RERebeca Echeverria‐Chasco

Rebeca Echeverria‐Chasco

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rebeca Echeverria‐Chasco has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of pseudo‐continuous arterial spin labeling for brain perfusion imaging in the intraoperative setting

    by Carmen Sánchez‐Albardíaz, Marta Calvo‐Imirizaldu, Verónica Aramendía‐Vidaurreta, Rebeca Echeverria‐Chasco, Marta Vidorreta, Bartolomé Bejarano, Lain H. Gonzalez‐Quarante, Ana Aransay García, Cristina Honorato, Elena Cacho‐Asenjo, et al.

    Purpose: Pseudo‐continuous arterial spin labeling (PCASL) efficiency during intraoperative MRI is degraded due to large field inhomogeneities observed in some patients and lower arterial blood velocities induced by anesthesia. The purpose of this work was to maximize labeling efficiency during intraoperative MRI by optimizing PCASL parameters at 3 T. Methods: Effects of PCASL labeling pulse interval and gradient parameters on labeling efficiency were first investigated by numerical simulations based on Bloch equations. PCASL parameters were modified accordingly, considering hardware constraints, and evaluated experimentally. An experiment in healthy volunteers compared three labeling pulse intervals. In intraoperative brain tumor patients, different configurations were tested in two experiments: different labeling pulse intervals in patient experiment 1, and different labeling pulse interval and gradient average () in experiment 2. Results: Numerical simulations showed that shortening the labeling pulse interval improved robustness of PCASL to off‐resonance effects and that raising the increased labeling efficiency for lower blood velocity profiles. In healthy volunteers for large off‐resonance, perfusion signal obtained with the labeling pulse interval of 600 μs was significantly higher than the one obtained with 1000 μs and 1400 μs ( p‐value < 0.001). In patients, a short labeling pulse interval of 600 μs and of 0.9 mT/m improved the quality of perfusion maps and significantly increased quantified cerebral blood flow values ( p‐value = 0.0078). Conclusion: Shortening the labeling pulse interval and increasing the gradient average improves PCASL efficiency in the intraoperative setting.


  • Open Access

    Influence of Field Strength, Sex, and Age on Pseudo‐Continuous Arterial Spin Labeling and T1 Mapping in the Kidney

    by Leyre Garcia‐Ruiz, Rebeca Echeverria‐Chasco, Verónica Aramendía‐Vidaurreta, Sergio M. Solis‐Barquero, Nuria Garcia‐Fernandez, José María Mora‐Gutiérrez, Marta Vidorreta, Gorka Bastarrika, Maria A. Fernández‐Seara

    Background: Pseudo‐continuous arterial spin labeling (PCASL) and T1 mapping have been used for renal imaging at 1.5 T and 3 T. However, direct comparisons between field strengths, age, and sex are lacking.Purpose: To assess the effects of field strength, age, and sex on renal perfusion and T1 values and measure reproducibility.Study Type: Prospective.Population: Sixteen healthy volunteers (eight females, age 41.8 ± 13.3 years) underwent same‐day scans at 1.5 T and 3 T, repeated 1 week later.Field Strength/Sequence: 1.5 T/3 T multi‐delay PCASL with spin‐echo EPI readout, inversion‐recovery T1 mapping, B0 and B1 mapping.Assessment: Multi‐delay PCASL was employed to calculate renal blood flow (RBF) and arterial transit time (ATT) maps; single‐delay PCASL (PLD = 1.3 s) assessed RBF and technical parameters. Cortical and medullary RBF, ATT, and T1 were compared between field strengths, age, and sex groups. Reproducibility and inter‐observer agreement were evaluated.Statistical Tests: Shapiro–Wilk test, analysis of variance, Levene test, Box M‐test, Pearson's correlation, within‐subject coefficient of variation (wsCV), and intraclass correlation coefficient (ICC). P‐value < 0.05 was significant.Results: 3 T yielded significantly higher cortical T1 (1356.02 ± 3.72 vs. 1023.29 ± 39.30 ms), and lower RBF (310.63 ± 52.72 vs. 347.65 ± 54.08 [mL/min/100 g]) than 1.5 T. Eight older (≥ 40 years) participants had significantly lower cortical RBF (1.5 T: 312.23 ± 37.59 vs. 383.06 ± 43.91 [mL/min/100 g]). Females showed significantly shorter ATT (1.5 T: 0.75 ± 0.11 s vs. 0.96 ± 0.22 s) and longer medullary T1 (1.5 T: 1388.12 ± 33.68 ms vs. 1308.97 ± 28.52 ms). T1 showed excellent reproducibility and inter‐observer agreement (wsCV: < 2%, ICC: > 0.8). Cortical RBF was reproducible (wsCV: ~10%, ICC: > 0.7) with strong inter‐observer agreement (wsCV: < 2.5%, ICC > 0.95). Medullary RBF had good inter‐observer agreement (wsCV: < 4.7%, ICC: > 0.75) but poor reproducibility (wsCV: 15.78%–19.38%).Data Conclusion: Cortical perfusion parameters and T1 were reproducible. However, age, sex, and field strength affect the values, requiring consideration in renal imaging.Evidence Level: Level 2.Technical Efficacy: Stage 1.


  • Open Access

    Advancing ASL kidney image registration: a tailored pipeline with VoxelMorph

    by Anne Oyarzun-Domeño, Izaskun Cia, Rebeca Echeverria-Chasco, María A. Fernández-Seara, Paloma L. Martin-Moreno, Nuria Garcia-Fernandez, Gorka Bastarrika, Javier Navallas, Arantxa Villanueva

    In clinical renal assessment, image registration plays a pivotal role, as patient movement during data acquisition can significantly impede image post-processing and the accurate estimation of hemodynamic parameters. This study introduces a deep learning-based image registration framework specifically for arterial spin labeling (ASL) imaging. ASL is a magnetic resonance imaging technique that modifies the longitudinal magnetization of blood perfusing the kidney using a series of radiofrequency pulses combined with slice-selective gradients. After tagging the arterial blood, label images are captured following a delay, allowing the tagged blood bolus to enter the renal tissue, while control images are acquired without tagging the arterial spins. Given that perfusion maps are generated at the pixel level by subtracting control images from label images and considering the relatively small signal intensity difference, precise alignment of these images is crucial to minimize motion artefacts and prevent significant errors in perfusion calculations. Moreover, due to the extended ASL acquisition times and the anatomical location of the kidneys, renal images are often susceptible to pulsation, peristalsis, and breathing motion. These motion-induced noises and other instabilities can adversely affect ASL imaging outcomes, making image registration essential. However, research on renal MRI registration, particularly with respect to learning-based techniques, remains limited, with even less focus on renal ASL. Our study proposes a learning-based image registration approach that builds upon VoxelMorph and introduces groupwise inference as a key enhancement. The dataset includes 2448 images of transplanted kidneys (TK) and 2456 images of healthy kidneys (HK). We compared the automatic image registration results with the widely recognized optimization method Elastix. The model’s performance was evaluated using the mean structural similarity index (MSSIM), normalized correlation coefficient (NCC), temporal signal-to-noise ratio (TSNR) of the samples, and the mean cortical signal (CSIM) in perfusion-weighted images, thereby extending the evaluation beyond traditional similarity-based metrics. Our method achieved superior image registration performance, with peak NCC (0.987 ± 0.006) and MSSIM (0.869 ± 0.048) values in the kidney region, significantly surpassing Elastix and the unregistered series (p < 0.05) on TK and HK datasets. Regularization analysis showed that higher λ values (1, 2) produced smoother deformation fields, while moderate λ values (0.5, 0.9) balanced smoothness and detail, maintaining low non-positive Jacobian percentages (<1%) comparable to Elastix. Additionally, our method improved CSIM by 14.3% (2.304 ± 1.167) and TSNR by 13.1% (3.888 ± 2.170) in TK, and achieved up to 13.2% (CSIM) and 29.8% (TSNR) enhancements in HK, demonstrating robustness and improved signal quality across datasets and acquisition techniques.


  • Open Access

    Diagnostic and Prognostic Potential of Multiparametric Renal MRI in Kidney Transplant Patients

    by Rebeca Echeverria‐Chasco, Paloma L. Martin‐Moreno, Veronica Aramendía‐Vidaurreta, Leyre Garcia‐Ruiz, José María Mora‐Gutiérrez, Marta Vidorreta, Arantxa Villanueva, David Cano, Gorka Bastarrika, Nuria Garcia‐Fernandez, et al.

    Background: Multiparametric MRI provides assessment of functional and structural parameters in kidney allografts. It offers a non‐invasive alternative to the current reference standard of kidney biopsy.Purpose: To evaluate the diagnostic and prognostic utility of MRI parameters in the assessment of allograft function in the first 3‐months post‐transplantation.Study Type: Prospective.Subjects: 32 transplant recipients (54 ± 17 years, 20 females), divided into two groups according to estimated glomerular filtration rate (eGFR) at 3‐months post‐transplantation: inferior graft function (IGF; eGFR2, n = 10) and superior graft function (SGF; eGFR ≥ 45 mL/min/1.73 m2, n = 22). Further categorization was based on the need for hemodialysis (C1) and decrease in s‐creatinine (C2) at 1‐week post‐transplantation: delayed‐graft‐function (DGF: n = 4 C1, n = 10 C2) and early graft‐function (EGF: n = 28 C1, n = 22 C2).Field Strength/Sequence: 3‐T, pseudo‐continuous arterial spin labeling, T1‐mapping, and diffusion‐weighted imaging.Assessment: Multiparametric MRI was evaluated at 1‐week in all patients and 3‐months after transplantation in 28 patients. Renal blood flow (RBF), diffusion coefficients (ADC, ΔADC, D, D, D*, flowing fraction f), T1 and T1 were calculated in cortex and medulla. The diagnostic and prognostic value of these parameters, obtained at 3‐months and 1‐week post‐transplantation, respectively, was evaluated in the cortex to discriminate between DGF and EGF, and between SGF and IGF.Statistical Tests: Logistic regression, receiver‐operating‐characteristics, area‐under‐the‐curve (AUC), confidence intervals (CIs), analysis‐of‐variance, t‐test, Wilcoxon‐Mann–Whitney test, Fisher's exact test, Pearson's correlation. P‐valueD*. The diagnostic value of MRI for detecting DGF was excellent (AUC = 100%). Significant differences between patients with IGF and SGF were found in RBF, ∆T1, and ∆D. Multiparametric MRI showed higher diagnostic (AUC = 95.32%; CI: 88%–100%) and prognostic (AUC = 97.47%, CI: 92%–100%) values for detecting IGF than eGFR (AUC = 89.50%, CI: 79%–100%).Data Conclusion: Multiparametric MRI may show high diagnostic and prognostic value in transplanted patients, yielding better results compared to eGFR measurements.Level of Evidence: 2Technical Efficacy: Stage 1


  • Open Access

    Comparison of Myocardial Blood Flow Quantification Models for Double ECG Gating Arterial Spin Labeling MRI: Reproducibility Assessment

    by Verónica Aramendía‐Vidaurreta, Sergio M. Solís‐Barquero, Marta Vidorreta, Ana Ezponda, Rebeca Echeverria‐Chasco, Gorka Bastarrika, María A. Fernández‐Seara

    Background: Arterial spin labeling (ASL) allows non‐invasive quantification of myocardial blood flow (MBF). Double‐ECG gating (DG) ASL is more robust to heart rate variability than single‐ECG gating (SG), but its reproducibility requires further investigation. Moreover, the existence of multiple quantification models hinders its application. Frequency‐offset‐corrected‐inversion (FOCI) pulses provide sharper edge profiles than hyperbolic‐secant (HS), which could benefit myocardial ASL.Purpose: To assess the performance of MBF quantification models for DG compared to SG ASL, to evaluate their reproducibility and to compare the effects of HS and FOCI pulses.Study Type: Prospective.Subjects: Sixteen subjects (27 ± 8 years).Field Strength/Sequence: 1.5 T/DG and SG flow‐sensitive alternating inversion recovery ASL.Assessment: Three models for DG MBF quantification were compared using Monte Carlo simulations and in vivo experiments. Two models used a fitting approach (one using only a single label and control image pair per fit, the other using all available image pairs), while the third model used a T1 correction approach. Slice profile simulations were conducted for HS and FOCI pulses with varying B0 and B1. Temporal signal‐to‐noise ratio (tSNR) was computed for different acquisition/quantification strategies and inversion pulses. The number of images that minimized MBF error was investigated in the model with highest tSNR. Intra and intersession reproducibility were assessed in 10 subjects.Statistical Tests: Within‐subject coefficient of variation, analysis of variance. P‐value P = 0.27) nor pulses (P = 0.9). DG MBF quantification models exhibited significantly higher tSNR and superior reproducibility, particularly for the fitting model using multiple images (tSNR was 3.46 ± 2.18 in vivo and 3.32 ± 1.16 in simulations, respectively; wsCV = 16%). Reducing the number of ASL pairs to 13/15 did not increase MBF error (minimum = 0.22 mL/g/min).Data Conclusion: Reproducibility of MBF was better for DG than SG acquisitions, especially when employing a fitting model.Level of Evidence: 2Technical Efficacy: Stage 1


  • Open Access

    A deep learning image analysis method for renal perfusion estimation in pseudo-continuous arterial spin labelling MRI

    by Anne Oyarzun-Domeño, Izaskun Cia, Rebeca Echeverria-Chasco, María A. Fernández-Seara, Paloma L. Martin-Moreno, Nuria Garcia-Fernandez, Gorka Bastarrika, Javier Navallas, Arantxa Villanueva


  • Open Access

    Assessment of Splenic Switch‐Off With Arterial Spin Labeling in Adenosine Perfusion Cardiac MRI

    by Verónica Aramendía‐Vidaurreta, Sergio M. Solis‐Barquero, Ana Ezponda, Marta Vidorreta, Rebeca Echeverria‐Chasco, Marina Pascual, Gorka Bastarrika, María A. Fernández‐Seara

    Background: In patients with suspected coronary artery disease (CAD), myocardial perfusion is assessed under rest and pharmacological stress to identify ischemia. Splenic switch‐off, defined as the stress to rest splenic perfusion attenuation in response to adenosine, has been proposed as an indicator of stress adequacy. Its occurrence has been previously assessed in first‐pass perfusion images, but the use of noncontrast techniques would be highly beneficial.Purpose: To explore the ability of pseudo‐continuous arterial spin labeling (PCASL) to identify splenic switch‐off in patients with suspected CAD.Study Type: Prospective.Population: Five healthy volunteers (age 24.8 ± 3.8 years) and 32 patients (age 66.4 ± 8.2 years) with suspected CAD.Field strength/Sequence: A 1.5‐T/PCASL (spin‐echo) and first‐pass imaging (gradient‐echo).Assessment: In healthy subjects, multi‐delay PCASL data (500–2000 msec) were acquired to quantify splenic blood flow (SBF) and determine the adequate postlabeling delay (PLD) for single‐delay acquisitions (PLD > arterial transit time). In patients, single‐delay PCASL (1200 msec) and first‐pass perfusion images were acquired under rest and adenosine conditions. PCASL data were used to compute SBF maps and SBF stress‐to‐rest ratios. Three observers classified patients into “switch‐off” and “failed switch‐off” groups by visually comparing rest‐stress perfusion data acquired with PCASL and first‐pass, independently. First‐pass categories were used as reference to evaluate the accuracy of quantitative classification.Statistical Tests: Wilcoxon signed‐rank, Pearson correlation, kappa, percentage agreement, Generalized Linear Mixed Model, Mann–Whitney, Pearson Chi‐squared, receiver operating characteristic, area‐under‐the‐curve (AUC) and confusion matrix. Significance: P value < 0.05.Results: A total of 27 patients (84.4%) experienced splenic switch‐off according to first‐pass categories. Comparison of PCASL‐derived SBF maps during stress and rest allowed assessment of splenic switch‐off, reflected in a reduction of SBF values during stress. SBF stress‐to‐rest ratios showed a 97% accuracy (sensitivity = 80%, specificity = 100%, AUC = 85.2%).Data Conclusion: This study could demonstrate the feasibility of PCASL to identify splenic switch‐off during adenosine perfusion MRI, both by qualitative and quantitative assessments.Evidence Level: 2Technical Efficacy: 2


  • Open Access

    Multiparametric renal magnetic resonance imaging: A reproducibility study in renal allografts with stable function

    by Rebeca Echeverria‐Chasco, Paloma L. Martin‐Moreno, Nuria Garcia‐Fernandez, Marta Vidorreta, Verónica Aramendia‐Vidaurreta, David Cano, Arantxa Villanueva, Gorka Bastarrika, Maria A. Fernández‐Seara

    Monitoring renal allograft function after transplantation is key for the early detection of allograft impairment, which in turn can contribute to preventing the loss of the allograft. Multiparametric renal MRI (mpMRI) is a promising noninvasive technique to assess and characterize renal physiopathology; however, few studies have employed mpMRI in renal allografts with stable function (maintained function over a long time period). The purposes of the current study were to evaluate the reproducibility of mpMRI in transplant patients and to characterize normal values of the measured parameters, and to estimate the labeling efficiency of Pseudo‐Continuous Arterial Spin Labeling (PCASL) in the infrarenal aorta using numerical simulations considering experimental measurements of aortic blood flow profiles. The subjects were 20 transplant patients with stable kidney function, maintained over 1 year. The MRI protocol consisted of PCASL, intravoxel incoherent motion, and T1 inversion recovery. Phase contrast was used to measure aortic blood flow. Renal blood flow (RBF), diffusion coefficient (D), pseudo‐diffusion coefficient (D*), flowing fraction ( ), and T1 maps were calculated and mean values were measured in the cortex and medulla. The labeling efficiency of PCASL was estimated from simulation of Bloch equations. Reproducibility was assessed with the within‐subject coefficient of variation, intraclass correlation coefficient, and Bland‐Altman analysis. Correlations were evaluated using the Pearson correlation coefficient. The significance level was p less than 0.05. Cortical reproducibility was very good for T1, D, and RBF, moderate for , and low for D*, while medullary reproducibility was good for T1 and D. Significant correlations in the cortex between RBF and (r = 0.66), RBF and eGFR (r = 0.64), and D* and eGFR (r = −0.57) were found. Normal values of the measured parameters employing the mpMRI protocol in kidney transplant patients with stable function were characterized and the results showed good reproducibility of the techniques.


  • Open Access

    Reduction of motion effects in myocardial arterial spin labeling

    by Verónica Aramendía‐Vidaurreta, Pedro M. Gordaliza, Marta Vidorreta, Rebeca Echeverría‐Chasco, Gorka Bastarrika, Arrate Muñoz‐Barrutia, María A. Fernández‐Seara

    Purpose: To evaluate the accuracy and reproducibility of myocardial blood flow measurements obtained under different breathing strategies and motion correction techniques with arterial spin labeling.Methods: A prospective cardiac arterial spin labeling study was performed in 12 volunteers at 3 Tesla. Perfusion images were acquired twice under breath‐hold, synchronized‐breathing, and free‐breathing. Motion detection based on the temporal intensity variation of a myocardial voxel, as well as image registration based on pairwise and groupwise approaches, were applied and evaluated in synthetic and in vivo data. A region of interest was drawn over the mean perfusion‐weighted image for quantification. Original breath‐hold datasets, analyzed with individual regions of interest for each perfusion‐weighted image, were considered as reference values.Results: Perfusion measurements in the reference breath‐hold datasets were in line with those reported in literature. In original datasets, prior to motion correction, myocardial blood flow quantification was significantly overestimated due to contamination of the myocardial perfusion with the high intensity signal of blood pool. These effects were minimized with motion detection or registration. Synthetic data showed that accuracy of the perfusion measurements was higher with the use of registration, in particular after the pairwise approach, which probed to be more robust to motion.Conclusion: Satisfactory results were obtained for the free‐breathing strategy after pairwise registration, with higher accuracy and robustness (in synthetic datasets) and higher intrasession reproducibility together with lower myocardial blood flow variability across subjects (in in vivo datasets). Breath‐hold and synchronized‐breathing after motion correction provided similar results, but these breathing strategies can be difficult to perform by patients.


  • Open Access

    Perspectives on the Role of Magnetic Resonance Imaging (MRI) for Noninvasive Evaluation of Diabetic Kidney Disease

    by José María Mora-Gutiérrez, María A. Fernández-Seara, Rebeca Echeverria-Chasco, Nuria Garcia-Fernandez

    Renal magnetic resonance imaging (MRI) techniques are currently in vogue, as they provide in vivo information on renal volume, function, metabolism, perfusion, oxygenation, and microstructural alterations, without the need for exogenous contrast media. New imaging biomarkers can be identified using these tools, which represent a major advance in the understanding and study of the different pathologies affecting the kidney. Diabetic kidney disease (DKD) is one of the most important diseases worldwide due to its high prevalence and impact on public health. However, its multifactorial etiology poses a challenge for both basic and clinical research. Therefore, the use of novel renal MRI techniques is an attractive step forward in the comprehension of DKD, both in its pathogenesis and in its detection and surveillance in the clinical practice. This review article outlines the most promising MRI techniques in the study of DKD, with the purpose of stimulating their clinical translation as possible tools for the diagnosis, follow-up, and monitoring of the clinical impacts of new DKD treatments.