Zhongbin Lv
Zhongbin Lv has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liu
Transmission & Transformation Engineering Department, China Electric Power Research Institute, Beijing 100055, China
1 shared publication - Bo Yan
College of Aerospace Engineering, Chongqing University, Chongqing, China
1 shared publication - Chuan Wu
State Grid Henan Electric Power Research Institute, Zhengzhou 450052, China
1 shared publication - Guizao Huang
Southwest Jiaotong University
1 shared publication - Jiaqiong Liu
Chongqing University, 47913 Chongqing China
1 shared publication Kunpeng Ji
China Electric Power Research Institute beijing, 100055, China
1 shared publication
Latest Publications
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1423-1431
Experimental Study on Torsional Behavior of Twin Bundle Conductor Lines
The torsional behavior of twin bundle conductor lines is investigated by means of experiments. Based on similarity principle, the reduced-scale modelling method for simulating the torsional behavior of bundle conductor lines is presented and validated by the test results of full-scale transmission lines. Parameter study on torsional behavior of twin bundle conductor lines under different parameters, including loading and unloading rates of applying torque, initial tension in sub-conductors, layout of sub-conductors, number of spacers, clamps between spacers and sub-conductors and arrangement of spacers, is carried out by means of reduced-scale modelling tests. The effects of these parameters on the torsional stiffness, collapse moment, collapse angle, self-restoring moment of twin bundle conductor lines are obtained. It is observed that a collapsed bundle conductor line may not be able to return to its initial position after releasing load, which reflects the phenomenon observed in real transmission lines, and optimal arrangement of spacers in a bundle conductor line may exist to prevent or mitigate the torsional instability in the case without considering other factors such as sub-span oscillation. The presented reduced-scale modelling method and test results provide a foundation for further understanding of torsional instability and control of bundle conductors rolling.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (3) , 1423-1431
Experimental Study on Torsional Behavior of Twin Bundle Conductor Lines
The torsional behavior of twin bundle conductor lines is investigated by means of experiments. Based on similarity principle, the reduced-scale modelling method for simulating the torsional behavior of bundle conductor lines is presented and validated by the test results of full-scale transmission lines. Parameter study on torsional behavior of twin bundle conductor lines under different parameters, including loading and unloading rates of applying torque, initial tension in sub-conductors, layout of sub-conductors, number of spacers, clamps between spacers and sub-conductors and arrangement of spacers, is carried out by means of reduced-scale modelling tests. The effects of these parameters on the torsional stiffness, collapse moment, collapse angle, self-restoring moment of twin bundle conductor lines are obtained. It is observed that a collapsed bundle conductor line may not be able to return to its initial position after releasing load, which reflects the phenomenon observed in real transmission lines, and optimal arrangement of spacers in a bundle conductor line may exist to prevent or mitigate the torsional instability in the case without considering other factors such as sub-span oscillation. The presented reduced-scale modelling method and test results provide a foundation for further understanding of torsional instability and control of bundle conductors rolling.
- Open Access
- 23 March 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 128 (1) , 012123
Research on the Test of Transmission Line Galloping
The load of iced transmission line and the load generated by galloping after the conductor are covered by ice all may cause severe circuit faults, such as tripping, conductor breaking, armor clamp damage and even tower collapse, thus severely threatening running safety of power system. The generation and development processes of galloping of power transmission line is very complicated, and numerous factors may influence the galloping excitation, such as environmental factors, terrain factors and structural parameters of power transmission line; in which, the ice covering of conductor is one of necessary factors causing galloping. Therefore, researches on ice covering increasing test of different types of conductors under different meteorological conditions have been conducted in large-sized multi-functional phytotron, thus obtaining the relation curve of ice covering increasing of conductor along with time under different conditions, and analyzing factors influencing increasing of ice covering. The research result shows that under the same ice covering conditions, the increasing of ice covering of conductor with small diameter is relatively rapid; both environmental temperature and wind speed have obvious influence on increasing of ice covering of conductor, and the environmental temperature will decide the type of ice covering of conductor surface. Meanwhile, after wind tunnel tests targeting conductors with different ice covering shapes, pneumatic stability loss characteristics of conductors with different ice shapes have been obtained. Research results have important scientific reference value for revealing the mechanism of galloping of iced power transmission line, and have relatively high engineering practicability value for promoting realization of early warning system for galloping of iced power transmission line.
- 23 March 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 128 (1) , 012123
Open AccessResearch on the Test of Transmission Line Galloping
The load of iced transmission line and the load generated by galloping after the conductor are covered by ice all may cause severe circuit faults, such as tripping, conductor breaking, armor clamp damage and even tower collapse, thus severely threatening running safety of power system. The generation and development processes of galloping of power transmission line is very complicated, and numerous factors may influence the galloping excitation, such as environmental factors, terrain factors and structural parameters of power transmission line; in which, the ice covering of conductor is one of necessary factors causing galloping. Therefore, researches on ice covering increasing test of different types of conductors under different meteorological conditions have been conducted in large-sized multi-functional phytotron, thus obtaining the relation curve of ice covering increasing of conductor along with time under different conditions, and analyzing factors influencing increasing of ice covering. The research result shows that under the same ice covering conditions, the increasing of ice covering of conductor with small diameter is relatively rapid; both environmental temperature and wind speed have obvious influence on increasing of ice covering of conductor, and the environmental temperature will decide the type of ice covering of conductor surface. Meanwhile, after wind tunnel tests targeting conductors with different ice covering shapes, pneumatic stability loss characteristics of conductors with different ice shapes have been obtained. Research results have important scientific reference value for revealing the mechanism of galloping of iced power transmission line, and have relatively high engineering practicability value for promoting realization of early warning system for galloping of iced power transmission line.