Santanu Prasad Datta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Santanu Prasad Datta has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Chanchal Chakraborty
4 shared publications- Ronanki Suresh
Department of Mechanical Engineering, BITS Pilani, Hyderabad-500078, India
4 shared publications - Satyapaul A. Singh
Department of Chemical Engineering, BITS-Pilani, Hyderabad Campus, Jawahar Nagar, Kapra Mandal, Hyderabad 500078, India
4 shared publications Sounak Roy
4 shared publicationsKokkula Monika
Department of Mechanical Engineering, BITS Pilani, Hyderabad Campus, 500078, India
3 shared publications- Srikanta Dinda
Department of Chemical Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad 500078, India
3 shared publications
Latest Publications
- 1 January 2022
- Published by Begell House Inc. Publishers
- p. 251-256
Numerical analysis of spiral channelled cooling plates for thermal management of pouch battery module
Temporal variations can significantly impact li-ion batteries working and cycle life expectancy under severe operating and climatic conditions. Concerning this, indirect liquid cooling is known to be the most commonly used technique. However, a need for heat transfer augmentation still exists to minimize the module's crowning temperature and temperature gradient. Hence, the current study suggests and designs a novel liquid cooling plate comprising a spiral channel configuration to reduce the thermal non-linearity across the battery module. For this COMSOL Multiphysics software is utilised where an electrothermal model is combined with the conjugate heat transfer model. The thermal variations of pouch battery module in conjunction with the suggested cold plate design are assessed for a varying mass flow rate and a discharge rate fixed at 3C. Outcomes of the present analysis indicate that altering the mass flow rate in a range of 0.001 to 0.005 kg s-1 reduces the average temperature by 3.81 °C. Alongside, the heat transfer coefficient is enhanced by 1.56%.
- 1 January 2022
- Published by Begell House Inc. Publishers
- p. 251-256
Numerical analysis of spiral channelled cooling plates for thermal management of pouch battery module
Temporal variations can significantly impact li-ion batteries working and cycle life expectancy under severe operating and climatic conditions. Concerning this, indirect liquid cooling is known to be the most commonly used technique. However, a need for heat transfer augmentation still exists to minimize the module's crowning temperature and temperature gradient. Hence, the current study suggests and designs a novel liquid cooling plate comprising a spiral channel configuration to reduce the thermal non-linearity across the battery module. For this COMSOL Multiphysics software is utilised where an electrothermal model is combined with the conjugate heat transfer model. The thermal variations of pouch battery module in conjunction with the suggested cold plate design are assessed for a varying mass flow rate and a discharge rate fixed at 3C. Outcomes of the present analysis indicate that altering the mass flow rate in a range of 0.001 to 0.005 kg s-1 reduces the average temperature by 3.81 °C. Alongside, the heat transfer coefficient is enhanced by 1.56%.
- 1 January 2022
- Published by Begell House Inc. Publishers
- p. 265-270
A Real Gas Property-Based Thermodynamic Investigation of Ejector Based Refrigeration System for Automotive Applications
Ejector refrigeration system (ERS) is a favourable technology to recover the available exhaust heat of automobiles for cooling purposes due to its uncomplicated structure, low cost and easy maintenance compared to the other systems. Despite these advantages, it suffers from poor performance because of the irreversible fluid flow structures inside the ejector. The refrigerant variant used, operating parameters and design specifications influencing the ejector flow can affect the ERS performance significantly. As per the European Parliament Directive 517/2014, the restrictions towards the usage of high global warming potential (GWP) refrigerant R134a reveals the necessity to find low-GWP alternates. Accordingly, in the present study, a real gas property-based theoretical model is developed to estimate the ERS behaviour with six low-GWP substitutes for R134a: R1234yf, R1243zf R1234ze(E), R152a, R513a and R440a. Within a wide variety of evaporator and generator temperatures, the performance of the proposed model is analyzed under the critical mode of operation. Results indicate that for R1243zf and R1234yf ejector cycles, the entrainment ratio is maximum and almost equal. The coefficient of performance is observed as maximum and nearly equal with R152a and R440a. Though the COP values are higher for the refrigerants R152a and R440a because of their higher GWP, it is suggested to use the next higher COP refrigerants R1234yf and R1243zf in the ERS integrated with automotive applications.
- 1 January 2022
- Published by Begell House Inc. Publishers
- p. 265-270
A Real Gas Property-Based Thermodynamic Investigation of Ejector Based Refrigeration System for Automotive Applications
Ejector refrigeration system (ERS) is a favourable technology to recover the available exhaust heat of automobiles for cooling purposes due to its uncomplicated structure, low cost and easy maintenance compared to the other systems. Despite these advantages, it suffers from poor performance because of the irreversible fluid flow structures inside the ejector. The refrigerant variant used, operating parameters and design specifications influencing the ejector flow can affect the ERS performance significantly. As per the European Parliament Directive 517/2014, the restrictions towards the usage of high global warming potential (GWP) refrigerant R134a reveals the necessity to find low-GWP alternates. Accordingly, in the present study, a real gas property-based theoretical model is developed to estimate the ERS behaviour with six low-GWP substitutes for R134a: R1234yf, R1243zf R1234ze(E), R152a, R513a and R440a. Within a wide variety of evaporator and generator temperatures, the performance of the proposed model is analyzed under the critical mode of operation. Results indicate that for R1243zf and R1234yf ejector cycles, the entrainment ratio is maximum and almost equal. The coefficient of performance is observed as maximum and nearly equal with R152a and R440a. Though the COP values are higher for the refrigerants R152a and R440a because of their higher GWP, it is suggested to use the next higher COP refrigerants R1234yf and R1243zf in the ERS integrated with automotive applications.
- 14 December 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (5) , 5503-5522
An insight of CO 2 hydrogenation to methanol synthesis: Thermodynamics, catalysts, operating parameters, and reaction mechanism
- 14 December 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (5) , 5503-5522
An insight of CO 2 hydrogenation to methanol synthesis: Thermodynamics, catalysts, operating parameters, and reaction mechanism