Yu Zheng Chong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yu Zheng Chong has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Alpha Agape Gopalai
Department of Electrical and Robotics Engineering, School of Engineering, Monash University Malaysia, Sunway, Malaysia
3 shared publications - Darwin Gouwanda
School of Engineering, Monash University Malaysia, Bandar Sunway, Malaysia
3 shared publications Jasmy Yunus
Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul Takzim, Malaysia
3 shared publicationsJonathan Shi Khai Ooi
3 shared publications- Sawal Hamid Md Ali
Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia
3 shared publications Siti Anom Ahmad
3 shared publications
Latest Publications
- 6 October 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (2)
Musculoskeletal Gait Simulation to Investigate Biomechanical Effect of Knee Brace
Musculoskeletal modeling and simulation have been an emerging trend in human gait analysis. It allows the user to isolate certain biomechanical conditions and elucidate the dynamics of joints and muscles. This study used an open-source musculoskeletal modeling and simulation tool, opensim to investigate the biomechanical effect of knee brace. It collected gait data from thirty-eight participants and examined the gait spatio-temporal parameters, joint angles, and joint moments. Static optimization was performed to estimate the lower extremity muscle force. Statistical analysis was conducted to identify the difference between normal and braced gaits. The results demonstrated the feasibility of this method to investigate the interaction and coordination of lower extremity joints and muscles. The knee brace constrained the range of the motion of the knee during walking. It also changed the walking speed, step length, and stance-to-swing ratio. Several significant differences were found in the joint moments and muscle forces of the rectus femoris, gastrocnemius, soleus and tibialis anterior. Musculoskeletal modeling and simulation tool offers a less invasive and practical alternative to analyze human motion. It also provides a means to investigate the effect of medical devices such as knee brace, which can be potentially beneficial for the future design and development of such devices and for the derivation of future rehabilitation treatment to improve patient's gait.
- 6 October 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (2)
Musculoskeletal Gait Simulation to Investigate Biomechanical Effect of Knee Brace
Musculoskeletal modeling and simulation have been an emerging trend in human gait analysis. It allows the user to isolate certain biomechanical conditions and elucidate the dynamics of joints and muscles. This study used an open-source musculoskeletal modeling and simulation tool, opensim to investigate the biomechanical effect of knee brace. It collected gait data from thirty-eight participants and examined the gait spatio-temporal parameters, joint angles, and joint moments. Static optimization was performed to estimate the lower extremity muscle force. Statistical analysis was conducted to identify the difference between normal and braced gaits. The results demonstrated the feasibility of this method to investigate the interaction and coordination of lower extremity joints and muscles. The knee brace constrained the range of the motion of the knee during walking. It also changed the walking speed, step length, and stance-to-swing ratio. Several significant differences were found in the joint moments and muscle forces of the rectus femoris, gastrocnemius, soleus and tibialis anterior. Musculoskeletal modeling and simulation tool offers a less invasive and practical alternative to analyze human motion. It also provides a means to investigate the effect of medical devices such as knee brace, which can be potentially beneficial for the future design and development of such devices and for the derivation of future rehabilitation treatment to improve patient's gait.
- 24 February 2021
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 59 (3) , 711-720
The effect of asymmetrical gait induced by unilateral knee brace on the knee flexor and extensor muscles
Asymmetrical stiff knee gait is a mechanical pathology that can disrupt lower extremity muscle coordination. A better understanding of this condition can help identify potential complications. This study proposes the use of dynamic musculoskeletal modelling simulation to investigate the effect of induced mechanical perturbation on the kneeand to examine the muscle behaviour without invasive technique. Thirty-eight healthy participants were recruited. Asymmetrical gait was simulated using knee brace. Knee joint angle, joint moment and knee flexor and extensor muscle forces were computed using OpenSim. Differences inmuscle force between normal and abnormal conditions were investigated using ANOVA and Tukey-Kramer multiple comparison test.The results revealed that braced knee experienced limited range of motion with smaller flexion moment occuring at late swing phase. Significant differences were found in all flexormuscle forces and in several extensor muscle forces (p<0.05). Normal knee produced larger flexor muscle force than braced knee. Braced knee generated the largest extensor muscle force at early swing phase. In summary, musculoskeletal modelling simulation can be a computational tool to map and detect the differences between normal and asymmetrical gaits. Graphical abstract
- 24 February 2021
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 59 (3) , 711-720
The effect of asymmetrical gait induced by unilateral knee brace on the knee flexor and extensor muscles
Asymmetrical stiff knee gait is a mechanical pathology that can disrupt lower extremity muscle coordination. A better understanding of this condition can help identify potential complications. This study proposes the use of dynamic musculoskeletal modelling simulation to investigate the effect of induced mechanical perturbation on the kneeand to examine the muscle behaviour without invasive technique. Thirty-eight healthy participants were recruited. Asymmetrical gait was simulated using knee brace. Knee joint angle, joint moment and knee flexor and extensor muscle forces were computed using OpenSim. Differences inmuscle force between normal and abnormal conditions were investigated using ANOVA and Tukey-Kramer multiple comparison test.The results revealed that braced knee experienced limited range of motion with smaller flexion moment occuring at late swing phase. Significant differences were found in all flexormuscle forces and in several extensor muscle forces (p<0.05). Normal knee produced larger flexor muscle force than braced knee. Braced knee generated the largest extensor muscle force at early swing phase. In summary, musculoskeletal modelling simulation can be a computational tool to map and detect the differences between normal and asymmetrical gaits. Graphical abstract
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1372 (1)
Development of an Affordable, Accessible, and Available (3As) IoT-Enabled Motion Analysis System for Stroke Recovery Monitoring – An Introductory Approach
According to the United Nations Sustainable Development Goals (SDGs) formulated in 2015, there are seventeen (17) identified goals aimed to be achieved by 2030. This project was focussed on SDG 3, SDG 10, and SDG 11 [1]. The developed motion analysis system adopted principles of Affordability, Accessibility, and Availability of this system for monitoring of stroke patients who are undergoing physical therapy (PT). Such system will enable stakeholders involved in rehabilitation of these communities to monitor the progress of PT regime that will be vital in determining efficacy of the regime. Furthermore, the proposed system has the capabilities of remote monitoring, and data acquisition via the IoT platform. The cost of developing this modular system was less than RM 1,000 (approximately USD 243) [2]. Hence, it is anticipated that this project will be a stepping stone towards 3As of motion analysis for stroke patients.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1372 (1)
Open AccessDevelopment of an Affordable, Accessible, and Available (3As) IoT-Enabled Motion Analysis System for Stroke Recovery Monitoring – An Introductory Approach
According to the United Nations Sustainable Development Goals (SDGs) formulated in 2015, there are seventeen (17) identified goals aimed to be achieved by 2030. This project was focussed on SDG 3, SDG 10, and SDG 11 [1]. The developed motion analysis system adopted principles of Affordability, Accessibility, and Availability of this system for monitoring of stroke patients who are undergoing physical therapy (PT). Such system will enable stakeholders involved in rehabilitation of these communities to monitor the progress of PT regime that will be vital in determining efficacy of the regime. Furthermore, the proposed system has the capabilities of remote monitoring, and data acquisition via the IoT platform. The cost of developing this modular system was less than RM 1,000 (approximately USD 243) [2]. Hence, it is anticipated that this project will be a stepping stone towards 3As of motion analysis for stroke patients.
- 1 September 2019
- Published by Penerbit UTHM in International Journal of Integrated Engineering
- Vol. 11 (3)
Instantaneous Segmental Energy Symmetry Index as Gait Compensation Indicator in Asymmetrical Walking
- 1 September 2019
- Published by Penerbit UTHM in International Journal of Integrated Engineering
- Vol. 11 (3)
Instantaneous Segmental Energy Symmetry Index as Gait Compensation Indicator in Asymmetrical Walking
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 638-641
Development of Spatio-Temporal, and Kinetics Database of Undergraduate Malaysian University Students : Further Investigations, and Opportunities
Gait Analysis has been utilized to assist medical practitioners in diagnosis of various biomechanical deficiencies. Besides that, gait analysis were also applicable in various instances from footwear designs to development of various rehabilitation equipment. Hence, as such a dedicated gait database will be empirical in comparison between normal and abnormal. This paper outlines the development of such normaltive database primarily based on the Malaysian demographics. The study also found that normative data collection thus far shows that in this study demographics, the data agrees with currently available published reference data. Since the development of such database is still in its infancy in Malaysia, there will be much further development opportunities in this area of study.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 638-641
Development of Spatio-Temporal, and Kinetics Database of Undergraduate Malaysian University Students : Further Investigations, and Opportunities
Gait Analysis has been utilized to assist medical practitioners in diagnosis of various biomechanical deficiencies. Besides that, gait analysis were also applicable in various instances from footwear designs to development of various rehabilitation equipment. Hence, as such a dedicated gait database will be empirical in comparison between normal and abnormal. This paper outlines the development of such normaltive database primarily based on the Malaysian demographics. The study also found that normative data collection thus far shows that in this study demographics, the data agrees with currently available published reference data. Since the development of such database is still in its infancy in Malaysia, there will be much further development opportunities in this area of study.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1653-1656
Development of an Affordable Customisable Upper Extremities Pneumatically-Powered Exoskeleton
Affordability of biomechanical devices have been subjected to numerous discussion amongst users that requires such products. Therefore, this paper will explore on the possible affordable technologies that would enable the end-users to have access to the upper-extremities pneumatically-powered exoskeleton in daily life. Such devices will enable rehabilitation as well as assistances to individual that would require such assistive technology in their daily living. The customizable exoskeleton features adjustable arm-length for proper fitting to users. This exoskeleton is powered by McKibben pneumatic muscles mimicking muscles in the upper extremities. Moreover, the system enables remote monitoring via cloud or IoT platform. Future development of this prototype will be incorporation of more telerehabilitation features to improve adoption in user-friendliness of this enabling technology.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1653-1656
Development of an Affordable Customisable Upper Extremities Pneumatically-Powered Exoskeleton
Affordability of biomechanical devices have been subjected to numerous discussion amongst users that requires such products. Therefore, this paper will explore on the possible affordable technologies that would enable the end-users to have access to the upper-extremities pneumatically-powered exoskeleton in daily life. Such devices will enable rehabilitation as well as assistances to individual that would require such assistive technology in their daily living. The customizable exoskeleton features adjustable arm-length for proper fitting to users. This exoskeleton is powered by McKibben pneumatic muscles mimicking muscles in the upper extremities. Moreover, the system enables remote monitoring via cloud or IoT platform. Future development of this prototype will be incorporation of more telerehabilitation features to improve adoption in user-friendliness of this enabling technology.
- 1 July 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 76, 269-273
Estimation of vertical ground reaction force during running using neural network model and uniaxial accelerometer
- 1 July 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 76, 269-273
Estimation of vertical ground reaction force during running using neural network model and uniaxial accelerometer
- 1 January 2018
- Published by Inderscience Publishers in International Journal of Medical Engineering and Informatics
- Vol. 10 (1) , 16
Grove: an auxiliary device for sympathetic assessment via EDA measurement of neutral, stress, and anger emotions during simulated driving conditions
Cognition, emotion, and mood are one of the most researched topics in psychophysiological signal study. Heart rate, skin conductance, and skin temperature are popular measures of understanding autonomic nervous systems. These measures are tightly related to sympathetic and parasympathetic nervous system, which regulates human emotion. Stress and anger affect driving task and contribute to the high number of road crashes. This study utilised electrodermal activity (EDA) to differentiate stress and anger from the neutral emotion of drivers while performing a simulated driving task. Twenty healthy subjects participated and the experiment protocol was approved by Ethics Committee for Research Involving Human Subjects, Universiti Putra Malaysia. Mean power spectral density (PSD) of EDA signals were statistically compared between emotion groups with repeated-measures ANOVA and Bonferroni post hoc test. A significant difference (p < 0.01) was observed between neutral-anger and neutral-stress groups, whereas no significant difference (p > 0.01) was noted between stress-anger groups. Promising classification accuracy was achieved between emotion groups with support vector machine (SVM) classifier at ten-fold cross-validation.
- 1 January 2018
- Published by Inderscience Publishers in International Journal of Medical Engineering and Informatics
- Vol. 10 (1) , 16
Grove: an auxiliary device for sympathetic assessment via EDA measurement of neutral, stress, and anger emotions during simulated driving conditions
Cognition, emotion, and mood are one of the most researched topics in psychophysiological signal study. Heart rate, skin conductance, and skin temperature are popular measures of understanding autonomic nervous systems. These measures are tightly related to sympathetic and parasympathetic nervous system, which regulates human emotion. Stress and anger affect driving task and contribute to the high number of road crashes. This study utilised electrodermal activity (EDA) to differentiate stress and anger from the neutral emotion of drivers while performing a simulated driving task. Twenty healthy subjects participated and the experiment protocol was approved by Ethics Committee for Research Involving Human Subjects, Universiti Putra Malaysia. Mean power spectral density (PSD) of EDA signals were statistically compared between emotion groups with repeated-measures ANOVA and Bonferroni post hoc test. A significant difference (p < 0.01) was observed between neutral-anger and neutral-stress groups, whereas no significant difference (p > 0.01) was noted between stress-anger groups. Promising classification accuracy was achieved between emotion groups with support vector machine (SVM) classifier at ten-fold cross-validation.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 873-877
Development of portable hand cycle for children with cerebral palsy — The Malaysian scenario: Wheelchair propulsion motion
This paper discussed the development of handcycle for rehabilitation for children with cerebral palsy. According to various studies conducted in Malaysia, the Availability, Accessibility, and Affordability (3As) of rehabilitation devices or equipment are inadequate. Hence, this paper highlights one of the possible solution catering at rehabilitation of children with cerebral palsy. This handcycle was developed with support from IEEE-Special Interest Group in Humanitarian Technology (IEEE-SIGHT), My SI GHT 4Rehab. The proposed solution utilized readily available components to mimic wheelchair propulsion that will prepare these CP Children in the event of wheelchair utilization in their future daily life. The proposed system incorporated interactive training algorithms in addition to the hardware setup. Besides that, real-time tracking of the heart rate, and movement parameters were also made available alongside with interactive user interface. Furthermore, to fulfill the 3As requirements, the proposed solution was developed with cost of less than RM 500 (~USD 120). It is anticipated that the proposed system will be a catalyst in springboarding further development of such rehabilitation system.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 873-877
Development of portable hand cycle for children with cerebral palsy — The Malaysian scenario: Wheelchair propulsion motion
This paper discussed the development of handcycle for rehabilitation for children with cerebral palsy. According to various studies conducted in Malaysia, the Availability, Accessibility, and Affordability (3As) of rehabilitation devices or equipment are inadequate. Hence, this paper highlights one of the possible solution catering at rehabilitation of children with cerebral palsy. This handcycle was developed with support from IEEE-Special Interest Group in Humanitarian Technology (IEEE-SIGHT), My SI GHT 4Rehab. The proposed solution utilized readily available components to mimic wheelchair propulsion that will prepare these CP Children in the event of wheelchair utilization in their future daily life. The proposed system incorporated interactive training algorithms in addition to the hardware setup. Besides that, real-time tracking of the heart rate, and movement parameters were also made available alongside with interactive user interface. Furthermore, to fulfill the 3As requirements, the proposed solution was developed with cost of less than RM 500 (~USD 120). It is anticipated that the proposed system will be a catalyst in springboarding further development of such rehabilitation system.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Vehicle Safety
- Vol. 9 (3) , 181
A conceptual emotion recognition framework: stress and anger analysis for car accidents
In year 2013, 777,817 out of 22,702,211 of registered vehicles were involved in road traffic crashes, with a damage cost of more than 9.3 billion ringgits in Malaysia. Automotive makers have deployed a wide range of active safety systems (traction control, auto cruise and braking, collision avoidance, and lane switching) in recent years. However, these systems failed to significantly reduce road crash statistics. The automotive network comprises the vehicle, road and driver. Huge effort had been placed on the vehicle and road, whereas the driver remains the feeblest part. Consequently, automotive makers should focus their attention on monitoring drivers' emotion, which influences their driving behaviour. This study aims to explore available technology that monitors driver behaviour, besides proposing accident-stimulating emotion that affects driving. Furthermore, a conceptual framework for recognising anger and stress emotion, which is a cause of road crash, is proposed.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Vehicle Safety
- Vol. 9 (3) , 181
A conceptual emotion recognition framework: stress and anger analysis for car accidents
In year 2013, 777,817 out of 22,702,211 of registered vehicles were involved in road traffic crashes, with a damage cost of more than 9.3 billion ringgits in Malaysia. Automotive makers have deployed a wide range of active safety systems (traction control, auto cruise and braking, collision avoidance, and lane switching) in recent years. However, these systems failed to significantly reduce road crash statistics. The automotive network comprises the vehicle, road and driver. Huge effort had been placed on the vehicle and road, whereas the driver remains the feeblest part. Consequently, automotive makers should focus their attention on monitoring drivers' emotion, which influences their driving behaviour. This study aims to explore available technology that monitors driver behaviour, besides proposing accident-stimulating emotion that affects driving. Furthermore, a conceptual framework for recognising anger and stress emotion, which is a cause of road crash, is proposed.