Milan Štědrý
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Milan Štědrý has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bohuslav Gaš
Berlin) Christian Klampfl (Linz)
11 shared publications Ernst Kenndler
Institute of Analytical Chemistry, University of Vienna, Vienna, Austria
6 shared publicationsMichal Jaroš
Faculty of Science, Charles University, Prague, Czech Republic
4 shared publicationsKateřina Včeláková
Faculty of Science, Charles University, Prague, Czech Republic
2 shared publicationsOtto Vejvoda
2 shared publicationsVlastimil Hruška
Faculty of Science, Charles University, Prague, Czech Republic
2 shared publications
Latest Publications
- 29 November 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (23) , 4610-4617
Eigenmobilities in background electrolytes for CZE. V. Intensity (amplitudes) of system peaks
We present a mathematical model of CZE based on the concept of eigenmobilities – the eigenvalues of matrix M tied to the linearized governing equations of electromigration, and the spectral decomposition of matrix M into matrices of amplitudes Pj. Any peak in an electropherogram, regardless of whether it is an analyte peak or a system peak (system zone), is matched with its matrix Pj. This enables calculation of the peak parameters, such as the transfer ratio and the molar conductivity detection response (which give the indirect detection signal and the conductivity detection signal, respectively), when the initial disturbance caused by the injection of the sample is known. We also introduce new quantities, such as the generalized transfer ratio and the conductivity response of system zones, and show how the amplitude (intensity, area) of the analyte peaks and the system peaks can be calculated. We offer a free software, PeakMaster (http://www.natur.cuni.cz/gas), which yields this information in a user-friendly way.
- 29 November 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (23) , 4610-4617
Eigenmobilities in background electrolytes for CZE. V. Intensity (amplitudes) of system peaks
We present a mathematical model of CZE based on the concept of eigenmobilities – the eigenvalues of matrix M tied to the linearized governing equations of electromigration, and the spectral decomposition of matrix M into matrices of amplitudes Pj. Any peak in an electropherogram, regardless of whether it is an analyte peak or a system peak (system zone), is matched with its matrix Pj. This enables calculation of the peak parameters, such as the transfer ratio and the molar conductivity detection response (which give the indirect detection signal and the conductivity detection signal, respectively), when the initial disturbance caused by the injection of the sample is known. We also introduce new quantities, such as the generalized transfer ratio and the conductivity response of system zones, and show how the amplitude (intensity, area) of the analyte peaks and the system peaks can be calculated. We offer a free software, PeakMaster (http://www.natur.cuni.cz/gas), which yields this information in a user-friendly way.
- 7 October 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (18-19) , 3071-3079
Eigenmobilities in background electrolytes for capillary zone electrophoresis: III. Linear theory of electromigration
A mathematical model of capillary zone electrophoresis (CZE) based on the conception of eigenmobilities, which are the eigenvalues of a matrix M tied to the linearized governing equations is presented. The model considers CZE systems, where constituents, either analytes or components of the background electrolyte (BGE), are weak electrolytes – acids, bases, or ampholytes. There is no restriction on the number of components nor on the valence of the constituents nor on pH of the BGE. An electrophoretic system with N constituents has N eigenmobilities. In most BGEs one or two eigenmobilities are very close to zero so their corresponding eigenzones move very slowly. However, there are BGEs where no eigenmobility is close to zero. The mathematical model further provides: the transfer ratio, the molar conductivity detection response, and the relative velocity slope. This allows the assessment of the indirect detection, conductivity detection and peak broadening (distortion) due to electromigration dispersion. Also, we present a spectral decomposition of the matrix M to matrices allowing the assessment of the amplitudes of system eigenpeaks (system peaks). Our model predicted the existence of BGEs having no stationary injection zone (or water zone, gap, peak, dip). A common practice of using the injection zone as a marker of the electroosmotic flow must fail in such electrolytes.
- 7 October 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (18-19) , 3071-3079
Eigenmobilities in background electrolytes for capillary zone electrophoresis: III. Linear theory of electromigration
A mathematical model of capillary zone electrophoresis (CZE) based on the conception of eigenmobilities, which are the eigenvalues of a matrix M tied to the linearized governing equations is presented. The model considers CZE systems, where constituents, either analytes or components of the background electrolyte (BGE), are weak electrolytes – acids, bases, or ampholytes. There is no restriction on the number of components nor on the valence of the constituents nor on pH of the BGE. An electrophoretic system with N constituents has N eigenmobilities. In most BGEs one or two eigenmobilities are very close to zero so their corresponding eigenzones move very slowly. However, there are BGEs where no eigenmobility is close to zero. The mathematical model further provides: the transfer ratio, the molar conductivity detection response, and the relative velocity slope. This allows the assessment of the indirect detection, conductivity detection and peak broadening (distortion) due to electromigration dispersion. Also, we present a spectral decomposition of the matrix M to matrices allowing the assessment of the amplitudes of system eigenpeaks (system peaks). Our model predicted the existence of BGEs having no stationary injection zone (or water zone, gap, peak, dip). A common practice of using the injection zone as a marker of the electroosmotic flow must fail in such electrolytes.
- 7 October 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (18-19) , 3080-3085
Eigenmobilities in background electrolytes for capillary zone electrophoresis: IV. Computer program PeakMaster
We are introducing a computer implementation of the mathematical model of zone electrophoresis (CZE) described in Štědrý, M., Jaroš, M., Hruška, V., Gaš, B., Electrophoresis 2004, 25, 3071–3079 program PeakMaster. The computer model calculates eigenmobilities, which are the eigenvalues of the matrix tied to the linearized continuity equations, and which are responsible for the presence of system eigenzones (system zones, system peaks). The model also calculates other parameters of the background electrolyte (BGE) – pH, conductivity, buffer capacity, ionic strength, etc., and parameters of the separated analytes – effective mobility, transfer ratio, molar conductivity detection response, and relative velocity slope. This allows the assessment of the indirect detection, conductivity detection and peak broadening (peak distortion) due to electromigration dispersion. The computer model requires the input of the BGE composition, the list of analytes to be separated, and the system instrumental configuration. The output parameters of the model are directly comparable with experiments; the model also simulates electropherograms in a user‐friendly way. We demonstrate a successful application of PeakMaster for inspection of BGEs having no stationary injection zone.
- 7 October 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (18-19) , 3080-3085
Eigenmobilities in background electrolytes for capillary zone electrophoresis: IV. Computer program PeakMaster
We are introducing a computer implementation of the mathematical model of zone electrophoresis (CZE) described in Štědrý, M., Jaroš, M., Hruška, V., Gaš, B., Electrophoresis 2004, 25, 3071–3079 program PeakMaster. The computer model calculates eigenmobilities, which are the eigenvalues of the matrix tied to the linearized continuity equations, and which are responsible for the presence of system eigenzones (system zones, system peaks). The model also calculates other parameters of the background electrolyte (BGE) – pH, conductivity, buffer capacity, ionic strength, etc., and parameters of the separated analytes – effective mobility, transfer ratio, molar conductivity detection response, and relative velocity slope. This allows the assessment of the indirect detection, conductivity detection and peak broadening (peak distortion) due to electromigration dispersion. The computer model requires the input of the BGE composition, the list of analytes to be separated, and the system instrumental configuration. The output parameters of the model are directly comparable with experiments; the model also simulates electropherograms in a user‐friendly way. We demonstrate a successful application of PeakMaster for inspection of BGEs having no stationary injection zone.
- 30 January 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (3) , 536-547
Eigenmobilities in background electrolytes for capillary zone electrophoresis: II. Eigenpeaks in univalent weak electrolytes
We analyze in detail a mathematical model of capillary zone electrophoresis (CZE) based on the conception of eigenmobilities, which are eigenvalues of the matrix tied to the linearized continuity equations. Our model considers CZE systems, where constituents are weak electrolytes and where pH of the background electrolyte may reach the full range from 0 to 14. Both hydrogen and hydroxide ions are taken into account in relations for conductivity and electroneutrality. An electrophoretic system with N constituents has N eigenmobilities. We reveal that two of the eigenmobilities have a special meaning as they exist due to the presence of hydrogen ions and hydroxide ions (in water solutions). These two eigenmobilities are responsible for the existence of two corresponding system zones (system peaks). We show that the stationary zone (injection zone, water zone, gap, peak, dip) is in many common background electrolytes composed of these two eigenzones which overlap, due to their very low electrophoretic mobility, into one zone. Other eigenmobilities give rise to system zones originating due to a possible existence of double (or multiple) coconstituents in the background electrolyte. The last group of eigenmobilities is connected with the movement of eigenzones accompanying analytes and enabling their indirect UV or conductivity detection. The model allows assessing experimentally available quantities such as effective mobility of the analyte, molar conductivity detection response, transfer ratio, and relative velocity slope and gives a picture about migration of analytes, their electromigration dispersion and signals obtained in detectors. It allows computer simulation of electropherograms and enables optimization of background electrolytes.
- 30 January 2003
- Published by Wiley in Electrophoresis
- Vol. 24 (3) , 536-547
Eigenmobilities in background electrolytes for capillary zone electrophoresis: II. Eigenpeaks in univalent weak electrolytes
We analyze in detail a mathematical model of capillary zone electrophoresis (CZE) based on the conception of eigenmobilities, which are eigenvalues of the matrix tied to the linearized continuity equations. Our model considers CZE systems, where constituents are weak electrolytes and where pH of the background electrolyte may reach the full range from 0 to 14. Both hydrogen and hydroxide ions are taken into account in relations for conductivity and electroneutrality. An electrophoretic system with N constituents has N eigenmobilities. We reveal that two of the eigenmobilities have a special meaning as they exist due to the presence of hydrogen ions and hydroxide ions (in water solutions). These two eigenmobilities are responsible for the existence of two corresponding system zones (system peaks). We show that the stationary zone (injection zone, water zone, gap, peak, dip) is in many common background electrolytes composed of these two eigenzones which overlap, due to their very low electrophoretic mobility, into one zone. Other eigenmobilities give rise to system zones originating due to a possible existence of double (or multiple) coconstituents in the background electrolyte. The last group of eigenmobilities is connected with the movement of eigenzones accompanying analytes and enabling their indirect UV or conductivity detection. The model allows assessing experimentally available quantities such as effective mobility of the analyte, molar conductivity detection response, transfer ratio, and relative velocity slope and gives a picture about migration of analytes, their electromigration dispersion and signals obtained in detectors. It allows computer simulation of electropherograms and enables optimization of background electrolytes.
- 1 January 1997
- Published by Wiley in Electrophoresis
- Vol. 18 (12-13) , 2123-2133
Peak broadening in capillary zone electrophoresis
A review on peak broadening in capillary zone electrophoresis in free solutions is given which covers a selection of the literature published on this topic over the period mainly between 1992 and the beginning of 1997 (consisting of 71 publications). The contributions to peak dispersion from extracolumn effects (e.g. due to the finite length of the injection zone, or the aperture of the detector), from longitudinal diffusion, Joule heating, electromigration dispersion (concentration overload), a different path length of the solute ions, wall adsorption, laminar flow and the (longitudinally) homogeneous or nonhomogeneous electroosmotic flow are described. The latter may also occur when a longitudinally nonhomogeneous radial electric field is applied. Peak dispersion is depicted either by the plate‐height model, or the concentration of the solute as a function of space and time is calculated either analytically or numerically by solving the equation of continuity with appropriate initial and boundary conditions and possibly completed by equations governing further quantities.
- 1 January 1997
- Published by Wiley in Electrophoresis
- Vol. 18 (12-13) , 2123-2133
Peak broadening in capillary zone electrophoresis
A review on peak broadening in capillary zone electrophoresis in free solutions is given which covers a selection of the literature published on this topic over the period mainly between 1992 and the beginning of 1997 (consisting of 71 publications). The contributions to peak dispersion from extracolumn effects (e.g. due to the finite length of the injection zone, or the aperture of the detector), from longitudinal diffusion, Joule heating, electromigration dispersion (concentration overload), a different path length of the solute ions, wall adsorption, laminar flow and the (longitudinally) homogeneous or nonhomogeneous electroosmotic flow are described. The latter may also occur when a longitudinally nonhomogeneous radial electric field is applied. Peak dispersion is depicted either by the plate‐height model, or the concentration of the solute as a function of space and time is calculated either analytically or numerically by solving the equation of continuity with appropriate initial and boundary conditions and possibly completed by equations governing further quantities.
- 1 January 1996
- Published by Wiley in Electrophoresis
- Vol. 17 (6) , 1121-1125
Influence of transference number on migration and deformation of concentration boundaries in capillary zone electrophoresis
The change of the position and shape of a concentration boundary existing in the background electrolyte in capillary zone electrophoresis is teated theoretically. Such boundaries may occur when the ionic concentration, c, of the sample differs from that of the background electrolyte. Both mathematical treatment and numerical simulation lead to the result that when an (initially symmetrical) concentration boundary migrates in the capillary it becomes nonsymmetrical. The reason for this is the nonsymmetry of the function, which is obtained as the difference of the transference number (which is a function depending on c) and its linear approximation at the average value of the concentration. Numerical simulations for capillary zone electrophoresis with LiI or potassium benzorate as a hypothetical background electrolyte show the formation of asymmetrical plugs for samples of more diluted electrolyte solutions.
- 1 January 1996
- Published by Wiley in Electrophoresis
- Vol. 17 (6) , 1121-1125
Influence of transference number on migration and deformation of concentration boundaries in capillary zone electrophoresis
The change of the position and shape of a concentration boundary existing in the background electrolyte in capillary zone electrophoresis is teated theoretically. Such boundaries may occur when the ionic concentration, c, of the sample differs from that of the background electrolyte. Both mathematical treatment and numerical simulation lead to the result that when an (initially symmetrical) concentration boundary migrates in the capillary it becomes nonsymmetrical. The reason for this is the nonsymmetry of the function, which is obtained as the difference of the transference number (which is a function depending on c) and its linear approximation at the average value of the concentration. Numerical simulations for capillary zone electrophoresis with LiI or potassium benzorate as a hypothetical background electrolyte show the formation of asymmetrical plugs for samples of more diluted electrolyte solutions.
- 1 November 1995
- Vol. 16 (11) , 2034-8
Contribution of capillary coiling to zone dispersion in capillary zone electrophoresis.
A mathematical model of the deformation of the analyte zone in capillary zone electrophoresis (CZE) due to capillary coiling is presented and the influence of capillary coiling on the distribution of electric current density inside the capillary is described. The model gives a quantitative description of the potential contribution of capillary coiling to the total zone dispersion in CZE. The zone broadening caused by capillary coiling is calculated as the difference of migration distances of the particles migrating at the inner circumference of the capillary coil and those migrating at the outer circumference. This difference is shown to be directly proportional to the capillary diameter and to the number of capillary coils, i.e. indirectly proportional to the radius of the capillary coils into which the capillary of the given length is coiled. The contribution of capillary coiling to the total zone dispersion is compared with the contribution of the longitudinal diffusion of low and high molecular mass analytes and bioparticles. It is shown that, especially in the case of CZE separation of macromolecules and particles, capillary coiling can significantly decrease the separation efficiency. For that reason the small radius coiling of the capillary column in the CZE apparatuses should be avoided.
- 1 November 1995
- Vol. 16 (11) , 2034-8
Contribution of capillary coiling to zone dispersion in capillary zone electrophoresis.
A mathematical model of the deformation of the analyte zone in capillary zone electrophoresis (CZE) due to capillary coiling is presented and the influence of capillary coiling on the distribution of electric current density inside the capillary is described. The model gives a quantitative description of the potential contribution of capillary coiling to the total zone dispersion in CZE. The zone broadening caused by capillary coiling is calculated as the difference of migration distances of the particles migrating at the inner circumference of the capillary coil and those migrating at the outer circumference. This difference is shown to be directly proportional to the capillary diameter and to the number of capillary coils, i.e. indirectly proportional to the radius of the capillary coils into which the capillary of the given length is coiled. The contribution of capillary coiling to the total zone dispersion is compared with the contribution of the longitudinal diffusion of low and high molecular mass analytes and bioparticles. It is shown that, especially in the case of CZE separation of macromolecules and particles, capillary coiling can significantly decrease the separation efficiency. For that reason the small radius coiling of the capillary column in the CZE apparatuses should be avoided.
- 11 August 1995
- Published by Elsevier in Journal of Chromatography A
- Vol. 709 (1) , 63-68
Contribution of the electroosmotic flow to peak broadening in capillary zone electrophoresis with uniform zeta potential
- 11 August 1995
- Published by Elsevier in Journal of Chromatography A
- Vol. 709 (1) , 63-68
Contribution of the electroosmotic flow to peak broadening in capillary zone electrophoresis with uniform zeta potential
- 1 August 1995
- Published by Elsevier in Journal of Chromatography A
- Vol. 709 (1) , 51-62
Electroosmosis in capillary zone electrophoresis with non-uniform zeta potential
- 1 August 1995
- Published by Elsevier in Journal of Chromatography A
- Vol. 709 (1) , 51-62
Electroosmosis in capillary zone electrophoresis with non-uniform zeta potential
- 1 January 1995
- Published by Wiley in Electrophoresis
- Vol. 16 (1) , 2027-2033
Dynamics of peak dispersion in capillary zone electrophoresis including wall adsorption: II. Exact analysis of unsteady linear adsorptive dispersion
An exact analysis of the unsteady axial dispersion of an analyte, undergoing a linear adsorption at the column wall in capillary zone electrophoresis, is presented. A system of partial differential equations – in which the radial coordinate is one of the independent variables – is taken as a model for linear wall adsorption. It is shown that the dispersion is a sum of two terms, one which depends linearly on time and whose exact form is generally known, and a nonlinear one. The most interesting result of this work is that it derives another system of differential equations, which this nonlinear term is to satisfy. It makes it possible to present a closed formula for the asymptotic value of the nonlinear term, i.e., its limit for large time. Its behavior for times close to zero is also studied.
- 1 January 1995
- Published by Wiley in Electrophoresis
- Vol. 16 (1) , 2027-2033
Dynamics of peak dispersion in capillary zone electrophoresis including wall adsorption: II. Exact analysis of unsteady linear adsorptive dispersion
An exact analysis of the unsteady axial dispersion of an analyte, undergoing a linear adsorption at the column wall in capillary zone electrophoresis, is presented. A system of partial differential equations – in which the radial coordinate is one of the independent variables – is taken as a model for linear wall adsorption. It is shown that the dispersion is a sum of two terms, one which depends linearly on time and whose exact form is generally known, and a nonlinear one. The most interesting result of this work is that it derives another system of differential equations, which this nonlinear term is to satisfy. It makes it possible to present a closed formula for the asymptotic value of the nonlinear term, i.e., its limit for large time. Its behavior for times close to zero is also studied.