Maria Lorena Fiorentino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Lorena Fiorentino has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Marcello Imbriani
University of Pavia
4 shared publications - Cristina Sottani
Environmental Research Center, Istituti Clinici Scientifici Maugeri IRCCS, 27100 Pavia, Italy
3 shared publications A. Berri
Laboratory of Environmental Hygiene and Industrial Toxicology, ‘S. Maugeri’ Foundation, IRCCS, Via Alzaia 29, Pavia 27100, Italy
2 shared publicationsC. Minoia
Laboratory of Environmental Hygiene and Industrial Toxicology, S. Maugeri Foundation, IRCCS, Pavia, Italy
2 shared publicationsClaudio Minoia
Laboratory of Environmental Hygiene and Industrial Toxicology, S. Maugeri Foundation, via Ferrata 8, Pavia, Italy
2 shared publications- Giuseppina Micoli
Centro di Ricerche Ambientali, IRCCS Fondazione Salvatore Maugeri, via Salvatore Maugeri 10, Pavia, Italy
2 shared publications
Latest Publications
- 19 September 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (20) , 2253-2259
Analytical method for the quantitative determination of urinary ethylenethiourea by liquid chromatography/electrospray ionization tandem mass spectrometry
A direct, rapid and selective method for the quantitative determination of the ethylenethiourea (ETU) in human urine has been validated and is reported in the present study. It allows the accurate quantification of ETU in this complex matrix without the use of any internal standard as the sample cleanup is effective enough for the removal of interferences that could lead to ion suppression in the electrospray ionization (ESI) source. This simple and rapid purification system, based on the use of a Fluorosil phase of a BondElut® column followed by a liquid‐liquid extraction procedure, achieves mean extracted recoveries, assessed at three different concentrations (2.5, 10.0, and 25.0 μg/L), always more than 85%. High‐performance liquid chromatography (HPLC) with positive ion tandem mass spectrometry, operating in selected multiple reaction monitoring (MRM) mode, is used to quantify ETU in human urine. The assay is linear over the range 0–50 μg/L, with a lower limit of quantification (LOQ) of 1.5 μg/L and a coefficient of variation (CV) of 8.9%. The lower limit of detection (LOD) is assessed at 0.5 μg/L. The overall precision and accuracy were determined on three different days. The values for within‐ and between‐day precision are ≤ 8.3 and 10.1%, respectively, and the accuracy is in the range 97–118%. The relative uncertainties for the LOQ and QC concentrations have been estimated to be 18 and 8%, respectively. The assay was applied to quantify ETU in human urine from growers that regularly handle ethylenebisdithiocarbamate pesticides in large crop plantations. The biological samples were collected at the start and end of the working day, and the ETU urine levels were found to vary between 1.9 and 8.2 μg/L. Copyright © 2003 John Wiley & Sons, Ltd.
- 19 September 2003
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (20) , 2253-2259
Analytical method for the quantitative determination of urinary ethylenethiourea by liquid chromatography/electrospray ionization tandem mass spectrometry
A direct, rapid and selective method for the quantitative determination of the ethylenethiourea (ETU) in human urine has been validated and is reported in the present study. It allows the accurate quantification of ETU in this complex matrix without the use of any internal standard as the sample cleanup is effective enough for the removal of interferences that could lead to ion suppression in the electrospray ionization (ESI) source. This simple and rapid purification system, based on the use of a Fluorosil phase of a BondElut® column followed by a liquid‐liquid extraction procedure, achieves mean extracted recoveries, assessed at three different concentrations (2.5, 10.0, and 25.0 μg/L), always more than 85%. High‐performance liquid chromatography (HPLC) with positive ion tandem mass spectrometry, operating in selected multiple reaction monitoring (MRM) mode, is used to quantify ETU in human urine. The assay is linear over the range 0–50 μg/L, with a lower limit of quantification (LOQ) of 1.5 μg/L and a coefficient of variation (CV) of 8.9%. The lower limit of detection (LOD) is assessed at 0.5 μg/L. The overall precision and accuracy were determined on three different days. The values for within‐ and between‐day precision are ≤ 8.3 and 10.1%, respectively, and the accuracy is in the range 97–118%. The relative uncertainties for the LOQ and QC concentrations have been estimated to be 18 and 8%, respectively. The assay was applied to quantify ETU in human urine from growers that regularly handle ethylenebisdithiocarbamate pesticides in large crop plantations. The biological samples were collected at the start and end of the working day, and the ETU urine levels were found to vary between 1.9 and 8.2 μg/L. Copyright © 2003 John Wiley & Sons, Ltd.
- 22 May 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (10) , 930-935
Rapid and sensitive determination of paclitaxel (Taxol®) in environmental samples by high‐performance liquid chromatography tandem mass spectrometry
- 22 May 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (10) , 930-935
Rapid and sensitive determination of paclitaxel (Taxol®) in environmental samples by high‐performance liquid chromatography tandem mass spectrometry
- 1 March 1999
- Published by Elsevier in Journal of Chromatography B: Biomedical Sciences and Applications
- Vol. 724 (2) , 257-264
Matrix interferences in the analysis of benzene in urine
- 1 March 1999
- Published by Elsevier in Journal of Chromatography B: Biomedical Sciences and Applications
- Vol. 724 (2) , 257-264
Matrix interferences in the analysis of benzene in urine
- 1 May 1997
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 11 (8) , 907-913
Matrix Performance in Matrix-assisted Laser Desorption/Ionization for Molecular Weight Determination in Sialyl and Non-sialyl Oligosaccharide Proteins
- 1 May 1997
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 11 (8) , 907-913
Matrix Performance in Matrix-assisted Laser Desorption/Ionization for Molecular Weight Determination in Sialyl and Non-sialyl Oligosaccharide Proteins
- 1 May 1997
- Published by Elsevier in Science of The Total Environment
- Vol. 198 (1) , 33-41
Determination of environmental reference concentration of six PAHs in urban areas (Pavia, Italy)
- 1 May 1997
- Published by Elsevier in Science of The Total Environment
- Vol. 198 (1) , 33-41
Determination of environmental reference concentration of six PAHs in urban areas (Pavia, Italy)
- 1 December 1996
- Published by Elsevier in Science of The Total Environment
- Vol. 192 (2) , 163-182
Environmental and urinary reference values as markers of exposure to hydrocarbons in urban areas
- 1 December 1996
- Published by Elsevier in Science of The Total Environment
- Vol. 192 (2) , 163-182
Environmental and urinary reference values as markers of exposure to hydrocarbons in urban areas
- 1 March 1996
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 11 (3) , 187-192
The Determination of Trans, Trans-Muconic Acid in Urine as an Indicator of Occupational Exposure to Benzene
Recently the determination of muconic acid (MA; milligrams/gram creatinine) in urine has been proposed as a suitable biomarker for the monitoring of low level exposure to benzene. A sample of 171 subjects employed in a factory was studied for personal exposure to benzene [CI, benzene (parts per million)] and excretion of AM. The 8-hour time-weighted exposure intensity of individual workers was monitored by means of charcoal tubes. MA excretion level in urine was determined by high performance liquid chromatography with ultraviolet detection. The following linear correlation was found between MA concentrations in urine and benzene concentrations in the breathing zone log MA(mg/g creatinine) = 0.549 log CI, benzene (ppm) – 0.18 (n = 171, r = 0.614, p < 0.0001) MA concentrations in urine from 100 nonexposed subjects (50 smokers >20 cigarettes/day and 50 nonsmokers) were also determined [geometric mean of 0.207 mg/g creatinine (1.5) and 0.067 mg/g creatinine (2.1), respectively]. In the current study, the levels of MA in smokers were about three times higher than those in nonsmokers. The study results indicate that the urinary level of MA can be regarded as a useful indicator of occupational exposure to benzene.
- 1 March 1996
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 11 (3) , 187-192
The Determination of Trans, Trans-Muconic Acid in Urine as an Indicator of Occupational Exposure to Benzene
Recently the determination of muconic acid (MA; milligrams/gram creatinine) in urine has been proposed as a suitable biomarker for the monitoring of low level exposure to benzene. A sample of 171 subjects employed in a factory was studied for personal exposure to benzene [CI, benzene (parts per million)] and excretion of AM. The 8-hour time-weighted exposure intensity of individual workers was monitored by means of charcoal tubes. MA excretion level in urine was determined by high performance liquid chromatography with ultraviolet detection. The following linear correlation was found between MA concentrations in urine and benzene concentrations in the breathing zone log MA(mg/g creatinine) = 0.549 log CI, benzene (ppm) – 0.18 (n = 171, r = 0.614, p < 0.0001) MA concentrations in urine from 100 nonexposed subjects (50 smokers >20 cigarettes/day and 50 nonsmokers) were also determined [geometric mean of 0.207 mg/g creatinine (1.5) and 0.067 mg/g creatinine (2.1), respectively]. In the current study, the levels of MA in smokers were about three times higher than those in nonsmokers. The study results indicate that the urinary level of MA can be regarded as a useful indicator of occupational exposure to benzene.
- 1 May 1995
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 67 (3) , 195-200
Evaluation of occupational exposure to benzene by urinalysis
Urinary phenol determinations have traditionally been used to monitor high levels of occupational benzene exposure. However, urinary phenol cannot be used to monitor low-level exposures. New biological indexes for exposure to low levels of benzene are thus needed. The aim of this study was to investigate the relations between exposure to benzene (Abenzene, ppm), as measured by personal air sampling, and the excretion of benzene (U-benzene, ng/l),trans,trans-muconic acid (MA, mg/g creatinine), andS-phenylmercapturic acid (PMA, μg/g creatinine) in urine. The subjects of the study were 145 workers exposed to benzene in a chemical plant. The geometric mean exposure level was 0.1 ppm (geometric standard deviation = 4.16). After logarithmic transformation of the data the following linear regressions were found: log (U-benzene, ng/l) = 0.681 log (A-benzene ppm) + 4.018; log (MA, mg/g creatinine) = 0.429 log (A-benzen ppm) − 0.304; and log (PMA, μg/g creatinine) = 0.712 log (A-benzene ppm) + 1.664. The correlation coefficients were, respectively, 0.66, 0.58, and 0.74. On the basis of the equations it was possible to establish tentative biological limit values corresponding to the respective occupational exposure limit values. In conclusion, the concentrations of benzene, mercapturic acid, and muconic acid in urine proved to be good parameters for monitoring low benzene exposure at the workplace.
- 1 May 1995
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 67 (3) , 195-200
Evaluation of occupational exposure to benzene by urinalysis
Urinary phenol determinations have traditionally been used to monitor high levels of occupational benzene exposure. However, urinary phenol cannot be used to monitor low-level exposures. New biological indexes for exposure to low levels of benzene are thus needed. The aim of this study was to investigate the relations between exposure to benzene (Abenzene, ppm), as measured by personal air sampling, and the excretion of benzene (U-benzene, ng/l),trans,trans-muconic acid (MA, mg/g creatinine), andS-phenylmercapturic acid (PMA, μg/g creatinine) in urine. The subjects of the study were 145 workers exposed to benzene in a chemical plant. The geometric mean exposure level was 0.1 ppm (geometric standard deviation = 4.16). After logarithmic transformation of the data the following linear regressions were found: log (U-benzene, ng/l) = 0.681 log (A-benzene ppm) + 4.018; log (MA, mg/g creatinine) = 0.429 log (A-benzen ppm) − 0.304; and log (PMA, μg/g creatinine) = 0.712 log (A-benzene ppm) + 1.664. The correlation coefficients were, respectively, 0.66, 0.58, and 0.74. On the basis of the equations it was possible to establish tentative biological limit values corresponding to the respective occupational exposure limit values. In conclusion, the concentrations of benzene, mercapturic acid, and muconic acid in urine proved to be good parameters for monitoring low benzene exposure at the workplace.
- 1 April 1993
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 8 (4) , 283-287
An Evaluation of a New Portable Multi-Gas Monitor
Reliable direct-reading instruments are valuable tools in responding to emergency situations in a timely fashion. Moreover, they enable field industrial hygienists interested in screening workplaces to determine whether more extensive monitoring is necessary. The Brüel-Kjaer 1302 Multi-Gas Monitor (MGM), a new, portable photo-acoustic analyzer, was evaluated in the laboratory and in the field monitoring different chemicals (nitrous oxide and Forane). Instrument performance was evaluated by comparing results obtained using the MGM with data obtained using a gas chromatograph connected to a mass selective detector and personal passive samplers. The correlation between data obtained using both methods was excellent. Effects of instrument resolution and sample storage stability were investigated. The linear range of the MGM is more than adequate for the sample concentrations determined in this study. Some advantages of the MGM include ease of programming and calibrating, minimal training or supervision for field use, and instantaneous detection of accurate and specific information about a work environment. Ghittori, S.; Fiorentino, M.L.; Imbriani, M.: An Evaluation of a New Portable Multi-Gas Monitor. Appl. Occup. Environ. Hyg. 8(4):283-287; 1993.
- 1 April 1993
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 8 (4) , 283-287
An Evaluation of a New Portable Multi-Gas Monitor
Reliable direct-reading instruments are valuable tools in responding to emergency situations in a timely fashion. Moreover, they enable field industrial hygienists interested in screening workplaces to determine whether more extensive monitoring is necessary. The Brüel-Kjaer 1302 Multi-Gas Monitor (MGM), a new, portable photo-acoustic analyzer, was evaluated in the laboratory and in the field monitoring different chemicals (nitrous oxide and Forane). Instrument performance was evaluated by comparing results obtained using the MGM with data obtained using a gas chromatograph connected to a mass selective detector and personal passive samplers. The correlation between data obtained using both methods was excellent. Effects of instrument resolution and sample storage stability were investigated. The linear range of the MGM is more than adequate for the sample concentrations determined in this study. Some advantages of the MGM include ease of programming and calibrating, minimal training or supervision for field use, and instantaneous detection of accurate and specific information about a work environment. Ghittori, S.; Fiorentino, M.L.; Imbriani, M.: An Evaluation of a New Portable Multi-Gas Monitor. Appl. Occup. Environ. Hyg. 8(4):283-287; 1993.
- 1 March 1993
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health
- Vol. 38 (3) , 233-243
Urinary excretion of unmetabolized benzene as an indicator of benzene exposure
Benzene concentrations in urine samples (Cu, ng/L) from 110 workers exposed to benzene in chemical plants and gasoline pumps were determined by injecting urine supernate into a gas chromatograph. The urine was saturated with anhydrous N2SO4 to facilitate the passage of benzene in the air over the urine. The solvent was stripped from the urine surface and concentrated on an adsorbent substrate (Carbotrap tube) by means of a suction pump (flow rate 150 ml/m). Wash‐up of the head space was achieved by simultaneous intake of filtered air through charcoal. Benzene was thermi‐cally desorbed and injected in a column (thermal tube desorber, Supelco; 370°C thermal flash; borosilicate capillary glass column SPB‐1, 60 m length, 0.75 mm ID, 1 pm film thickness; GC Dani 8580‐FID). Benzene concentrations in the urine from 40 non‐exposed subjects (20 smokers > 20 cigarettes/d and 20 nonsmokers) were also determined [median value of 790 ng/L (10.17 nmol/L) and 131 ng/L (1.70 nmol/L), respectively]. The 8‐h time‐weighted exposure intensity (Cl, ng/m3) of individual workers was monitored by means of charcoal tubes. The median value for exposure to benzene was 736 ng/m3 (9.42 μmol/m3) [geometric standard deviation (CSD) ‐ 2.99; range 64 μg/m3 (0.82 μmol/m3) to 13,387 μg/m3) (171.30 μmol/m3)]. The following linear correlation was found between benzene concentrations in urine (Cu, ng/L) and benzene concentrations in the breathing zone (Cl, μg/m3): log(Cu) = 0.645 × log(Cl) + 1.399 r ‐ .559, n = 110, p < .0007 With exclusion of workers who smoked from the study, the correlation between air benzene concentration and benzene measured in urine was: log(Cu) = 0.872 × log(Cl) + 0.6 r = .763, n = 63, p < .0007 The study results indicate that the urinary level of benzene is an indicator of occupational exposure to benzene.
- 1 March 1993
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health
- Vol. 38 (3) , 233-243
Urinary excretion of unmetabolized benzene as an indicator of benzene exposure
Benzene concentrations in urine samples (Cu, ng/L) from 110 workers exposed to benzene in chemical plants and gasoline pumps were determined by injecting urine supernate into a gas chromatograph. The urine was saturated with anhydrous N2SO4 to facilitate the passage of benzene in the air over the urine. The solvent was stripped from the urine surface and concentrated on an adsorbent substrate (Carbotrap tube) by means of a suction pump (flow rate 150 ml/m). Wash‐up of the head space was achieved by simultaneous intake of filtered air through charcoal. Benzene was thermi‐cally desorbed and injected in a column (thermal tube desorber, Supelco; 370°C thermal flash; borosilicate capillary glass column SPB‐1, 60 m length, 0.75 mm ID, 1 pm film thickness; GC Dani 8580‐FID). Benzene concentrations in the urine from 40 non‐exposed subjects (20 smokers > 20 cigarettes/d and 20 nonsmokers) were also determined [median value of 790 ng/L (10.17 nmol/L) and 131 ng/L (1.70 nmol/L), respectively]. The 8‐h time‐weighted exposure intensity (Cl, ng/m3) of individual workers was monitored by means of charcoal tubes. The median value for exposure to benzene was 736 ng/m3 (9.42 μmol/m3) [geometric standard deviation (CSD) ‐ 2.99; range 64 μg/m3 (0.82 μmol/m3) to 13,387 μg/m3) (171.30 μmol/m3)]. The following linear correlation was found between benzene concentrations in urine (Cu, ng/L) and benzene concentrations in the breathing zone (Cl, μg/m3): log(Cu) = 0.645 × log(Cl) + 1.399 r ‐ .559, n = 110, p < .0007 With exclusion of workers who smoked from the study, the correlation between air benzene concentration and benzene measured in urine was: log(Cu) = 0.872 × log(Cl) + 0.6 r = .763, n = 63, p < .0007 The study results indicate that the urinary level of benzene is an indicator of occupational exposure to benzene.