts showed normal physiological blood flow and minimal lumen reduction, and pulsed synchronously with the native artery at 4 weeks after implantation. However, all e-PTFE grafts occluded within the study period. The luminal surface of the PCL/PDO + 10%DY graft in the transitional zone was fully covered with endothelial cells as observed by SEM. Conclusion: The PCL/PDO + 10%DY graft was well tolerated, and no adverse tissue reaction was observed in porcine carotid models during the short-term follow-up. Colonization of the graft by host endothelial and smooth muscle cells coupled with substantial extracellular matrix production marked the regenerative capability. Thus, this material may be an ideal substitute for vascular reconstruction and bypass surgeries. Long-term observations will be necessary to determine the anti-thrombotic and remodeling potential of this device.


  • Merging 3D printing with electrospun biodegradable small-caliber vascular grafts immobilized with VEGF

    by Gladys A Emechebe, Francis O Obiweluozor, In Seok Jeong, Jun-Kyu Park, Chan Hee Park, Cheol Sang Kim


  • Acute Immune Response in Venoarterial and Venovenous Extracorporeal Membrane Oxygenation Models of Rats

    by Hwa-Jin Cho, Mukhammad Kayumov, Dowan Kim, Kyoseon Lee, Francis Obiweluozor Onyekachi, Kyung-Woon Jeung, Yongsook Kim, Jacky Y. Suen, John F. Fraser, In-Seok Jeong

    Although experimental extracorporeal membrane oxygenation (ECMO) animal models have been reported, there are few studies on the immune response to ECMO. We developed the venoarterial (VA) and venovenous (VV) model in rats and serially investigated the changes in the distribution of immune cells. Forty rats underwent both VA and VV modes of ECMO, and blood samples were collected at 1 day before ECMO (D-1), at the end of ECMO run (D+0), and 3 days after the ECMO (D+3). Flow cytometry was used to characterize surface marker expression (CD3, CD4, CD8, CD43, CD45, CD45R, CD161, and His48) on immune cells. Granulocytes were initially activated in both ECMO types and were further reduced but not normalized until 3 days of decannulation. Monocyte and natural killer cells were decreased initially in VA mode. B lymphocytes, helper T lymphocytes, and cytotoxic T lymphocytes also significantly decreased in VA modes after ECMO, but this phenomenon was not prominent in the VV modes. Overall immune cells proportion changed after ECMO run in both modes, and the immunologic balance altered significantly in the VA than in VV mode. Our ECMO model is feasible for the hemodynamic and immunologic research, and further long-term evaluation is needed.


  • Considerations in the Development of Small-Diameter Vascular Graft as an Alternative for Bypass and Reconstructive Surgeries: A Review

    by Francis O. Obiweluozor, Gladys A. Emechebe, Do-Wan Kim, Hwa-Jin Cho, Chan Hee Park, Cheol Sang Kim, In Seok Jeong

    Background Current design strategies for small diameter vascular grafts (< 6 mm internal diameter; ID) are focused on mimicking native vascular tissue because the commercially available grafts still fail at small diameters, notably due to development of intimal hyperplasia and thrombosis. To overcome these challenges, various design approaches, material selection, and surface modification strategies have been employed to improve the patency of small-diameter grafts. Review The purpose of this review is to outline various considerations in the development of small-diameter vascular grafts, including material choice, surface modifications to enhance biocompatibility/endothelialization, and mechanical properties of the graft, that are currently being implanted. Additionally, we have taken into account the general vascular physiology, tissue engineering approaches, and collective achievements of the authors in this area. We reviewed both commercially available synthetic grafts (e-PTFE and PET), elastic polymers such as polyurethane and biodegradable and bioresorbable materials. We included naturally occurring materials by focusing on their potential application in the development of future vascular alternatives. Conclusion Until now, there are few comprehensive reviews regarding considerations in the design of small-diameter vascular grafts in the literature. Here-in, we have discussed in-depth the various strategies employed to generate engineered vascular graft due to their high demand for vascular surgeries. While some TEVG design strategies have shown greater potential in contrast to autologous or synthetic ePTFE conduits, many are still hindered by high production cost which prevents their widespread adoption. Nonetheless, as tissue engineers continue to develop on their strategies and procedures for improved TEVGs, soon, a reliable engineered graft will be available in the market. Hence, we anticipate a viable TEVG with resorbable property, fabricated via electrospinning approach to hold a greater potential that can overcome the challenges observed in both autologous and allogenic grafts. This is because they can be mechanically tuned, incorporated/surface-functionalized with bioactive molecules and mass-manufactured in a reproducible manner. It is also found that most of the success in engineered vascular graft approaching commercialization is for large vessels rather than small-diameter grafts used as cardiovascular bypass grafts. Consequently, the field of vascular engineering is still available for future innovators that can take up the challenge to create a functional arterial substitute.


  • Mussel-inspired elastic interpenetrated network hydrogel as an alternative for anti-thrombotic stent coating membrane

    by Francis O. Obiweluozor, Bikendra Maharjan, A. Gladys Emechebe, Chan Hee Park, Cheol Sang Kim


  • A mussel inspired self-expandable tubular hydrogel with shape memory under NIR for potential biomedical applications

    by Francis O. Obiweluozor, Amin GhavamiNejad, Bikendra Maharjan, Jinwoo Kim, Chan Hee Park, Cheol Sang Kim

    We engineered a novel shape memory polymer (SMP), a nanocomposite hydrogel containing polydopamine nanospheres (PDNs) as a self-expandable tubular hydrogel under near infrared (NIR) irradiation.