Elena L. Lebedeva
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elena L. Lebedeva has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Egor P. Sobina
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
3 shared publications - Pavel V. Migal
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
3 shared publications - Alena V. Sobina
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
2 shared publications - Elena V. Vostroknutova
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
2 shared publications - Marina F. Kuznetsova
UNIIM—Affiliated branch of the D. I. Mendeleyev
2 shared publications - Tatiana N. Tabatchikova
UNIIM—Affiliated branch of the D. I. Mendeleyev
2 shared publications
Latest Publications
- Open Access
- 19 July 2023
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 19 (3) , 103-127-127
Primary Reference Procedure for Measuring the Mass Fraction and Molar Concentration of Copper and Zinc in Biological Materials by Isotope Dilution Mass Spectrometry
The establishment and control of the metrological characteristics of the determination of trace elements in biological materials is an urgent task due to the wide application of these measurements in medical laboratory diagnostics. In the course of the research, the process of developing a primary reference procedure for measuring the mass fraction and molar concentration of copper and zinc in biological materials by isotope dilution mass spectrometry is presented. The optimal conditions for sample preparation and measurements by isotope dilution and mass spectrometry with inductively coupled plasma are determined in order to increase the accuracy. The sources of uncertainty are studied; the contribution of each source to the uncertainty budget is estimated. During the certification of the developed measurement procedure, the following metrological characteristics were determined: the measurement range of the mass fraction of copper and zinc is from 1 ∙ 10–6 to 1,5 ∙ 10–3 %, the measurement range of the molar concentration of copper and zinc is from 2 to 20 µmol/dm3, the relative expanded measurement uncertainty of the mass fraction of copper is (7.1–7.5) %, the relative expanded uncertainty of the mass fraction of zinc is (8.9–9.2) %, the relative expanded uncertainty of the molar concentration of copper is 8.8 %, the relative expanded uncertainty of the molar concentration of zinc is 8.6 %.The developed procedure is intended to establish the metrological characteristics of reference materials for the composition of lyophilized blood serum and reconstituted lyophilized blood serum, control the accuracy of the measurement results obtained using other procedures (methods) of measuring similar values, perform high-precision measurements of mass fractions and molar concentrations of copper and zinc in lyophilized blood serum and reconstituted lyophilized blood serum for referee purposes.
- 19 July 2023
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 19 (3) , 103-127-127
Open AccessPrimary Reference Procedure for Measuring the Mass Fraction and Molar Concentration of Copper and Zinc in Biological Materials by Isotope Dilution Mass Spectrometry
The establishment and control of the metrological characteristics of the determination of trace elements in biological materials is an urgent task due to the wide application of these measurements in medical laboratory diagnostics. In the course of the research, the process of developing a primary reference procedure for measuring the mass fraction and molar concentration of copper and zinc in biological materials by isotope dilution mass spectrometry is presented. The optimal conditions for sample preparation and measurements by isotope dilution and mass spectrometry with inductively coupled plasma are determined in order to increase the accuracy. The sources of uncertainty are studied; the contribution of each source to the uncertainty budget is estimated. During the certification of the developed measurement procedure, the following metrological characteristics were determined: the measurement range of the mass fraction of copper and zinc is from 1 ∙ 10–6 to 1,5 ∙ 10–3 %, the measurement range of the molar concentration of copper and zinc is from 2 to 20 µmol/dm3, the relative expanded measurement uncertainty of the mass fraction of copper is (7.1–7.5) %, the relative expanded uncertainty of the mass fraction of zinc is (8.9–9.2) %, the relative expanded uncertainty of the molar concentration of copper is 8.8 %, the relative expanded uncertainty of the molar concentration of zinc is 8.6 %.The developed procedure is intended to establish the metrological characteristics of reference materials for the composition of lyophilized blood serum and reconstituted lyophilized blood serum, control the accuracy of the measurement results obtained using other procedures (methods) of measuring similar values, perform high-precision measurements of mass fractions and molar concentrations of copper and zinc in lyophilized blood serum and reconstituted lyophilized blood serum for referee purposes.
- Open Access
- 17 January 2022
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 17 (4) , 65-84-84
Application of direct and indirect methods for determining the mass fraction of the main component in flotation potassium chloride
The article is devoted to the comparison of two approaches to determining the purity of metal salts on the example of a complex in composition object - flotation potassium chloride. The results of determining the mass fraction of the main component (potassium chloride) in flotation potassium chloride obtained by direct (using the coulometric titration method with correction for anions titrated with the determined chloride ion and an excess of cations) and indirect (according to the scheme 100% minus the amount of impurities with regard to their species) methods. It is shown that direct and indirect methods give well consistent results: (96.08 ± 0.17) % and (96.11 ± 0.12) %, respectively. Also, the measurement results obtained using the standard installations considering the uncertainty are well consistent with the certified value of the mass fraction of potassium chloride (96.11 ± 0.11) %, obtained based on an interlaboratory experiment in laboratories that perform measurements in accordance with GOST 20851.3. The feature of the direct and indirect methods implemented in this work is the construction of a model of the chemical composition of the analysed object based on a priori and experimental data using two basic principles when summing up the content of impurities: the conditions of material balance and the principle of electroneutrality.
- 17 January 2022
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 17 (4) , 65-84-84
Open AccessApplication of direct and indirect methods for determining the mass fraction of the main component in flotation potassium chloride
The article is devoted to the comparison of two approaches to determining the purity of metal salts on the example of a complex in composition object - flotation potassium chloride. The results of determining the mass fraction of the main component (potassium chloride) in flotation potassium chloride obtained by direct (using the coulometric titration method with correction for anions titrated with the determined chloride ion and an excess of cations) and indirect (according to the scheme 100% minus the amount of impurities with regard to their species) methods. It is shown that direct and indirect methods give well consistent results: (96.08 ± 0.17) % and (96.11 ± 0.12) %, respectively. Also, the measurement results obtained using the standard installations considering the uncertainty are well consistent with the certified value of the mass fraction of potassium chloride (96.11 ± 0.11) %, obtained based on an interlaboratory experiment in laboratories that perform measurements in accordance with GOST 20851.3. The feature of the direct and indirect methods implemented in this work is the construction of a model of the chemical composition of the analysed object based on a priori and experimental data using two basic principles when summing up the content of impurities: the conditions of material balance and the principle of electroneutrality.
- 1 January 2022
- Published by Voronezh State University in Сорбционные и хроматографические процессы
- Vol. 22 (6) , 856-868
A study of arginine sorption by sulfoethylated chitosan followed by a capillary electrophoresis
- 1 January 2022
- Published by Voronezh State University in Сорбционные и хроматографические процессы
- Vol. 22 (6) , 856-868
A study of arginine sorption by sulfoethylated chitosan followed by a capillary electrophoresis
- Open Access
- 1 January 2017
- Published by Ural Research Institute of Metrology (UNIIM) in Reference materials
- Vol. 13 (1) , 27-36
Development of certified reference material of mineral composition of natural water designed to control of turbidity measurement accuracy
Разработка стандартного образца минерального состава воды природной, предназначенного для контроля точности измерений мутности
- 1 January 2017
- Published by Ural Research Institute of Metrology (UNIIM) in Reference materials
- Vol. 13 (1) , 27-36
Open AccessDevelopment of certified reference material of mineral composition of natural water designed to control of turbidity measurement accuracy
Разработка стандартного образца минерального состава воды природной, предназначенного для контроля точности измерений мутности
- 18 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (12) , 1804-1815
Determination of Antioxidants in Human Skin by Capillary Zone Electrophoresis and Potentiometry
This study reports on the determination of water-soluble antioxidants from human skin by potentiometry and capillary zone electrophoresis. A rapid and simple capillary electrophoretic method was developed for the determination of ascorbic acid, uric acid, and glutathione. The limits of detection were 1.5 µ mol L−1 for uric acid, 4.5 µ mol L−1 for glutathione, and 9 µ mol L−1 for ascorbic acid with spectrophotometric detection at 190 nm. The procedure was used to analyze aqueous extracts from human skin. The results by both methods were in good agreement. Uric acid was shown to be a major component in the extract by capillary zone electrophoresis. The uric acid might also be primarily responsible for the potentiometric signal.
- 18 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (12) , 1804-1815
Determination of Antioxidants in Human Skin by Capillary Zone Electrophoresis and Potentiometry
This study reports on the determination of water-soluble antioxidants from human skin by potentiometry and capillary zone electrophoresis. A rapid and simple capillary electrophoretic method was developed for the determination of ascorbic acid, uric acid, and glutathione. The limits of detection were 1.5 µ mol L−1 for uric acid, 4.5 µ mol L−1 for glutathione, and 9 µ mol L−1 for ascorbic acid with spectrophotometric detection at 190 nm. The procedure was used to analyze aqueous extracts from human skin. The results by both methods were in good agreement. Uric acid was shown to be a major component in the extract by capillary zone electrophoresis. The uric acid might also be primarily responsible for the potentiometric signal.