NZNehal Zehra

Nehal Zehra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nehal Zehra has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Advances in Smart Polymers-based Diagnostics Tools and Wearable Device Development

    by Nehal Zehra, Debika Barman, Moirangthem Anita Chanu, Himangshu Baishya, Tapashi Sarmah, Parameswar Krishnan Iyer

  • A Conjugated Polymer‐Based Portable Smartphone Platform for Sensitive and Point‐Of‐Care Detection of Monoamine Neurotransmitter

    by Nehal Zehra, Akhtar H. Malik, Retwik Parui, Sameer Hussain, Parameswar Krishnan Iyer

    The precise and effective detection of neurotransmitters (NTs) is crucial for clinical investigation of neuronal processes, and timely monitoring of NT‐related chronic diseases. However, sensitive detection of specific NT with unprecedented selectivity is highly challenging due to similarities in chemical and electronic structures of various interfering neurochemicals. Herein, an anionic conjugated polyelectrolyte Poly[(9,9‐bis(4’‐sulfonatobutyl)fluorene‐co‐alt‐1,4‐phenylene) sodium], PFPS was rationally designed and synthesized for amplified detection and point‐of‐care (PoC) determination of monoamine neurotransmitter, serotonin (5‐Hydroxy tryptamine or 5‐HT, also diagnostic biomarker of carcinoid tumor) in human blood plasma. The PFPS displayed a remarkable sensing response with an exceptionally high fluorescence quenching constant of 1.14×105 M−1 and an ultralow detection limit of 0.67 μM or 0.142 ppm, much below the clinical range. Furthermore, a smartphone‐enabled portable platform was constructed for real‐time onsite detection of 5‐HT by quantification of visual fluorescence response of PFPS into RGB values using a color recognizer android application. The smartphone platform could be readily applied for convenient, non‐invasive PoC testing of 5‐HT levels in complex biological fluids accurately and is expected to revolutionize clinical diagnosis and personalized health care devices.


  • Imidazolium Functionalized Polyelectrolyte Assisted Perovskite Crystallization for Efficient and Stable Perovskite Solar Cells

    by Mayur Jagdishbhai Patel, Himangshu Baishya, Sushant Sharma, Nehal Zehra, Maimur Hossain, Ramkrishna Das Adhikari, Parameswar Krishnan Iyer


  • Conjugated Polymer Nanoparticles as a Fluorescence Probe for Amplified Detection of Human Serum Bilirubin

    by Moirangthem Anita Chanu, Subrata Mondal, Nehal Zehra, Arvin Sain Tanwar, Parameswar Krishnan Iyer


  • Advances in conjugated polymers for visualization of latent fingerprints: a critical perspective

    by Akhtar Hussain Malik, Nehal Zehra, Muzaffer Ahmad, Retwik Parui, Parameswar Krishnan Iyer

    This article provides an elaborate discussion of reports involving the development of latent fingerprints (LFPs) over the past decades with specific emphasis on the contribution of conjugated polymers (CPs) in the field of forensic science. CPs have been explored in the field of interdisciplinary sciences due to their widespread applications in the fields of imaging, chemical and biological sensors, electronic device, cancer therapeutics, etc. Even in the field of forensic sciences, these CP materials are in a continuous race with the existing technology and newer materials for the detection of fingerprint marks on various surfaces thus assisting in the unravelling of the precise identification of an individual suspect in modern criminology. Due to their excellent photophysical and chemical properties such as low toxicity, ease of functionalization, strong fluorescence emission, high quantum yield, and good optical stability, these CPs can lead to high resolution, and increased sensitivity and selectivity in the imaging of LFPs compared to those developed by traditional tedious methods. In this perspective, the challenges faced for LFP development and the role of various CPs including conjugated polyelectrolytes, polymer dots, and polymer nanoparticles are elaborately explained, thus, providing a systematic overview on techniques based on CPs as contrasting agents in the development of LFPs on various porous and nonporous substrates. There are various challenges pertaining to the development of LFPs on a multitude of surfaces which can be addressed by exploring materials with a suitable hydrophobic–hydrophilic balance and a receptor site for specific interactions with fingerprint components. The incorporation of this design principle has successfully led to the development of efficient platforms for rapid, onsite, intricate and unique LFP patterns on every kind of surface.


  • Wearable Sensing Devices for Point of Care Diagnostics

    by Subrata Mondal, Nehal Zehra, Anwesha Choudhury, Parameswar Krishnan Iyer

    The growth of smart wearable sensing systems has gained immense importance in the present mode of data acquisition and signaling in pharmaceutical, healthcare, and wellness industries. Presently, application of smart wearables is gaining prominence in several fitness activities, therapeutics, and diagnostic areas. Smart wearable biosensors offer real-time monitoring of physiological metrics and biomarkers that are specific to certain diseases in ambulant condition. This review offers a broad overview of the state-of-the-art progress on smart wearable biosensors focusing on applications in point of care diagnostics. A careful comparison of presently available commercial devices, implementation in clinical trials, and validation also have been highlighted in the present review. This work concludes with challenges and future prospects for scientists and engineers working in the nascent interdisciplinary field.


  • Conjugated Polymer-Based Electrical Sensor for Ultratrace Vapor-Phase Detection of Nerve Agent Mimics

    by Nehal Zehra, Anamika Kalita, Akhtar Hussain Malik, Ujjwol Barman, Mohammad Adil Afroz, Parameswar Krishnan Iyer

    Considering the vital need to strengthen the national security emanating from chemical threats, a low-cost, portable ultra-sensitive electrical sensor for real-time monitoring of Diethylchlorophosphate (DCP) (nerve gas mimic) has been developed. The device consists of “simple to be fabricated” two-terminal resistor and an electronic combinational circuit for rapid onsite detection of lethal nerve gas vapors with high degree of accuracy in milliseconds. This device is a smart readout electronic model that detects ultra-trace DCP vapors by bright visual alerts from LED and loud alarm signal without the need for employing a sophisticated instrument. To obtain high sensitivity and discriminating response, a novel amine-functionalized Conjugated Polymer (CP) is designed as a sensory channel material for two-terminal sensor. The low powered Poly(3-(9,9-dioctyl-9H-fluoren-2-yl)benzene-1,2-diamine) (PFPDA) fabricated two-terminal electrical sensor is tested at ambient conditions, which shows excellent sensitivity towards nerve gas mimic DCP, with rapid response in 3 sec and very low limit of detection (LOD) of 5.88 ppb. The amine moiety of PFPDA CP plays a vital role in redox interaction between the semiconductor CP and organophosphates, which ultimately leads to the amplified current signal. The redox interactions occurring among the organophosphate analytes and the amine functional group on the PFPDA backbone provided insights into the mechanism of sensing which formed the basis of excellent sensitivity and discriminating ability of this sensor device. The newly designed PFPDA CP-based portable electrical sensor device demonstrates a key contribution in the field of portable electronics for defense safety and environmental monitoring applications.


  • Fluorescence Resonance Energy Transfer-Based Wash-Free Bacterial Imaging and Antibacterial Application Using a Cationic Conjugated Polyelectrolyte

    by Nehal Zehra, Deepanjalee Dutta, Akhtar Hussain Malik, Siddhartha Sankar Ghosh, Parameswar Krishnan Iyer

    The increase in bacterial infection and antibiotic resistance has posed a severe threat to the human health. This threat has warranted an imperative demand for the development of new and effective bactericidal material to eradicate the antibiotic-resistant pathogenic bacteria. In this work, we report the wash free imaging of Staphylococcus aureus (Gram-positive) and Escherichia coli (Gram-negative) bacteria using cationic conjugated polyelectrolyte[9,9-bis(6′-methylimidazoliumbromide)hexyl)-fluorene-co-4,7-(2,1,3 benzothiadiazole)] (PFBT-MI) based on aggregation-induced fluorescence resonance energy transfer (FRET). Cationic imidazolium group strapped on the polymer side chain not only increases its solubility in water but also helps in binding with the negatively charged bacterial membrane via electrostatic interactions to turn on its bright yellow emission. The change in the fluorescence color of conjugated polyelectrolyte in presence of bacteria could be visualized very easily via naked eyes under a UV lamp (365 nm). Furthermore, the antibacterial activity of PFBT-MI against both Staphylococcus aureus as well as Escherichia coli was observed because of the amphiphilic nature of the conjugated polyelectrolyte which in turn is due to the presence of ionic functionality and conjugated polymer backbone that can intercalate very proficiently into the bacterial membrane, which disrupts the membrane integrity and thus results in toxicity. Morphologically, the membrane damage was perceived via FESEM images, which clearly indicated the disruption of cell membrane upon exposure to PFBT-MI. The PFBT-MI acts as an effective antibacterial agent, with an MIC and MBC value of (30 µM or 23.7 µg/mL) and (60 µM or 47.7 µg/mL) for Staphylococcus aureus and for E. coli (60 µM or 47.7 µg/mL) and (100 µM or 79 µg/mL), respectively. Moreover, PFBT-MI shows less cytotoxicity against mammalian cells at concentration greater than MIC.