Inas A. Yassine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Inas A. Yassine has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Ayman Eldeib
Southern New Hampshire University
2 shared publications - Merna Bibars
Cairo University
2 shared publications - Muhammad Ali Rushdi
Department of Biomedical Engineering and Systems, Faculty of Engineering, Cairo University, Cairo University St, Giza, 12613, Egypt.
2 shared publications - Mustafa Elattar
Medical Imaging and Image Processing Research Group, Center for Informatics Science, Nile University, Giza, Egypt
2 shared publications - Peter E. Salah
Cairo University
2 shared publications Abd ElSalam kh.Ezzat
1 shared publication
Latest Publications
- 1 August 2024
- Published by Avestia Publishing
Stage U-Net Framework: Streamlining MRI Reconstruction From Under-sampled K-Space
- 1 August 2024
- Published by Avestia Publishing
Stage U-Net Framework: Streamlining MRI Reconstruction From Under-sampled K-Space
- 2 December 2023
- Published by Springer Nature
- p. 96-110
Cross-Modality Deep Transfer Learning: Application to Liver Segmentation in CT and MRI
- 2 December 2023
- Published by Springer Nature
- p. 96-110
Cross-Modality Deep Transfer Learning: Application to Liver Segmentation in CT and MRI
- Open Access
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 24431-24447
Dynamic Construction of Outlier Detector Ensembles With Bisecting K-Means Clustering
Outlier detection (OD) is a key problem, for which numerous solutions have been proposed. To deal with the difficulties associated with outlier detection across various domains and data characteristics, ensembles of outlier detectors have recently been employed to improve the performance of individual outlier detectors. In this paper, we follow an ensemble outlier detection approach in which good outlier detectors are selected through an enhanced clustering-based dynamic selection (CBDS) method. In this method, a bisecting K-means clustering algorithm is employed to partition the input data into clusters where every cluster defines a local region of competence. Among the initial pool of detectors, the outputs of the detectors with the most competent local performance were combined through four possible schemes to produce the final OD results. Experimental evaluation and comparison of our method were carried out against four variants of locally selective combination in parallel (LSCP) outlier ensembles. The CBDS-based schemes compare well with the LSCP-based ones on 16 public benchmark datasets and incur considerably lower computational costs. The CBDS method consistently achieved superior average scores of the area under the curve (AUC) of the receiver operating characteristic (ROC), and particularly outperformed the LSCP method on nine of the 16 datasets in terms of the AUC score. In addition, while the CBDS and LSCP methods have similar computational costs on small datasets, the CBDS method achieves significant time savings compared with the LSCP method on large datasets.
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 24431-24447
Open AccessDynamic Construction of Outlier Detector Ensembles With Bisecting K-Means Clustering
Outlier detection (OD) is a key problem, for which numerous solutions have been proposed. To deal with the difficulties associated with outlier detection across various domains and data characteristics, ensembles of outlier detectors have recently been employed to improve the performance of individual outlier detectors. In this paper, we follow an ensemble outlier detection approach in which good outlier detectors are selected through an enhanced clustering-based dynamic selection (CBDS) method. In this method, a bisecting K-means clustering algorithm is employed to partition the input data into clusters where every cluster defines a local region of competence. Among the initial pool of detectors, the outputs of the detectors with the most competent local performance were combined through four possible schemes to produce the final OD results. Experimental evaluation and comparison of our method were carried out against four variants of locally selective combination in parallel (LSCP) outlier ensembles. The CBDS-based schemes compare well with the LSCP-based ones on 16 public benchmark datasets and incur considerably lower computational costs. The CBDS method consistently achieved superior average scores of the area under the curve (AUC) of the receiver operating characteristic (ROC), and particularly outperformed the LSCP method on nine of the 16 datasets in terms of the AUC score. In addition, while the CBDS and LSCP methods have similar computational costs on small datasets, the CBDS method achieves significant time savings compared with the LSCP method on large datasets.
- Open Access
- 24 May 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (5) , e0265300
Feature and decision-level fusion for schizophrenia detection based on resting-state fMRI data
Mental disorders, especially schizophrenia, still pose a great challenge for diagnosis in early stages. Recently, computer-aided diagnosis techniques based on resting-state functional magnetic resonance imaging (Rs-fMRI) have been developed to tackle this challenge. In this work, we investigate different decision-level and feature-level fusion schemes for discriminating between schizophrenic and normal subjects. Four types of fMRI features are investigated, namely the regional homogeneity, voxel-mirrored homotopic connectivity, fractional amplitude of low-frequency fluctuations and amplitude of low-frequency fluctuations. Data denoising and preprocessing were first applied, followed by the feature extraction module. Four different feature selection algorithms were applied, and the best discriminative features were selected using the algorithm of feature selection via concave minimization (FSV). Support vector machine classifiers were trained and tested on the COBRE dataset formed of 70 schizophrenic subjects and 70 healthy subjects. The decision-level fusion method outperformed the single-feature-type approaches and achieved a 97.85% accuracy, a 98.33% sensitivity, a 96.83% specificity. Moreover, feature-fusion scheme resulted in a 98.57% accuracy, a 99.71% sensitivity, a 97.66% specificity, and an area under the ROC curve of 0.9984. In general, decision-level and feature-level fusion schemes boosted the performance of schizophrenia detectors based on fMRI features.
- 24 May 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (5) , e0265300
Open AccessFeature and decision-level fusion for schizophrenia detection based on resting-state fMRI data
Mental disorders, especially schizophrenia, still pose a great challenge for diagnosis in early stages. Recently, computer-aided diagnosis techniques based on resting-state functional magnetic resonance imaging (Rs-fMRI) have been developed to tackle this challenge. In this work, we investigate different decision-level and feature-level fusion schemes for discriminating between schizophrenic and normal subjects. Four types of fMRI features are investigated, namely the regional homogeneity, voxel-mirrored homotopic connectivity, fractional amplitude of low-frequency fluctuations and amplitude of low-frequency fluctuations. Data denoising and preprocessing were first applied, followed by the feature extraction module. Four different feature selection algorithms were applied, and the best discriminative features were selected using the algorithm of feature selection via concave minimization (FSV). Support vector machine classifiers were trained and tested on the COBRE dataset formed of 70 schizophrenic subjects and 70 healthy subjects. The decision-level fusion method outperformed the single-feature-type approaches and achieved a 97.85% accuracy, a 98.33% sensitivity, a 96.83% specificity. Moreover, feature-fusion scheme resulted in a 98.57% accuracy, a 99.71% sensitivity, a 97.66% specificity, and an area under the ROC curve of 0.9984. In general, decision-level and feature-level fusion schemes boosted the performance of schizophrenia detectors based on fMRI features.
- Open Access
- 12 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0264710
Alzheimer disease stages identification based on correlation transfer function system using resting-state functional magnetic resonance imaging
Alzheimer’s disease (AD) affects the quality of life as it causes; memory loss, difficulty in thinking, learning, and performing familiar tasks. Resting-state functional magnetic resonance imaging (rs-fMRI) has been widely used to investigate and analyze different brain regions for AD identification. This study investigates the effectiveness of using correlated transfer function (CorrTF) as a new biomarker to extract the essential features from rs-fMRI, along with support vector machine (SVM) ordered hierarchically, in order to distinguish between the different AD stages. Additionally, we explored the regions, showing significant changes based on the CorrTF extracted features’ strength among different AD stages. First, the process was initialized by applying the preprocessing on rs-fMRI data samples to reduce noise and retain the essential information. Then, the automated anatomical labeling (AAL) atlas was employed to divide the brain into 116 regions, where the intensity time series was calculated, and the CorrTF features were extracted for each region. The proposed framework employed the SVM classifier in two different methodologies, hierarchical and flat multi-classification schemes, to differentiate between the different AD stages for early detection purposes. The ADNI rs-fMRI dataset, employed in this study, consists of 167, 102, 129, and 114 normal, early, late mild cognitive impairment (MCI), and AD subjects, respectively. The proposed schemes achieved an average accuracy of 98.2% and 95.5% for hierarchical and flat multi-classification tasks, respectively, calculated using ten folds cross-validation. Therefore, CorrTF is considered a promising biomarker for AD early-stage identification. Moreover, the significant changes in the strengths of CorrTF connections among the different AD stages can help us identify and explore the affected brain regions and their latent associations during the progression of AD.
- 12 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0264710
Open AccessAlzheimer disease stages identification based on correlation transfer function system using resting-state functional magnetic resonance imaging
Alzheimer’s disease (AD) affects the quality of life as it causes; memory loss, difficulty in thinking, learning, and performing familiar tasks. Resting-state functional magnetic resonance imaging (rs-fMRI) has been widely used to investigate and analyze different brain regions for AD identification. This study investigates the effectiveness of using correlated transfer function (CorrTF) as a new biomarker to extract the essential features from rs-fMRI, along with support vector machine (SVM) ordered hierarchically, in order to distinguish between the different AD stages. Additionally, we explored the regions, showing significant changes based on the CorrTF extracted features’ strength among different AD stages. First, the process was initialized by applying the preprocessing on rs-fMRI data samples to reduce noise and retain the essential information. Then, the automated anatomical labeling (AAL) atlas was employed to divide the brain into 116 regions, where the intensity time series was calculated, and the CorrTF features were extracted for each region. The proposed framework employed the SVM classifier in two different methodologies, hierarchical and flat multi-classification schemes, to differentiate between the different AD stages for early detection purposes. The ADNI rs-fMRI dataset, employed in this study, consists of 167, 102, 129, and 114 normal, early, late mild cognitive impairment (MCI), and AD subjects, respectively. The proposed schemes achieved an average accuracy of 98.2% and 95.5% for hierarchical and flat multi-classification tasks, respectively, calculated using ten folds cross-validation. Therefore, CorrTF is considered a promising biomarker for AD early-stage identification. Moreover, the significant changes in the strengths of CorrTF connections among the different AD stages can help us identify and explore the affected brain regions and their latent associations during the progression of AD.
- Open Access
- 24 March 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (3) , e0230409
Alzheimer’s disease diagnosis from diffusion tensor images using convolutional neural networks
Machine learning algorithms are currently being implemented in an escalating manner to classify and/or predict the onset of some neurodegenerative diseases; including Alzheimer’s Disease (AD); this could be attributed to the fact of the abundance of data and powerful computers. The objective of this work was to deliver a robust classification system for AD and Mild Cognitive Impairment (MCI) against healthy controls (HC) in a low-cost network in terms of shallow architecture and processing. In this study, the dataset included was downloaded from the Alzheimer’s disease neuroimaging initiative (ADNI). The classification methodology implemented was the convolutional neural network (CNN), where the diffusion maps, and gray-matter (GM) volumes were the input images. The number of scans included was 185, 106, and 115 for HC, MCI and AD respectively. Ten-fold cross-validation scheme was adopted and the stacked mean diffusivity (MD) and GM volume produced an AUC of 0.94 and 0.84, an accuracy of 93.5% and 79.6%, a sensitivity of 92.5% and 62.7%, and a specificity of 93.9% and 89% for AD/HC and MCI/HC classification respectively. This work elucidates the impact of incorporating data from different imaging modalities; i.e. structural Magnetic Resonance Imaging (MRI) and Diffusion Tensor Imaging (DTI), where deep learning was employed for the aim of classification. To the best of our knowledge, this is the first study assessing the impact of having more than one scan per subject and propose the proper maneuver to confirm the robustness of the system. The results were competitive among the existing literature, which paves the way for improving medications that could slow down the progress of the AD or prevent it.
- 24 March 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (3) , e0230409
Open AccessAlzheimer’s disease diagnosis from diffusion tensor images using convolutional neural networks
Machine learning algorithms are currently being implemented in an escalating manner to classify and/or predict the onset of some neurodegenerative diseases; including Alzheimer’s Disease (AD); this could be attributed to the fact of the abundance of data and powerful computers. The objective of this work was to deliver a robust classification system for AD and Mild Cognitive Impairment (MCI) against healthy controls (HC) in a low-cost network in terms of shallow architecture and processing. In this study, the dataset included was downloaded from the Alzheimer’s disease neuroimaging initiative (ADNI). The classification methodology implemented was the convolutional neural network (CNN), where the diffusion maps, and gray-matter (GM) volumes were the input images. The number of scans included was 185, 106, and 115 for HC, MCI and AD respectively. Ten-fold cross-validation scheme was adopted and the stacked mean diffusivity (MD) and GM volume produced an AUC of 0.94 and 0.84, an accuracy of 93.5% and 79.6%, a sensitivity of 92.5% and 62.7%, and a specificity of 93.9% and 89% for AD/HC and MCI/HC classification respectively. This work elucidates the impact of incorporating data from different imaging modalities; i.e. structural Magnetic Resonance Imaging (MRI) and Diffusion Tensor Imaging (DTI), where deep learning was employed for the aim of classification. To the best of our knowledge, this is the first study assessing the impact of having more than one scan per subject and propose the proper maneuver to confirm the robustness of the system. The results were competitive among the existing literature, which paves the way for improving medications that could slow down the progress of the AD or prevent it.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (19457928) , 88-91
Spectral correlation analysis for microcalcification detection in digital mammogram images
Breast cancer has been threatening lives of women around the world. Thus, Computer Aided Diagnosis (CAD) systems play an important role in early detection of breast cancer. In this study, we propose a CAD system based on cyclostationary signal analysis for microcalcifications detection. Spectral correlation is estimated for regions of interests (ROIs) after conversion to 1D vector. The proposed algorithm utilizes simple statistical features calculation for the raw spectral data followed by student-t test for evaluation and reduction of the generated set of features. Support Vector Machines (SVM) with linear kernel was employed for the classification task. The experimental results showed that the proposed approach is superior compared to several state of the art methods. This approach was tested using digital database for screening mammogram (DDSM) and it achieved sensitivity, specificity and accuracy of 95.88%, 93.10% and 94.44% respectively.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 13 (19457928) , 88-91
Spectral correlation analysis for microcalcification detection in digital mammogram images
Breast cancer has been threatening lives of women around the world. Thus, Computer Aided Diagnosis (CAD) systems play an important role in early detection of breast cancer. In this study, we propose a CAD system based on cyclostationary signal analysis for microcalcifications detection. Spectral correlation is estimated for regions of interests (ROIs) after conversion to 1D vector. The proposed algorithm utilizes simple statistical features calculation for the raw spectral data followed by student-t test for evaluation and reduction of the generated set of features. Support Vector Machines (SVM) with linear kernel was employed for the classification task. The experimental results showed that the proposed approach is superior compared to several state of the art methods. This approach was tested using digital database for screening mammogram (DDSM) and it achieved sensitivity, specificity and accuracy of 95.88%, 93.10% and 94.44% respectively.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21566097,p. 125-128
Cardiac MRI view classification using autoencoder
The growing interest of using cardiac Magnetic Resonance Imaging (MRI) to assess the heart function and structure results in creating huge cardiac image databases. Due to the lack of standard meta-data description of the images, content-based classification of the cardiac images is essential to manage such databases. In particular, cardiac view classification is becoming an important stage for medical image analysis; efficient content-based retrieval as well as CAD systems. The major challenge in such classification lies in the large variability in image appearance caused by variation of patient-specific geometry, heart deformations, and disease conditions. In this work, a fully automated view classification of cardiac MRI images is presented. The method uses the autoencoder system for automatic feature extraction from a training dataset. A softmax classifier is used to determine the view from the selected features. Several autoencoder systems have been investigated in order to select the most suitable architecture for the problem. The results show that the proposed method outperforms current systems with orientation classification accuracy for Cine, SENC and Tagged MRI Imaging sequences was 96.7%, 91.98%, 100% respectively.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21566097,p. 125-128
Cardiac MRI view classification using autoencoder
The growing interest of using cardiac Magnetic Resonance Imaging (MRI) to assess the heart function and structure results in creating huge cardiac image databases. Due to the lack of standard meta-data description of the images, content-based classification of the cardiac images is essential to manage such databases. In particular, cardiac view classification is becoming an important stage for medical image analysis; efficient content-based retrieval as well as CAD systems. The major challenge in such classification lies in the large variability in image appearance caused by variation of patient-specific geometry, heart deformations, and disease conditions. In this work, a fully automated view classification of cardiac MRI images is presented. The method uses the autoencoder system for automatic feature extraction from a training dataset. A softmax classifier is used to determine the view from the selected features. Several autoencoder systems have been investigated in order to select the most suitable architecture for the problem. The results show that the proposed method outperforms current systems with orientation classification accuracy for Cine, SENC and Tagged MRI Imaging sequences was 96.7%, 91.98%, 100% respectively.
- Open Access
- 1 October 2012
- Published by Scientific and Academic Publishing in Advances in Computing
- Vol. 2 (5) , 66-75
A New Numerical Model to Analyze Stress Distribution of TMJ Disc from 2-D MRI Scans
From the anatomical and biomechanical points of view, temporomandibular joint (TMJ) is sophisticated bicondylar articulatory complex with great demand on neuromuscular control with a frequency of motion indicated up to 2000 periods per day. This makes the TMJ one of the most frequently exerted joints of the human body and in conjunction with individual uniqueness of this joint places high demand on its design and reliability. Experimental studies concerning the distribution of the loads in the TMJ have been performed on animal models. Numerical modeling provides more understanding of joint physiology and pathogenesis of the joint diseases. Magnetic resonance imaging (MRI) has replaced computed tomography (CT) and arthrography as the primary modality in the evaluation of the TMJ. At this study a new numerical method are used to build 3-D model of TMJ from 2-D MRI scans and applied some stress-strain analysis to validate this model for different normal and abnormal patients. These models are based on multi-object reconstruction technique and tetrahedral elements building
- 1 October 2012
- Published by Scientific and Academic Publishing in Advances in Computing
- Vol. 2 (5) , 66-75
Open AccessA New Numerical Model to Analyze Stress Distribution of TMJ Disc from 2-D MRI Scans
From the anatomical and biomechanical points of view, temporomandibular joint (TMJ) is sophisticated bicondylar articulatory complex with great demand on neuromuscular control with a frequency of motion indicated up to 2000 periods per day. This makes the TMJ one of the most frequently exerted joints of the human body and in conjunction with individual uniqueness of this joint places high demand on its design and reliability. Experimental studies concerning the distribution of the loads in the TMJ have been performed on animal models. Numerical modeling provides more understanding of joint physiology and pathogenesis of the joint diseases. Magnetic resonance imaging (MRI) has replaced computed tomography (CT) and arthrography as the primary modality in the evaluation of the TMJ. At this study a new numerical method are used to build 3-D model of TMJ from 2-D MRI scans and applied some stress-strain analysis to validate this model for different normal and abnormal patients. These models are based on multi-object reconstruction technique and tetrahedral elements building