Pavel Alekseevich Nikitin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pavel Alekseevich Nikitin has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Boris A. Knyazev
Budker Institute of Nuclear Physics SB RAS, 630090 Novosibirsk, Russia
8 shared publications - Vasiliy Valerievich Gerasimov
Novosibirsk State University, Novosibirsk, Russia
6 shared publications - Ildus Shevketovich Khasanov
Russian Academy of Sciences
3 shared publications V. B. Voloshinov
Faculty of Physics, Moscow State University
3 shared publicationsV.B. Voloshinov
Lomonosov Moscow State University, Moscow, Russia
3 shared publications- Vitalii B. Voloshinov
Department of Physics, Lomonosov Moscow State University, 119991 Moscow, Russia
3 shared publications
Latest Publications
- 1 September 2025
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 92 (9)
Parameter estimation of an acousto-optic focusing device for visible radiation
Subject of study . An acousto-optic (AO) focusing device using linearly frequency-modulated ultrasonic waves is studied. Aim of study. The parameters of the AO focusing device are determined to estimate the aberrations introduced by it. Method. AO interactions in the low-diffraction-efficiency regime are modeled numerically. Main results. A model that accounts for the length of the AO interaction and the diffraction effects is developed. The results show that the focal spot is a narrow strip with a strongly asymmetric structure, and the wavefront within the spot is tilted by approximately 4° relative to the wavefront of the incident beam. In the case of oblique incidence of radiation on the focusing device, the spot size reduces by a factor of approximately 2; that is, it reduces to 17 µm at the 84% level of the energy concentration function. Further, the focal spot structure becomes symmetric. Practical significance. The obtained results can be used in the development of adaptive optical systems.
- 1 September 2025
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 92 (9)
Parameter estimation of an acousto-optic focusing device for visible radiation
Subject of study . An acousto-optic (AO) focusing device using linearly frequency-modulated ultrasonic waves is studied. Aim of study. The parameters of the AO focusing device are determined to estimate the aberrations introduced by it. Method. AO interactions in the low-diffraction-efficiency regime are modeled numerically. Main results. A model that accounts for the length of the AO interaction and the diffraction effects is developed. The results show that the focal spot is a narrow strip with a strongly asymmetric structure, and the wavefront within the spot is tilted by approximately 4° relative to the wavefront of the incident beam. In the case of oblique incidence of radiation on the focusing device, the spot size reduces by a factor of approximately 2; that is, it reduces to 17 µm at the 84% level of the energy concentration function. Further, the focal spot structure becomes symmetric. Practical significance. The obtained results can be used in the development of adaptive optical systems.
- 1 April 2025
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 19 (2) , 465-469
On Optimal Conditions for Generation of Terahertz Surface Plasmon-Polaritons by the End-Fire Coupling Technique
The results of an experimental study of the generation of surface plasmon-polaritons in the terahertz range are presented. The end-fire coupling technique has been used for generation, when the beam is focused on the metal–dielectric interface. It has been found that at normal beam incidence the efficiency of plasmon-polaritons generation is maximum and the half-width of the dependence of the generation efficiency on the angle of radiation incidence in the sample plane is 6.0° ± 0.5°. It is shown that the generation efficiency has a maximum at a certain shift of the center of the incident beam relative to the metal–dielectric interface. The half-width of this maximum is 590 ± 50 μm, which is consistent with theory within the error limits.
- 1 April 2025
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 19 (2) , 465-469
On Optimal Conditions for Generation of Terahertz Surface Plasmon-Polaritons by the End-Fire Coupling Technique
The results of an experimental study of the generation of surface plasmon-polaritons in the terahertz range are presented. The end-fire coupling technique has been used for generation, when the beam is focused on the metal–dielectric interface. It has been found that at normal beam incidence the efficiency of plasmon-polaritons generation is maximum and the half-width of the dependence of the generation efficiency on the angle of radiation incidence in the sample plane is 6.0° ± 0.5°. It is shown that the generation efficiency has a maximum at a certain shift of the center of the incident beam relative to the metal–dielectric interface. The half-width of this maximum is 590 ± 50 μm, which is consistent with theory within the error limits.
- 1 February 2025
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 92 (2) , 76-81
Influence of the distance between sections of a phased ultrasound transducer on the number of resolvable elements in an acousto-optic deflector
Subject of study. This study investigated an acousto-optic (AO) deflector based on an optically isotropic medium using a sectioned phased ultrasound transducer. Aim of study. The aim of this study was to determine the optimal gap between sections of the ultrasound transducer to implement an efficient terahertz radiation deflector. Method. AO interaction was numerically modeled using the low-diffraction-efficiency approximation. Main results. The influence of the gap between sections and the number of sections of the ultrasound transducer on the number of resolvable elements decreases as the number of sections increases and does not exceed 10%. Practical significance. The key criteria for selecting the optimal gap between sections of the ultrasound transducer for an AO deflector are the diffraction efficiency and the angular separation of radiation beams at the device output.
- 1 February 2025
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 92 (2) , 76-81
Influence of the distance between sections of a phased ultrasound transducer on the number of resolvable elements in an acousto-optic deflector
Subject of study. This study investigated an acousto-optic (AO) deflector based on an optically isotropic medium using a sectioned phased ultrasound transducer. Aim of study. The aim of this study was to determine the optimal gap between sections of the ultrasound transducer to implement an efficient terahertz radiation deflector. Method. AO interaction was numerically modeled using the low-diffraction-efficiency approximation. Main results. The influence of the gap between sections and the number of sections of the ultrasound transducer on the number of resolvable elements decreases as the number of sections increases and does not exceed 10%. Practical significance. The key criteria for selecting the optimal gap between sections of the ultrasound transducer for an AO deflector are the diffraction efficiency and the angular separation of radiation beams at the device output.
- Open Access
Evaluation of the Acousto-Optic Figure of Merit and the Maximum Value of the Elasto-Optic Constant of Liquids
The elasto-optic properties of liquids on the basis of the first principles of acousto-optics were theoretically investigated. A relationship for calculating the elasto-optic constant of liquids using only the refractive index was obtained. The refractive index values corresponding to the maximum elasto-optic constant for polar and nonpolar liquids were determined. Calculations for about 100 liquids were performed and compared with known experimental data. This study significantly extends our understanding of the acousto-optic effect and has practical applications for predicting the elasto-optic constant of a liquid and estimating its wavelength dispersion.
Open AccessEvaluation of the Acousto-Optic Figure of Merit and the Maximum Value of the Elasto-Optic Constant of Liquids
The elasto-optic properties of liquids on the basis of the first principles of acousto-optics were theoretically investigated. A relationship for calculating the elasto-optic constant of liquids using only the refractive index was obtained. The refractive index values corresponding to the maximum elasto-optic constant for polar and nonpolar liquids were determined. Calculations for about 100 liquids were performed and compared with known experimental data. This study significantly extends our understanding of the acousto-optic effect and has practical applications for predicting the elasto-optic constant of a liquid and estimating its wavelength dispersion.
- 1 June 2024
- Published by Allerton Press in Optoelectronics, Instrumentation and Data Processing
- Vol. 60 (3) , 349-355
Analytical Angular–Frequency Dependence for an Acousto-Optic Deflector Using a Sectioned Ultrasound Transducer
Acousto-optic terahertz radiation deflectors based on an optically isotropic medium are characterized by a low number of resolved light spots. A significan
- 1 June 2024
- Published by Allerton Press in Optoelectronics, Instrumentation and Data Processing
- Vol. 60 (3) , 349-355
Analytical Angular–Frequency Dependence for an Acousto-Optic Deflector Using a Sectioned Ultrasound Transducer
Acousto-optic terahertz radiation deflectors based on an optically isotropic medium are characterized by a low number of resolved light spots. A significan
- 28 November 2023
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 87 (11) , 1755-1759
Simulation of Acousto-Optic Deflector of Terahertz Radiation with a Four-Sectioned Ultrasound Transducer
The possibility of improving the characteristics of an acousto-optic deflector of terahertz radiation based on liquefied SF6 gas by sectioning the ultrasou
- 28 November 2023
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 87 (11) , 1755-1759
Simulation of Acousto-Optic Deflector of Terahertz Radiation with a Four-Sectioned Ultrasound Transducer
The possibility of improving the characteristics of an acousto-optic deflector of terahertz radiation based on liquefied SF6 gas by sectioning the ultrasou
- Open Access
Optical Characterization of Thin Films by Surface Plasmon Resonance Spectroscopy Using an Acousto-Optic Tunable Filter
The paper presents the application of the acousto-optic tunable filter (AOTF) in surface plasmon resonance (SPR) spectroscopy to measure the optical thickness of thin dielectric coatings. The technique presented uses combined angular and spectral interrogation modes to obtain the reflection coefficient under the condition of SPR. Surface electromagnetic waves were excited in the Kretschmann geometry, with the AOTF serving as a monochromator and polarizer of light from a white broadband radiation source. The experiments highlighted the high sensitivity of the method and the lower amount of noise in the resonance curves compared with the laser light source. This optical technique can be implemented for nondestructive testing in the production of thin films in not only the visible, but also the infrared and terahertz ranges.
Open AccessOptical Characterization of Thin Films by Surface Plasmon Resonance Spectroscopy Using an Acousto-Optic Tunable Filter
The paper presents the application of the acousto-optic tunable filter (AOTF) in surface plasmon resonance (SPR) spectroscopy to measure the optical thickness of thin dielectric coatings. The technique presented uses combined angular and spectral interrogation modes to obtain the reflection coefficient under the condition of SPR. Surface electromagnetic waves were excited in the Kretschmann geometry, with the AOTF serving as a monochromator and polarizer of light from a white broadband radiation source. The experiments highlighted the high sensitivity of the method and the lower amount of noise in the resonance curves compared with the laser light source. This optical technique can be implemented for nondestructive testing in the production of thin films in not only the visible, but also the infrared and terahertz ranges.
- 1 February 2023
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 90 (2) , 88-92
Simulation of an acousto-optic deflector of terahertz radiation based on a sectioned ultrasound transducer
Subject of study. The acousto-optic diffraction features of terahertz radiation by an ultrasonic field with periodic inhomogeneity are theoretically evaluated in this study. Aim of study. This study aims to identify the optimal parameters for implementing an effective terahertz radiation deflector. Method. Liquefied sulfur hexafluoride gas is selected as the interaction medium to enhance the energy efficiency of the deflector. Additionally, the application of a sectioned phased ultrasound transducer is proposed to increase the number of resolvable light spots. Main results. The features of the acoustic field generated by the transducer are demonstrated. Analytical relations are derived for the main parameters of the acousto-optic deflector. Practical significance. A possible fivefold increase in the number of resolvable spots compared with an acousto-optic deflector based on a single-section transducer of the same length is demonstrated.
- 1 February 2023
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 90 (2) , 88-92
Simulation of an acousto-optic deflector of terahertz radiation based on a sectioned ultrasound transducer
Subject of study. The acousto-optic diffraction features of terahertz radiation by an ultrasonic field with periodic inhomogeneity are theoretically evaluated in this study. Aim of study. This study aims to identify the optimal parameters for implementing an effective terahertz radiation deflector. Method. Liquefied sulfur hexafluoride gas is selected as the interaction medium to enhance the energy efficiency of the deflector. Additionally, the application of a sectioned phased ultrasound transducer is proposed to increase the number of resolvable light spots. Main results. The features of the acoustic field generated by the transducer are demonstrated. Analytical relations are derived for the main parameters of the acousto-optic deflector. Practical significance. A possible fivefold increase in the number of resolvable spots compared with an acousto-optic deflector based on a single-section transducer of the same length is demonstrated.
- Open Access
Acousto–Optic Modulation and Deflection of Terahertz Radiation
It is known that one of the ways to increase the energy efficiency of acousto–optic devices is to use ultrasound beams with a higher power density. It has been established experimentally that the use of a partially electroded ultrasonic transducer significantlyincreases the energy efficiency of the acousto–optic modulator of terahertz radiation. In addition, the operation of an acousto–optic deflector of terahertz radiation with the use of a sectioned ultrasound transducer was theoretically investigated. It showed that a deflector of this kind enables one to achieve higher angular resolution.
Open AccessAcousto–Optic Modulation and Deflection of Terahertz Radiation
It is known that one of the ways to increase the energy efficiency of acousto–optic devices is to use ultrasound beams with a higher power density. It has been established experimentally that the use of a partially electroded ultrasonic transducer significantlyincreases the energy efficiency of the acousto–optic modulator of terahertz radiation. In addition, the operation of an acousto–optic deflector of terahertz radiation with the use of a sectioned ultrasound transducer was theoretically investigated. It showed that a deflector of this kind enables one to achieve higher angular resolution.
- Open Access
Optimal Design of an Ultrasound Transducer for Efficient Acousto-Optic Modulation of Terahertz Radiation
Acousto-optic (AO) interaction in the terahertz range was investigated with the use of monolithic ultrasound transducers of various widths. Sulfur hexafluoride (SF) liquefied at a temperature of about 23 °C and a pressure of 25 bar was used as a medium for AO interaction. The angular and frequency bandwidths of effective AO interaction, as well as the diffraction efficiency per 1 W of the driving electric power, were determined. For the first time, a correct comparison of the AO diffraction efficiency in SF with the use of ultrasound transducers with different widths was carried out. In the experiments performed, the highest energy efficiency of the AO modulator was achieved with a transducer with a width of 12 mm.Open AccessOptimal Design of an Ultrasound Transducer for Efficient Acousto-Optic Modulation of Terahertz Radiation
Acousto-optic (AO) interaction in the terahertz range was investigated with the use of monolithic ultrasound transducers of various widths. Sulfur hexafluoride (SF) liquefied at a temperature of about 23 °C and a pressure of 25 bar was used as a medium for AO interaction. The angular and frequency bandwidths of effective AO interaction, as well as the diffraction efficiency per 1 W of the driving electric power, were determined. For the first time, a correct comparison of the AO diffraction efficiency in SF with the use of ultrasound transducers with different widths was carried out. In the experiments performed, the highest energy efficiency of the AO modulator was achieved with a transducer with a width of 12 mm.