Andrew J. Carrod
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrew J. Carrod has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Karl Börjesson
Department of Chemistry and Molecular Biology University of Gothenburg Gothenburg Sweden
3 shared publications - Zoe Pikramenou
School of Chemistry, University of Birmingham, Edgbaston, B15 2TT, UK
3 shared publications Abiola N. Dosumu
University of Birmingham
1 shared publication- Alesia A. Tietze
University of Gothenburg
1 shared publication - Alexei Cravcenco
Department of Chemistry and Molecular Biology, University of Gothenburg, Kemigården 4, 41296 Göteborg, Sweden
1 shared publication - Andrew D. Ward
STFC, Central Laser Facility, Research Complex at Harwell, Rutherford Appleton Laboratory, Harwell Oxford, Didcot, Oxfordshire OX11 0FA, U.K.
1 shared publication
Latest Publications
- Open Access
- 9 December 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (3) , 1293-1301
Separating triplet exciton diffusion from triplet–triplet annihilation by the introduction of a mediator
The functions of triplet diffusion and annihilation are seperated into two different molecules by using triplet triplet annihilation between two diffrenet molecular species, allowing for photon upconversion at low annihilator concentrations.
- 9 December 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (3) , 1293-1301
Open AccessSeparating triplet exciton diffusion from triplet–triplet annihilation by the introduction of a mediator
The functions of triplet diffusion and annihilation are seperated into two different molecules by using triplet triplet annihilation between two diffrenet molecular species, allowing for photon upconversion at low annihilator concentrations.
- Open Access
- 4 June 2024
- Published by American Chemical Society (ACS) in ACS Organic & Inorganic Au
- Vol. 4 (5) , 517-525
Fluorescence Labeling of Peptides: Finding the Optimal Protocol for Coupling Various Dyes to ATCUN-like Structures
Labeling of peptides and proteins with fluorescent dyes is a key step in functionalizing these structures for a wide array of biological assays. However, coupling strategies of such dyes have not been optimized for the most common compounds, while this step is typically the most precious and costly of the whole synthesis. We searched for the best conditions for attachment of the most widely used fluorescent dyes such as 6-carboxyfluorescein, Rhodamine B, and BODIPY-FL to peptides, where amino terminal Cu(II) and Ni(II) binding site (ATCUN) peptides were used as a model system. Surprisingly, conventional methods of dye attachment proved to not be satisfactory and yielded poor efficiency results. We have discovered that when labeling primary amines on peptides, the uncommon synthesis of activated pentafluorophenol (PFP) esters is the most efficient strategy, expedited by microwave irradiation. Coupling to secondary amines is achieved most efficiently through conventional coupling reagents such as HATU and PyBOP. Furthermore, we have employed our fluorescently labeled ATCUN peptides in studies for Cu(II) and Ni(II) sensing, showing that changing the fluorophore does not significantly affect the fluorescence quenching process and discovering the optimal linker length between the ATCUN core and the dye, expanding the repertoire of fluorophores that can be used in this application.
- 4 June 2024
- Published by American Chemical Society (ACS) in ACS Organic & Inorganic Au
- Vol. 4 (5) , 517-525
Open AccessFluorescence Labeling of Peptides: Finding the Optimal Protocol for Coupling Various Dyes to ATCUN-like Structures
Labeling of peptides and proteins with fluorescent dyes is a key step in functionalizing these structures for a wide array of biological assays. However, coupling strategies of such dyes have not been optimized for the most common compounds, while this step is typically the most precious and costly of the whole synthesis. We searched for the best conditions for attachment of the most widely used fluorescent dyes such as 6-carboxyfluorescein, Rhodamine B, and BODIPY-FL to peptides, where amino terminal Cu(II) and Ni(II) binding site (ATCUN) peptides were used as a model system. Surprisingly, conventional methods of dye attachment proved to not be satisfactory and yielded poor efficiency results. We have discovered that when labeling primary amines on peptides, the uncommon synthesis of activated pentafluorophenol (PFP) esters is the most efficient strategy, expedited by microwave irradiation. Coupling to secondary amines is achieved most efficiently through conventional coupling reagents such as HATU and PyBOP. Furthermore, we have employed our fluorescently labeled ATCUN peptides in studies for Cu(II) and Ni(II) sensing, showing that changing the fluorophore does not significantly affect the fluorescence quenching process and discovering the optimal linker length between the ATCUN core and the dye, expanding the repertoire of fluorophores that can be used in this application.
- Open Access
- 16 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (4) , 1565-1575
Luminescence Lifetime-Based Sensing Platform Based on Cyclometalated Iridium(III) Complexes for the Detection of Perfluorooctanoic Acid in Aqueous Samples
Luminescence lifetimes are an attractive analytical method for detection due to its high sensitivity and stability. Iridium probes exhibit luminescence with long excited-state lifetimes, which are sensitive to the local environment. Perfluorooctanoic acid (PFOA) is listed as a chemical of high concern regarding its toxicity and is classified as a "forever chemical". In addition to strict limits on the presence of PFOA in drinking water, environmental contamination from industrial effluent or chemical spills requires rapid, simple, accurate, and cost-effective analysis in order to aid containment. Herein, we report the fabrication and function of a novel and facile luminescence sensor for PFOA based on iridium modified on gold surfaces. These surfaces were modified with lipophilic iridium complexes bearing alkyl chains, namely, IrC6 and IrC12, and Zonyl-FSA surfactant. Upon addition of PFOA, the modified surfaces IrC6-FSA@Au and IrC12-FSA @Au show the largest change in the red luminescence signal with changes in the luminescence lifetime that allow monitoring of PFOA concentrations in aqueous solutions. The platform was tested for the measurement of PFOA in aqueous samples spiked with known concentrations of PFOA and demonstrated the capacity to determine PFOA at concentrations >100 μg/L (240 nM).
- 16 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (4) , 1565-1575
Open AccessLuminescence Lifetime-Based Sensing Platform Based on Cyclometalated Iridium(III) Complexes for the Detection of Perfluorooctanoic Acid in Aqueous Samples
Luminescence lifetimes are an attractive analytical method for detection due to its high sensitivity and stability. Iridium probes exhibit luminescence with long excited-state lifetimes, which are sensitive to the local environment. Perfluorooctanoic acid (PFOA) is listed as a chemical of high concern regarding its toxicity and is classified as a "forever chemical". In addition to strict limits on the presence of PFOA in drinking water, environmental contamination from industrial effluent or chemical spills requires rapid, simple, accurate, and cost-effective analysis in order to aid containment. Herein, we report the fabrication and function of a novel and facile luminescence sensor for PFOA based on iridium modified on gold surfaces. These surfaces were modified with lipophilic iridium complexes bearing alkyl chains, namely, IrC6 and IrC12, and Zonyl-FSA surfactant. Upon addition of PFOA, the modified surfaces IrC6-FSA@Au and IrC12-FSA @Au show the largest change in the red luminescence signal with changes in the luminescence lifetime that allow monitoring of PFOA concentrations in aqueous solutions. The platform was tested for the measurement of PFOA in aqueous samples spiked with known concentrations of PFOA and demonstrated the capacity to determine PFOA at concentrations >100 μg/L (240 nM).
- Top Cited PapersOpen Access
- 2 November 2022
- Published by Royal Society of Chemistry (RSC) in Energy & Environmental Science
- Vol. 15 (12) , 4982-5016
Recent advances in triplet–triplet annihilation upconversion and singlet fission, towards solar energy applications
Here we consolidate recent advances in the fields of triplet–triplet annihilation photon upconversion and singlet fission. We further describe their utility in increasing the efficiency of photovoltaic devices.
- 2 November 2022
- Published by Royal Society of Chemistry (RSC) in Energy & Environmental Science
- Vol. 15 (12) , 4982-5016
Top Cited PapersOpen AccessRecent advances in triplet–triplet annihilation upconversion and singlet fission, towards solar energy applications
Here we consolidate recent advances in the fields of triplet–triplet annihilation photon upconversion and singlet fission. We further describe their utility in increasing the efficiency of photovoltaic devices.
- Open Access
- 22 February 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (12) , 4923-4928
Modulating TTA efficiency through control of high energy triplet states
An ideal annihilator in triplet–triplet annihilation photon upconversion (TTA-UC) can achieve a maximum of 50% quantum efficiency. This spin statistical limit depends on the energies of the triplet states of the annihilator molecule, with only 20% quantum efficiencies possible in less-optimal energy configurations (E T2 ≤ 2E T1 ). Our work utilises three perylene analogues substituted with phenyl in sequential positions. When substituted in the bay position the isomer displays drastically lowered upconversion yields, which can be explained by the system going from an ideal to less-ideal energy configuration. We further concluded position 2 is the best site when functionalising perylene without a wish to affect its photophysics, thus demonstrating how molecular design can influence upconversion quantum efficiencies by controlling the energetics of triplet states through substitution. This will in turn help in the design of molecules that maximise upconversion efficiencies for materials applications.
- 22 February 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 10 (12) , 4923-4928
Open AccessModulating TTA efficiency through control of high energy triplet states
An ideal annihilator in triplet–triplet annihilation photon upconversion (TTA-UC) can achieve a maximum of 50% quantum efficiency. This spin statistical limit depends on the energies of the triplet states of the annihilator molecule, with only 20% quantum efficiencies possible in less-optimal energy configurations (E T2 ≤ 2E T1 ). Our work utilises three perylene analogues substituted with phenyl in sequential positions. When substituted in the bay position the isomer displays drastically lowered upconversion yields, which can be explained by the system going from an ideal to less-ideal energy configuration. We further concluded position 2 is the best site when functionalising perylene without a wish to affect its photophysics, thus demonstrating how molecular design can influence upconversion quantum efficiencies by controlling the energetics of triplet states through substitution. This will in turn help in the design of molecules that maximise upconversion efficiencies for materials applications.
- Open Access
- 21 July 2018
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 140 (32) , 10242-10249
Iridium Nanoparticles for Multichannel Luminescence Lifetime Imaging, Mapping Localization in Live Cancer Cells
The development of long-lived luminescent nanoparticles for lifetime imaging is of wide interest as luminescence lifetime is environmentally sensitive detection independent of probe concentration. We report novel iridium-coated gold nanoparticles as probes for multiphoton lifetime imaging with characteristic long luminescent lifetimes based on iridium luminescence in the range of hundreds of nanoseconds and a short signal on the scale of picoseconds based on gold allowing multichannel detection. The tailor made IrC6 complex forms stable, water soluble gold nanoparticles of 13, 25 and 100 nm, bearing 1400, 3200 and 22000 IrC6 complexes per AuNP, respectively. The sensitivity of the iridium signal on the environment of the cell is evidenced with an observed variation of lifetimes. Clusters of iridium nanoparticles show lifetimes from 450-590 ns whilst lifetimes of 660 ns and 740 ns are an average of different points in the cytoplasm and nucleus. Independent luminescence lifetime studies of the nanoparticles in different media and under aggregation conditions postulate that the unusual long lifetimes observed can be attributed to interaction with proteins rather than nanoparticle aggregation. TIRF. confocal microscopy studies and 3D luminescence lifetime stacks confirm the presence of bright, non-aggregated nanoparticles inside the cell. ICPMS analysis further supports the presence of the nanoparticles in cells. The iridium-coated nanoparticles provide new nanoprobes for lifetime detection with dual channel monitoring. The combination of the sensitivity of the iridium signal to the cell environment together with the nanoscaffold to guide delivery offer opportunities for iridium nanoparticles for targeting and tracking in in vivo models.
- 21 July 2018
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 140 (32) , 10242-10249
Open AccessIridium Nanoparticles for Multichannel Luminescence Lifetime Imaging, Mapping Localization in Live Cancer Cells
The development of long-lived luminescent nanoparticles for lifetime imaging is of wide interest as luminescence lifetime is environmentally sensitive detection independent of probe concentration. We report novel iridium-coated gold nanoparticles as probes for multiphoton lifetime imaging with characteristic long luminescent lifetimes based on iridium luminescence in the range of hundreds of nanoseconds and a short signal on the scale of picoseconds based on gold allowing multichannel detection. The tailor made IrC6 complex forms stable, water soluble gold nanoparticles of 13, 25 and 100 nm, bearing 1400, 3200 and 22000 IrC6 complexes per AuNP, respectively. The sensitivity of the iridium signal on the environment of the cell is evidenced with an observed variation of lifetimes. Clusters of iridium nanoparticles show lifetimes from 450-590 ns whilst lifetimes of 660 ns and 740 ns are an average of different points in the cytoplasm and nucleus. Independent luminescence lifetime studies of the nanoparticles in different media and under aggregation conditions postulate that the unusual long lifetimes observed can be attributed to interaction with proteins rather than nanoparticle aggregation. TIRF. confocal microscopy studies and 3D luminescence lifetime stacks confirm the presence of bright, non-aggregated nanoparticles inside the cell. ICPMS analysis further supports the presence of the nanoparticles in cells. The iridium-coated nanoparticles provide new nanoprobes for lifetime detection with dual channel monitoring. The combination of the sensitivity of the iridium signal to the cell environment together with the nanoscaffold to guide delivery offer opportunities for iridium nanoparticles for targeting and tracking in in vivo models.
- 22 March 2018
- Published by Wiley in ChemistrySelect
- Vol. 3 (11) , 3251-3257
Surfactant‐Enhanced Luminescence Lifetime for Biomolecular Detection on Luminescent Gold Surfaces Decorated with Transition Metal Complexes
In the development of sensors based on multimodal detection, luminescent probes are attractive for providing a sensitive signal read‐out, based either on intensity, wavelength shift or luminescence lifetime. The implicit simplicity of the devices that can be created is dependent of the judicious design of the multimodal probe. We have used transition metal probes which offer combined versatility due to their electroactive and photoluminescent properties, as well as their sensitivity to local environment. We report the influence of surfactant upon the formation of luminescent surfaces with metal complexes based on ruthenium(II), iridium(III) and osmium(II) bearing surface active groups. The results reveal an enhancement of the luminescence lifetime when a mixed monolayer with surfactant is formed. Characteristically, the luminescence lifetime of the ruthenium tris‐bipyridyl complex attached to the gold surface increases from 210 ns to 765 ns in the presence of a fluorinated surfactant. The luminescence signal of the modified gold surfaces is also responsive to bovine serum albumin and fetal bovine serum adsorption, demonstrating interaction of the protein with the metal complex in the presence of the surfactant. The biomolecular interaction with the functionalised surfaces is also evidenced by surface plasmon resonance response.
- 22 March 2018
- Published by Wiley in ChemistrySelect
- Vol. 3 (11) , 3251-3257
Surfactant‐Enhanced Luminescence Lifetime for Biomolecular Detection on Luminescent Gold Surfaces Decorated with Transition Metal Complexes
In the development of sensors based on multimodal detection, luminescent probes are attractive for providing a sensitive signal read‐out, based either on intensity, wavelength shift or luminescence lifetime. The implicit simplicity of the devices that can be created is dependent of the judicious design of the multimodal probe. We have used transition metal probes which offer combined versatility due to their electroactive and photoluminescent properties, as well as their sensitivity to local environment. We report the influence of surfactant upon the formation of luminescent surfaces with metal complexes based on ruthenium(II), iridium(III) and osmium(II) bearing surface active groups. The results reveal an enhancement of the luminescence lifetime when a mixed monolayer with surfactant is formed. Characteristically, the luminescence lifetime of the ruthenium tris‐bipyridyl complex attached to the gold surface increases from 210 ns to 765 ns in the presence of a fluorinated surfactant. The luminescence signal of the modified gold surfaces is also responsive to bovine serum albumin and fetal bovine serum adsorption, demonstrating interaction of the protein with the metal complex in the presence of the surfactant. The biomolecular interaction with the functionalised surfaces is also evidenced by surface plasmon resonance response.