Aibek Niyetkaliyev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aibek Niyetkaliyev has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Prashant Kumar Jamwal
Department of Electrical and Computer Engineering, Nazarbayev University, Astana, Kazakhstan
4 shared publications - Aiman Ozhikenova
Satbayev University
3 shared publications - Almas Shintemirov
Nazarbayev University, Astana, Kazakhstan
3 shared publications - Gursel Alici
University of Wollongong
3 shared publications - Lashin Bazarbay
Satbayev University
3 shared publications - Zhadyra Alimbayeva
Department of Robotics and technical means of automation, Satbayev University, Almaty, Kazakhstan, Kazakhstan
3 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 13, e94916
State-of-the-Art Knee Exoskeleton for Gait Assistance and Rehabilitation: Systematic Review
Background: Knee exoskeletons represent a significant advancement in wearable robotic technology, developed to enhance gait assistance and facilitate rehabilitation processes. These devices are increasingly used in clinical and research environments worldwide. Nonetheless, the existing empirical evidence supporting their biomechanical and functional outcomes lacks both breadth and clarity. Further investigation is essential to elucidate the specific effects of knee exoskeletons on gait dynamics and rehabilitation efficacy. Objective: This study aims to systematically review the clinical and biomechanical evidence on knee exoskeletons used for gait assistance and rehabilitation. Methods: A systematic search of databases—PubMed, Web of Science, IEEE Xplore, and Scopus—was conducted to identify eligible studies published between January 2015 and March 2025. Studies were included if they investigated knee exoskeleton systems in human participants for gait assistance and rehabilitation. Randomized controlled trials, observational studies, and experimental investigations were eligible. Exclusion criteria were multijoint exoskeletons, nonhuman studies, and simulation-based analyses. Two reviewers independently extracted study characteristics, participant demographics, device features, intervention protocols, and clinical and biomechanical outcomes. Risk of bias was assessed using RoB-2 (Cochrane Risk of Bias 2) for randomized controlled trials and ROBINS-I (Risk of Bias in Nonrandomized Studies of Interventions) for nonrandomized studies. Results: Thirty-two studies met the inclusion criteria. Most investigations involved healthy adults in feasibility or pilot settings, while a smaller subset included individuals with stroke, spinal cord injury, or orthopedic conditions or pediatric movement disorders. Across studies, knee exoskeletons demonstrated short-term improvements in spatiotemporal gait parameters, including increased gait speed and step length, improved knee joint kinematics, and reductions in muscular effort or metabolic demand. However, substantial heterogeneity in device design, outcome metrics, and intervention duration limits comparability across studies. Sample sizes were typically small, and follow-up outcomes were rarely reported, restricting the interpretation of the long-term clinical efficacy of these devices. Conclusions: Knee exoskeletons demonstrate promising short-term functional and biomechanical benefits and are increasingly feasible within structured rehabilitation settings. While current evidence is limited by small sample sizes and brief follow-up periods, emerging data suggest potential for enhancing task-specific gait training. Larger, well-designed trials are needed to determine sustained clinical impact and integration into routine rehabilitation practice.
- 4 August 2026
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 13, e94916
Open AccessState-of-the-Art Knee Exoskeleton for Gait Assistance and Rehabilitation: Systematic Review
Background: Knee exoskeletons represent a significant advancement in wearable robotic technology, developed to enhance gait assistance and facilitate rehabilitation processes. These devices are increasingly used in clinical and research environments worldwide. Nonetheless, the existing empirical evidence supporting their biomechanical and functional outcomes lacks both breadth and clarity. Further investigation is essential to elucidate the specific effects of knee exoskeletons on gait dynamics and rehabilitation efficacy. Objective: This study aims to systematically review the clinical and biomechanical evidence on knee exoskeletons used for gait assistance and rehabilitation. Methods: A systematic search of databases—PubMed, Web of Science, IEEE Xplore, and Scopus—was conducted to identify eligible studies published between January 2015 and March 2025. Studies were included if they investigated knee exoskeleton systems in human participants for gait assistance and rehabilitation. Randomized controlled trials, observational studies, and experimental investigations were eligible. Exclusion criteria were multijoint exoskeletons, nonhuman studies, and simulation-based analyses. Two reviewers independently extracted study characteristics, participant demographics, device features, intervention protocols, and clinical and biomechanical outcomes. Risk of bias was assessed using RoB-2 (Cochrane Risk of Bias 2) for randomized controlled trials and ROBINS-I (Risk of Bias in Nonrandomized Studies of Interventions) for nonrandomized studies. Results: Thirty-two studies met the inclusion criteria. Most investigations involved healthy adults in feasibility or pilot settings, while a smaller subset included individuals with stroke, spinal cord injury, or orthopedic conditions or pediatric movement disorders. Across studies, knee exoskeletons demonstrated short-term improvements in spatiotemporal gait parameters, including increased gait speed and step length, improved knee joint kinematics, and reductions in muscular effort or metabolic demand. However, substantial heterogeneity in device design, outcome metrics, and intervention duration limits comparability across studies. Sample sizes were typically small, and follow-up outcomes were rarely reported, restricting the interpretation of the long-term clinical efficacy of these devices. Conclusions: Knee exoskeletons demonstrate promising short-term functional and biomechanical benefits and are increasingly feasible within structured rehabilitation settings. While current evidence is limited by small sample sizes and brief follow-up periods, emerging data suggest potential for enhancing task-specific gait training. Larger, well-designed trials are needed to determine sustained clinical impact and integration into routine rehabilitation practice.
- Open Access
- 15 July 2026
- Published by Elsevier in SSRN Electronic Journal
A Geometry-Guided Sizing and Static Force Modeling Protocol for Compact Antagonistic Cable-Driven Joints
This article outlines a customizable geometric optimization, force modeling, and experimental evaluation of a compact, 3D-printed antagonistic cable-driven robotic elbow joint intended for upper-limb medical rehabilitation. Cable-driven parallel manipulators (CDPRs) offer significant advantages for wearables by minimizing distal mass and inertia, though they require meticulous tension and workspace management to ensure cables remain taut without structural or cable-link collisions. The proposed single-degree-of-freedom joint uses a biologically inspired dual-cable architecture alongside a unique Bowden cable sheath routing mechanism to mitigate cable interference and expand the operational workspace. Analytical models for inverse kinematics and static equilibrium were formulated to define optimal geometric parameters, establishing that a base-to-platform distance of h = 240 mm with a platform diameter D = 80 mm balances a 135° flexion range of motion with efficient actuator demands. Implementing a hardware-in-the-loop control loop via MATLAB/Simulink, the architecture combines position and force-bounded strategy. Experimental validations on the physical prototype demonstrate excellent agreement between theoretical predictions and empirical measurements for both cable displacements and tension control.
- 15 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Geometry-Guided Sizing and Static Force Modeling Protocol for Compact Antagonistic Cable-Driven Joints
This article outlines a customizable geometric optimization, force modeling, and experimental evaluation of a compact, 3D-printed antagonistic cable-driven robotic elbow joint intended for upper-limb medical rehabilitation. Cable-driven parallel manipulators (CDPRs) offer significant advantages for wearables by minimizing distal mass and inertia, though they require meticulous tension and workspace management to ensure cables remain taut without structural or cable-link collisions. The proposed single-degree-of-freedom joint uses a biologically inspired dual-cable architecture alongside a unique Bowden cable sheath routing mechanism to mitigate cable interference and expand the operational workspace. Analytical models for inverse kinematics and static equilibrium were formulated to define optimal geometric parameters, establishing that a base-to-platform distance of h = 240 mm with a platform diameter D = 80 mm balances a 135° flexion range of motion with efficient actuator demands. Implementing a hardware-in-the-loop control loop via MATLAB/Simulink, the architecture combines position and force-bounded strategy. Experimental validations on the physical prototype demonstrate excellent agreement between theoretical predictions and empirical measurements for both cable displacements and tension control.
- Open Access
- 7 July 2026
- Published by Elsevier in SSRN Electronic Journal
ROI-SSIM Guided Framework for 3D Knee MRI Reconstruction under Artifact Degradation
Magnetic resonance imaging (MRI) reconstruction is highly sensitive to undersampling and acquisition artifacts. Although deep learning-based approaches have significantly improved reconstruction quality, they are typically optimized using global fidelity metrics that may not fully reflect reconstruction quality within clinically important structures such as the anterior cruciate ligament (ACL), meniscus, and articular cartilage. This study proposes aa Region-of-Interest aware MRI reconstruction framework based on a Vision Transformer autoencoder (ViT-AE) guided by a ROI Structural Similarity (ROI-SSIM) loss. The method leverages fastMRI+ bounding-box annotations and incorporates a hybrid artifact simulation framework spanning k-space and image-domain degradations. Experiments on the fastMRI knee single-coil validation set (PD contrast, R=4) show that the proposed ViT-AE achieves competitive reconstruction fidelity to established baselines (SSIM 0.819, Peak Signal-to-Noise Ratio (PSNR) ), while ROI-SSIM supervision improves preservation of relevant anatomy. Under mixed artifact conditions, region-specific structural similarity decreased by only , compared with a decrease in global SSIM. These results indicate that region-aware optimization improves robustness and anatomical preservation under realistic acquisition conditions.Overall, the method presented in this paper:• Introduces ROI-SSIM supervision for region-aware MRI reconstruction.• Develops a hybrid artifact simulation framework spanning k-space and image-domain degradations.• Demonstrates improved anatomical preservation under artifact conditions.
- 7 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessROI-SSIM Guided Framework for 3D Knee MRI Reconstruction under Artifact Degradation
Magnetic resonance imaging (MRI) reconstruction is highly sensitive to undersampling and acquisition artifacts. Although deep learning-based approaches have significantly improved reconstruction quality, they are typically optimized using global fidelity metrics that may not fully reflect reconstruction quality within clinically important structures such as the anterior cruciate ligament (ACL), meniscus, and articular cartilage. This study proposes aa Region-of-Interest aware MRI reconstruction framework based on a Vision Transformer autoencoder (ViT-AE) guided by a ROI Structural Similarity (ROI-SSIM) loss. The method leverages fastMRI+ bounding-box annotations and incorporates a hybrid artifact simulation framework spanning k-space and image-domain degradations. Experiments on the fastMRI knee single-coil validation set (PD contrast, R=4) show that the proposed ViT-AE achieves competitive reconstruction fidelity to established baselines (SSIM 0.819, Peak Signal-to-Noise Ratio (PSNR) ), while ROI-SSIM supervision improves preservation of relevant anatomy. Under mixed artifact conditions, region-specific structural similarity decreased by only , compared with a decrease in global SSIM. These results indicate that region-aware optimization improves robustness and anatomical preservation under realistic acquisition conditions.Overall, the method presented in this paper:• Introduces ROI-SSIM supervision for region-aware MRI reconstruction.• Develops a hybrid artifact simulation framework spanning k-space and image-domain degradations.• Demonstrates improved anatomical preservation under artifact conditions.
- Open Access
- 10 March 2026
- Published by JMIR Publications Inc. in JMIR Preprints
State-of-the-art Knee Exoskeleton for gait assistance and rehabilitation: Systematic Review (Preprint)
BACKGROUND Knee exoskeletons represent a significant advancement in wearable robotic technology, developed to enhance gait assistance and facilitate rehabilitation processes. These devices are increasingly employed in clinical and research environments worldwide. Nonetheless, the existing empirical evidence that substantiates their biomechanical and functional outcomes lacks comprehensive breadth and clarity. Further investigation is essential to elucidate the specific effects of knee exoskeletons on gait dynamics and rehabilitation efficacy. OBJECTIVE To systematically review the clinical and biomechanical evidence on knee exoskeletons used for gait assistance and rehabilitation. METHODS A systematic search of databases including PubMed, Web of Science, IEEE Xplore, and Scopus was conducted to identify eligible studies published between January 2015 and March 2025. Studies were included if they investigated knee exoskeleton systems in human participants for gait assistance and rehabilitation. Randomized Controlled Trials, Observational studies, and Experimental investigations were eligible. Exclusion criteria were multi-joint exoskeletons, non-human studies, and simulation-based analyses. Two reviewers independently extracted study characteristics, participant demographics, device features, intervention protocols, and clinical and biomechanical outcomes. Risk of bias was assessed using RoB-2 for randomized controlled trials and ROBINS-I for non-randomized studies. RESULTS Thirty-two studies met the inclusion criteria. Most investigations involved healthy adults in feasibility or pilot settings, while a smaller subset included individuals with stroke, spinal cord injury, or orthopedic conditions or pediatric movement disorders. Across studies, knee exoskeletons demonstrated short-term improvements in spatiotemporal gait parameters, knee joint kinematics, and metabolic efficiency. However, substantial heterogeneity in device design, outcome metrics, and intervention duration leads to limited comparability across studies. Sample sizes were typically small, and follow-up outcomes were rarely reported, restricting the interpretation of the long-term clinical efficacy of these devices. CONCLUSIONS Knee exoskeletons demonstrate promising short-term functional and biomechanical benefits and are increasingly feasible within structured rehabilitation settings. While current evidence is limited by small sample sizes and brief follow-up, emerging data suggests the potential to enhance task-specific gait training. Larger, well-designed trials are needed to determine sustained clinical impact and integration into routine rehabilitation practice. CLINICALTRIAL This systematic review was registered in PROSPERO (CRD420261285256)
- 10 March 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessState-of-the-art Knee Exoskeleton for gait assistance and rehabilitation: Systematic Review (Preprint)
BACKGROUND Knee exoskeletons represent a significant advancement in wearable robotic technology, developed to enhance gait assistance and facilitate rehabilitation processes. These devices are increasingly employed in clinical and research environments worldwide. Nonetheless, the existing empirical evidence that substantiates their biomechanical and functional outcomes lacks comprehensive breadth and clarity. Further investigation is essential to elucidate the specific effects of knee exoskeletons on gait dynamics and rehabilitation efficacy. OBJECTIVE To systematically review the clinical and biomechanical evidence on knee exoskeletons used for gait assistance and rehabilitation. METHODS A systematic search of databases including PubMed, Web of Science, IEEE Xplore, and Scopus was conducted to identify eligible studies published between January 2015 and March 2025. Studies were included if they investigated knee exoskeleton systems in human participants for gait assistance and rehabilitation. Randomized Controlled Trials, Observational studies, and Experimental investigations were eligible. Exclusion criteria were multi-joint exoskeletons, non-human studies, and simulation-based analyses. Two reviewers independently extracted study characteristics, participant demographics, device features, intervention protocols, and clinical and biomechanical outcomes. Risk of bias was assessed using RoB-2 for randomized controlled trials and ROBINS-I for non-randomized studies. RESULTS Thirty-two studies met the inclusion criteria. Most investigations involved healthy adults in feasibility or pilot settings, while a smaller subset included individuals with stroke, spinal cord injury, or orthopedic conditions or pediatric movement disorders. Across studies, knee exoskeletons demonstrated short-term improvements in spatiotemporal gait parameters, knee joint kinematics, and metabolic efficiency. However, substantial heterogeneity in device design, outcome metrics, and intervention duration leads to limited comparability across studies. Sample sizes were typically small, and follow-up outcomes were rarely reported, restricting the interpretation of the long-term clinical efficacy of these devices. CONCLUSIONS Knee exoskeletons demonstrate promising short-term functional and biomechanical benefits and are increasingly feasible within structured rehabilitation settings. While current evidence is limited by small sample sizes and brief follow-up, emerging data suggests the potential to enhance task-specific gait training. Larger, well-designed trials are needed to determine sustained clinical impact and integration into routine rehabilitation practice. CLINICALTRIAL This systematic review was registered in PROSPERO (CRD420261285256)
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 857-862
A Hybrid Multi-Joint Robotic Shoulder Exoskeleton for Stroke Rehabilitation
The appropriate functionality of the human shoulder including the shoulder girdle movements is crucial for effective use of the arm during activities of daily living (ADL). It is important to assist all shoulder degrees-of-freedom (DOFs) when implementing robotic exoskeletons for rehabilitation purposes to increase the range of motion (ROM) and avoid any joint axes misalignments between the robot and human's shoulder that cause discomfort to the user. In this paper, a new lightweight shoulder exoskeleton is proposed, which can provide anatomically accurate shoulder movements to the neurologically impaired subjects by assisting all of the human shoulder DOFs and can minimize any effect of joint axes misalignments. The description and operation of this hybrid multi-joint ergonomic mechanism is presented in detail. Its kinematics, preliminary workspace analysis and mechanical interference issues are examined using CAD software tools. The discussion and future work on the proposed robotic shoulder exoskeleton are given to indicate its benefits of larger workspace, intrinsic compliance and increased functionality.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 857-862
A Hybrid Multi-Joint Robotic Shoulder Exoskeleton for Stroke Rehabilitation
The appropriate functionality of the human shoulder including the shoulder girdle movements is crucial for effective use of the arm during activities of daily living (ADL). It is important to assist all shoulder degrees-of-freedom (DOFs) when implementing robotic exoskeletons for rehabilitation purposes to increase the range of motion (ROM) and avoid any joint axes misalignments between the robot and human's shoulder that cause discomfort to the user. In this paper, a new lightweight shoulder exoskeleton is proposed, which can provide anatomically accurate shoulder movements to the neurologically impaired subjects by assisting all of the human shoulder DOFs and can minimize any effect of joint axes misalignments. The description and operation of this hybrid multi-joint ergonomic mechanism is presented in detail. Its kinematics, preliminary workspace analysis and mechanical interference issues are examined using CAD software tools. The discussion and future work on the proposed robotic shoulder exoskeleton are given to indicate its benefits of larger workspace, intrinsic compliance and increased functionality.
- 1 December 2017
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 118, 219-230
Modelling of the human shoulder girdle as a 6-4 parallel mechanism with a moving scapulothoracic joint
- 1 December 2017
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 118, 219-230
Modelling of the human shoulder girdle as a 6-4 parallel mechanism with a moving scapulothoracic joint
- 23 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 47 (6) , 1134-1145
Review on Design and Control Aspects of Robotic Shoulder Rehabilitation Orthoses
Robotic rehabilitation devices are more frequently used for the physical therapy of people with upper limb weakness, which is the most common type of stroke-induced disability. Rehabilitation robots can provide customized, prolonged, intensive, and repetitive training sessions for patients with neurological impairments. In most cases, the robotic exoskeletons have to be aligned with the human joints and provide natural arm movements. This is a challenging task to achieve for one of the most biomechanically complex joints of human body, i.e., the shoulder. Therefore, specific considerations have been made in the development of various existing robotic shoulder rehabilitation orthoses. Different types of actuation, degrees of freedom (DOFs), and control strategies have been utilized for the development of these shoulder rehabilitation orthoses. This paper presents a comprehensive review of these shoulder rehabilitation orthoses. Recent advancements in the mechanism design, their advantages and disadvantages, overview of hardware, actuation system, and power transmission are discussed in detail with the emphasis on the assisted DOFs for shoulder motion. A brief overview of control techniques and clinical studies conducted with the developed robotic shoulder orthoses is also presented. Finally, current challenges and directions of future development for robotic shoulder rehabilitation orthoses are provided at the end of this paper.
- 23 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 47 (6) , 1134-1145
Review on Design and Control Aspects of Robotic Shoulder Rehabilitation Orthoses
Robotic rehabilitation devices are more frequently used for the physical therapy of people with upper limb weakness, which is the most common type of stroke-induced disability. Rehabilitation robots can provide customized, prolonged, intensive, and repetitive training sessions for patients with neurological impairments. In most cases, the robotic exoskeletons have to be aligned with the human joints and provide natural arm movements. This is a challenging task to achieve for one of the most biomechanically complex joints of human body, i.e., the shoulder. Therefore, specific considerations have been made in the development of various existing robotic shoulder rehabilitation orthoses. Different types of actuation, degrees of freedom (DOFs), and control strategies have been utilized for the development of these shoulder rehabilitation orthoses. This paper presents a comprehensive review of these shoulder rehabilitation orthoses. Recent advancements in the mechanism design, their advantages and disadvantages, overview of hardware, actuation system, and power transmission are discussed in detail with the emphasis on the assisted DOFs for shoulder motion. A brief overview of control techniques and clinical studies conducted with the developed robotic shoulder orthoses is also presented. Finally, current challenges and directions of future development for robotic shoulder rehabilitation orthoses are provided at the end of this paper.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 546-551
System integration of a solar sensor and a spherical parallel manipulator for a 3-axis solar tracker platform design
This paper presents the authors' ongoing work on designing a novel 3-axis solar tracker platform utilizing a 3-DOF spherical parallel manipulator with revolute joints and a solar sensor. The selected solar sensor and the SPM configuration are described in details. A novel approach is proposed for the SPM platform orientation estimation based on solar sensor measurements employing trigonometric identities and quaternion rotation representation. The proposed approach is experimentally verified using a SPM 3D-printed prototype equipped with a solar and an orientation sensors. It is assumed that the proposed concept for a novel 3-axis solar tracker platform can further applied to design novel mobile solar tracking systems.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 546-551
System integration of a solar sensor and a spherical parallel manipulator for a 3-axis solar tracker platform design
This paper presents the authors' ongoing work on designing a novel 3-axis solar tracker platform utilizing a 3-DOF spherical parallel manipulator with revolute joints and a solar sensor. The selected solar sensor and the SPM configuration are described in details. A novel approach is proposed for the SPM platform orientation estimation based on solar sensor measurements employing trigonometric identities and quaternion rotation representation. The proposed approach is experimentally verified using a SPM 3D-printed prototype equipped with a solar and an orientation sensors. It is assumed that the proposed concept for a novel 3-axis solar tracker platform can further applied to design novel mobile solar tracking systems.
- 28 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (10834435) , 1
Numerical Optimal Control of a Spherical Parallel Manipulator Based on Unique Kinematic Solutions
This paper presents a framework for generating optimal motor trajectories for a spherical parallel manipulator (SPM) with revolute joints, actuated by servomotors with default internal position control settings. The proposed framework consists of three phases. First, an approach to obtain unique forward kinematics is introduced, in order to relate the angular positions of the servomotors to the orientation of the SPM top mobile platform. Then, a configuration space for the SPM is defined by using numerical procedures, in order to guarantee the absence of singularities and of collisions between links during the motion of the manipulator. Finally, reference trajectories of the servomotors are defined via convex optimization. These trajectories determine an optimal evolution of the SPM motion based on the configuration space and original servomotor dynamics. The proposed strategy is experimentally demonstrated on a prototype of Agile Wrist SPM with three servomotors.
- 28 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (10834435) , 1
Numerical Optimal Control of a Spherical Parallel Manipulator Based on Unique Kinematic Solutions
This paper presents a framework for generating optimal motor trajectories for a spherical parallel manipulator (SPM) with revolute joints, actuated by servomotors with default internal position control settings. The proposed framework consists of three phases. First, an approach to obtain unique forward kinematics is introduced, in order to relate the angular positions of the servomotors to the orientation of the SPM top mobile platform. Then, a configuration space for the SPM is defined by using numerical procedures, in order to guarantee the absence of singularities and of collisions between links during the motion of the manipulator. Finally, reference trajectories of the servomotors are defined via convex optimization. These trajectories determine an optimal evolution of the SPM motion based on the configuration space and original servomotor dynamics. The proposed strategy is experimentally demonstrated on a prototype of Agile Wrist SPM with three servomotors.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 285-290
Adaptive joint trajectory generator based on a chaotic recurrent neural network
The aim of this paper is to introduce a scalable and adaptable joint trajectory generator based on a recurrent neural network. As main application we target highly redundant kinematic structures like humanoid and multi-legged robotic systems. The network architecture consists of a set of leak integrators which outputs are limited by sigmoidal activation functions. The neural circuit exhibits very rich dynamics and is capable to generate complex periodic signals without the direct excitation of external inputs. Spontaneous internal activity is possible thanks to the presence of recurrent connections and a source of Gaussian noise that is overlapped with the signals. By modulating the internal chaotic level of the network it is possible to make the system exploring high-dimensional spaces and therefore to learn very complex time sequences. A preliminary set of simulations demonstrated how a relatively small network composed of hundred units is capable to generate different motor paths which can be triggered by exteroceptive sensory signals.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 285-290
Adaptive joint trajectory generator based on a chaotic recurrent neural network
The aim of this paper is to introduce a scalable and adaptable joint trajectory generator based on a recurrent neural network. As main application we target highly redundant kinematic structures like humanoid and multi-legged robotic systems. The network architecture consists of a set of leak integrators which outputs are limited by sigmoidal activation functions. The neural circuit exhibits very rich dynamics and is capable to generate complex periodic signals without the direct excitation of external inputs. Spontaneous internal activity is possible thanks to the presence of recurrent connections and a source of Gaussian noise that is overlapped with the signals. By modulating the internal chaotic level of the network it is possible to make the system exploring high-dimensional spaces and therefore to learn very complex time sequences. A preliminary set of simulations demonstrated how a relatively small network composed of hundred units is capable to generate different motor paths which can be triggered by exteroceptive sensory signals.