Maria Pimpinella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Pimpinella has a total of 222 co-authors. Here are the top co-authors by number of shared publications:
- Marco Marinelli
Industrial Engineering Department, Tor Vergata University of Rome, Via del Politecnico 1, 00133 Rome, Italy
9 shared publications A S Guerra
Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, Centro Ricerche ENEA Casaccia, Via Anguillarese 301, 00123 Santa Maria di Galeria, Roma, Italy
8 shared publicationsVanessa De Coste
ENEA-INMRI, National Institute of Ionizing Radiation Metrology, Rome, Italy
7 shared publicationsR F Laitano
6 shared publications- Gianluca Verona Rinati
University of Rome "Tor Vergata
5 shared publications - Pietro Mancosu
Radiotherapy and Radiosurgery Department, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
5 shared publications
Latest Publications
- Open Access
- 14 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104925
Dosimetry audit service in Italy: Results of the partnership between Italian Association of Medical Physics (AIFM) and Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI)
- 14 February 2025
- Published by Elsevier in Physica Medica
- Vol. 131, 104925
Open AccessDosimetry audit service in Italy: Results of the partnership between Italian Association of Medical Physics (AIFM) and Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI)
- 1 January 2020
- Published by Elsevier in Physica Medica
- Vol. 69, 127-133
Absorbed dose measurements from a 90Y radionuclide liquid solution using LiF:Mg,Cu,P thermoluminescent dosimeters
- 1 January 2020
- Published by Elsevier in Physica Medica
- Vol. 69, 127-133
Absorbed dose measurements from a 90Y radionuclide liquid solution using LiF:Mg,Cu,P thermoluminescent dosimeters
- Open Access
- 24 October 2019
- Published by Frontiers Media SA in Frontiers in Plant Science
- Vol. 10, 1334
Effects of Simulated Space Radiations on the Tomato Root Proteome
Plant cultivation on spacecraft or planetary outposts is a promising and actual perspective both for food and bioactive molecules production. To this aim, plant response to ionizing radiations, as an important component of space radiation, must be assessed through on-ground experiments due to the potentially fatal effects on living systems. Hereby, we investigated the effects of X-rays and γ-rays exposure on tomato “hairy root” cultures (HRCs), which represent a solid platform for the production of pharmaceutically relevant molecules, including metabolites and recombinant proteins. In a space application perspective, we used an HRC system previously fortified through the accumulation of anthocyanins, which are known for their anti-oxidant properties. Roots were independently exposed to different photon radiations, namely X-rays (250 kV) and γ-rays (Co60, 1.25 MeV), both at the absorbed dose levels of 0.5, 5, and 10 Gy. Molecular changes induced in the proteome of HRCs were investigated by a comparative approach based on two-dimensional difference in-gel electrophoresis (2D-DIGE) technology, which allowed to highlight dynamic processes activated by these environmental stresses. Results revealed a comparable response to both photon treatments. In particular, the presence of differentially represented proteins were observed only when roots were exposed to 5 or 10 Gy of X-rays or γ-rays, while no variations were appreciated at 0.5 Gy of both radiations, when compared with unexposed control. Differentially represented proteins were identified by mass spectrometry procedures and their functional interactions were analyzed, revealing variations in the activation of stress response integrated mechanisms as well as in carbon/energy and protein metabolism. Specific results from above-mentioned procedures were validated by immunoblotting. Finally, a morphometric analysis verified the absence of significant alterations in the development of HRCs, allowing to ascribe the observed variations of protein expression to processes of acclimation to ionizing radiations. Overall results contribute to a meaningful risk evaluation for biological systems exposed to extra-terrestrial environments, in the perspective of manned interplanetary missions planned for the near future.
- 24 October 2019
- Published by Frontiers Media SA in Frontiers in Plant Science
- Vol. 10, 1334
Open AccessEffects of Simulated Space Radiations on the Tomato Root Proteome
Plant cultivation on spacecraft or planetary outposts is a promising and actual perspective both for food and bioactive molecules production. To this aim, plant response to ionizing radiations, as an important component of space radiation, must be assessed through on-ground experiments due to the potentially fatal effects on living systems. Hereby, we investigated the effects of X-rays and γ-rays exposure on tomato “hairy root” cultures (HRCs), which represent a solid platform for the production of pharmaceutically relevant molecules, including metabolites and recombinant proteins. In a space application perspective, we used an HRC system previously fortified through the accumulation of anthocyanins, which are known for their anti-oxidant properties. Roots were independently exposed to different photon radiations, namely X-rays (250 kV) and γ-rays (Co60, 1.25 MeV), both at the absorbed dose levels of 0.5, 5, and 10 Gy. Molecular changes induced in the proteome of HRCs were investigated by a comparative approach based on two-dimensional difference in-gel electrophoresis (2D-DIGE) technology, which allowed to highlight dynamic processes activated by these environmental stresses. Results revealed a comparable response to both photon treatments. In particular, the presence of differentially represented proteins were observed only when roots were exposed to 5 or 10 Gy of X-rays or γ-rays, while no variations were appreciated at 0.5 Gy of both radiations, when compared with unexposed control. Differentially represented proteins were identified by mass spectrometry procedures and their functional interactions were analyzed, revealing variations in the activation of stress response integrated mechanisms as well as in carbon/energy and protein metabolism. Specific results from above-mentioned procedures were validated by immunoblotting. Finally, a morphometric analysis verified the absence of significant alterations in the development of HRCs, allowing to ascribe the observed variations of protein expression to processes of acclimation to ionizing radiations. Overall results contribute to a meaningful risk evaluation for biological systems exposed to extra-terrestrial environments, in the perspective of manned interplanetary missions planned for the near future.
- 1 May 2019
- Published by Elsevier in Physica Medica
- Vol. 61, 94-102
Output factor measurement in high dose-per-pulse IORT electron beams
- 1 May 2019
- Published by Elsevier in Physica Medica
- Vol. 61, 94-102
Output factor measurement in high dose-per-pulse IORT electron beams
- 1 March 2019
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 132, 218-222
Community approach for reducing small field measurement errors: Experience over 24 centres
- 1 March 2019
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 132, 218-222
Community approach for reducing small field measurement errors: Experience over 24 centres
- 1 January 2019
- Published by Elsevier in Physica Medica
- Vol. 57, 221-230
Calculation of kQ factors for Farmer-type ionization chambers following the recent recommendations on new key dosimetry data
- 1 January 2019
- Published by Elsevier in Physica Medica
- Vol. 57, 221-230
Calculation of kQ factors for Farmer-type ionization chambers following the recent recommendations on new key dosimetry data
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 106-116
Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 106-116
Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes
- Open Access
- 28 November 2017
- Published by Springer Nature in EJNMMI Research
- Vol. 7 (1) , 94
Phantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization
PET/CT has recently been shown to be a viable alternative to traditional post-infusion imaging methods providing good quality images of 90Y-laden microspheres after selective internal radiation therapy (SIRT). In the present paper, first we assessed the quantitative accuracy of 90Y-PET using an anthropomorphic phantom provided with lungs, liver, spine, and a cylindrical homemade lesion located into the hepatic compartment. Then, we explored the accuracy of different computational approaches on dose calculation, including (I) direct Monte Carlo radiation transport using Raydose, (II) Kernel convolution using Philips Stratos, (III) local deposition algorithm, (IV) Monte Carlo technique (MCNP) considering a uniform activity distribution, and (V) MIRD (Medical Internal Radiation Dose) analytical approach. Finally, calculated absorbed doses were compared with those obtained performing measurements with LiF:Mg,Cu,P TLD chips in a liquid environment. Our results indicate that despite 90Y-PET being likely to provide high-resolution images, the 90Y low branch ratio, along with other image-degrading factors, may produce non-uniform activity maps, even in the presence of uniform activity. A systematic underestimation of the recovered activity, both for the tumor insert and for the liver background, was found. This is particularly true if no partial volume correction is applied through recovery coefficients. All dose algorithms performed well, the worst case scenario providing an agreement between absorbed dose evaluations within 20%. Average absorbed doses determined with the local deposition method are in excellent agreement with those obtained using the MIRD and the kernel-convolution dose calculation approach. Finally, absorbed dose assessed with MC codes are in good agreement with those obtained using TLD in liquid solution, thus confirming the soundness of both calculation approaches. This is especially true for Raydose, which provided an absorbed dose value within 3% of the measured dose, well within the stated uncertainties. Patient-specific dosimetry is possible even in a scenario with low true coincidences and high random fraction, as in 90Y–PET imaging, granted that accurate absolute PET calibration is performed and acquisition times are sufficiently long. Despite Monte Carlo calculations seeming to outperform all dose estimation algorithms, our data provide a strong argument for encouraging the use of the local deposition algorithm for routine 90Y dosimetry based on PET/CT imaging, due to its simplicity of implementation.
- 28 November 2017
- Published by Springer Nature in EJNMMI Research
- Vol. 7 (1) , 94
Open AccessPhantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization
PET/CT has recently been shown to be a viable alternative to traditional post-infusion imaging methods providing good quality images of 90Y-laden microspheres after selective internal radiation therapy (SIRT). In the present paper, first we assessed the quantitative accuracy of 90Y-PET using an anthropomorphic phantom provided with lungs, liver, spine, and a cylindrical homemade lesion located into the hepatic compartment. Then, we explored the accuracy of different computational approaches on dose calculation, including (I) direct Monte Carlo radiation transport using Raydose, (II) Kernel convolution using Philips Stratos, (III) local deposition algorithm, (IV) Monte Carlo technique (MCNP) considering a uniform activity distribution, and (V) MIRD (Medical Internal Radiation Dose) analytical approach. Finally, calculated absorbed doses were compared with those obtained performing measurements with LiF:Mg,Cu,P TLD chips in a liquid environment. Our results indicate that despite 90Y-PET being likely to provide high-resolution images, the 90Y low branch ratio, along with other image-degrading factors, may produce non-uniform activity maps, even in the presence of uniform activity. A systematic underestimation of the recovered activity, both for the tumor insert and for the liver background, was found. This is particularly true if no partial volume correction is applied through recovery coefficients. All dose algorithms performed well, the worst case scenario providing an agreement between absorbed dose evaluations within 20%. Average absorbed doses determined with the local deposition method are in excellent agreement with those obtained using the MIRD and the kernel-convolution dose calculation approach. Finally, absorbed dose assessed with MC codes are in good agreement with those obtained using TLD in liquid solution, thus confirming the soundness of both calculation approaches. This is especially true for Raydose, which provided an absorbed dose value within 3% of the measured dose, well within the stated uncertainties. Patient-specific dosimetry is possible even in a scenario with low true coincidences and high random fraction, as in 90Y–PET imaging, granted that accurate absolute PET calibration is performed and acquisition times are sufficiently long. Despite Monte Carlo calculations seeming to outperform all dose estimation algorithms, our data provide a strong argument for encouraging the use of the local deposition algorithm for routine 90Y dosimetry based on PET/CT imaging, due to its simplicity of implementation.
- 5 October 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 102-108
OVERVIEW OF NEUTRON MEASUREMENTS IN JET FUSION DEVICE
The design and operation of ITER experimental fusion reactor requires the development of neutron measurement techniques and numerical tools to derive the fusion power and the radiation field in the device and in the surrounding areas. Nuclear analyses provide essential input to the conceptual design, optimisation, engineering and safety case in ITER and power plant studies. The required radiation transport calculations are extremely challenging because of the large physical extent of the reactor plant, the complexity of the geometry, and the combination of deep penetration and streaming paths. This article reports the experimental activities which are carried-out at JET to validate the neutronics measurements methods and numerical tools used in ITER and power plant design. A new deuterium–tritium campaign is proposed in 2019 at JET: the unique 14 MeV neutron yields produced will be exploited as much as possible to validate measurement techniques, codes, procedures and data currently used in ITER design thus reducing the related uncertainties and the associated risks in the machine operation.
- 5 October 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 102-108
OVERVIEW OF NEUTRON MEASUREMENTS IN JET FUSION DEVICE
The design and operation of ITER experimental fusion reactor requires the development of neutron measurement techniques and numerical tools to derive the fusion power and the radiation field in the device and in the surrounding areas. Nuclear analyses provide essential input to the conceptual design, optimisation, engineering and safety case in ITER and power plant studies. The required radiation transport calculations are extremely challenging because of the large physical extent of the reactor plant, the complexity of the geometry, and the combination of deep penetration and streaming paths. This article reports the experimental activities which are carried-out at JET to validate the neutronics measurements methods and numerical tools used in ITER and power plant design. A new deuterium–tritium campaign is proposed in 2019 at JET: the unique 14 MeV neutron yields produced will be exploited as much as possible to validate measurement techniques, codes, procedures and data currently used in ITER design thus reducing the related uncertainties and the associated risks in the machine operation.