Rory Phillips
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rory Phillips has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Alba Centeno
Graphenea SA San Sebastian Spain
1 shared publication - Amaia Zurutuza
Graphenea San Sebastián Spain
1 shared publication - Aravind Vijayaraghavan
Department of Materials, The University of Manchester, Manchester, UK
1 shared publication - Christian Berger
School of Materials and National Graphene Institute, The University of Manchester, Booth St E, Manchester M13 9PL, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 6 November 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (44) , 17439-17449
Capacitive pressure sensing with suspended graphene–polymer heterostructure membranes
We describe the fabrication and characterisation of a capacitive pressure sensor formed by an ultra-thin graphene–polymer heterostructure membrane spanning a large array of micro-cavities each up to 30 μm in diameter with 100% yield. Sensors covering an area of just 1 mm2 show reproducible pressure transduction under static and dynamic loading up to pressures of 250 kPa. The measured capacitance change in response to pressure is in good agreement with calculations. Further, we demonstrate high-sensitivity pressure sensors by applying a novel strained membrane transfer and optimising the sensor architecture. This method enables suspended structures with less than 50 nm of air dielectric gap, giving a pressure sensitivity of 123 aF Pa−1 mm−2 over a pressure range of 0 to 100 kPa.
- 6 November 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (44) , 17439-17449
Open AccessCapacitive pressure sensing with suspended graphene–polymer heterostructure membranes
We describe the fabrication and characterisation of a capacitive pressure sensor formed by an ultra-thin graphene–polymer heterostructure membrane spanning a large array of micro-cavities each up to 30 μm in diameter with 100% yield. Sensors covering an area of just 1 mm2 show reproducible pressure transduction under static and dynamic loading up to pressures of 250 kPa. The measured capacitance change in response to pressure is in good agreement with calculations. Further, we demonstrate high-sensitivity pressure sensors by applying a novel strained membrane transfer and optimising the sensor architecture. This method enables suspended structures with less than 50 nm of air dielectric gap, giving a pressure sensitivity of 123 aF Pa−1 mm−2 over a pressure range of 0 to 100 kPa.