Shao-Xin Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shao-Xin Huang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chi Hou Chan
City University of Hong Kong
6 shared publications - Geng-Bo Wu
City University of Hong Kong
5 shared publications - Ka Fai Chan
City University of Hong Kong
5 shared publications - Bao-Jie Chen
State Key Laboratory of Terahertz and Millimeter Waves, Department of Electrical Engineering, City University of Hong Kong, Hong Kong
2 shared publications - Ming-Yao Xia
School of Electronics, Peking University, Beijing, China
2 shared publications - Bao Jie Chen
State Key Laboratory of Terahertz and Millimeter Waves, City University of Hong Kong, Hong Kong, SAR, China
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 3 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-9
3D-printed aberration-free terahertz metalens for ultra-broadband achromatic super-resolution wide-angle imaging with high numerical aperture
Terahertz (THz) lens constitutes a vital component in the THz system. Metasurfaces-based THz metalenses and classical bulky lenses are severely constrained by chromatic/ spherical aberration and the diffraction limit. Consequently, achromatic super-resolution THz lenses are urgently needed. In this study, through translating the required phase distribution into a refractive index (RI) profile with a specific thickness, an innovative approach to designing THz metalenses is proposed and achieved by dielectric gradient metamaterials. The samples fabricated by 3D printing can realize achromatic super focusing with a numerical aperture (NA) of 0.555 from 0.2 to 0.9 THz. Submillimeter features separated by approximately 0.2 mm can be resolved with high precision, such as glass fabric patterns within FR4 panels and fibrous tissue on leaves, with a field of view (FOV) of 90°. Our approach offers a feasible and cost-effective means to implement THz super-resolution imaging, which holds great potential in non-destructive testing and biomedical imaging.
- 3 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-9
Top Cited PapersOpen Access3D-printed aberration-free terahertz metalens for ultra-broadband achromatic super-resolution wide-angle imaging with high numerical aperture
Terahertz (THz) lens constitutes a vital component in the THz system. Metasurfaces-based THz metalenses and classical bulky lenses are severely constrained by chromatic/ spherical aberration and the diffraction limit. Consequently, achromatic super-resolution THz lenses are urgently needed. In this study, through translating the required phase distribution into a refractive index (RI) profile with a specific thickness, an innovative approach to designing THz metalenses is proposed and achieved by dielectric gradient metamaterials. The samples fabricated by 3D printing can realize achromatic super focusing with a numerical aperture (NA) of 0.555 from 0.2 to 0.9 THz. Submillimeter features separated by approximately 0.2 mm can be resolved with high precision, such as glass fabric patterns within FR4 panels and fibrous tissue on leaves, with a field of view (FOV) of 90°. Our approach offers a feasible and cost-effective means to implement THz super-resolution imaging, which holds great potential in non-destructive testing and biomedical imaging.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 72 (12) , 9082-9094
Enabling Real-Time Near-Field Focusing Imaging With Space-Time-Coding Metasurface Antenna
This article proposes a microwave near-field focus steerable imaging system operating at 22.5 GHz, built upon a space-time-coding metasurface antenna (STCMA), featuring real-time dynamic sensing capabilities. A novel synthetic method is developed to design the required amplitude envelopes, thereby achieving near-field focusing (NFF) for STCMA. By utilizing a field programmable gate array (FPGA) for encoding the operation of meta-atoms, the designed STCMA is capable of rapidly manipulating sub-wavelength NFF beams along the axis parallel to its long side, achieving an optimal focal length of 60 mm. Scattering fields from the illuminated object are collected by an open-ended waveguide for scene mapping. A calibration procedure, in conjunction with a compensation model, is implemented to counteract measurement errors and inconsistencies, thereby enhancing the imaging quality. MATLAB scripts are developed to refresh the data stream through interactions with FPGA and vector network analyzer (VNA), enabling one-dimensional (1-D) real-time detection and characterization of various concealed metal and dielectric objects with a large field of view (FoV) of 90°. The proposed imager is expanded to achieve two-dimensional (2-D) imaging within seconds by incorporating mechanical translation. The proposed study advances the STCMA technology from the level of component design to that of system application and lays the groundwork for future research into metasurface-based super-resolution real-time imaging at higher frequencies.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 72 (12) , 9082-9094
Enabling Real-Time Near-Field Focusing Imaging With Space-Time-Coding Metasurface Antenna
This article proposes a microwave near-field focus steerable imaging system operating at 22.5 GHz, built upon a space-time-coding metasurface antenna (STCMA), featuring real-time dynamic sensing capabilities. A novel synthetic method is developed to design the required amplitude envelopes, thereby achieving near-field focusing (NFF) for STCMA. By utilizing a field programmable gate array (FPGA) for encoding the operation of meta-atoms, the designed STCMA is capable of rapidly manipulating sub-wavelength NFF beams along the axis parallel to its long side, achieving an optimal focal length of 60 mm. Scattering fields from the illuminated object are collected by an open-ended waveguide for scene mapping. A calibration procedure, in conjunction with a compensation model, is implemented to counteract measurement errors and inconsistencies, thereby enhancing the imaging quality. MATLAB scripts are developed to refresh the data stream through interactions with FPGA and vector network analyzer (VNA), enabling one-dimensional (1-D) real-time detection and characterization of various concealed metal and dielectric objects with a large field of view (FoV) of 90°. The proposed imager is expanded to achieve two-dimensional (2-D) imaging within seconds by incorporating mechanical translation. The proposed study advances the STCMA technology from the level of component design to that of system application and lays the groundwork for future research into metasurface-based super-resolution real-time imaging at higher frequencies.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (12) , 803-806
Enhancing Compressive Single-Pixel Imaging With Zig-Zag-Ordered Walsh-Hadamard Light Modulation
Single-pixel imaging (SPI) is empowered to achieve high-quality image reconstruction by utilizing only single-element detectors via compressive sampling in a high-efficiency, low-cost and low-complexity manner. This letter proposes an easy-to-implement demonstration of SPI with zig-zag-ordered Walsh-Hadamard spatial patterns to eliminate artifacts and enhance the image quality of the reconstructed scene. Dual-channel measurements are taken and integrated to improve the signal-to-noise ratio (SNR) and enhance the fidelity of the images. A calibration procedure of the pixels-to-detector ray propagation is experimentally validated to reveal the true reflectance of the scene. Compressive Sensing is incorporated to reconstruct high-fidelity images with sub-Nyquist compression ratios (CRs). Experimental results of the proposed approach demonstrate above 90% correlation with CRs down to 30% in a completely dark environment. This work provides insights for efficient high-fidelity SPI in low-light or low-signal-to-noise-ratio (low-SNR) conditions.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (12) , 803-806
Enhancing Compressive Single-Pixel Imaging With Zig-Zag-Ordered Walsh-Hadamard Light Modulation
Single-pixel imaging (SPI) is empowered to achieve high-quality image reconstruction by utilizing only single-element detectors via compressive sampling in a high-efficiency, low-cost and low-complexity manner. This letter proposes an easy-to-implement demonstration of SPI with zig-zag-ordered Walsh-Hadamard spatial patterns to eliminate artifacts and enhance the image quality of the reconstructed scene. Dual-channel measurements are taken and integrated to improve the signal-to-noise ratio (SNR) and enhance the fidelity of the images. A calibration procedure of the pixels-to-detector ray propagation is experimentally validated to reveal the true reflectance of the scene. Compressive Sensing is incorporated to reconstruct high-fidelity images with sub-Nyquist compression ratios (CRs). Experimental results of the proposed approach demonstrate above 90% correlation with CRs down to 30% in a completely dark environment. This work provides insights for efficient high-fidelity SPI in low-light or low-signal-to-noise-ratio (low-SNR) conditions.
- Open Access
- 3 January 2024
- Published by Springer Nature in Research Square
A hybrid lens to realize electrical real-time super-resolution Imaging
Real-time dynamic super-resolution focusing technology is crucial for various applications, particularly in super-resolution imaging. However, the diffraction limit significantly impedes the achievement of real-time dynamic super-resolution imaging. Prior studies within this domain, such as super-resolution fluorescence imaging and structural illumination microscopy, heavily rely on fluorescent labels and intricate algorithms. This article proposes a novel approach to achieving real-time dynamic super-resolution imaging at microwave frequency by integrating the Mikaelian lens derived from conformal transformation optics with the space-time-coding metasurface antenna. Real-time dynamic super-resolution focusing with a resolution ranging from 0.3λ to 0.4λ is demonstrated at the periphery of the Mikaelian lens. The proposed hybrid lens exhibits the capacity to discern features separated by about one-third of a wavelength with high precision. Our work offers a universal solution for achieving dynamic real-time super-resolution imaging electrically, which can be extended to terahertz waves, visible light, and other wave fields, such as acoustic and flexural waves
- 3 January 2024
- Published by Springer Nature in Research Square
Open AccessA hybrid lens to realize electrical real-time super-resolution Imaging
Real-time dynamic super-resolution focusing technology is crucial for various applications, particularly in super-resolution imaging. However, the diffraction limit significantly impedes the achievement of real-time dynamic super-resolution imaging. Prior studies within this domain, such as super-resolution fluorescence imaging and structural illumination microscopy, heavily rely on fluorescent labels and intricate algorithms. This article proposes a novel approach to achieving real-time dynamic super-resolution imaging at microwave frequency by integrating the Mikaelian lens derived from conformal transformation optics with the space-time-coding metasurface antenna. Real-time dynamic super-resolution focusing with a resolution ranging from 0.3λ to 0.4λ is demonstrated at the periphery of the Mikaelian lens. The proposed hybrid lens exhibits the capacity to discern features separated by about one-third of a wavelength with high precision. Our work offers a universal solution for achieving dynamic real-time super-resolution imaging electrically, which can be extended to terahertz waves, visible light, and other wave fields, such as acoustic and flexural waves
- 17 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (6) , 609-619
Terahertz Multi-Spectral Mueller Matrix Polarimetry on Leaf Using Only Orthogonal-Polarization Measurements
There has been a surge of emphasis on polarimetric imaging modalities recently, in which Mueller matrix polarimetry (MMP) is at the heart of our understanding of polarization properties of an imaged sample. However, the historiography of MMP, predominantly undertaken in optics, largely lost sight of the potential of terahertz radiation on interactions with the imaged samples, especially biological ones. In addition, studies of MMP are generally concerned with intensity-only measurements requiring at least 16 polarization combinations, which dramatically add to the time cost in the process of measurements. The proposed study sets out to examine the complete 4 × 4 MMP from 0.2 to 1 THz using only orthogonal polarizations for two-dimensional (2-D) and 3-D imaging on leaf. A modified THz time domain spectrometer with self-designed linear polarizers is utilized for measurements and data acquisition. The Mueller matrix polar decomposition and Mueller matrix transform are employed to facilitate extraction of polarization characteristics of the imaged leaf. The time-of-flight technique is adopted to assist in the 3-D reconstruction of the leaf. The results demonstrate the effectiveness and feasibility of the novel measurement synthesis approach and the modified system for accurate characterization of the sample. Meanwhile, the findings indicate that MMP is superior in feature extraction as well as contrast enhancement of the sample. The insights gained from this article may be of assistance to the characterization of biological samples with MMP at higher frequencies for future research.
- 17 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (6) , 609-619
Terahertz Multi-Spectral Mueller Matrix Polarimetry on Leaf Using Only Orthogonal-Polarization Measurements
There has been a surge of emphasis on polarimetric imaging modalities recently, in which Mueller matrix polarimetry (MMP) is at the heart of our understanding of polarization properties of an imaged sample. However, the historiography of MMP, predominantly undertaken in optics, largely lost sight of the potential of terahertz radiation on interactions with the imaged samples, especially biological ones. In addition, studies of MMP are generally concerned with intensity-only measurements requiring at least 16 polarization combinations, which dramatically add to the time cost in the process of measurements. The proposed study sets out to examine the complete 4 × 4 MMP from 0.2 to 1 THz using only orthogonal polarizations for two-dimensional (2-D) and 3-D imaging on leaf. A modified THz time domain spectrometer with self-designed linear polarizers is utilized for measurements and data acquisition. The Mueller matrix polar decomposition and Mueller matrix transform are employed to facilitate extraction of polarization characteristics of the imaged leaf. The time-of-flight technique is adopted to assist in the 3-D reconstruction of the leaf. The results demonstrate the effectiveness and feasibility of the novel measurement synthesis approach and the modified system for accurate characterization of the sample. Meanwhile, the findings indicate that MMP is superior in feature extraction as well as contrast enhancement of the sample. The insights gained from this article may be of assistance to the characterization of biological samples with MMP at higher frequencies for future research.
- 29 April 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (10) , 14853-14867
Demonstration of a terahertz multi-spectral 3×3 Mueller matrix polarimetry system for 2D and 3D imaging
Mueller matrix polarimetry (MMP) has been demonstrated and recognized as an effective approach to attaining imaging enhancement as well as revealing polarization properties of an imaged sample. Generally, a minimum of 16 combinations of intensity-only measurements involving both linear and circular polarizations are required to completely and accurately determine the 4 × 4 Mueller matrix (MM) and comprehensively describe the polarization properties of the sample. However, broadband circular polarizations (CP) are rather difficult to obtain for design and fabrication limitations in the terahertz region, which poses a challenge to the acquisition of the 4 × 4 MM. In this circumstance, the 3 × 3 MM degradation using only linear polarizations (LP) is preferred and sufficient for characterization of non-depolarizing samples. In this paper, a multi-spectral 3 × 3 MMP system based on the THz time-domain spectroscopy (THz-TDS) is established from 0.1 to 1 THz. The system demonstrated is capable of fulfilling the accurate determination of the 3 × 3 MM. The Mueller matrix polar decomposition (MMPD), modified to be compatible with the MM degradation, is employed to explore the fine details and properties of the sample. By signal post-processing techniques, the MM elements in the time domain are retrieved, and the time dimension reflecting the depth information facilitates the 3D reconstruction of the sample. This work provides a prototype for 3D imaging of biological samples at higher frequencies in the future.
- 29 April 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (10) , 14853-14867
Demonstration of a terahertz multi-spectral 3×3 Mueller matrix polarimetry system for 2D and 3D imaging
Mueller matrix polarimetry (MMP) has been demonstrated and recognized as an effective approach to attaining imaging enhancement as well as revealing polarization properties of an imaged sample. Generally, a minimum of 16 combinations of intensity-only measurements involving both linear and circular polarizations are required to completely and accurately determine the 4 × 4 Mueller matrix (MM) and comprehensively describe the polarization properties of the sample. However, broadband circular polarizations (CP) are rather difficult to obtain for design and fabrication limitations in the terahertz region, which poses a challenge to the acquisition of the 4 × 4 MM. In this circumstance, the 3 × 3 MM degradation using only linear polarizations (LP) is preferred and sufficient for characterization of non-depolarizing samples. In this paper, a multi-spectral 3 × 3 MMP system based on the THz time-domain spectroscopy (THz-TDS) is established from 0.1 to 1 THz. The system demonstrated is capable of fulfilling the accurate determination of the 3 × 3 MM. The Mueller matrix polar decomposition (MMPD), modified to be compatible with the MM degradation, is employed to explore the fine details and properties of the sample. By signal post-processing techniques, the MM elements in the time domain are retrieved, and the time dimension reflecting the depth information facilitates the 3D reconstruction of the sample. This work provides a prototype for 3D imaging of biological samples at higher frequencies in the future.
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 10 (1) , 74-84
Terahertz Mueller Matrix Polarimetry and Polar Decomposition
Mueller matrix imaging, as one of polarimetric imaging modalities, is an effective tool to achieve imaging enhancement as well as explore fine details of the imaged sample at microwave and optical frequencies. However, little work has been reported at terahertz (THz) frequencies, which could provide an exclusive insight in exploring fine details of biological specimens for their sensitivity to THz absorption due to their various water contents. This paper presents a 0.3 THz polarimetric system for Mueller matrix imaging measurements both in reflection and transmission modes. Two experiments are designed to demonstrate the capability of Mueller matrix theory and its polar decomposition in imaging enhancement and properties characterization. The Structural Similarity Index (SSIM) is employed to serve as the metric for image quality assessment (IQA), by which the performance of the Mueller matrix imaging is evaluated. The SSIM values of the Mueller matrix could reach as high as 0.9~0.98 for the leaf sample and 0.9 for the ITO target respectively while that of the raw polarization images could only stabilize at 0.7~0.9 and 0.2~0.4. Furthermore, the SSIM value of the decomposition parameters for the ITO target could reach nearly 1, the maximum value. The imaging results both in visual and analytical perspectives demonstrate successful system integration at THz band. The work paves the way for our exploration of biomedical imaging of tissues and cells at higher THz frequencies in the immediate future.
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 10 (1) , 74-84
Terahertz Mueller Matrix Polarimetry and Polar Decomposition
Mueller matrix imaging, as one of polarimetric imaging modalities, is an effective tool to achieve imaging enhancement as well as explore fine details of the imaged sample at microwave and optical frequencies. However, little work has been reported at terahertz (THz) frequencies, which could provide an exclusive insight in exploring fine details of biological specimens for their sensitivity to THz absorption due to their various water contents. This paper presents a 0.3 THz polarimetric system for Mueller matrix imaging measurements both in reflection and transmission modes. Two experiments are designed to demonstrate the capability of Mueller matrix theory and its polar decomposition in imaging enhancement and properties characterization. The Structural Similarity Index (SSIM) is employed to serve as the metric for image quality assessment (IQA), by which the performance of the Mueller matrix imaging is evaluated. The SSIM values of the Mueller matrix could reach as high as 0.9~0.98 for the leaf sample and 0.9 for the ITO target respectively while that of the raw polarization images could only stabilize at 0.7~0.9 and 0.2~0.4. Furthermore, the SSIM value of the decomposition parameters for the ITO target could reach nearly 1, the maximum value. The imaging results both in visual and analytical perspectives demonstrate successful system integration at THz band. The work paves the way for our exploration of biomedical imaging of tissues and cells at higher THz frequencies in the immediate future.