Flávia Manente da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Flávia Manente da Silva has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Eduardo Eyng
2 shared publications- Eduardo Eyng
Program in Environmental Technologies Federal University of Technology – Paraná Medianeira Brazil
2 shared publications Fábio Orssatto
Universidade Tecnológica Federal do Paraná - Medianeira - Paraná - Brasil
2 shared publications- Fábio Orssatto
Departamento Acadêmico de Ciências Ambientais e Biológicas. Programa de Pós Graduação em Tecnologias Ambientais. Universidade Tecnológica Federal do Paraná (UTFPR), Câmpus Medianeira, Avenida Brasil, n° 4232, CEP: 85722-332, Medianeira, PR, Brazil
2 shared publications Laercio Mantovani Frare
Universidade Tecnológica Federal do Paraná - Medianeira - Paraná - Brasil
2 shared publicationsLeandro Fleck
2 shared publications
Latest Publications
- Open Access
- 20 December 2022
- Published by Revista DAE in Revista DAE
- Vol. 71 (239) , 31-45
Otimização do tratamento de efluente de abatedouro e frigorífico por meio de eletrofloculação em reator de fluxo contínuo
O objetivo desse trabalho foi avaliar a eficiência da técnica eletroquímica no tratamento de efluente de abatedouro e frigorífico de suínos por meio da análise das remoções da DQO, turbidez, cor e NTK, além de otimizar as variáveis corrente elétrica e tempo de detenção hidráulica (TDH) em um reator de fluxo contínuo de eletrofloculação. O sistema de tratamento em fluxo contínuo de bancada consistiu em um reator com volume de 1,6 L acoplado a um defletor com volume de 3,12 L; os eletrodos de alumínio foram acomodados no reator e conectados a uma fonte de corrente contínua. O efluente a ser tratado era bombeado para o reator, onde ocorriam as reações eletroquímicas e na sequência era direcionado para o defletor. Os testes seguiram um delineamento composto central rotacional, com duas variáveis independentes (corrente elétrica e TDH). As maiores remoções para a cor, turbidez, DQO e NTK foram 91,76%, 74,47%, 61,97% e 20%, respectivamente. Foi possível obter modelos matemáticos válidos para a remoção dos parâmetros analisados e, ao se calcular a função da desejabilidade, o resultado das condições otimizadas de tratamento foi de 18 min para o TDH e 1,5 A para a corrente elétrica, o que corresponde a uma densidade de corrente igual a 16,67 mA cm-2. O alumínio residual variou de 1,21 a 4,61 mg L-1 e o custo do tratamento ficou em 4,47 R$ m-3. Palavras-chave: Eletrocoagulação. Tratamento Eletrolítico. Tratamento Físico-químico. Águas Residuárias.
- 20 December 2022
- Published by Revista DAE in Revista DAE
- Vol. 71 (239) , 31-45
Open AccessOtimização do tratamento de efluente de abatedouro e frigorífico por meio de eletrofloculação em reator de fluxo contínuo
O objetivo desse trabalho foi avaliar a eficiência da técnica eletroquímica no tratamento de efluente de abatedouro e frigorífico de suínos por meio da análise das remoções da DQO, turbidez, cor e NTK, além de otimizar as variáveis corrente elétrica e tempo de detenção hidráulica (TDH) em um reator de fluxo contínuo de eletrofloculação. O sistema de tratamento em fluxo contínuo de bancada consistiu em um reator com volume de 1,6 L acoplado a um defletor com volume de 3,12 L; os eletrodos de alumínio foram acomodados no reator e conectados a uma fonte de corrente contínua. O efluente a ser tratado era bombeado para o reator, onde ocorriam as reações eletroquímicas e na sequência era direcionado para o defletor. Os testes seguiram um delineamento composto central rotacional, com duas variáveis independentes (corrente elétrica e TDH). As maiores remoções para a cor, turbidez, DQO e NTK foram 91,76%, 74,47%, 61,97% e 20%, respectivamente. Foi possível obter modelos matemáticos válidos para a remoção dos parâmetros analisados e, ao se calcular a função da desejabilidade, o resultado das condições otimizadas de tratamento foi de 18 min para o TDH e 1,5 A para a corrente elétrica, o que corresponde a uma densidade de corrente igual a 16,67 mA cm-2. O alumínio residual variou de 1,21 a 4,61 mg L-1 e o custo do tratamento ficou em 4,47 R$ m-3. Palavras-chave: Eletrocoagulação. Tratamento Eletrolítico. Tratamento Físico-químico. Águas Residuárias.
- 20 September 2018
- Published by Instituto de Pesquisas Ambientais em Bacias Hidrograficas (IPABHi) in Ambiente e Agua - An Interdisciplinary Journal of Applied Science
- Vol. 13 (5) , 1-10
Optimization of nitrogen and phosphorus removal from pig slaughterhouse and packing plant wastewater through electrocoagulation in a batch reactor
This work evaluated the removal of total Kjeldahl nitrogen (TKN) and total phosphorus (P) through electrocoagulation and used aluminum electrodes to optimize the potential differential (pd) and hydraulic retention time (HRT) variables in a batch reactor. The experimental design used was Rotatable Central Composite Design (RCCD). The application of the electrocoagulation in the treatment of effluents from pig slaughterhouses and packing plants proved to be efficient in relation to the removal of TKN and total phosphorus, obtaining maximum efficiency equal to 67.15% and 99%, respectively. The maximum TKN removal value was found in Test 12, where treatment conditions were 30 minutes for HRT and 20 volts for pd, which corresponds to 0.86 A of electric current and a current density of 17.2 mA cm-2. For P, the only test that removed below 99% was the first. Through statistical analyses, it was only possible to obtain a mathematical model for TKN removal. While the response surface graph did not present a defined range of the best conditions for the independent variables, it was possible to observe the tendency for better removal, a wide range of pd and values over 30 minutes for retention time.
- 20 September 2018
- Published by Instituto de Pesquisas Ambientais em Bacias Hidrograficas (IPABHi) in Ambiente e Agua - An Interdisciplinary Journal of Applied Science
- Vol. 13 (5) , 1-10
Optimization of nitrogen and phosphorus removal from pig slaughterhouse and packing plant wastewater through electrocoagulation in a batch reactor
This work evaluated the removal of total Kjeldahl nitrogen (TKN) and total phosphorus (P) through electrocoagulation and used aluminum electrodes to optimize the potential differential (pd) and hydraulic retention time (HRT) variables in a batch reactor. The experimental design used was Rotatable Central Composite Design (RCCD). The application of the electrocoagulation in the treatment of effluents from pig slaughterhouses and packing plants proved to be efficient in relation to the removal of TKN and total phosphorus, obtaining maximum efficiency equal to 67.15% and 99%, respectively. The maximum TKN removal value was found in Test 12, where treatment conditions were 30 minutes for HRT and 20 volts for pd, which corresponds to 0.86 A of electric current and a current density of 17.2 mA cm-2. For P, the only test that removed below 99% was the first. Through statistical analyses, it was only possible to obtain a mathematical model for TKN removal. While the response surface graph did not present a defined range of the best conditions for the independent variables, it was possible to observe the tendency for better removal, a wide range of pd and values over 30 minutes for retention time.
- Open Access
- 1 January 2018
- Published by Elsevier in Desalination and Water Treatment
- Vol. 102, 82-92
Optimization of the treatment of wastewater from a slaughterhouse and packing plant by the combination of electrocoagulation and tannin-based coagulant
- 1 January 2018
- Published by Elsevier in Desalination and Water Treatment
- Vol. 102, 82-92
Open AccessOptimization of the treatment of wastewater from a slaughterhouse and packing plant by the combination of electrocoagulation and tannin-based coagulant
- 14 December 2016
- Published by Taylor & Francis in Environmental Technology
- Vol. 38 (19) , 2465-2475
Optimization of the pretreatment of wastewater from a slaughterhouse and packing plant through electrocoagulation in a batch reactor
The purpose of this study is to evaluate the removal of chemical oxygen demand (COD), turbidity and color of wastewater from a pig slaughterhouse and packing plant through the electrochemical technique and to optimize the ΔV (electric potential difference) and HRT (hydraulic retention time) variables in an electrocoagulation batch reactor using aluminum electrodes. The experimental design used was rotatable central composite design. For turbidity, the values for removal efficiency obtained varied from 92.85% to 99.28%; for color, they varied from 81.34% to 98.93% and for COD, they varied from 58.61% to 81.01%. The best optimized conditions of treatment were at 25 min for the HRT and 25 V for the ΔV, which correspond to electrical current of 1.08 A and a current density of 21.6 mA cm−2. The aluminum residue varied from 15.254 to 54.291 mg L−1 and the cost of the treatment was US$4.288 m−3. The novelty of the work was the simultaneous optimization of three response variables using the desirability function applied to the treatment of wastewater from slaughterhouses.
- 14 December 2016
- Published by Taylor & Francis in Environmental Technology
- Vol. 38 (19) , 2465-2475
Optimization of the pretreatment of wastewater from a slaughterhouse and packing plant through electrocoagulation in a batch reactor
The purpose of this study is to evaluate the removal of chemical oxygen demand (COD), turbidity and color of wastewater from a pig slaughterhouse and packing plant through the electrochemical technique and to optimize the ΔV (electric potential difference) and HRT (hydraulic retention time) variables in an electrocoagulation batch reactor using aluminum electrodes. The experimental design used was rotatable central composite design. For turbidity, the values for removal efficiency obtained varied from 92.85% to 99.28%; for color, they varied from 81.34% to 98.93% and for COD, they varied from 58.61% to 81.01%. The best optimized conditions of treatment were at 25 min for the HRT and 25 V for the ΔV, which correspond to electrical current of 1.08 A and a current density of 21.6 mA cm−2. The aluminum residue varied from 15.254 to 54.291 mg L−1 and the cost of the treatment was US$4.288 m−3. The novelty of the work was the simultaneous optimization of three response variables using the desirability function applied to the treatment of wastewater from slaughterhouses.