Fabienne Méducin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fabienne Méducin has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Howard James Stone
University of Cambridge
3 shared publications - Martin Travis Dove
School of Mechanical Engineering Guizhou University of Engineering Science Bijie Guizhou China
3 shared publications - Matthew G. Tucker
Oak Ridge National Laboratory
3 shared publications - Simon A. T. Redfern
Nanyang Technological University
3 shared publications - Samuel Guillot
Department of Physics, UFR Sciences & Techniques, University of Orléans, 1 rue de Chartres, 45100 Orléans, France
2 shared publications Sébastien Serieye
Interfaces, Confinement, Matériaux et Nanostructures (ICMN), Université d'Orléans, CNRS, UMR 7374, 1b rue de la Férollerie, CS 40059, 45071 Orléans Cedex 2, France
2 shared publications
Latest Publications
- 1 June 2017
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 496, 26-34
Interface tuning and stabilization of monoglyceride mesophase dispersions: Food emulsifiers and mixtures efficiency
- 1 June 2017
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 496, 26-34
Interface tuning and stabilization of monoglyceride mesophase dispersions: Food emulsifiers and mixtures efficiency
- 1 May 2017
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 523 (1) , 142-150
Nanostructured monolinolein miniemulsions as delivery systems: Role of the internal mesophase on cytotoxicity and cell internalization
- 1 May 2017
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 523 (1) , 142-150
Nanostructured monolinolein miniemulsions as delivery systems: Role of the internal mesophase on cytotoxicity and cell internalization
- 1 May 2007
- Published by Elsevier in Cement and Concrete Research
- Vol. 37 (5) , 631-638
Calcium silicate hydrates investigated by solid‐state high resolution 1H and 29Si nuclear magnetic resonance
- 1 May 2007
- Published by Elsevier in Cement and Concrete Research
- Vol. 37 (5) , 631-638
Calcium silicate hydrates investigated by solid‐state high resolution 1H and 29Si nuclear magnetic resonance
- 15 September 2005
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 98 (6) , 064905
Temperature measurement in a Paris-Edinburgh cell by neutron resonance spectroscopy
Neutron resonance spectroscopy is demonstrated as a viable and reliable method for the determination of sample temperatures in high-pressure, high-temperature neutron diffraction studies at neutron spallation sources. The technique operates by characterizing the thermally induced Doppler broadening of neutron absorption resonances of heavy nuclei present within the sample assembly observed in transmission. Accuracies of have been readily achieved with data acquisition times of approximately 40 min. It is shown that the temperatures determined by this technique are independent of the sample pressure provided that the sample temperature is kept above the Debye temperature of the material whose resonances are being examined. A short list of candidate resonances for temperature measurement by neutron resonance spectroscopy is presented and suggestions volunteered for the combinations of elements most suitable for temperature measurement based on the experience of the authors.- 15 September 2005
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 98 (6) , 064905
Temperature measurement in a Paris-Edinburgh cell by neutron resonance spectroscopy
Neutron resonance spectroscopy is demonstrated as a viable and reliable method for the determination of sample temperatures in high-pressure, high-temperature neutron diffraction studies at neutron spallation sources. The technique operates by characterizing the thermally induced Doppler broadening of neutron absorption resonances of heavy nuclei present within the sample assembly observed in transmission. Accuracies of have been readily achieved with data acquisition times of approximately 40 min. It is shown that the temperatures determined by this technique are independent of the sample pressure provided that the sample temperature is kept above the Debye temperature of the material whose resonances are being examined. A short list of candidate resonances for temperature measurement by neutron resonance spectroscopy is presented and suggestions volunteered for the combinations of elements most suitable for temperature measurement based on the experience of the authors.- 1 August 2005
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 547 (2-3) , 601-615
Remote determination of sample temperature by neutron resonance spectroscopy
- 1 August 2005
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 547 (2-3) , 601-615
Remote determination of sample temperature by neutron resonance spectroscopy
- 1 July 2004
- Published by Mineralogical Society of America in American Mineralogist: Journal of Earth and Planetary Materials
- Vol. 89 (7) , 981-986
Study of cation order-disorder in MgAl 2 O 4 spinel by in situ neutron diffraction up to 1600 K and 3.2 GPa
The temperature-dependence of the cation distribution in synthetic spinel (MgAl2O4) was investigated using in situ time-of-flight neutron powder diffraction at ISIS, the pulsed-neutron source at the Rutherford Appleton Laboratory. Neutron diffraction patterns of stoichiometric MgAl2O4 were collected on heating from room temperature to ∼1600 K at pressures of ∼2.6 GPa. The cation distribution was determined directly from site occupancies obtained by Rietveld refinement. The equilibrium non-convergent ordering was analyzed using the O’Neill-Navrotsky (1983) thermodynamic model, which fits the observed behavior well over the temperature range of the measurements. Fitting the data between 790 and 1600 K yields α = 31(6) kJ/mol and β = −20(13) kJ/mol in the expression for the free energy of ordering. The high-pressure temperature-dependent behavior, as compared to equivalent ambient-pressure behavior, demonstrates that disordering occurs to a much greater extent in MgAl2O4 at high pressure and that pressure favors disordering toward the inverse structure.
- 1 July 2004
- Published by Mineralogical Society of America in American Mineralogist: Journal of Earth and Planetary Materials
- Vol. 89 (7) , 981-986
Study of cation order-disorder in MgAl 2 O 4 spinel by in situ neutron diffraction up to 1600 K and 3.2 GPa
The temperature-dependence of the cation distribution in synthetic spinel (MgAl2O4) was investigated using in situ time-of-flight neutron powder diffraction at ISIS, the pulsed-neutron source at the Rutherford Appleton Laboratory. Neutron diffraction patterns of stoichiometric MgAl2O4 were collected on heating from room temperature to ∼1600 K at pressures of ∼2.6 GPa. The cation distribution was determined directly from site occupancies obtained by Rietveld refinement. The equilibrium non-convergent ordering was analyzed using the O’Neill-Navrotsky (1983) thermodynamic model, which fits the observed behavior well over the temperature range of the measurements. Fitting the data between 790 and 1600 K yields α = 31(6) kJ/mol and β = −20(13) kJ/mol in the expression for the free energy of ordering. The high-pressure temperature-dependent behavior, as compared to equivalent ambient-pressure behavior, demonstrates that disordering occurs to a much greater extent in MgAl2O4 at high pressure and that pressure favors disordering toward the inverse structure.
- 21 January 2004
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 38 (5) , 1383-1398
Retention of Trace Metals by Solidified/Stabilized Wastes: Assessment of Long-Term Metal Release
Toxic elements found in wastes may have a negative impact on the environment, especially through the contamination of groundwater and plants. To reduce their mobility and availability, French regulations mandate the solidification and stabilization of toxic wastes. Many methods to stabilize and solidify wastes exist, among them the Ecofix process which employs low cost materials and consists of mixing wastes with lime, aluminum hydroxide, and silica. To evaluate the long-term behavior of solidified/stabilized (S/S) samples, their alteration under saturated conditions was studied in a water extractor, a Soxhlet-like device, used to follow the weathering of rocks. Kinetic measurements have shown that the release of Fe, Pb, Cd, Cr, and Cu was very slow, indicating a strong retention of these elements by the S/S materials prepared by the Ecofix process. To elucidate the mechanisms of retention of the trace metals, the mineral phases that existed in the S/S samples throughout and at the end of the extraction runs were studied by X-ray diffraction and by infrared and nuclear magnetic resonance spectroscopies. Scanning electron microscopic (SEM) examinations and electron microprobe analyses of the S/S samples were also performed at different stages of weathering. These observations revealed that assorted calcium silicate hydrates (C−S−H) were the predominant phases in the S/S preparations and that gradual alterations occurred in the structure of the investigated materials. The overall Ca/Si ratio of the C−S−H phases decreased as the enhanced alteration progressed. Although trace metals in oxide, hydroxide, and carbonate forms were found in the S/S materials, the bulk of the trace metals was incorporated in the matrix of the C−S−H phases.
- 21 January 2004
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 38 (5) , 1383-1398
Retention of Trace Metals by Solidified/Stabilized Wastes: Assessment of Long-Term Metal Release
Toxic elements found in wastes may have a negative impact on the environment, especially through the contamination of groundwater and plants. To reduce their mobility and availability, French regulations mandate the solidification and stabilization of toxic wastes. Many methods to stabilize and solidify wastes exist, among them the Ecofix process which employs low cost materials and consists of mixing wastes with lime, aluminum hydroxide, and silica. To evaluate the long-term behavior of solidified/stabilized (S/S) samples, their alteration under saturated conditions was studied in a water extractor, a Soxhlet-like device, used to follow the weathering of rocks. Kinetic measurements have shown that the release of Fe, Pb, Cd, Cr, and Cu was very slow, indicating a strong retention of these elements by the S/S materials prepared by the Ecofix process. To elucidate the mechanisms of retention of the trace metals, the mineral phases that existed in the S/S samples throughout and at the end of the extraction runs were studied by X-ray diffraction and by infrared and nuclear magnetic resonance spectroscopies. Scanning electron microscopic (SEM) examinations and electron microprobe analyses of the S/S samples were also performed at different stages of weathering. These observations revealed that assorted calcium silicate hydrates (C−S−H) were the predominant phases in the S/S preparations and that gradual alterations occurred in the structure of the investigated materials. The overall Ca/Si ratio of the C−S−H phases decreased as the enhanced alteration progressed. Although trace metals in oxide, hydroxide, and carbonate forms were found in the S/S materials, the bulk of the trace metals was incorporated in the matrix of the C−S−H phases.