BUBaktharahalli Shantaveerappa Umesh

Baktharahalli Shantaveerappa Umesh

*This is an algorithmically generated author record based on publicly available information.

Baktharahalli Shantaveerappa Umesh has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Combinatory AC and DC Charging Approach for Electric Vehicles

    by Baktharahalli Shantaveerappa Umesh, Vinod Khadkikar, Hatem Zeineldin, Shakti Singh, Hadi Otrok, Rabeb Mizouni, Akshay Rathore

    Reducing the battery charging time of an electric vehicle (EV) is one of the key factors to boost the widespread adoption of EVs. The commercial, off-board high power, dc fast charging station need high initial investment and maintenance cost. On the other hand, the standard on-board type-1 and type-2 ac chargers with 3.3 $kW$ to 19 $kW$ need long time to charge. This paper proposes a combinatory ac and dc charging approach to increase the charging rate of EV batteries. The proposed combinatory charging approach provides a technique to charge EV battery from the on-board type-2 ac charger and drivetrain integrated dc charger. For drivetrain integrated dc charging, a dc input port $(N (+),O(-))$ is formed using the neutral of the EV motor winding $(N)$ and negative rail of the drivetrain inverter $(O)$ . Through this dc input port, power from the renewable energy source-based dc microgrids, solar rooftops and other EV battery can be accepted for charging. The EV drivetrain inverter is controlled as an integrated interleaved dc-dc converter (IDC) to receive power from dc sources with EV motor windings reutilized as filter inductors. The control scheme for regulating the voltage across common dc-link accepting power from type-2 ac charger and integrated interleaved dc charger is presented. The performance analysis of EV motor and drivetrain integrated DC charger is validated through Finiet Element methods (FEM) co-simulation using Ansys Maxwell and Simplorer. A scaled experimental prototype is developed to validate the proposed combined ac and dc charging approach.


  • Electric Vehicle-to-Vehicle Energy Transfer Using On-Board Converters

    by Azizulrahman Shafiqurrahman, B. S. Umesh, Naji Al Sayari, Vinod Khadkikar

    Electric vehicle-to-vehicle (V2V) charging is a recent approach for sharing energy among electric vehicles (EVs). Existing V2V approaches with an off-board power-sharing interface add extra space and cost for EV users. Furthermore, V2V power transfer using on-board type-2 chargers reported in the literature is not efficient due to redundant conversion stages. This article proposes a new method for V2V power transfer by directly connecting the two EV batteries together for sharing energy through the type-2 ac charger input ports and switches. The active rectifiers of on-board type-2 chargers are not used for rectification during V2V charging, instead only a few switches are used as interfaces to connect the two EV batteries together, to avoid redundant power conversion and associated losses which effectively improve the overall V2V efficiency. The possible V2V charging scenarios of the proposed V2V approach are validated using a MATLAB/Simulink simulation study. Furthermore, a scaled experimental prototype is developed to validate the proposed V2V method practically.


  • Reduced-Order Generalized Integrator-Based Phase-Locked Loop: Performance Improvement for Grid Synchronization of Single-Phase Inverters

    by Abdullahi Bamigbade, B. S. Umesh, Vinod Khadkikar, Mohamed Shawky El Moursi, H. H. Zeineldin, Mohamed Al Hosani

    Generalized integrator-based orthogonal signal generator phase-locked loops (GI-OSG PLLs) are very popular in single-phase grid synchronization. Generally speaking, the OSG of this PLL is realized from a second-order integrator perspective. As a result, the OSG implementation impacts the PLL dynamics. Improving the PLL performance by employing a reduced-order OSG implementation is the main motivation for this paper. Therefore, a reduced order-OSG PLL is proposed. In the proposed PLL, a single state and two output equations are employed to obtain a pair of orthogonal signals. This results in the loss of orthogonality between the OSG outputs and the single-phase supply voltage. Also, harmonic filtering capability provided by SOGI-OSG becomes non-existent. These issues are resolved by incorporating steady-state phase angle-offset error compensation at the PLL output and a moving average filter (MAF) within the PLL loop. To counteract the influence of MAF on the PLL’s stability and dynamics performance, a phase-lead compensator is designed. Through experimental studies, it is shown that the proposed reduced order-OSG PLL offers excellent dynamic performance. Also, the proposed PLL achieves minimal fluctuation of PV power when employed for grid synchronization of a PV system.


  • Direct Electric Vehicle to Vehicle (V2V) Power Transfer Using On-Board Drivetrain and Motor Windings

    by Umesh B S, Vinod Khadkikar, Hatem H. Zeineldin, Shakti Singh, Hadi Otrok, Rabeb Mizouni

    Vehicle to vehicle (V2V) energy sharing is emerging as an alternate solution to range anxiety and limited charging infrastructure challenges associated with electric vehicles (EVs). The existing off-board dc fast charging options for V2V application found in the literature are not effective due to the additional weight, size and cost of the external charger or interface. In this article, a new V2V interface is proposed in which both EV’s motor winding neutrals and negative rails of on-board drivetrains are directly connected to each other. This further helps in forming an integrated dual bidirectional dc–dc converter to control the direction of power flow. The proposed approach does not require reconfiguration of motor winding or mechanical clutch to arrest the motor from rotating and/or the reconfiguration of drivetrain inverter connections. The major hardware requirement for the proposed approach is, access to the already existing neutral connection of the EV motor phase windings. To achieve dc fast charging, all three-legs of voltage source inverter of energy Provider-EV are switched using interleaved pulsewidth modulation. Furthermore, finite element analysis is presented for 150 kW EV motor model and its performance validation with the high frequency dc current flowing in the motor windings during the V2V operation. A scaled lab prototype is developed to demonstrate the energy sharing between two Lithium-ion battery banks through the proposed direct V2V power transfer concept.


  • Multilevel Inverter Scheme for Performance Improvement of Pole Phase Modulated Multiphase Induction Motor Drive

    by Umesh S., Keerthipati Sivakumar

    Pole-phase modulation (PPM) is one of the effective speed and torque control techniques for multiphase induction motor (MIM) drives. Performance of the drive in low-pole high-speed mode for steady run is good even with two-level voltage excitation due to the inherent advantages of high phase number. The drive operation under high-pole high-torque starting mode suffers degradation in performance due to reduction in phase number in a way to increase number of poles. Extending conventional multilevel converter topologies for performance improvement of MIMs increases the device count and control complexity considerably. In this paper, a simple technique to generate multilevel voltage across the phase of a pole-phase-modulated induction motor (PPM IM), for improving the performance of the drive under high-pole operation is presented. The technique requires least changes in the control scheme and no additional switches for the power circuit. Exploiting the advantages of equal voltage profile coils (EVPCs) for carrier phase-shifted PWM control is the main focus of this paper. In addition, generalization of PPM is revisited in this paper to add a small constraint on the pole ratio to avoid unequal pole width for some pole-phase combinations. The effectiveness of the proposed scheme is shown through simulation with finite-element method (FEM) model of nine-phase squirrel cage induction motor and two-level nine-phase inverter cosimulated in Ansys Maxwell two-dimensional (2-D) and Simplorer environment. Experimental validation is also done on 5 hp nine-phase two-level induction motor drive controlled using Spartan6 FPGA board.


  • 15 phase induction motor drive with 1∶3∶5 speed ratios using pole phase modulation

    by Umesh B S, Sivakumar K

    Pole phase modulation (PPM) is one of the effective technique to control speed and torque of multiphase machines. This paper presents the winding details and finite element analysis (FEA) of 15 phase squirrel cage induction motor (IM) drive with 1:3:5 speed ratios using PPM. The proposed 15 phase IM with 60 stator slots and full pitched winding is able to run in five different pole-phase combinations with best utilization of copper. The 15 phase IM fed by a 15 leg inverter is operated in 15 phase 4 pole, 5 phase 12 pole, 3 phase 20 pole, 5 phase 4 pole and 3 phase 4 pole combinations. In addition Generalization of PPM is revisited in this paper to add an extra constraint on the pole ratio by showing an exception for the already proposed generalization of PPM. The operation of the proposed drive for five different pole-phase combinations with three possible speeds is verified by FEA simulation using Ansys Maxwell 2D (FEA package for electromagnetic design) and Simplorer for 2kw IM drive prototype with 10Nm load torque.


  • A fault tolerant dual inverter configuration for islanded mode photovoltaic generation system

    by Madhukar Rao A, Umesh B S, Sivakumar K

    In this paper a fault tolerant dual inverter configuration is proposed for a islanded mode PV generation system. The proposed system is capable to maintain the desired output voltage even under any fault in one of the PV string and/or corresponding inverter. In the dual inverter configuration the DC link voltage requirement of each inverter is half compared to single centralized inverter configuration. So the number of series connected PV panels in each PV string is half compared to single PV string of centralized inverter which in turn increases the reliability of the generation system. The voltage rating of switches will also reduce to half compared to a conventional centralized inverter. In the proposed system the primary windings of a three phase transformer (center tapped) are fed by dual inverters from both ends. The center tapings are connected through mechanical relays in order to provide fault tolerance ability to the system. Under normal operating condition, mechanical relays remain open and the primary windings will have resultant three level voltage profile. In case of any fault in one side of the system, mechanical relays are closed so that center tapings are shorted to connect half of the primary windings in star across the healthy side inverter. This arrangement maintains constant volt per turn in the three phase transformer which in turn maintains desired output voltage even during fault time. Decoupled SVPWM is used to control both the inverters which provide an advantage to control each inverter independently without disturbing other. So during fault condition faulty side inverter is made inoperative without any control complexity. As the healthy side inverter is rated half of the system rating, some less important loads are scheduled to be off during fault condition which avoids the overloading of the healthy side inverter. The proposed system is simulated for total power rating of 8kVA with two 4kVA inverters in dual configuration using MATLAB/Simulink.