PSPaolo De Santis

Paolo De Santis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paolo De Santis has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thirty-Day Complications, Unplanned Hospital Encounters, and Mortality after Endosonography and/or Guided Bronchoscopy: A Prospective Study

    by Daniele Magnini, Giovanni Sotgiu, Giuseppe Bello, Mariangela Puci, Vanina Livi, Antonio Maria Dell’anna, Paolo De Santis, Ruben Dell’ariccia, Marta Viscuso, Maria Chiara Flore, et al.

    Background and objective: Limited data exist regarding the adverse events of advanced diagnostic bronchoscopy, with most of the available information derived from retrospective datasets that primarily focus on early complications. Methods: We conducted a 15-month prospective cohort study among consecutive patients undergoing endosonography and/or guided bronchoscopy under general anesthesia. We evaluated the 30-day incidence of severe complications, any complication, unplanned hospital encounters, and deaths. Additionally, we analyzed the time of onset (immediate, within 1 h of the procedure; early, 1 h–24 h; late, 24 h–30 days) and identified risk factors associated with these events. Results: Thirty-day data were available for 697 out of 701 (99.4%) enrolled patients, with 85.6% having suspected malignancy and multiple comorbidities (median Charlson Comorbidity Index (IQR): 4 (2–5)). Severe complications occurred in only 17 (2.4%) patients, but among them, 10 (58.8%) had unplanned hospital encounters and 2 (11.7%) died within 30 days. A significant proportion of procedure-related severe complications (8/17, 47.1%); unplanned hospital encounters (8/11, 72.7%); and the two deaths occurred days or weeks after the procedure. Low-dose attenuation in the biopsy site on computed tomography was independently associated with any complication (OR: 1.87; 95% CI 1.13–3.09); unplanned hospital encounters (OR: 2.17; 95% CI 1.10–4.30); and mortality (OR: 4.19; 95% CI 1.74–10.11). Conclusions: Severe complications arising from endosonography and guided bronchoscopy, although uncommon, have significant clinical consequences. A substantial proportion of adverse events occur days after the procedure, potentially going unnoticed and exerting a negative clinical impact if a proactive surveillance program is not implemented.


  • Open Access

    Incoherence between Systemic Hemodynamic and Microcirculatory Response to Fluid Challenge in Critically Ill Patients

    by Paolo De Santis, Chiara De Fazio, Federico Franchi, Ottavia Bond, Jean-Louis Vincent, Jacques Creteur, Fabio Silvio Taccone, Sabino Scolletta

    Background: The aim of the study was to assess the coherence between systemic hemodynamic and microcirculatory response to a fluid challenge (FC) in critically ill patients. Methods: We prospectively collected data in patients requiring a FC whilst cardiac index (CI) and microcirculation were monitored. The sublingual microcirculation was assessed using the incident dark field (IDF) CytoCam device (Braedius Medical, Huizen, The Netherlands). The proportion of small perfused vessels (PPV) was calculated. Fluid responders were defined by at least a 10% increase in CI during FC. Responders according to changes in microcirculation were defined by at least 10% increase in PPV at the end of FC. Cohen’s kappa coefficient was measured to assess the agreement to categorize patients as “responders” to FC according to CI and PPV. Results: A total of 41 FC were performed in 38 patients, after a median time of 1 (0–1) days after ICU admission. Most of the fluid challenges (39/41, 95%) were performed using crystalloids and the median total amount of fluid was 500 (500–500) mL. The main reasons for fluid challenge were oliguria (n = 22) and hypotension (n = 10). After FC, CI significantly increased in 24 (58%) cases; a total of 19 (46%) FCs resulted in an increase in PPV. Both CI and PPV increased in 13 responders and neither in 11; the coefficient of agreement was only 0.21. We found no correlation between absolute changes in CI and PPV after fluid challenge. Conclusions: The results of this heterogenous population of critically ill patients suggest incoherence in fluid responsiveness between systemic and microvascular hemodynamics; larger cohort prospective studies with adequate a priori sample size calculations are needed to confirm these findings.


  • Open Access

    Relationship between Microcirculatory Perfusion and Arterial Elastance: A Pilot Study

    by Ottavia Bond, Paolo De Santis, Enrica Iesu, Federico Franchi, Jean-Louis Vincent, Jacques Creteur, Fabio Silvio Taccone, Sabino Scolletta

    Background. Arterial elastance (Ea) represents the total afterload imposed on the left ventricle, and it is largely influenced by systemic vascular resistance (SVR). Although one can expect that Ea is influenced by peripheral endothelial function, no data are available to support it in patients. The aim of this study was to investigate the relationship between Ea, SVR, and microvascular perfusion in critically ill patients undergoing the fluid challenge (FC). Methods. A prospective study in patients receiving a fluid challenge. A pulse wave analysis system (MostCare, Vygon, France) was used to estimate Ea and an incident dark field (IDF) handheld device (Braedius Medical BV, The Netherlands) to evaluate the sublingual microcirculation. Microvascular perfusion was assessed using the proportion of small-perfused vessels (PPV). Relative changes in each variable were calculated before and after FC; fluid responsiveness was defined as an increase in the cardiac index by at least 10% from baseline. Results. We studied 20 patients requiring a fluid challenge (n=10 for hypotension; n=5 for oliguria; n=3 for lactate values greater than 2 mmol/l; n=2 for tachycardia), including 12 fluid responders. There was a strong correlation between Ea and SVR (r2 = 0.75; p<0.001) and only a weak correlation between Ea and PPV at baseline (r2 = 0.22; p=0.04). Ea decreased from 1.4 [1.2–1.6] to 1.2 [1.1–1.4] mmHg/mL (p=0.01), SVR from 1207 [1006–1373] to 1073 [997–1202] dyn ∗ s/cm5 (p=0.06), and PPV from 56 [51–64] % to 59 [47–73] % (p=0.25) after fluid challenge. Changes in Ea were significantly correlated with changes in SVR, but not with changes in PPV. Conclusions. The correlation between Ea and indexes of microvascular perfusion in the sublingual region is weak. The impact of microcirculatory perfusion on the arterial load is probably limited.


  • Capnography during cardiac arrest

    by Claudio Sandroni, Paolo De Santis, Sonia D’arrigo


  • Open Access

    Non-invasive ventilation in cardiogenic pulmonary edema

    by Giuseppe Bello, Paolo De Santis, Massimo Antonelli

    Cardiogenic pulmonary edema (CPE) is among the most common causes of acute respiratory failure (ARF) in the acute care setting and often requires ventilatory assistance. In patients with ARF due to CPE, use of non-invasive positive airway pressure can decrease the systemic venous return and the left ventricular (LV) afterload, thus reducing LV filling pressure and limiting pulmonary edema. In these patients, either non-invasive ventilation (NIV) or continuous positive airway pressure (CPAP) can improve vital signs and physiological parameters, decreasing the need for endotracheal intubation (ETI) and hospital mortality when compared to conventional oxygen therapy. Results on the use of NIV or CPAP in patients with CPE prior to hospitalization are not homogeneous among studies, hampering any conclusive recommendation regarding their role in the pre-hospital setting.


  • The potential role of auditory evoked potentials to assess prognosis in comatose survivors from cardiac arrest

    by Paolo De Santis, Irene Lamanna, Nicolas Mavroudakis, Benjamin Legros, Jean-Louis Vincent, Jacques Creteur, Fabio Silvio Taccone


    • 23 December 2014
      • Vol. 81  (11) , 1201-9

    Minimum alveolar concentration threshold of sevoflurane for postoperative dream recall.

    by P Aceto, V Perilli, C Lai, T Sacco, C Modesti, E Luca, P De Santis, L Sollazzi, M Antonelli

    Many factors affect postoperative dream recall, including patient characteristics, type of anesthesia, timing of postoperative interview and stress hormone secretion. Aims of the study were to determine whether Bispectral Index (BIS)-guided anesthesia might decrease sevoflurane minimum alveolar concentration (MAC) when compared with hemodynamically-guided anesthesia, and to search for a MAC threshold useful for preventing arousal, dream recall and implicit memory. One hundred thirty patients undergoing elective thyroidectomy were enrolled. Anesthesia was induced with propofol 2 mg kg(-1), fentanyl 3 mcg kg(-1) and cis-atracurium 0.15 mg kg(-1). For anesthesia maintenance, patients were randomly assigned to one of two groups: a BIS-guided group in which sevoflurane MAC was adjusted on the basis of BIS values, and a hemodynamic parameters (HP)-guided group in which MAC was adjusted based on HP. An auditory recording was presented to patients during anesthesia maintenance. Dream recall and explicit/implicit memory were investigated upon awakening and approximately after 24 h. Mean sevoflurane MAC during auditory presentation was similar in the two groups (0.85 ± 0.16 and 0.87 ± 0.17 [P = 0.53] in BIS-guided and HP-guided groups, respectively). Frequency of dream recall was similar in the two groups: 27% (N. = 17) in BIS-guided group, 18% (N. = 12) in HP-guided group, P = 0.37. In both groups, dream recall was less probable in patients anesthetized with MAC values ≥ 0.9 (area under ROC curve = 0.83, sensitivity = 90%, and specificity = 49%). BIS-guided anesthesia was not able to generate different MAC values compared to HP-guided anesthesia. Independent of the guide used for anesthesia, a sevoflurane MAC over 0.9 was required to prevent postoperative dream recall.


  • Sub-acute hydrocephalus in a patient with influenza A (H3N2) virus-related cerebellitis

    by Paolo De Santis, Giacomo Della Marca, Giuseppe Di Lella, Fabio Cavallaro


  • Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis

    by Claudio Sandroni, Fabio Cavallaro, Cristina Marano, Chiara Falcone, Paolo De Santis, Massimo Antonelli

    To systematically review the accuracy of the variation in pulse oxymetry plethysmographic waveform amplitude (∆POP) and the Pleth Variability Index (PVI) as predictors of fluid responsiveness in mechanically ventilated adults. MEDLINE, Scopus and the Cochrane Database of Systematic Reviews were screened for clinical studies in which the accuracy of ∆POP/PVI in predicting the hemodynamic response to a subsequent fluid bolus had been investigated. Random-effects meta-analysis was used to summarize the results. Data were stratified according to the amount of fluid bolus (large vs. small) and to the study index (∆POP vs. PVI). Ten studies in 233 patients were included in this meta-analysis. All patients were in normal sinus rhythm. The pooled area under the receiver operating characteristic curve (AUC) for identification of fluid responders was 0.85 [95 % confidence interval (CI) 0.79–0.92]. Pooled sensitivity and specificity were 0.80 (95 % CI 0.74–0.85) and 0.76 (0.68–0.82), respectively. No heterogeneity was found within studies with the same amount of fluid bolus, nor between studies on ∆POP and those on PVI. The AUC was significantly larger in studies with a large bolus amount than in those with a small bolus [0.92 (95 % CI 0.87–0.96) vs. 0.70 (0.62–0.79); p < 0.0001]. Sensitivity and specificity were also higher in studies with a large bolus [0.84 (95 % CI 0.77–0.90) vs. 0.72 (0.60–0.82) (small bolus), p = 0.08 and 0.86 (95 % CI 0.75–0.93) vs. 0.68 (0.56–0.77) (small bolus), p = 0.02], respectively. Based on our meta-analysis, we conclude that ∆POP and PVI are equally effective for predicting fluid responsiveness in ventilated adult patients in sinus rhythm. Prediction is more accurate when a large fluid bolus is administered.


  • Open Access

    Assessment and Prediction of Whole-body Vibration Exposure in Transport Truck Drivers

    by Rocco Nitti, Paolo DE Santis

    The European Directive 2002/44/EC on the minimum Health and Safety prescriptions regarding the exposure of workers to vibrations, was implemented in Italy through the Legislative Decree 187/2005, recently amended by the Legislative Decree 81/2008. The Decrees contain legal obligations and minimum requirements for the evaluation by direct measurement, which is the reference method, although not always appropriate or necessary, and by means of vibration data banks or information provided by equipment manufacturers. The values assessed must be representative of the actual working environment: in order to adapt assessed values to real working conditions it may be useful to adopt some statistical models. Statistically significant relationships were observed by means of a multiple linear regression on a limited set of measures on different models of trucks, in different operating conditions and settings: the relative influence of predictor variables was then assessed. Finally a short digression about the evolution of the suspension fitting has been made in order to briefly describe the historical context of WBV exposure level reduction and the state of the art of industrial vehicle comfort improvement technologies.