TBThierry Boileau

Thierry Boileau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thierry Boileau has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Contribution à la continuité de service des actionneurs synchrones à aimants permanents. Tolérance au défaut de capteur mécanique. Détection de Défauts Electriques

    by Thierry Boileau

    Dans les systèmes embarqués, les actionneurs électriques remplacent de plus en plus les actionneurs hydrauliques pour des raisons de compacité et de manœuvrabilité. Cependant, il est nécessaire que ces actionneurs électriques soient au moins aussi fiables ou disponibles que leurs homologues hydrauliques. Il faut donc choisir les topologies d'alimentation et d'entraînement adaptées pour ces actionneurs de sorte que le système d'actionnement puisse être reconfiguré en cas de défaillance dans la chaîne de conversion électromécanique. Pour qu'en cas d'apparition d'une panne, la continuité de service puisse être assurée, il est important que différents types de défaut d'un actionneur puisse être détectés à temps. Dans ce mémoire nous avons développé deux aspects de la continuité de service des machines synchrones à aimants permanents. Le premier concerne la commande sans capteur des actionneurs synchrones à aimants permanents, avec l’amélioration de sa robustesse, puis ensuite nous montrons comment cette commande peut-être utilisée de façon fiable pour assurer la continuité de service en cas de perte du capteur mécanique. Le deuxième aspect abordé est la détection de défaut d'isolation inter-spires des bobines statoriques des machines synchrones à aimants permanents commandées par un onduleur de tension en régulation de courant ou en régulation de vitesse. Dans un premier temps nous proposons un modèle de machine présentant le type de défaut à détecter et en déduisons deux méthodes. Ces deux méthodes exploitent le déséquilibre de la machine, elles sont vérifiées expérimentalement. Une troisième méthode basée sur l’estimation de résistance est présentée. Ces trois méthodes sont des méthodes fonctionnant « en ligne » et ne nécessitant pas de capteur supplémentaire par rapport à une commande classique

  • Open Access

    Novel Method of Estimating Iron Loss Equivalent Resistance of Laminated Core Winding at Various Frequencies

    by Maxime Colin, Thierry Boileau, Noureddine Takorabet, Stéphane Charmoille

    Electromagnetic and magnetic devices are increasingly prevalent in sectors such as transportation, industry, and renewable energy due to the ongoing electrification trend. These devices exhibit nonlinear behavior, particularly under signals rich in harmonics. They require precise and appropriate modeling for accurate sizing. Identifying model-specific parameters, which depend on frequency, is crucial. This article focuses on a specific frequency range where a circuit model with series resistance and inductance, along with a parallel resistance to account for iron losses (Riron), is applicable. While the determination of series elements is well documented, the determination of Riron remains complex and debated, with traditional methods neglecting operating conditions such as magnetic saturation. To address these limitations, an innovative experimental method is proposed, comprising two main steps: determining the complex impedance of the magnetic device and extracting Riron from the model. This method aims to provide a more precise and representative estimation of Riron, improving the reliability and accuracy of electromagnetic and magnetic device simulations and designs. The obtained values of the iron loss equivalent resistance are different by at least 300% than those obtained by an impedance analyzer. The proposed method is expected to advance the understanding and modeling of losses in electromagnetic and magnetic devices, offering more robust tools for engineers and researchers in optimizing device performance and efficiency.


  • PMASynRM Local Demagnetization Fault Detection Using Targeted Harmonic Excitation

    by Jérémy Creux, Najla Haje Obeid, Thierry Boileau, Farid Meibody-Tabar

    Permanent Magnet Assisted Synchronous Reluctance Motors (PMASynRM) are high energy density topologies, widely used in the automotive industry. However, their very good performances and efficiencies can be severely impaired by irreversible demagnetization faults of their rare- earth magnets. The aim of this work is to reliably detect local demagnetization faults in these machines. For this purpose, we used demagnetization frequency signatures of a baseline traction PMASynRM and based our diagnosis on high-order harmonic component behavior. Due to the low magnitude of these frequency features it may be difficult to identify the fault with a reliable and robust approach, therefore, a harmonic excitation scheme has been proposed to exacerbate local low severity demagnetization fault signatures. Finite Element (FE) modeling and analysis have been used to develop the method principles. Thus, based on previous findings, we prototype a faulty PMASynRM with a local demagnetization fault in the rotor which helped us experimentally validate our detection approach interests using search coils. Experimental results show that the proposed harmonic excitation strategy amplifies fault features while taking them out of the noise. Therefore, the proposed fault indicator is easier to assess, with a more sensible detection. Further works aim at exploring the method sensitivity to machine speed and operating point, while using machine voltages frequency content for the diagnosis.


  • Open Access

    Online High Frequency Impedance Identification Method of Inverter-Fed Electrical Machines for Stator Health Monitoring

    by Jérémy Creux, Najla Haje Obeid, Thierry Boileau, Farid Meibody-Tabar

    In electric powertrain traction applications, the adopted trend to improve the performance and efficiency of electromechanical power conversion systems is to increase supply voltages and inverter switching frequencies. As a result, electrical machine conductors are subjected to ever-increasing electrical stresses, leading to premature insulation degradation and eventual short-circuits. Winding condition monitoring is crucial to prevent such critical failures. Based on the scientific literature, several methods can be used for early identification of aging. A first solution is to monitor partial discharges. This method requires the use of a specific measurement device and an undisturbed test environment. A second solution is to monitor the inter-turn winding capacitance, which is directly related to the condition of the insulation and can cause a change in the stator impedance behavior. Several approaches can be used to estimate or characterize this impedance behavior. They must be performed on a machine at standstill, which limits their application. In this paper, a new characterization method is proposed to monitor the high-frequency stator impedance evolution of voltage source inverter-fed machines. This method can be applied at any time without removing the machine from its operating environment. The range and accuracy of the proposed frequency characterization depend in particular on the supply voltage level and the bandwidth of the measurement probes. The effects of parameters such as temperature, switching frequency, and DC voltage amplitude on the impedance characteristic were also studied and will be presented. Tests carried out on an automotive traction machine have shown that the first two series and parallel resonances of the high-frequency impedance can be accurately identified using the proposed technique. Therefore, by monitoring these resonances, it is possible to predict the aging rate of the conductor.


  • Open Access

    A New Coupled Approach for Enthalpy Pumping Consideration in a Free Piston Stirling Engine (FPSE)

    by Mahdi Majidniya, Mohamed Tahar Mabrouk, Abdelhamid Kheiri, Benjamin Remy, Thierry Boileau

    One group of losses that can considerably affect the performance of Free Piston Stirling Engines’ (FPSE) is the enthalpy pumping and the shuttle effect, which are due to the gap standing between the cylinder and the displacer. The shuttle effect is induced by the periodic displacer motion between the hot and the cold sources. The enthalpy pumping, which is the subject of the present study, is due to the short-circuit-like flow between the hot and cold spaces. To study these losses, first, a fine nonlinear dynamic model of the FPSE is developed and validated. Then, to study the enthalpy pumping based on that, a coupled model (for the first time) and a decoupled model are presented. The difference between the two models is that the first one provides a dynamic and a thermic linkage between the Stirling and loss model, while the second one studies them separately. The effect of the gap size on both loss models was investigated. The coupled and decoupled modeling results were quite different due to the considerable effect of the enthalpy pumping on the FPSE response. The results showed that the enthalpy pumping in the decoupled model exceeds the total output power when the gap exceeds 30 μm, and when the gap exceeds 70 μm, the enthalpy pumping is around ten times larger than the output power. In contrast, the enthalpy pumping in the coupled model is always less than the output power, which is logical. Thus, the coupled one was presented as the adapted model that should be considered for further FPSE studies.


  • Influencing Parameters on Discharge Bearing Currents in Inverter-Fed Induction Motors

    by Thibaud Plazenet, Thierry Boileau, Cyrille Caironi Caironi, Babak Nahid-Mobarakeh

    This paper investigates discharge bearing currents in inverter-fed electric motors. Industrial reports indicate that among prevalent bearing failures, bearing currents are one of the influent drivers leading to a variety of tribological issues and premature wear in bearings. While the root-causes of bearing currents have been extensively reported over the years, the response of bearing under voltage stress and the factors that influence bearing endangerment through electric discharges have been far less studied. An online measurement of the bearing voltage is proposed on a motor test-bench to estimate both the discharge activity and the energy of the discharges. The designed test bed allows reproduction of representative bearing currents leading to electrical micropitting. This paper presents extensive measurements results that highlight the critical operating conditions and parameters that worsen the discharge phenomenon inside bearings. Testing protocols are performed to quantify the influence of each parameter separately. While the bearing voltage magnitude play a significant role in the discharge phenomenon, other parameters such as successive startups, bearing temperature, and type of grease deserve appropriate investigations to avoid or mitigate the well-known shortened bearing life under inverter operation.


  • Employing Fault Currents in the Reliability Analysis of Motor Drives

    by Saleh A. M. Saleh, Emre Ozkop, M. S. Ayas, Thierry Boileau, Babak Nahid-Mobarakeh

    This paper presents a method to include fault currents in the reliability analysis of motor drives. The presented method is based on formulating a fault current matrix (FCM), the elements of which are values of the currents flowing in all parts of a motor drive. The FCM is processed using the principle component analysis (PCA) to determine the pattern of variations in all currents due to any failure event. The output of the PCA is used to determine the failure rates for all parts of a motor drive. Determined failure rates can provide a tool to set an adequate action (mitigation, maintenance, or shut down) to ensure a reliable and a safe operation during and post any failure events experienced by the motor drive. The validity and accuracy of the PCA-FCM method are verified by employing it in the reliability analysis of different motor drives with different ratings. Results demonstrate the advantages of including fault currents in setting adequate actions in response to possible failure events.


  • Top Cited Papers

    A Comprehensive Study on Shaft Voltages and Bearing Currents in Rotating Machines

    by Thibaud Plazenet, Thierry Boileau, Cyrille Caironi, Babak Nahid-Mobarakeh

    This article puts into perspective the state-of-the art knowledge on bearing currents and diagnosis tools which rely on shaft voltages and bearing currents phenomena. Today, shaft signals measurements are progressively included in predictive health monitoring of large turbo and hydro generators. In addition, bearing fault diagnosis through shaft signals have recently gained some attention to improve reliability and estimation of the Remaining Useful Life (RUL) in electrical drives. The main objective of this paper is to provide diagnosticians with a broad overview of the current trends in fault diagnosis through shaft signals. Therefore, the study presents a critical review of the measurements methods, advantages and disadvantages of fault diagnosis methods and suggests future possible enhancements for bearing health monitoring through shaft signals.


  • Signal processing tools for non-stationary signals detection

    by Thibaud Plazenet, Thierry Boileau, Cyrille Caironi, Babak Nahid-Mobarakeh

    In this paper we aim to compare the abilities and performances of signal processing tools to detect non-stationary signals coming from condition monitoring of electrical machines. From the vast amount of available tools, we focus on existing signal processing methods suitable for real applications for non-stationarities tracking and quantification over time which is particularly interesting in fault diagnosis. First, we assess the spectral kurtosis, a tool that gained much attention because of his capability to characterize transients masked by strong noises. In order to detect non-stationarities, other methods are evaluated such as the spectral subtraction through the short time Fourier transform or the Wiener filtering which can remove stationary components. The analytical framework of each tool is first presented. Non-stationary tests signals based on properties of vibration signals of bearings are proposed to compare effectiveness, advantages and drawbacks of each methods for non-stationarities detection. The purpose is to select a method that is best suited for each type of non-stationarity in order to improve the reliability of the detection.


  • Early Intermittent Interturn Fault Detection and Localization for a Permanent Magnet Synchronous Motor of Electrical Vehicles Using Wavelet Transform

    by Najla Haje Obeid, Alexandre Battiston, Thierry Boileau, Babak Nahid-Mobarakeh

    In order to improve hybrid and electrical vehicles functional safety and to avoid sudden failures, it is important to develop reliable and robust on-board diagnostics (OBD). This paper discusses the stator incipient fault diagnosis and monitoring of a permanent magnet synchronous motor for hybrid and electrical vehicles. Incipient stator fault appears as intermittent interturn faults. Studying this phenomenon had shown that it generates specific distortions in the statoric currents as well as in the reference voltages. The fault monitoring method is based on the identification of these specific distortions and on the localization of the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.