MCMingxue Cai

Mingxue Cai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mingxue Cai has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Adaptive Path Planning for Autonomous Navigation of Reconfigurable Magnetic Microswarms

    by Siyu Liu, Mingxue Cai, Chenyang Huang, Guoyao Ma, Tiantian Xu

    Microrobot swarms have attracted growing attention due to their ability to adapt to environments during navigation through reconfigurable distributions. However, current microrobot swarms lack the intelligent behaviors to adjust their distributions and motion in response to dynamic environments and target changes. This work proposes a novel adaptive nonlinear model predictive path planning method incorporating distribution adaptation to achieve real-time adjustment of swarm distributions and paths in dynamic environments. First, we develop a criterion to evaluate navigation performance in the presence of obstacles, termed avoidance efficiency. Second, we develop a dynamic distribution planning strategy that adapts distributions based on environmental conditions, leveraging the reconfigurability of the magnetic nanoparticle swarm. Subsequently, we propose an adaptive nonlinear model predictive control-based strategy (A-NMPC) for swarm path planning with real-time distribution adaptation. Finally, magnetic nanoparticle swarms exhibit superior navigation performance in the presence of both static and dynamic obstacles, as well as moving targets. Notably, real-world experiments demonstrate that the proposed A-NMPC method, incorporating distribution adaptation, achieves a 24% reduction in path length and improved adaptability in complex, dynamic environments compared to conventional methods.

  • Top Cited Papers

    Long-term thrombus-free left atrial appendage occlusion via magnetofluids

    by Shu Wang, Wenhao Ju, Donglin Zhuang, Zhecheng Chen, Dongliang Zhao, Shunyuan Huang, Tiankuo Wang, Mingxue Cai, Siyu Liu, Shixiong Fu, et al.

    Peri-device leak and device-related thrombus1 remain key challenges of current left atrial appendage occlusion (LAAO)2 owing to the incompatibility between the solid occluder and the left atrial appendage (LAA). Here we propose a personalized and complete LAAO using magnetofluids that is suitable for all types of LAAs. Magnetofluids can be injected into LAAs from cardiac catheters. In the presence of a sufficient magnetic field, magnetofluids can resist high-speed blood flow. Magnetofluids can precipitate into magnetogels in contact with water in the blood within only a few minutes. We further confirmed the long-term resilience and biocompatibility of the magnetogel over 10 months in a pig model in vivo. Neither device-related thrombus nor magnetogel leakage was observed in any pigs. The endocardium formed on the Watchman occluder was rough and incomplete, predisposing to thrombosis. Myocardial injuries were unavoidable due to the barbs of the Watchman occluder. The endocardium formed on our magnetogel was smooth, firm and thrombus-free. No crevice was observed between our magnetogel and the LAA, and no injury was caused to the myocardium. These findings may offer a promising clinical strategy for long-term thrombus-free LAAO.


  • Open Access

    Superelastic Tellurium Thermoelectric Coatings for Advanced Trimodal Microsensing

    by Shaowei Cui, Linlin Li, Zi-Xin Huang, Yanzhe Yu, Mingxue Cai, Xiangyin Bao, Chaofan Zhang, Tiandong Zhang, Long Cheng, Wenxuan Zhang, et al.

    Tactile endoscopes can provide physicians with rich sensory information, enabling fast and accurate medical diagnoses. However, existing tactile endoscopy sensors do not consider temperature perception, which is a very important diagnostic indicator in medicine. Here, we report for the first time a tellurium-based superelastic thermoelectric visual-tactile sensor. This platform achieves a breakthrough by combining tellurium thermocouples designed based on crystal structures with viscoelastic silicone encapsulation, enabling simultaneous microscale visual, thermal, and force measurements in a single device. By employing a morphologically optimized tellurium-polymer heterointerface and advanced deep neural network algorithms, we address the inherent trade-off between transparency and responsiveness, achieving artifact-free imaging, real-time thermal mapping, and microstructure force feedback. We conduct clinical endoscopic palpation experiments on live rabbits and successfully achieve tactile diagnosis of inflamed tissue including temperature distribution, especially in cases where visual distinction is difficult, pointing out possible development directions for intelligent endoscopy systems.


  • Lyapunov-Constrained DRL for Robust Path Following of a Magnetic Microrobot in Dynamic Fluid Environments

    by Guoyao Ma, Yongfeng Huang, Jia Liu, Mingxue Cai, Sheng Xu, Chenyang Huang, Yingxin Huo, Dong Li, Shixiong Fu, Qianbi Peng, et al.

  • Open Access

    Magnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control

    by Yanfei Cao, Mingxue Cai, Bonan Sun, Zhaoyang Qi, Junnan Xue, Yihang Jiang, Bo Hao, Jiaqi Zhu, Xurui Liu, Chaoyu Yang, et al.

    Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .


  • Top Cited Papers
    Open Access

    Multifunctional Magnetic Catheter Robot with Triaxial Force Sensing Capability for Minimally Invasive Surgery

    by Shixiong Fu, Shiyuan Dong, Haolan Shen, Zhiqiang Chen, Guoyao Ma, Mingxue Cai, Chenyang Huang, Qianbi Peng, Chenyao Bai, Yuming Dong, et al.

    Magnetic continuum robots offer flexibility and controllability, making them promising for minimally invasive surgery (MIS). However, the clinical application of these robots is relatively limited due to the difficulty of integrating miniaturized triaxial force sensors and their single functionality. This paper proposes a multifunctional magnetic catheter robot with magnetic actuation steering and triaxial force-sensing capabilities. The robot features 3 channels at its tip that integrate multi-segmented magnets, a novel triaxial force sensor, and various functional instruments. The sensor is calibrated, demonstrating high sensitivity and accuracy. The steering characterization of the robot confirms that the catheter tip exhibits effective flexibility and force sensing. Palpation experiments involving various hard lumps are performed on porcine kidney, with results verifying that the robot can reliably detect abnormal hard lumps within tissues. Additionally, palpation experiments in bronchial phantom demonstrate the robot’s imaging and palpation capabilities for lung nodules with an integrated endoscope. Further, the robot, equipped with biopsy forceps, successfully performs palpation and biopsy functions on simulated stomach polyps, demonstrating its capability for effective tissue manipulation. By leveraging force-sensing capabilities and integrating multifunctional instruments, the robot shows potential for expanded applications in MIS, paving the way for important advancements in clinical procedures.


  • Performance-Guided Rotating Magnetic Field Control in Large Workspaces With Reconfigurable Electromagnetic Actuation System

    by Mingxue Cai, Zhaoyang Qi, Yanfei Cao, Xurui Liu, Xinyu Wu, Tiantian Xu, Li Zhang

    Remote-actuated magnetic robots, relying solely on the magnetic torque stemming from rotating magnetic fields, hold immense promise in biomedical applications. However, to precisely actuate magnetic robots in large workspaces, the efficient generation of isotropic rotating fields using electromagnetic actuation (EMA) systems presents an enduring challenge. This is because the choice of configuration of the EMA system is a major concern, particularly when considering collision avoidance between coils and the human body while ensuring isotropic actuation. In this study, we presented an analysis of the characteristics of various three-coil configurations by quantitatively evaluating field isotropy. Furthermore, we introduced a performance-guided optimization method to adjust coil configurations by optimizing designed evaluation metrics, aiming to generate rotating fields with isotropic characteristics in a target local region. Finally, we implemented a reconfigurable electromagnetic actuation system (REMA) and conducted extensive experiments to demonstrate the capability of our method and platform. The experimental results showcase the potential of our approach for advanced clinical applications.


  • Open Access

    Robust 3-D Path Following Control Framework for Magnetic Helical Millirobots Subject to Fluid Flow and Input Saturation

    by Zhaoyang Qi, Mingxue Cai, Bo Hao, Yanfei Cao, Lin Su, Xurui Liu, Kai Fung Chan, Chenguang Yang, Li Zhang

    Precise trajectory control is imperative to ensure the safety and efficacy of in vivo therapy employing the magnetic helical millirobots. However, achieving accurate 3-D path following of helical millirobots under fluid flow conditions remains challenging due to the presence of the lumped disturbances, encompassing complex fluid dynamics and input frequency saturation. This study proposes a robust 3-D path following control framework that combines a disturbance observer for perturbation estimation with an adaptive finite-time sliding mode controller for autonomous navigation along the reference trajectories. First, a magnetic helical millirobot’s kinematic model based on the 3-D hand position approach is established. Subsequently, a robust smooth differentiator is implemented as an observer to estimate disturbances within a finite time. We then investigate an adaptive finite-time sliding mode controller incorporating an auxiliary system to mitigate the estimated disturbance and achieve precise 3-D path tracking while respecting the input constraints. The adaptive mechanism of this controller ensures fast convergence of the system while alleviating the chattering effects. Finally, we provide a rigorous theoretical analysis of the finite-time stability of the closed-loop system based on the Lyapunov functions. Utilizing a robotically-actuated magnetic manipulation system, experimental results demonstrate the efficacy of the proposed approach in terms of the control accuracy and convergence time.