Hironori Matsuhisa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hironori Matsuhisa has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
Yoshihiro Oshima
Department of Cardiovascular Surgery, Kobe Children’s Hospital , Kobe
29 shared publications- Tomomi Hasegawa
Department of Cardiovascular Surgery, Kobe Children's Hospital, Hyogo, Japan
16 shared publications Ayako Maruo
Department of Cardiovascular Surgery, Kobe Children's Hospital, Hyogo, Japan
14 shared publicationsRei Noda
Department of Cardiovascular Surgery, Kobe Children's Hospital, Kobe, Hyogo, Japan
11 shared publications- Shunsuke Matsushima
Department of Cardiovascular Surgery, Kobe Children’s Hospital , Kobe 650-0047
7 shared publications Tsutomu Shida
7 shared publications
Latest Publications
- Open Access
- 24 May 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (6)
Reply to Hinpetch Daungsupawong et al.
- 24 May 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (6)
Open AccessReply to Hinpetch Daungsupawong et al.
- Open Access
- 2 March 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (3)
In Vitro Hydrodynamic Evaluation of Pulmonary Expanded Polytetrafluoroethylene Valved Conduits
Various designs are proposed for pulmonary expanded polytetrafluoroethylene conduits and have been applied in clinical practice. However, experimental data to support them are limited. We conducted an in vitro experiment using a circulatory simulator to evaluate their haemodynamic performance and hydrodynamic characteristics. Three root models with a 24-mm basal ring (A, straight; B, with small sinuses; C, with large sinuses) were 3 D-printed. Cusps were uniformly cut out from a 0.1-mm thick expanded polytetrafluoroethylene membrane and sewn to the inter wall of the models. Model A had a single suture on the free margins near the commissures. Each model was tested with a pump size of 70 ml, 70beats/min, and arterial pressure of 30/10 mmHg. The valve behaviour was recorded by a high-speed camera and particle image velocimetry was performed in the region behind the model housing section. Peak transvalvular pressure gradients were 4.0 mmHg, 4.8 mmHg, and 4.3 mmHg (p = 0.95), and geometric orifice areas were 2.34cm2, 2.38cm2, and 2.46cm2 (p = 0.96) in model A, B, and C, respectively. Particle image velocimetry revealed peak instantaneous velocity was 1.69 m/s, 1.69 m/s, and 1.65 m/s (p = 0.74) and peak Reynolds shear stress in midsystolic phase was 56.8 Pa, 49.5 Pa, and 25.5 Pa (p = 0.05) in model A, B, and C, respectively. Model C tended to have lower distribution of turbulent flow than the other models. All models exhibited sufficient opening and acceptable Reynolds shear stress values. The sinus contributed to suppression of turbulent flow, which may lead to improvement of conduit durability, but its effect was dependent on the sinus size.
- 2 March 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (3)
Open AccessIn Vitro Hydrodynamic Evaluation of Pulmonary Expanded Polytetrafluoroethylene Valved Conduits
Various designs are proposed for pulmonary expanded polytetrafluoroethylene conduits and have been applied in clinical practice. However, experimental data to support them are limited. We conducted an in vitro experiment using a circulatory simulator to evaluate their haemodynamic performance and hydrodynamic characteristics. Three root models with a 24-mm basal ring (A, straight; B, with small sinuses; C, with large sinuses) were 3 D-printed. Cusps were uniformly cut out from a 0.1-mm thick expanded polytetrafluoroethylene membrane and sewn to the inter wall of the models. Model A had a single suture on the free margins near the commissures. Each model was tested with a pump size of 70 ml, 70beats/min, and arterial pressure of 30/10 mmHg. The valve behaviour was recorded by a high-speed camera and particle image velocimetry was performed in the region behind the model housing section. Peak transvalvular pressure gradients were 4.0 mmHg, 4.8 mmHg, and 4.3 mmHg (p = 0.95), and geometric orifice areas were 2.34cm2, 2.38cm2, and 2.46cm2 (p = 0.96) in model A, B, and C, respectively. Particle image velocimetry revealed peak instantaneous velocity was 1.69 m/s, 1.69 m/s, and 1.65 m/s (p = 0.74) and peak Reynolds shear stress in midsystolic phase was 56.8 Pa, 49.5 Pa, and 25.5 Pa (p = 0.05) in model A, B, and C, respectively. Model C tended to have lower distribution of turbulent flow than the other models. All models exhibited sufficient opening and acceptable Reynolds shear stress values. The sinus contributed to suppression of turbulent flow, which may lead to improvement of conduit durability, but its effect was dependent on the sinus size.
- 30 September 2025
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (10)
Anterior Pulmonary Artery Translocation with the Damus-Kaye-Stansel and Rastelli Procedures for Multilevel Tracheobronchomalacia with Double-Outlet Right Ventricle (S, D, L) and Right Pulmonary Agenesis
In patients with unilateral pulmonary agenesis, airway compression often occurs due to mediastinal and cardiovascular deviations and remains a therapeutic challenge. We present the case with multilevel tracheobronchomalacia associated with double-outlet right ventricle (S, D, L) and right pulmonary agenesis who was treated using anterior pulmonary artery translocation with the Damus-Kaye-Stansel and Rastelli procedure.
- 30 September 2025
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 67 (10)
Anterior Pulmonary Artery Translocation with the Damus-Kaye-Stansel and Rastelli Procedures for Multilevel Tracheobronchomalacia with Double-Outlet Right Ventricle (S, D, L) and Right Pulmonary Agenesis
In patients with unilateral pulmonary agenesis, airway compression often occurs due to mediastinal and cardiovascular deviations and remains a therapeutic challenge. We present the case with multilevel tracheobronchomalacia associated with double-outlet right ventricle (S, D, L) and right pulmonary agenesis who was treated using anterior pulmonary artery translocation with the Damus-Kaye-Stansel and Rastelli procedure.
- 18 August 2025
- Published by Elsevier in Operative Techniques in Thoracic and Cardiovascular Surgery
- Vol. 30 (4) , 295-302
Patch Augmentation of Superior Bridging Leaflet in Rastelli Type A Atrioventricular Septal Defect Repair
- 18 August 2025
- Published by Elsevier in Operative Techniques in Thoracic and Cardiovascular Surgery
- Vol. 30 (4) , 295-302
Patch Augmentation of Superior Bridging Leaflet in Rastelli Type A Atrioventricular Septal Defect Repair
- Open Access
- 5 February 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 40 (2)
Pulmonary expanded polytetrafluoroethylene conduits with a hand-sewn tricuspid valve
OBJECTIVES: The biocompatibility of expanded polytetrafluoroethylene in the pulmonary position seems better than allogenic or xenogeneic reactivity. This study reviewed the application of pulmonary expanded polytetrafluoroethylene conduits having a hand-sewn tricuspid valve with diameters of 18–24 mm. METHODS: All patients receiving this conduit between 2010 and 2022 were evaluated. A 0.1-mm-thick membrane and a standard-wall tube of expanded polytetrafluoroethylene were used for cusp and conduit material, respectively. RESULTS: Eighty-four consecutive patients were included. The median operative age and weight were 12 (range, 1.2–40) years and 34 (range, 9.1–82) kg, respectively. Eighteen-, 20-, 22- and 24-mm conduits were used in 19, 5, 3 and 57 patients, respectively. The overall survival was 94% at 5 and 10 years with four non-valve-related deaths. There were five conduit replacements, all for 18-mm conduit stenosis. Freedom from conduit replacement was 98% and 83% at 5 and 10 years, respectively. Freedom from conduit stenosis ≥ moderate was 83% and 54% at 5 and 10 years, respectively. Freedom from pulmonary regurgitation ≥ moderate was 98% at 5 and 10 years. Linear mixed-effects models with echocardiographic data implied that 24-mm conduits functioned with a peak velocity 12 years postoperatively. CONCLUSIONS: This conduit has shown favourable clinical outcomes and is a valid alternative, especially in young patients with increased risk for early failure of the existing products.
- 5 February 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 40 (2)
Open AccessPulmonary expanded polytetrafluoroethylene conduits with a hand-sewn tricuspid valve
OBJECTIVES: The biocompatibility of expanded polytetrafluoroethylene in the pulmonary position seems better than allogenic or xenogeneic reactivity. This study reviewed the application of pulmonary expanded polytetrafluoroethylene conduits having a hand-sewn tricuspid valve with diameters of 18–24 mm. METHODS: All patients receiving this conduit between 2010 and 2022 were evaluated. A 0.1-mm-thick membrane and a standard-wall tube of expanded polytetrafluoroethylene were used for cusp and conduit material, respectively. RESULTS: Eighty-four consecutive patients were included. The median operative age and weight were 12 (range, 1.2–40) years and 34 (range, 9.1–82) kg, respectively. Eighteen-, 20-, 22- and 24-mm conduits were used in 19, 5, 3 and 57 patients, respectively. The overall survival was 94% at 5 and 10 years with four non-valve-related deaths. There were five conduit replacements, all for 18-mm conduit stenosis. Freedom from conduit replacement was 98% and 83% at 5 and 10 years, respectively. Freedom from conduit stenosis ≥ moderate was 83% and 54% at 5 and 10 years, respectively. Freedom from pulmonary regurgitation ≥ moderate was 98% at 5 and 10 years. Linear mixed-effects models with echocardiographic data implied that 24-mm conduits functioned with a peak velocity 12 years postoperatively. CONCLUSIONS: This conduit has shown favourable clinical outcomes and is a valid alternative, especially in young patients with increased risk for early failure of the existing products.
- 24 June 2023
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 167 (2) , 439-449.e6
Expanded polytetrafluoroethylene conduits with curved and handsewn bileaflet designs for right ventricular outflow tract reconstruction
- 24 June 2023
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 167 (2) , 439-449.e6
Expanded polytetrafluoroethylene conduits with curved and handsewn bileaflet designs for right ventricular outflow tract reconstruction
- 4 February 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (6) , 1290-1297
Surgical outcomes of pulmonary artery sling and congenital tracheal stenosis with right lung anomaly
OBJECTIVES: This study aimed to investigate whether computed tomographic indices support surgical decision-making in patients with pulmonary artery sling, congenital tracheal stenosis and right lung underdevelopment. METHODS: A total of 38 patients with pulmonary artery sling and congenital tracheal stenosis underwent tracheoplasty. Patients were divided into 3 groups based on anatomical categorization: group normal lung (NL; n = 21), group H (right lung hypoplasia, n = 12) and group A (right lung agenesis or aplasia, n = 5). Using preoperative computed tomographic images, the severity of the tracheal bending due to the right posterior deviation of the aortic arch and the relative length of the left pulmonary artery for reimplantation was evaluated. RESULTS: Slide tracheoplasty posterior to the aortic arch with pulmonary artery reimplantation was performed in 32 patients (21, 10 and 1 in groups NL, H and A, respectively). Slide tracheoplasty anterior to the aortic arch was performed in 4 patients (2 patients each in groups H and A). Among the 6 patients with severe tracheal bending who underwent slide tracheoplasty posterior to the aortic arch, 5 required aortopexy for tracheomalacia. The overall mortality rate was 3% (group NL, n = 1). The relative length of the left pulmonary artery in group H (0.85) was significantly shorter than that in group NL (1.36, P < 0.0001). CONCLUSIONS: In patients with right lung underdevelopment, preoperative computed tomography elucidated the tracheal bending due to right posterior deviation of the aortic arch, which compromised tracheoplasty and shortness of the left pulmonary artery for pulmonary artery sling repair.
- 4 February 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (6) , 1290-1297
Surgical outcomes of pulmonary artery sling and congenital tracheal stenosis with right lung anomaly
OBJECTIVES: This study aimed to investigate whether computed tomographic indices support surgical decision-making in patients with pulmonary artery sling, congenital tracheal stenosis and right lung underdevelopment. METHODS: A total of 38 patients with pulmonary artery sling and congenital tracheal stenosis underwent tracheoplasty. Patients were divided into 3 groups based on anatomical categorization: group normal lung (NL; n = 21), group H (right lung hypoplasia, n = 12) and group A (right lung agenesis or aplasia, n = 5). Using preoperative computed tomographic images, the severity of the tracheal bending due to the right posterior deviation of the aortic arch and the relative length of the left pulmonary artery for reimplantation was evaluated. RESULTS: Slide tracheoplasty posterior to the aortic arch with pulmonary artery reimplantation was performed in 32 patients (21, 10 and 1 in groups NL, H and A, respectively). Slide tracheoplasty anterior to the aortic arch was performed in 4 patients (2 patients each in groups H and A). Among the 6 patients with severe tracheal bending who underwent slide tracheoplasty posterior to the aortic arch, 5 required aortopexy for tracheomalacia. The overall mortality rate was 3% (group NL, n = 1). The relative length of the left pulmonary artery in group H (0.85) was significantly shorter than that in group NL (1.36, P < 0.0001). CONCLUSIONS: In patients with right lung underdevelopment, preoperative computed tomography elucidated the tracheal bending due to right posterior deviation of the aortic arch, which compromised tracheoplasty and shortness of the left pulmonary artery for pulmonary artery sling repair.
- 1 October 2020
- Published by The Japanese Society of Pediatric Cardiology and Cardiac Surgery in Pediatric Cardiology and Cardiac Surgery
- Vol. 36 (3) , 263-268
Symptomatic Portosystemic Shunt via the Unligated Vertical Vein Following Repair of a Mixed-Type Total Anomalous Pulmonary Venous Connection: A Case Report
機能的単心室を有する無脾症児の総肺静脈還流異常症(TAPVC)に対する修復術では,肺静脈還流の形態により術後肺静脈閉塞のリスクを考慮して,垂直静脈を処理せずに修復する術式を選択する場合がある.今回,混合型TAPVC修復術後の遺残垂直静脈を介して症候性門脈体循環シャント(PSS)を来した稀な症例を経験したので報告する.症例は混合型TAPVCの無脾症男児で,日齢18にTAPVC修復術を施行した.左上大静脈に還流する右肺静脈と,門脈に還流する左肺静脈を別々に心房に吻合し,左右の垂直静脈はいずれも放置した.術後に肝逸脱酵素上昇,凝固能異常,低血糖,高アンモニア血症を認め,遺残垂直静脈をシャント血管とする症候性PSSと診断した.症状は保存的治療で改善したが,将来,Fontan循環に向かう血行動態への影響を考慮し,遺残垂直静脈絞扼術を施行した.門脈への異常還流を伴う混合型TAPVCでは,単心室血行動態において遺残垂直静脈を介したPSSを来しうるため,これを念頭においた術前精査や術式検討,周術期管理が必要である.
- 1 October 2020
- Published by The Japanese Society of Pediatric Cardiology and Cardiac Surgery in Pediatric Cardiology and Cardiac Surgery
- Vol. 36 (3) , 263-268
Symptomatic Portosystemic Shunt via the Unligated Vertical Vein Following Repair of a Mixed-Type Total Anomalous Pulmonary Venous Connection: A Case Report
機能的単心室を有する無脾症児の総肺静脈還流異常症(TAPVC)に対する修復術では,肺静脈還流の形態により術後肺静脈閉塞のリスクを考慮して,垂直静脈を処理せずに修復する術式を選択する場合がある.今回,混合型TAPVC修復術後の遺残垂直静脈を介して症候性門脈体循環シャント(PSS)を来した稀な症例を経験したので報告する.症例は混合型TAPVCの無脾症男児で,日齢18にTAPVC修復術を施行した.左上大静脈に還流する右肺静脈と,門脈に還流する左肺静脈を別々に心房に吻合し,左右の垂直静脈はいずれも放置した.術後に肝逸脱酵素上昇,凝固能異常,低血糖,高アンモニア血症を認め,遺残垂直静脈をシャント血管とする症候性PSSと診断した.症状は保存的治療で改善したが,将来,Fontan循環に向かう血行動態への影響を考慮し,遺残垂直静脈絞扼術を施行した.門脈への異常還流を伴う混合型TAPVCでは,単心室血行動態において遺残垂直静脈を介したPSSを来しうるため,これを念頭においた術前精査や術式検討,周術期管理が必要である.
- 12 February 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (2) , 237-245
Computed tomography-based surgical strategy for total anomalous pulmonary venous connection
OBJECTIVES: We used computed tomographic angiography (CTA)-based surgical planning to clarify the anatomical indications of sutureless repair technique for total anomalous pulmonary venous connection. The mid-term impact of the current surgical strategies was evaluated. METHODS: One hundred twelve patients underwent repair for total anomalous pulmonary venous connection. The study period was divided into era 1 (1996–2010, n = 56) and era 2 (2011–2018, n = 56). Patients with single ventricular heart (SVH) were included. In era 2, the indications for primary sutureless repair and branch pulmonary vein incision were based on CTA findings. RESULTS: For patients with biventricular heart, the 5-year survival was 69% and 97% in eras 1 and 2, respectively (P = 0.0024). For patients with SVH, the 5-year survival was 21% and 70% in eras 1 and 2, respectively (P = 0.0007). During the follow-up period, the evidence of post-repair pulmonary vein stenosis (PVS) was observed in 12 patients with biventricular heart [era 1, 8 patients (23%); era 2, 4 patients (13%)], and 14 patients with SVH [era 1, 6 patients (60%); era 2, 8 patients (36%)]. Using multivariable analysis, preoperative CTA was associated with improved survival in both biventricular heart and SVH and associated with post-repair PVS-free survival in SVH. Since 2011, 12 patients with post-repair PVS underwent multiple reintervention with 1 recorded death (5-year survival: 88%). CONCLUSIONS: CTA-based surgical strategy for total anomalous pulmonary venous connection provided significant survival benefit. Although post-repair PVS could occur in era 2, aggressive reintervention appeared to be associated with improved survival and vein patency.
- 12 February 2020
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 58 (2) , 237-245
Computed tomography-based surgical strategy for total anomalous pulmonary venous connection
OBJECTIVES: We used computed tomographic angiography (CTA)-based surgical planning to clarify the anatomical indications of sutureless repair technique for total anomalous pulmonary venous connection. The mid-term impact of the current surgical strategies was evaluated. METHODS: One hundred twelve patients underwent repair for total anomalous pulmonary venous connection. The study period was divided into era 1 (1996–2010, n = 56) and era 2 (2011–2018, n = 56). Patients with single ventricular heart (SVH) were included. In era 2, the indications for primary sutureless repair and branch pulmonary vein incision were based on CTA findings. RESULTS: For patients with biventricular heart, the 5-year survival was 69% and 97% in eras 1 and 2, respectively (P = 0.0024). For patients with SVH, the 5-year survival was 21% and 70% in eras 1 and 2, respectively (P = 0.0007). During the follow-up period, the evidence of post-repair pulmonary vein stenosis (PVS) was observed in 12 patients with biventricular heart [era 1, 8 patients (23%); era 2, 4 patients (13%)], and 14 patients with SVH [era 1, 6 patients (60%); era 2, 8 patients (36%)]. Using multivariable analysis, preoperative CTA was associated with improved survival in both biventricular heart and SVH and associated with post-repair PVS-free survival in SVH. Since 2011, 12 patients with post-repair PVS underwent multiple reintervention with 1 recorded death (5-year survival: 88%). CONCLUSIONS: CTA-based surgical strategy for total anomalous pulmonary venous connection provided significant survival benefit. Although post-repair PVS could occur in era 2, aggressive reintervention appeared to be associated with improved survival and vein patency.
- 1 March 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 107 (3) , e227-e228
Left Atrial Decompression by Minithoracotomy During Extracorporeal Life Support
- 1 March 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 107 (3) , e227-e228
Left Atrial Decompression by Minithoracotomy During Extracorporeal Life Support