JAJolanta Antoniewicz-Papis

Jolanta Antoniewicz-Papis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jolanta Antoniewicz-Papis has a total of 353 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Blood transfusion service in Poland in 2024 (an update of the 2023 data)

    by Anna Nieradkiewicz, Elżbieta Lachert, Paulina Goczyńska, Joanna Lasocka, Agata Mikołowska, Jolanta Antoniewicz-Papis

    Background: The aim of this study is to present the basic aspects of the activity of the Polish blood transfusion service in 2024. Material and methods: Analysis of data forwarded to the Institute of Hematology and Transfusion Medicine by the Polish Blood Transfusion Centers (Centers). Results: In 2024, there were 23 Centers and 133 local collection sites operating in Poland. Blood and blood components were also collected during 10,878 mobile collections. The overall number of blood donors was estimated at 651,234, the majority of whom were non-remunerated donors (651,004, including 28,832 responders to donation appeals) as well as 16 remunerated donors and 214 autologous donors. Most frequent were whole blood (WB) collections (1,373,400 donations), and the least frequent were granulocyte concentrate collections (84 donations) and collections by apheresis (Aph) of red blood cells (RBCs) as the only component (39 donations). Whole blood was collected mostly in local collection sites (51.73%), and less frequently in Centers (29.34%) and during mobile collections (18.92%). The most frequently prepared blood components were RBCs (1,369,449 units) and FFP (1,692,039 units). In 2024, a total of 102,674 units of platelet concentrates (PCs) pooled from WB and 60,966 units of PCs from Aph were prepared. Additional processing methods (leukocyte depletion, irradiation) were more frequently applied to PCs (only leukodepleted PCs were issued for clinical use), of which 52.14% were both leukodepleted and irradiated). Pathogen reduction technologies were applied to 29.09% of FFP units issued for clinical use and 15.14% of PCs. In 2024, 27.32% of RBCs were leukodepleted, 11.36% were irradiated, and 0.05% were irradiated and leukodepleted. For various reasons the following amounts of blood components were wasted in 2024: 12,669 units of WB, 36,765 units of RBCs, 66,636 units of FFP, 2380 units of PCs-Aph, 4710 units of pooled PCs, and 1636 units of cryoprecipitate, giving a total of 124,795 units of blood. As compared to the years 2021–2023, the value of most indicators of the activity of the blood transfusion service in Poland has increased. Conclusions: The data presented in this report may serve as a starting point for the analysis of issues related to the activity of organisational units of the Polish blood transfusion service. Keywords: blood donors blood donation blood components

  • Polska służba krwi — dane za rok 2024 (aktualizacja danych z 2023 roku)

    by Anna Nieradkiewicz, Elżbieta Lachert, Paulina Goczyńska, Joanna Lasocka, Agata Mikołowska, Jolanta Antoniewicz-Papis

    Wstęp: Celem niniejszego opracowania jest przedstawienie podstawowych aspektów działalności jednostek organizacyjnych polskiej służby krwi w 2024 roku. Materiał i metody: Analiza danych dostarczonych przez Centra Krwiodawstwa i Krwiolecznictwa (CKiK). Wyniki: W 2024 roku na terenie Polski działały 23 CKiK i 133 oddziały terenowe (OT), przeprowadzono także 10 878 ekip wyjazdowych. Krew oddało 651 234 osób, z czego większość to dawcy honorowi — 651 004 osób, w tym 28 832 dawców „na apel” — ponadto 16 dawców płatnych i 214 autologicznych. Najczęściej pobierano krew pełną (1 373 400 donacji), najrzadziej natomiast granulocyty (84 donacje) i erytrocyty pobierane metodą aferezy jako jedyny składnik (39 donacji). Krew pełną pobierano przede wszystkim w OT (51,73%), rzadziej w siedzibach CKiK (29,34%) i w czasie ekip wyjazdowych (18,92%). Najczęściej otrzymywane składniki krwi to koncentrat krwinek czerwonych (KKCz) (1 369 449 j.) i świeżo mrożone osocze (FFP, fresh frozen plasma) (1 692 039 j.). W 2024 roku otrzymano w sumie 102 674 opakowań zlewanego ubogoleukocytarnego koncentratu krwinek płytkowych (Zl. UKKP) i 60 966 opakowań UKKP metodą aferezy (UKKP-Af.). Dodatkowe metody preparatyki (usuwanie leukocytów, napromieniowanie) stosowano przede wszystkim w stosunku do UKKP. Do użytku klinicznego otrzymywano wyłącznie UKKP, z czego 52,14% stanowiły UKKP poddane napromieniowaniu (NUKKP). W roku 2024 uzyskano także 27,32% ubogoleukocytarnego KKCz (UKKCz), 11.36% napromieniowanego UKKCz (NUKKCz) i 0,05% napromieniowanego KKCz (NKKCz). Inaktywacji czynników zakaźnych poddano łącznie 29,09% j. FFP wydanego do szpitali i 15,14% opakowań UKKP. W 2024 roku zniszczono 124 795 j. krwi i jej najczęściej stosowanych składników, w tym 12 669 j. krwi pełnej konserwowanej (KPK), 36 765 j. KKCz, 66 636 j. FFP, 2 380 opakowań UKKP-Af., 4 710 opakowań Zl. UKKP, a także 1 636 j. krioprecypitatu. W 2024 roku nastąpił wzrost niektórych wartości analizowanych wskaźników dotyczących działalności służby krwi w Polsce w porównaniu z latami 2021–2023. Wnioski: Dane przedstawione w publikacji mogą służyć jako punkt wyjścia do analizy zagadnień związanych z funkcjonowaniem jednostek organizacyjnych publicznej służby krwi w Polsce oraz porównaniu doświadczeń i oceny stosowanych metod działania w celu wypracowania optymalnych rozwiązań. Keywords: krwiodawcy krwiodawstwo składniki krwi

  • International Forum on Transfusion Practices in Haematopoietic Stem‐Cell Transplantation: Responses

    by Pilar Solves, Miquel Lozano, Eugene Zhiburt, Javier Anguita Velasco, Ana Maria Pérez‐Corral, Silvia Monsalvo‐Saornil, Sho Yamazaki, Hitoshi Okazaki, Kathleen Selleng, Konstanze Aurich, et al.

  • International Forum on Transfusion Practices in Haematopoietic Stem‐Cell Transplantation: Summary

    by Pilar Solves, Miquel Lozano, Eugene Zhiburt, Javier Anguita Velasco, Ana Maria Pérez‐Corral, Silvia Monsalvo‐Saornil, Sho Yamazaki, Hitoshi Okazaki, Kathleen Selleng, Konstanze Aurich, et al.


  • Open Access

    Microbial contamination risk in hematopoietic stem cell products: retrospective analysis of 1996–2016 data

    by Jolanta Antoniewicz-Papis, Elżbieta Lachert, Aleksandra Rosiek, Magdalena Łętowska

    Quality assurance and safety of hematopoietic stem cells (HSC) with special emphasis on bacterial and fungal contamination is the prerequisite for any transplantation procedure. The aim was to determine the incidence rate of such contamination during processing of transplantation material with regard to HSC source: peripheral blood stem cell (PBSC), bone marrow (BM), or cord blood (CB). Analysis involved autologous and allogenic products dedicated for patients and comprised in all 4135 donations, including 112 BM (2.70%), 3787 PBSC (91.60%), and 236 CB (5.70%) processed in cell bank over the period 1996–2016. Aerobic and anaerobic contamination was determined. Analysis of the 20-year data revealed 42 contaminated products: 25 PBSC (0.66% of tested units) and 17 CB (7.20% of tested units). No microbial contamination of BM products was detected. Overall percentage of contaminated products was 1.01%, mostly with Staphylococcus epidermidis (61.36%). Bacterial contamination rate at cell bank is relatively low and processing in a closed system does not seem as crucial as might be expected. This is particularly true for BM components. Equally important are evaluation of donor’s medical status and condition of the puncture site for collection of source material. Implementation of appropriate sample collection procedures should help minimize the risk of false-positive results due to environmental contamination.


  • Open Access

    Quality control of riboflavin-treated platelet concentrates using Mirasol® PRT system: Polish experience

    by Elżbieta Lachert, Jolanta Kubis, Jolanta Antoniewicz-Papis, Aleksandra Rosiek, Jolanta Woźniak, Dariusz Piotrowski, Zofia Przybylska, Agata Mikołowska, Susanne Marschner, Magdalena Łętowska

    Background. The quality of platelet concentrates (PCs) is affected by preparation, storage, the type of container, and pathogen reduction technology (PRT). The Mirasol (R) Pathogen Reduction Technology (PRT) system (Terumo BCT Inc., Lakewood, USA), which uses riboflavin and ultraviolet (UV) light, has recently been proven effective against bacteria, viruses, parasites, and leukocytes. Objectives. The aim of the study was to evaluate the effect of the Mirasol (R) PRT system, based on riboflavin and UV light exposure, on the most common in vitro platelet quality parameters of PCs prepared from whole blood-derived buffy coats. Material and methods. The study included 15 trials (n = 15). For each trial, 2 PCs were used: 1 for treatment with the Mirasol (R) PRT system (M) and 1 for a control (C). In the M group, PCs were illuminated. In the C group, saline solution was added. PCs from groups M and C were stored at 20-24 degrees C, with agitation. Samples were collected on days 1, 3 and 5 to determine platelet concentration, total platelet count/unit, mean platelet volume (MPV), power of hydrogen (pH), glucose and beta-thromboglobulin concentration (BTG), hypotonic shock response (HSR), aggregation, CD42b and CD62P expression, pCO(2), and pO(2). Results. No significant differences in HSR or CD42b expression were observed between groups M and C. All pH values were stable during the whole storage period (7.1-7.5). On storage day 1, CD62P expression in group C was significantly higher than in group M. In the Mirasol (R) group, significantly higher glucose consumption was noted on storage days 3 and 5. On day 5, a 2-3-fold increase in BTG was observed in both groups as compared to day 1; on day 5, BTG concentration was 32% higher in group M than in group C. On all storage days, pCO(2) was comparable in groups M and C; lower pO(2) values were reported for group M. Conclusions. In vitro results demonstrated that pH, HSR, aggregation, CD42b antigen expression, and MPV and platelet count parameters were comparable in groups M and C.


  • Molecular and serological infection marker screening in blood donors indicates high endemicity of hepatitis E virus in Poland

    by Piotr Grabarczyk, Ewa Sulkowska, Jolanta Gdowska, Aneta Kopacz, Grzegorz Liszewski, Dorota Kubicka‐Russel, Sally A. Baylis, Victor M. Corman, Ewa Noceń, Dariusz Piotrowski, et al.

    BACKGROUND: Until now, markers of hepatitis E virus (HEV) infection have not been studied in blood donors throughout Poland, and no acute case of HEV infection has been closely documented or confirmed by HEV RNA detection. The prevalence of HEV infection markers, including HEV RNA in Polish blood donors and virus genotypes was investigated.STUDY DESIGN AND METHODS: In total, 12,664 individual donations from 22 Polish blood transfusion centers were tested for HEV RNA by transcription‐mediated amplification. In addition, 3079 first‐time donors sampled throughout Poland also were screened for antibodies to HEV. HEV RNA and immunoglobulin M‐positive donations were confirmed using real‐time reverse transcription‐polymerase chain reaction and Western blotting, respectively.RESULTS: Ten donors were identified as RNA initial reactive (one of 1266 donors), and six (one of 2109) were identified as repeat reactive and confirmed by real‐time reverse transcription‐polymerase chain reaction or seroconversion. Sequence analysis identified HEV Genotype 3c in one donor and Genotype 3i in two others. On average, 43.5% of donors were immunoglobulin G‐positive. Immunoglobulin G seroprevalence ranged from 22.7% to 60.8% in group ages 18 to 27 years and 48 to 57 years, respectively and differed between administrative regions from 28.9% in Podlasie to 61.3% in Wielkopolska. Thirty‐nine of the donors were immunoglobulin M‐positive, and seven donors were IgM positive only (0.2%). Of 37 immunoglobulin M‐reactive samples tested by Western blot, 24 (64.9%) were confirmed.CONCLUSIONS: The current results indicate a high level of HEV endemicity throughout Poland compared with other countries. There is an urgent need to consider the protection of recipients of blood components against transfusion‐transmitted HEV infection.


  • Open Access

    Identification and follow-up of pregnant women with platelet-type human platelet antigen (HPA)-1bb alloimmunized with fetal HPA-1a

    by Marzena Dębska, Małgorzata Uhrynowska, Katarzyna Guz, Izabella Kopeć, Elżbieta Lachert, Agnieszka Orzińska, Piotr Kretowicz, Jolanta Antoniewicz-Papis, Romuald Dębski, Magdalena Łętowska, et al.

    Introduction : Pregnant women negative for human platelet antigen 1 a (HPA-1a) are at risk of alloimmunization with fetal HPA-1a antigen inherited from the father, and their offspring may develop fetal and neonatal alloimmune thrombocytopenia (FNAIT). The aim of this study was to analyze the...