Francesco Ponticelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesco Ponticelli has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
Antonio Colombo
17 shared publications- Francesco Giannini
Interventional Cardiology Unit, IRCCS Ospedale Galeazzi Sant’Ambrogio, 20157 Milan, Italy
16 shared publications - Luca Baldetti
Cardiac Intensive Care Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
10 shared publications - Guglielmo Gallone
Cardiothoracic Transplantation, Harefield Hospital, Guy's and St Thomas’ NHS Foundation Trust , London
8 shared publications - Arif Azhar Khokhar
Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
7 shared publications - Anna Palmisano
School of Medicine, Vita-Salute San Raffaele University, Milan, Italy
5 shared publications
Latest Publications
- 3 August 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (4) , 2313-2320
Impact of Coronary Sinus Reducer on Angina Symptoms in Patients With Myocardial Ischemia Without Obstructive Coronary Artery Disease
Background: Coronary sinus (CS) Reducer implantation shows favorable results in alleviating angina symptoms in patients with obstructive coronary artery disease (CAD) with non‐revascularizable lesions. Whether CS Reducer is effective also in patients without obstructive epicardial CAD remains unsettled. Aims: We sought to assess the potential benefits of the CS narrowing in patients without obstructive presenting with refractory angina. Methods: Consecutive refractory angina patients, with objective evidence of myocardial ischemia despite optimal medical therapy (OMT), who underwent CS Reducer implantation, were enrolled in an international registry. Study cohort was divided into two groups: patients with non‐obstructive CAD (< 50% narrowing in all epicardial coronary arteries or a negative intracoronary fractional flow reserve test in case of intermediate lesions), and patients with obstructive CAD. The study outcome was the improvement of the Canadian Cardiovascular Society (CCS) angina score at 12‐month follow‐up in both groups of patients. Results: Of 285 enrolled patients with successful CS Reducer implantation, 46 patients (16%) had non‐obstructive CAD and 239 patients (84%) had obstructive CAD. Baseline CCS angina score was similar in both groups (2.9 ± 0.5 vs. 2.9 ± 0.6, p = 0.884). At 12‐month follow‐up, the improvement in CCS angina score was similar in both groups (−1.4 ± 0.8 vs. −1.3 ± 0.9 vs. p = 0.67). Both groups had the same CCS angina score at 12‐month follow‐up (1.6 ± 0.8 p = 0.80). Improvement of ≥ 2 CCS classes were 41.9% and 45.1% in patients with non‐obstructive and obstructive CAD, respectively, p = 0.6746. Conclusions: In patients with refractory angina and myocardial ischemia, CS Reducer implantation improves angina symptoms in patients with myocardial ischemia with and without obstructive CAD.
- 3 August 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (4) , 2313-2320
Impact of Coronary Sinus Reducer on Angina Symptoms in Patients With Myocardial Ischemia Without Obstructive Coronary Artery Disease
Background: Coronary sinus (CS) Reducer implantation shows favorable results in alleviating angina symptoms in patients with obstructive coronary artery disease (CAD) with non‐revascularizable lesions. Whether CS Reducer is effective also in patients without obstructive epicardial CAD remains unsettled. Aims: We sought to assess the potential benefits of the CS narrowing in patients without obstructive presenting with refractory angina. Methods: Consecutive refractory angina patients, with objective evidence of myocardial ischemia despite optimal medical therapy (OMT), who underwent CS Reducer implantation, were enrolled in an international registry. Study cohort was divided into two groups: patients with non‐obstructive CAD (< 50% narrowing in all epicardial coronary arteries or a negative intracoronary fractional flow reserve test in case of intermediate lesions), and patients with obstructive CAD. The study outcome was the improvement of the Canadian Cardiovascular Society (CCS) angina score at 12‐month follow‐up in both groups of patients. Results: Of 285 enrolled patients with successful CS Reducer implantation, 46 patients (16%) had non‐obstructive CAD and 239 patients (84%) had obstructive CAD. Baseline CCS angina score was similar in both groups (2.9 ± 0.5 vs. 2.9 ± 0.6, p = 0.884). At 12‐month follow‐up, the improvement in CCS angina score was similar in both groups (−1.4 ± 0.8 vs. −1.3 ± 0.9 vs. p = 0.67). Both groups had the same CCS angina score at 12‐month follow‐up (1.6 ± 0.8 p = 0.80). Improvement of ≥ 2 CCS classes were 41.9% and 45.1% in patients with non‐obstructive and obstructive CAD, respectively, p = 0.6746. Conclusions: In patients with refractory angina and myocardial ischemia, CS Reducer implantation improves angina symptoms in patients with myocardial ischemia with and without obstructive CAD.
- 27 June 2022
- Published by Taylor & Francis in Future Cardiology
- Vol. 18 (7) , 523-537
Coronary Sinus Reducer for the Treatment of Chronic Refractory Angina Pectoris
Refractory angina represents the final stage of chronic coronary artery disease, where anginal symptoms persist despite complete epicardial coronary artery revascularization and maximally tolerated... Plain language summary Coronary Sinus Reducer device implantation is a therapeutic option for patients suffering from chest tightness, discomfort and pain (collectively named angina when of clear c...
- 27 June 2022
- Published by Taylor & Francis in Future Cardiology
- Vol. 18 (7) , 523-537
Coronary Sinus Reducer for the Treatment of Chronic Refractory Angina Pectoris
Refractory angina represents the final stage of chronic coronary artery disease, where anginal symptoms persist despite complete epicardial coronary artery revascularization and maximally tolerated... Plain language summary Coronary Sinus Reducer device implantation is a therapeutic option for patients suffering from chest tightness, discomfort and pain (collectively named angina when of clear c...
- 17 September 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (11) , E884-E889
Insights Into Coronary Sinus Reducer Non-Responders
Six mechanisms appear to explain poor response to coronary sinus reducer therapy. We hereby review these mechanisms in detail and highlight key areas that should be addressed in order to try and reduce the burden of non-responders following coronary sinus reducer implantation. Rapid Communication from Journal of Invasive Cardiology. chronic coronary disease Interventional cardiology percutaneous coronary intervention refractory angina
- 17 September 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (11) , E884-E889
Insights Into Coronary Sinus Reducer Non-Responders
Six mechanisms appear to explain poor response to coronary sinus reducer therapy. We hereby review these mechanisms in detail and highlight key areas that should be addressed in order to try and reduce the burden of non-responders following coronary sinus reducer implantation. Rapid Communication from Journal of Invasive Cardiology. chronic coronary disease Interventional cardiology percutaneous coronary intervention refractory angina
- 1 August 2021
- Published by Elsevier in International Journal of Cardiology
- Vol. 337, 29-37
Safety and efficacy of coronary sinus narrowing in chronic refractory angina: Insights from the RESOURCE study
- 1 August 2021
- Published by Elsevier in International Journal of Cardiology
- Vol. 337, 29-37
Safety and efficacy of coronary sinus narrowing in chronic refractory angina: Insights from the RESOURCE study
- 1 July 2021
- Published by Elsevier in Atherosclerosis
- Vol. 328, 136-143
Impact of clinical and subclinical coronary artery disease as assessed by coronary artery calcium in COVID-19
- 1 July 2021
- Published by Elsevier in Atherosclerosis
- Vol. 328, 136-143
Impact of clinical and subclinical coronary artery disease as assessed by coronary artery calcium in COVID-19
- Open Access
- 3 June 2021
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 25 (6) , 376-379
Diabetes and mortality in patients with COVID-19: Are we missing the link?
- 3 June 2021
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 25 (6) , 376-379
Open AccessDiabetes and mortality in patients with COVID-19: Are we missing the link?
- 14 April 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (3) , E365-E369
Coronary sinus size and ischemia improvement after reducer implantation; “one size to fit them all?”
Aim: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device.Methods: Prior to device implantation and at 4‐month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI).Results: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (P = .03) and a higher reduction in left ventricle end‐diastolic volumes.Conclusions: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non‐responsiveness.
- 14 April 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (3) , E365-E369
Coronary sinus size and ischemia improvement after reducer implantation; “one size to fit them all?”
Aim: Coronary sinus (CS) reducer implantation is associated with symptomatic relief of patients with refractory angina. However, 15% to 30% of the patients do not respond to this treatment. Aim if this study was to evaluate the effect of CS size in the effectiveness of the device.Methods: Prior to device implantation and at 4‐month resting ventricular function was assessed by stress cardiac magnetic resonance. Ischemia was assessed by the myocardial perfusion reserve index (MPRI).Results: Fifteen patients (66 ± 10 years) underwent successful CS Reducer implantation, with improvements in angina class and exercise tolerance. Patients with a smaller CS size (P = .03) and a higher reduction in left ventricle end‐diastolic volumes.Conclusions: Greater benefits, in terms of ischemia improvement, after CS Reducer implantation were seen in patients with smaller CS sizes, suggesting a potential mechanism underlying the observed rates of reducer non‐responsiveness.
- 14 February 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (3) , 595-604
Computed tomography analysis of coronary ostia location following valve‐in‐valve transcatheter aortic valve replacement with the ACURATE neo valve: Implications for coronary access
Background: Valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR) is an emerging alternative to re‐do surgery. However, the challenge of coronary access (CA) following ViV‐TAVR is a potential limitation as TAVR expands to younger lower‐risk populations.Objectives: Using post‐implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV‐TAVR with the ACURATE neo valve.Methods: Post‐implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter‐to‐coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated.Results: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub‐classification of these ostia revealed a large (>6 mm), moderate (4–6 mm), and small (p = .5, 95%CI 3.8–7.5).Conclusions: CA following ACURATE neo implantation for ViV‐TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.
- 14 February 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (3) , 595-604
Computed tomography analysis of coronary ostia location following valve‐in‐valve transcatheter aortic valve replacement with the ACURATE neo valve: Implications for coronary access
Background: Valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR) is an emerging alternative to re‐do surgery. However, the challenge of coronary access (CA) following ViV‐TAVR is a potential limitation as TAVR expands to younger lower‐risk populations.Objectives: Using post‐implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV‐TAVR with the ACURATE neo valve.Methods: Post‐implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter‐to‐coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated.Results: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub‐classification of these ostia revealed a large (>6 mm), moderate (4–6 mm), and small (p = .5, 95%CI 3.8–7.5).Conclusions: CA following ACURATE neo implantation for ViV‐TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.
- 17 November 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (7) , E900-E910
Iatrogenic aorta‐coronary dissection: Case report and systematic review
Objectives and Background: Iatrogenic aorto‐coronary dissection (ICD) is one of the most feared complications of interventional cardiology. Although rare, it is characterized by anterograde coronary ischemia and a concomitant aortic dissection, with potentially fatal consequences.Methods: We present an example case of IACD and an accurate case‐series review of the literature including 125 published cases.Results: There were no significant predisposing factors and the IACD occurred equally in elective and urgent procedures. A significant number of IACDs were associated with CTO procedures. The factors associated with a worse outcome were hemodynamic instability, the presence of anterograde ischemia, and the extent of dissection according to the Dunning classification. Bail‐out stenting was the most used strategy and its failure was associated with mortality.Conclusion: The main features of IACD are anterograde ischemia, retrograde dissection, and hemodynamic instability, each of them should be addressed with no time delay, possibly with bailout stenting, the most employed exit‐strategy. According to our proposed algorithm, a shock team approach is required to coordinate the interdisciplinary skills and enabled patients to receive the best treatment.
- 17 November 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (7) , E900-E910
Iatrogenic aorta‐coronary dissection: Case report and systematic review
Objectives and Background: Iatrogenic aorto‐coronary dissection (ICD) is one of the most feared complications of interventional cardiology. Although rare, it is characterized by anterograde coronary ischemia and a concomitant aortic dissection, with potentially fatal consequences.Methods: We present an example case of IACD and an accurate case‐series review of the literature including 125 published cases.Results: There were no significant predisposing factors and the IACD occurred equally in elective and urgent procedures. A significant number of IACDs were associated with CTO procedures. The factors associated with a worse outcome were hemodynamic instability, the presence of anterograde ischemia, and the extent of dissection according to the Dunning classification. Bail‐out stenting was the most used strategy and its failure was associated with mortality.Conclusion: The main features of IACD are anterograde ischemia, retrograde dissection, and hemodynamic instability, each of them should be addressed with no time delay, possibly with bailout stenting, the most employed exit‐strategy. According to our proposed algorithm, a shock team approach is required to coordinate the interdisciplinary skills and enabled patients to receive the best treatment.
- 31 August 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (5) , 950-954
Transcatheter aortic valve implantation for severe pure aortic regurgitation due to active aortitis
Aortitis is an uncommon systemic inflammatory disease affecting the aorta and its main branches. Severe aortic regurgitation (AR) represents a fearsome complication of aortitis and is associated with an increased mortality rate. Surgical aortic valve replacement represents the only treatment choice for these patients. However, it is associated with a higher risk of medium to long‐term complications such as prosthetic valve detachment. This is the first reported case where severe AR secondary to aortitis was managed with transcatheter aortic valve implantation (TAVI). TAVI was safe and effective in this clinical setting and may be considered a viable alternative to high‐risk surgery in these complex patients.
- 31 August 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (5) , 950-954
Transcatheter aortic valve implantation for severe pure aortic regurgitation due to active aortitis
Aortitis is an uncommon systemic inflammatory disease affecting the aorta and its main branches. Severe aortic regurgitation (AR) represents a fearsome complication of aortitis and is associated with an increased mortality rate. Surgical aortic valve replacement represents the only treatment choice for these patients. However, it is associated with a higher risk of medium to long‐term complications such as prosthetic valve detachment. This is the first reported case where severe AR secondary to aortitis was managed with transcatheter aortic valve implantation (TAVI). TAVI was safe and effective in this clinical setting and may be considered a viable alternative to high‐risk surgery in these complex patients.