Tony J. Akl
Research Subjects
Research Interests
Tony J. Akl has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Anusha A. S.
Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India
1 shared publication - Mohanasankar Sivaprakasam
Indian Institute of Technology Madras
1 shared publication - Preejith Sp
Healthcare Technology Innovation Centre, Indian Institute of Technology, Madras, Chennai 600113, India
1 shared publication - Sarveswaran V.
Sri Ramakrishna Hospital, Coimbatore, India
1 shared publication - Shyam A.
Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India
1 shared publication - Sukumaran P.
Sri Ramakrishna Hospital, Coimbatore, India
1 shared publication
Latest Publications
- 16 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 92-100
Electrodermal Activity Based Pre-surgery Stress Detection Using a Wrist Wearable
Surgery is a particularly potent stressor and the detrimental effects of stress on people undergoing any surgery is indisputable. When left unchecked, the pre-surgery stress adversely impacts people's physical and psychological well-being, and may even evolve into severe pathological states. Therefore, it is essential to identify levels of preoperative stress in surgical patients. This paper focusses on developing an automatic pre- surgery stress detection scheme based on electrodermal activity (EDA). The measurement set up involves a wrist wearable that monitors EDA of a subject continuously in the most non-invasive and unobtrusive manner. Data were collected from 41 subjects (17 females and 24 males, age: 54.8 - 16.8 years (mean - SD)), who subsequently underwent different surgical procedures at the Sri Ramakrishna Hospital, Coimbatore, India. A supervised machine learning algorithm that detects motion artifacts in the recorded EDA data was developed. It yielded an accuracy of 97.83% on a new user dataset. The clean EDA data were further analyzed to determine low, moderate and high levels of stress. A novel localized supervised learning scheme, based on the adaptive partitioning of the dataset was adopted for stress detection. Consequently, the interindividual variability in the EDA due to person-specific factors like the sweat gland density and skin thickness, which may lead to erroneous classification, could be eliminated. The scheme yielded a classification accuracy of 85.06% on a new user data set and proved to be more effective than the general supervised classification model.
- 16 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 92-100
Electrodermal Activity Based Pre-surgery Stress Detection Using a Wrist Wearable
Surgery is a particularly potent stressor and the detrimental effects of stress on people undergoing any surgery is indisputable. When left unchecked, the pre-surgery stress adversely impacts people's physical and psychological well-being, and may even evolve into severe pathological states. Therefore, it is essential to identify levels of preoperative stress in surgical patients. This paper focusses on developing an automatic pre- surgery stress detection scheme based on electrodermal activity (EDA). The measurement set up involves a wrist wearable that monitors EDA of a subject continuously in the most non-invasive and unobtrusive manner. Data were collected from 41 subjects (17 females and 24 males, age: 54.8 - 16.8 years (mean - SD)), who subsequently underwent different surgical procedures at the Sri Ramakrishna Hospital, Coimbatore, India. A supervised machine learning algorithm that detects motion artifacts in the recorded EDA data was developed. It yielded an accuracy of 97.83% on a new user dataset. The clean EDA data were further analyzed to determine low, moderate and high levels of stress. A novel localized supervised learning scheme, based on the adaptive partitioning of the dataset was adopted for stress detection. Consequently, the interindividual variability in the EDA due to person-specific factors like the sweat gland density and skin thickness, which may lead to erroneous classification, could be eliminated. The scheme yielded a classification accuracy of 85.06% on a new user data set and proved to be more effective than the general supervised classification model.