Sandor Szatmari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sandor Szatmari has a total of 220 co-authors. Here are the top co-authors by number of shared publications:
F. P. Schäfer
Abteilung Laserphysik, Max-Planck-Institut für biophysikalische Chemie, Göttingen, Germany
14 shared publicationsP. Simon
14 shared publicationsJ. Bohus
6 shared publicationsG. Kühnle
Max-Planck-Institut für biophysikalische Chemie
5 shared publicationsG. Marowsky
Laser Laboratorium Göttingen e.V., Hans-Adolf-Krebs Weg 1, 37077 Göttingen, Germany DE
5 shared publicationsF.P. Schäfer
4 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Spatially controlled x-ray field generation by a twin cylindrical x-ray gun
Homogeneous excitation of large-aperture excimer gain modules by discharge pumping involves a critical interplay between the temporal and spatial properties of both pumping and preionization. Previously, a promising x-ray preionization scheme based on the use of two cylindrical x-ray guns was introduced, where the spatial distribution of the generated x-ray field could be effectively controlled by their positions. It has not been exploited yet that the rotation of the guns offers one more free parameter to fine-tune the spatial properties of the x-ray field due to the angular dependence of their emission. In this paper, we demonstrate both numerically and experimentally that by utilizing the specific angular dependence of the emission from cylindrical, cold-cathode x-ray guns, an improved spatial homogeneity of the generated x-ray field can be achieved. Through a proper choice of gun positions and cathode orientation, the spatial boundaries of the generated x-ray field for a given homogeneity can be significantly extended. This allows for a decreased distance between the x-ray guns and the volume to be homogeneously irradiated, where the minimum useable distance is no longer limited by the increased inhomogeneity of the field but only by practical geometrical limitations. Based on the r−1 spatial dependence of the radiation, this configuration offers a more than twofold increase in the intensity of the x-ray field, alongside improved spatial homogeneity, while maintaining the previously reported spatial tunability of the preionization. These optimized arrangements can be deployed in closer proximity to—or even inside—the discharge chamber.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessSpatially controlled x-ray field generation by a twin cylindrical x-ray gun
Homogeneous excitation of large-aperture excimer gain modules by discharge pumping involves a critical interplay between the temporal and spatial properties of both pumping and preionization. Previously, a promising x-ray preionization scheme based on the use of two cylindrical x-ray guns was introduced, where the spatial distribution of the generated x-ray field could be effectively controlled by their positions. It has not been exploited yet that the rotation of the guns offers one more free parameter to fine-tune the spatial properties of the x-ray field due to the angular dependence of their emission. In this paper, we demonstrate both numerically and experimentally that by utilizing the specific angular dependence of the emission from cylindrical, cold-cathode x-ray guns, an improved spatial homogeneity of the generated x-ray field can be achieved. Through a proper choice of gun positions and cathode orientation, the spatial boundaries of the generated x-ray field for a given homogeneity can be significantly extended. This allows for a decreased distance between the x-ray guns and the volume to be homogeneously irradiated, where the minimum useable distance is no longer limited by the increased inhomogeneity of the field but only by practical geometrical limitations. Based on the r−1 spatial dependence of the radiation, this configuration offers a more than twofold increase in the intensity of the x-ray field, alongside improved spatial homogeneity, while maintaining the previously reported spatial tunability of the preionization. These optimized arrangements can be deployed in closer proximity to—or even inside—the discharge chamber.
- Open Access
- 1 February 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (2)
Short rise- and decay-time Z-pinch currents for soft x-ray laser excitation
The article addresses how to create inductance-free plasma and use it to excite soft x-ray lasers. The method employs a bifilar phenomenon in which one part of the pulsed current flows via the plasma column while the other part runs in the opposite direction via the closely placed external conductor. The electromagnetic fields formed by the plasma and return conductor are adjusted by lowering the distance between them to neutralize the magnetic field of the bifilar. Because the net transient magnetic field is drastically reduced, the plasma-conductor mutual inductance is near zero during current rise and decay. The inductance-free (L ∼ 2 nH) 35 cm-long Z pinches in a 3.1 mm-diameter argon-filled alumina capillary with current rise and decay times of 15 ns, dI/dt > 1012 A/s, and amplitudes up to 17 kA were predicted, realized, and verified to be suitable for pumping soft x-ray Ar+8 lasers. Without the bifilar phenomenon, the 35 cm Z pinches obey a 200 nH inductance that restricts the rise and decay durations of currents to 150 ns. The 35 cm Z pinches with 2 nH inductance generated 46.9 nm laser pulses with up to 4 μJ of energy and a beam divergence of 2 mrad at a low operating voltage of 35–45 kV, compared to 0.1–0.8 MV for similar lasers. The bifilar method could find applications in many research and technological fields, where the rise and decay times of discharge currents play a key role.
- 1 February 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (2)
Open AccessShort rise- and decay-time Z-pinch currents for soft x-ray laser excitation
The article addresses how to create inductance-free plasma and use it to excite soft x-ray lasers. The method employs a bifilar phenomenon in which one part of the pulsed current flows via the plasma column while the other part runs in the opposite direction via the closely placed external conductor. The electromagnetic fields formed by the plasma and return conductor are adjusted by lowering the distance between them to neutralize the magnetic field of the bifilar. Because the net transient magnetic field is drastically reduced, the plasma-conductor mutual inductance is near zero during current rise and decay. The inductance-free (L ∼ 2 nH) 35 cm-long Z pinches in a 3.1 mm-diameter argon-filled alumina capillary with current rise and decay times of 15 ns, dI/dt > 1012 A/s, and amplitudes up to 17 kA were predicted, realized, and verified to be suitable for pumping soft x-ray Ar+8 lasers. Without the bifilar phenomenon, the 35 cm Z pinches obey a 200 nH inductance that restricts the rise and decay durations of currents to 150 ns. The 35 cm Z pinches with 2 nH inductance generated 46.9 nm laser pulses with up to 4 μJ of energy and a beam divergence of 2 mrad at a low operating voltage of 35–45 kV, compared to 0.1–0.8 MV for similar lasers. The bifilar method could find applications in many research and technological fields, where the rise and decay times of discharge currents play a key role.
- Open Access
- 1 January 2021
- Published by University of Szeged
- p. 118-124
Nagy intenzitású ultraibolya lézerekkel keltett plazmák kontrasztfüggő abszorpciója és dinamikája
- 1 January 2021
- Published by University of Szeged
- p. 118-124
Open AccessNagy intenzitású ultraibolya lézerekkel keltett plazmák kontrasztfüggő abszorpciója és dinamikája
- Open Access
- 1 January 2021
- Published by University of Szeged
- p. 181-187
Status of short-pulse KrF amplifier research and development at HILL, Szeged
- 1 January 2021
- Published by University of Szeged
- p. 181-187
Open AccessStatus of short-pulse KrF amplifier research and development at HILL, Szeged
- 1 January 2021
- Published by University of Szeged
- p. 39-44
Soft X-ray Ar +8 lasers and wake-field electron accelerators by using low-current capillary Z-pinches
- 1 January 2021
- Published by University of Szeged
- p. 39-44
Soft X-ray Ar +8 lasers and wake-field electron accelerators by using low-current capillary Z-pinches
- Open Access
- 1 April 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (4) , 043001
Short-pulse KrF amplifier using spatially tunable x-ray preionization
The small saturation energy density of excimers requires amplifiers of large cross sections for amplification of short pulses of already medium power. Homogeneous excitation of large volumes of fluorine-based gas mixtures by discharge pumping is a critical interplay of the properties of both pumping and preionization, generally necessitating an intense spatially and temporally controlled x-ray preionization. In the present realization, the stringent intensity requirements of preionization are fulfilled by reducing the pulse duration of the x-ray flash to ∼16 ns and by positioning the x-ray source in the near vicinity of the active volume. It is proven both theoretically and experimentally that by proper choice of the positions of two cylindrical x-ray guns, the spatial distribution of preionization can be tuned to (and around) the optimum distribution. In this way, the spatial distribution of the discharge can also be controlled, giving a practical method to compensate for eventual inhomogenities of the E-field of excitation and to tune the discharge to the desired geometry. In this paper, design considerations and experimental realization of a KrF excimer amplifier of ∼5 × 4 cm2 cross section and a spatially tunable x-ray preionization are presented.
- 1 April 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (4) , 043001
Open AccessShort-pulse KrF amplifier using spatially tunable x-ray preionization
The small saturation energy density of excimers requires amplifiers of large cross sections for amplification of short pulses of already medium power. Homogeneous excitation of large volumes of fluorine-based gas mixtures by discharge pumping is a critical interplay of the properties of both pumping and preionization, generally necessitating an intense spatially and temporally controlled x-ray preionization. In the present realization, the stringent intensity requirements of preionization are fulfilled by reducing the pulse duration of the x-ray flash to ∼16 ns and by positioning the x-ray source in the near vicinity of the active volume. It is proven both theoretically and experimentally that by proper choice of the positions of two cylindrical x-ray guns, the spatial distribution of preionization can be tuned to (and around) the optimum distribution. In this way, the spatial distribution of the discharge can also be controlled, giving a practical method to compensate for eventual inhomogenities of the E-field of excitation and to tune the discharge to the desired geometry. In this paper, design considerations and experimental realization of a KrF excimer amplifier of ∼5 × 4 cm2 cross section and a spatially tunable x-ray preionization are presented.
- Open Access
- 9 January 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 167, 04001
Plasma Mirrors for Cleaning Laser Pulses from the Infrared to the Ultraviolet
Ultrashort laser pulses are generally preceded by prepulses which - in case of high main pulse intensities - may generate preplasmas on solid surfaces, thus making the initial conditions for the interactions ambiguous. Infrared laser systems applied successfully, with high efficiency self-induced plasma mirrors for improving the contrast of the beam. Short wavelength laser beams however have a larger critical density in the plasma, and due to their deeper penetration the absorption is higher, the reflectivity, and the corresponding plasma mirror efficiency is lower. We show herewith that with carefully planned boundary conditions plasma mirrors can reach up to 70% efficiency even for KrF laser radiation. Our observations can be qualitatively explained by the classical Drude model. The high reflectivity allows the use of plasma mirrors even after the final amplification or before the last amplifier. Different arrangement proposals for its integration to our high power KrF laser system are given as well.
- 9 January 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 167, 04001
Open AccessPlasma Mirrors for Cleaning Laser Pulses from the Infrared to the Ultraviolet
Ultrashort laser pulses are generally preceded by prepulses which - in case of high main pulse intensities - may generate preplasmas on solid surfaces, thus making the initial conditions for the interactions ambiguous. Infrared laser systems applied successfully, with high efficiency self-induced plasma mirrors for improving the contrast of the beam. Short wavelength laser beams however have a larger critical density in the plasma, and due to their deeper penetration the absorption is higher, the reflectivity, and the corresponding plasma mirror efficiency is lower. We show herewith that with carefully planned boundary conditions plasma mirrors can reach up to 70% efficiency even for KrF laser radiation. Our observations can be qualitatively explained by the classical Drude model. The high reflectivity allows the use of plasma mirrors even after the final amplification or before the last amplifier. Different arrangement proposals for its integration to our high power KrF laser system are given as well.
- 17 August 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (17) , 20791-20797
Improvement of the temporal and spatial contrast of the nonlinear Fourier-filter
Recently a novel method called nonlinear Fourier-filtering was suggested for temporal and spatial cleaning of high-brightness laser pulses. In this paper experimental demonstration of the associated spatial filtering of this method and significant improvement of the temporal filtering feature are presented. The formerly found limit of ~103 for the temporal contrast improvement is identified as diffraction effects caused by the limited numerical aperture of imaging. It is shown by numerical simulation that proper apodization of the object can lead to sufficiently higher limit (>108). Using an advanced experimental arrangement the improvement of >2 orders of magnitude is experimentally verified in the ultraviolet and an indirect proof is presented that the background caused by the optical arrangement is reduced below 10−7.
- 17 August 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (17) , 20791-20797
Improvement of the temporal and spatial contrast of the nonlinear Fourier-filter
Recently a novel method called nonlinear Fourier-filtering was suggested for temporal and spatial cleaning of high-brightness laser pulses. In this paper experimental demonstration of the associated spatial filtering of this method and significant improvement of the temporal filtering feature are presented. The formerly found limit of ~103 for the temporal contrast improvement is identified as diffraction effects caused by the limited numerical aperture of imaging. It is shown by numerical simulation that proper apodization of the object can lead to sufficiently higher limit (>108). Using an advanced experimental arrangement the improvement of >2 orders of magnitude is experimentally verified in the ultraviolet and an indirect proof is presented that the background caused by the optical arrangement is reduced below 10−7.
- Open Access
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (8) , 083101
Plasma mirrors for short pulse KrF lasers
It is demonstrated for the first time that plasma mirrors can be successfully applied for KrF laser systems. High reflectivity up to 70% is achieved by optimization of the beam quality on the plasma mirror. The modest spectral shift and the good reflected beam quality allow its applicability for high power laser systems for which a new arrangement is suggested.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (8) , 083101
Open AccessPlasma mirrors for short pulse KrF lasers
It is demonstrated for the first time that plasma mirrors can be successfully applied for KrF laser systems. High reflectivity up to 70% is achieved by optimization of the beam quality on the plasma mirror. The modest spectral shift and the good reflected beam quality allow its applicability for high power laser systems for which a new arrangement is suggested.
- Open Access
- 7 June 2016
- Published by IOP Publishing in Laser Physics Letters
- Vol. 13 (7) , 075301
Improvement of the temporal and spatial contrast of high-brightness laser beams
A novel method is suggested for temporal and spatial cleaning of high-brightness laser pulses, which seems more energy-scalable than that based on crossed polarizers and offers better contrast improvement compared to the plasma mirror technique. The suggested arrangement utilizes nonlinear modulation of the beam in the Fourier-plane leading both to directional and to temporal modulation. By the use of a 'conjugate' aperture arrangement before and after the nonlinear spatial selector, intensity dependent transmission is obtained; simultaneous temporal and spatial filtering can be realized both for amplitude and phase modulation. In the case of phase modulation introduced by plasma generation in noble gases the experimental observations are in good agreement with the theory; demonstrating >103 improvement in the temporal contrast, ~40% throughput, associated with effective spatial filtering. Due to the broad spectral and power durability of the optical arrangement used here, the method is widely applicable for energetic beams even of UV wavelengths, where most of the former techniques have limited throughput.
- 7 June 2016
- Published by IOP Publishing in Laser Physics Letters
- Vol. 13 (7) , 075301
Open AccessImprovement of the temporal and spatial contrast of high-brightness laser beams
A novel method is suggested for temporal and spatial cleaning of high-brightness laser pulses, which seems more energy-scalable than that based on crossed polarizers and offers better contrast improvement compared to the plasma mirror technique. The suggested arrangement utilizes nonlinear modulation of the beam in the Fourier-plane leading both to directional and to temporal modulation. By the use of a 'conjugate' aperture arrangement before and after the nonlinear spatial selector, intensity dependent transmission is obtained; simultaneous temporal and spatial filtering can be realized both for amplitude and phase modulation. In the case of phase modulation introduced by plasma generation in noble gases the experimental observations are in good agreement with the theory; demonstrating >103 improvement in the temporal contrast, ~40% throughput, associated with effective spatial filtering. Due to the broad spectral and power durability of the optical arrangement used here, the method is widely applicable for energetic beams even of UV wavelengths, where most of the former techniques have limited throughput.