Gennady Sidorov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gennady Sidorov has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Zhenan Jiang
Victoria University of Wellington
4 shared publications - Mike Staines
Victoria University of Wellington
3 shared publications - Rodney Alan Badcock
Victoria University of Wellington
3 shared publications Jin Fang
School of Electric Engineering, Beijing Jiaotong University, Beijing, China
2 shared publications- Mohammad Yazdani-Asrami
University of Glasgow
2 shared publications - Naoyuki Amemiya
Kyoto University
2 shared publications
Latest Publications
- 14 August 2020
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 33 (9) , 095014
Heat transfer and recovery performance enhancement of metal and superconducting tapes under high current pulses for improving fault current-limiting behavior of HTS transformers
High-temperature superconducting (HTS) transformer windings operate subcooled at atmospheric pressure to temperatures as low as 65 K, with minimal power dissipation from AC loss in normal operation. During short circuits, HTS transformers are subjected to transient heating by currents as large as 10 times the rated current for durations of up to 2 s. After isolating the fault, HTS transformers are required to cool back down to their base temperature while carrying the operating current. HTS transformer conductors are insulated, typically with wrapped self-adhesive polyimide tape, and windings consist of close-packed conductors wound on composite formers. In this paper, the heat transfer, transient thermal response, and recovery performance of brass-laminated coated conductor HTS wire as well as metallic conductors in liquid nitrogen (LN2) were measured at a range of temperatures from 77 K to 64 K and pressures from atmospheric to 0.14 bar in heating and cooling situations. Measurements were made on bare tapes, and on tapes wrapped with polyimide insulation tape and aramid paper as well as polymer-coated tapes with a range of coating thicknesses. Heat transfer from tapes mounted with one face in contact with a glass-epoxy composite cylindrical former was measured for comparison with free-standing tapes. Using conductors with solid polymer coatings of optimized thickness immersed in subcooled LN2 results in the highest heat transfer and fast recovery following heating to 300 K by a high current pulse. Compared to a bare tape in LN2 at ambient pressure at 77 K, the heat transfer in a coated tape in 65 K subcooled LN2 can be very significantly enhanced by up to a factor of 15, and recovery can be seven times faster.
- 14 August 2020
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 33 (9) , 095014
Heat transfer and recovery performance enhancement of metal and superconducting tapes under high current pulses for improving fault current-limiting behavior of HTS transformers
High-temperature superconducting (HTS) transformer windings operate subcooled at atmospheric pressure to temperatures as low as 65 K, with minimal power dissipation from AC loss in normal operation. During short circuits, HTS transformers are subjected to transient heating by currents as large as 10 times the rated current for durations of up to 2 s. After isolating the fault, HTS transformers are required to cool back down to their base temperature while carrying the operating current. HTS transformer conductors are insulated, typically with wrapped self-adhesive polyimide tape, and windings consist of close-packed conductors wound on composite formers. In this paper, the heat transfer, transient thermal response, and recovery performance of brass-laminated coated conductor HTS wire as well as metallic conductors in liquid nitrogen (LN2) were measured at a range of temperatures from 77 K to 64 K and pressures from atmospheric to 0.14 bar in heating and cooling situations. Measurements were made on bare tapes, and on tapes wrapped with polyimide insulation tape and aramid paper as well as polymer-coated tapes with a range of coating thicknesses. Heat transfer from tapes mounted with one face in contact with a glass-epoxy composite cylindrical former was measured for comparison with free-standing tapes. Using conductors with solid polymer coatings of optimized thickness immersed in subcooled LN2 results in the highest heat transfer and fast recovery following heating to 300 K by a high current pulse. Compared to a bare tape in LN2 at ambient pressure at 77 K, the heat transfer in a coated tape in 65 K subcooled LN2 can be very significantly enhanced by up to a factor of 15, and recovery can be seven times faster.
- 27 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (1) , 1-8
Shielding Effect of (RE)Ba2Cu3O7-d-Coated Conductors on Eddy Current Loss of Adjacent Metal Layers Under AC Magnetic Fields With Various Orientations
(RE)Ba 2 Cu 3 O 7 -d (REBCO) coated conductors are becoming a preferred wire choice for many potential high temperature superconducting (HTS) applications, where additional metal layers are usually attached to the REBCO conductors to improve reliability and stability. In such cases, the eddy current loss in the metal layers is affected by the magnetic field shielding by adjacent REBCO coated conductors. Here we present the ac loss measurement and simulation results in three copper-superconductor stacks comprising a 10-mm-wide Fujikura-coated conductor with one, two, and four 0.1-mm-thick, 10-mm-wide copper strips, under various applied magnetic field angles (defined by the angle between the applied magnetic field and the wide face of the superconductor) from 15° to 90° at 77 K. The amplitude of the magnetic field is up to 100 mT. The shielding effect, which reduces the eddy current loss in the metal layers stacked with a superconductor layer, increases with decreasing field angles, due to the change of the effective penetration field at the different field angles. The eddy current loss in the copper strips in the copper-superconductor stacks under the magnetic fields with various orientations is dominated by the perpendicular magnetic field component.
- 27 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (1) , 1-8
Shielding Effect of (RE)Ba2Cu3O7-d-Coated Conductors on Eddy Current Loss of Adjacent Metal Layers Under AC Magnetic Fields With Various Orientations
(RE)Ba 2 Cu 3 O 7 -d (REBCO) coated conductors are becoming a preferred wire choice for many potential high temperature superconducting (HTS) applications, where additional metal layers are usually attached to the REBCO conductors to improve reliability and stability. In such cases, the eddy current loss in the metal layers is affected by the magnetic field shielding by adjacent REBCO coated conductors. Here we present the ac loss measurement and simulation results in three copper-superconductor stacks comprising a 10-mm-wide Fujikura-coated conductor with one, two, and four 0.1-mm-thick, 10-mm-wide copper strips, under various applied magnetic field angles (defined by the angle between the applied magnetic field and the wide face of the superconductor) from 15° to 90° at 77 K. The amplitude of the magnetic field is up to 100 mT. The shielding effect, which reduces the eddy current loss in the metal layers stacked with a superconductor layer, increases with decreasing field angles, due to the change of the effective penetration field at the different field angles. The eddy current loss in the copper strips in the copper-superconductor stacks under the magnetic fields with various orientations is dominated by the perpendicular magnetic field component.
- 27 December 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (24) , 243904
Dynamic resistance measurement in a YBCO wire under perpendicular magnetic field at various operating temperatures
Dynamic resistance plays an important role in certain high-Tc superconducting (HTS) applications where an HTS coated conductor carries a DC current exposed to an AC magnetic field. Here, we report measurements of the dynamic resistance in a 4 mm-wide YBCO coated conductor under a perpendicular AC magnetic field at 77 K, 70 K, and 65 K. Dynamic resistance was measured at three different frequencies for the reduced current, i (It/Ic0), ranging from 0.04 to 0.9, where It is the DC current level and Ic0 is the self-field critical current of the conductor at each temperature. At all three temperatures, the threshold magnetic field (Bth) values increase with reducing DC current. These results show that, for a given set of applied conditions, dynamic resistance decreases with decreasing operating temperature, which we attribute to the temperature dependent increase in the critical current of the wire. We show that measured Bth values at all three temperatures agree well with the analytical values from nonlinear Mikitik and Brandt equation for i ≤ 0.2 and with a simple linear expression that assumes a current-independent penetration field for i > 0.2. We further show the measured Bth curves at different temperatures normalized by critical current density collapse into one common curve. The above result implies that dynamic resistance in coated conductors at different temperatures under perpendicular AC magnetic fields can be scaled simply using measured Ic0 values at those temperatures and analytical equations.
- 27 December 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (24) , 243904
Dynamic resistance measurement in a YBCO wire under perpendicular magnetic field at various operating temperatures
Dynamic resistance plays an important role in certain high-Tc superconducting (HTS) applications where an HTS coated conductor carries a DC current exposed to an AC magnetic field. Here, we report measurements of the dynamic resistance in a 4 mm-wide YBCO coated conductor under a perpendicular AC magnetic field at 77 K, 70 K, and 65 K. Dynamic resistance was measured at three different frequencies for the reduced current, i (It/Ic0), ranging from 0.04 to 0.9, where It is the DC current level and Ic0 is the self-field critical current of the conductor at each temperature. At all three temperatures, the threshold magnetic field (Bth) values increase with reducing DC current. These results show that, for a given set of applied conditions, dynamic resistance decreases with decreasing operating temperature, which we attribute to the temperature dependent increase in the critical current of the wire. We show that measured Bth values at all three temperatures agree well with the analytical values from nonlinear Mikitik and Brandt equation for i ≤ 0.2 and with a simple linear expression that assumes a current-independent penetration field for i > 0.2. We further show the measured Bth curves at different temperatures normalized by critical current density collapse into one common curve. The above result implies that dynamic resistance in coated conductors at different temperatures under perpendicular AC magnetic fields can be scaled simply using measured Ic0 values at those temperatures and analytical equations.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
AC Loss Measurement in HTS Coil Windings Coupled With Iron Core
Utilizing high temperature superconducting (HTS) magnets coupled with iron core on the rapid cycling synchrotrons is considered as an effective way to reduce their construction and running costs. However, the heat generation by ac loss in HTS wires is a critical obstacle for the application, and prediction and reduction of ac loss in HTS magnets coupled with iron core are essential. In this work, we built one HTS double pancake coil (DPC), a stack of two DPCs, and an iron core comprising laminated steel to couple with the coil windings. The HTS-coated conductors are 200 A-class 4-mm-wide Shanghai Conductors. We report the ac loss measurement results on the coil windings with/without the iron core at three different frequencies. The ac loss in the HTS windings was significantly increased due to the existence of the iron core. Increasing the number of stack of the DPCs may help reduce the difference in ac loss values in the coil windings with/without iron cores.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
AC Loss Measurement in HTS Coil Windings Coupled With Iron Core
Utilizing high temperature superconducting (HTS) magnets coupled with iron core on the rapid cycling synchrotrons is considered as an effective way to reduce their construction and running costs. However, the heat generation by ac loss in HTS wires is a critical obstacle for the application, and prediction and reduction of ac loss in HTS magnets coupled with iron core are essential. In this work, we built one HTS double pancake coil (DPC), a stack of two DPCs, and an iron core comprising laminated steel to couple with the coil windings. The HTS-coated conductors are 200 A-class 4-mm-wide Shanghai Conductors. We report the ac loss measurement results on the coil windings with/without the iron core at three different frequencies. The ac loss in the HTS windings was significantly increased due to the existence of the iron core. Increasing the number of stack of the DPCs may help reduce the difference in ac loss values in the coil windings with/without iron cores.
- 1 February 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (3) , 035006
Fault current limiting HTS transformer with extended fault withstand time
- 1 February 2019
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 32 (3) , 035006
Fault current limiting HTS transformer with extended fault withstand time
- 22 April 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 98041Q-98041Q-10
Non-destructive testing of critical infrastructure with giant magneto resistive sensors
- 22 April 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 98041Q-98041Q-10
Non-destructive testing of critical infrastructure with giant magneto resistive sensors
- 13 January 2010
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 23 (2)
Transport AC loss characteristics of a nine strand YBCO Roebel cable
- 13 January 2010
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 23 (2)
Transport AC loss characteristics of a nine strand YBCO Roebel cable