PBP. V. Balasubramanyam

P. V. Balasubramanyam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


P. V. Balasubramanyam has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of 2.5MVAR STATCOM for arc furnace applications

    by S. EswaraRao, Bishnu Prasad Muni, Prashant Jain, C P V Krishna Reddy, P V Balasubramanyam

    High power industrial loads such as, electric arc furnaces (EAF), variable frequency drives (VFD) are the main sources of power quality problems in steel plants. EAFs present rapidly varying, largely unbalanced, polluting and poor power factor load to power distribution network at the point of common coupling (PCC). Rapidly changing active and reactive power demand, causes voltage drop across the impedance of the ac system which in turn results in voltage fluctuations and poor power factor at PCC. The fast dynamic response of the Static Synchronous Compensator (STATCOM) makes it an ideal choice for solving power quality problems caused by EAF. Neutral Point Clamped (NPC) Voltage Source Converter (VSC) based 2.5 MVAR STATCOM has been developed and installed at foundry shop, Bhilai Steel Plant for mitigation of voltage flicker caused by EAF and compensation of reactive power drawn by EAF. This paper presents the development and performance of the developed STATCOM with the recorded data.


  • Development of 2.5MVAR STATCOM for arc furnace applications

    by S. EswaraRao, Bishnu Prasad Muni, Prashant Jain, Cpv Krishna Reddy, Pv Balasubramanyam

    High power industrial loads such as, electric arc furnaces (EAF), variable frequency drives (VFD) are the main sources of power quality problems in steel plants. EAFs present rapidly varying, largely unbalanced, polluting and poor power factor load to power distribution network at the point of common coupling (PCC). Rapidly changing active and reactive power demand, causes voltage drop across the impedance of the ac system which in turn results in voltage fluctuations and poor power factor at PCC. The fast dynamic response of the Static Synchronous Compensator (STATCOM) makes it an ideal choice for solving power quality problems caused by EAF. Neutral Point Clamped (NPC) Voltage Source Converter (VSC) based 2.5 MVAR STATCOM has been developed and installed at foundry shop, Bhilai Steel Plant for mitigation of voltage flicker caused by EAF and compensation of reactive power drawn by EAF. This paper presents the development and performance of the developed STATCOM with the recorded data.


  • Open Access

    Study on Recovery Performance of High Tc Superconducting Tapes for Resistive Type Superconducting Fault Current Limiter Applications

    by Soumen Kar, Sandeep Kulkarni, Manglesh Dixit, Kuwar Pal Singh, Alok Gupta, P.V. Balasubramanyam, S.K. Sarangi, V.V. Rao


  • Voltage control of variable speed SEIG with Z-Source inverter

    by S Ravi Kiran, S.P Singh, P.V. Balasubramanyam

    This paper presents a voltage control method for a three-phase Self Excited Induction Generator (SEIG) with Z-Source inverter. A Z-Source inverter with unified control technique is proposed which can boost the voltage and generate the desired output voltage efficiently when the low voltage is available at generator terminals due to low speed operation of generator. And also when the speed of generator is high giving higher voltages the inverter operates as a traditional voltage source inverter to buck the voltage. Thus proposed system is capable of both boosting and bucking voltage. Thus making system suitable for wind turbine distributed Generation system. In unified control technique a unified voltage vector is used which is composed of both traditional voltage vector and unique boost factor which provides fast dynamic response to maintain constant output voltage of inverter in variable speed operation of SEIG.


  • Development of 440-V 800-A Resistive-Type Modular Superconducting Fault Current Limiter With YBCO Tapes

    by Manglesh Dixit, Sunil Kedia, Sandeep Kulkarni, Shubhangi Patil, Lalichan Andrews, Alok Gupta, P. V. Balasubramanyam

    CG Global R&D is developing a resistive-type superconducting fault current limiter (SFCL) under the Ministry of Power, National Perspective Plan for R&D in Indian Power Sector. A resistive-type 440-V 800-A single-phase SFCL is developed using YBCO tape in stage I of the project, and an 11-kV 1250-A three-phase SFCL will be developed in stage II. The 440-V 800-A SFCL is assembled with seven parallel modules. Each module has series-connected YBCO tapes to accommodate the design length. The SFCL is tested at 77 K for continuous current of few hours, fault currents at low voltage, and fault currents at 440 V up to 100 ms (5 cycles). The evaluated data will be used to develop an 11-kV 1250-A three-phase SFCL in stage II.


  • Digital protection of transmission lines using a new phasor measurement approach

    by Malhar Padhee, P. K. Dash, J. P. Patra, P. V. Balasubramanyam

    The paper presents an improved Gauss-Newton approach for fast and accurate estimation of voltage and current phasors, which are a prerequisite for distance relaying applications. The improved Gauss-Newton method has an advantage that the fundamental voltage and current phasors are estimated accurately even in the presence of decaying dc, harmonic components and measurement noise. The proposed algorithm has been applied for the protection of a transmission line fed from one end both with and without transformer saturation; the ensuing R-X trajectories clearly reveal very fast operation. Hence, very accurate fault location estimation can be made by utilizing this new approach.

  • S-transform based spectral energy feature space for fault location approximation

    by K. R. Krishnanand, P. V. Balasubramanyam, S. K. Swain, P. K. Dash

    A methodology for fault location calculation of transmission lines using S-transform based spectral energy feature space and multi-layer perceptron is presented in this paper. S-transform being capable of providing the time domain and frequency domain information at the same time, gives remarkable insight in to the protection issues of a transmission line. The energy distributions of the faulted current waveforms are used to compute the fault location using the pattern recognition approach. This paper proposes the fault detection and classification through S-transform energy by using synchronized measurement of the differential and average energy of current signals. The S-transform energy calculations are used for fault location using a neural network.


  • Selection Criteria of High ${\rm T}_{\rm c}$ Superconducting Tapes for Superconducting Fault Current Limiter Applications

    by Soumen Kar, Sandeep Kulkarni, Manglesh Dixit, Kuwar Pal Singh, Alok Gupta, P. V. Balasubramanyam, S. K. Sarangi, V. V. Rao

    To establish a selection criterion of high temperature superconducting (HTS) tapes for their possible application in superconducting fault current limiters (SFCLs), it is required to have high critical current density, high `n' value, high normal state resistance, low AC losses, large heat transfer area, high thermal diffusivity and quick recovery against thermal instabilities for the HTS tapes. At present HTS tapes are categorized into two types namely Bi2223 based 1st generation (1G) HTS tape and YBCO based 2nd generation (2G) coated conductors (CCs). These 1G and 2G tapes are composite tapes. Hence, it is required to know their averaged material properties that can affect the performance of the SFCL during normal state operation. This paper deals with these issues along with DC characterization results to establish selection criteria of HTS tapes for SFCL applications.


  • Robust power system stabiliser design using minimax control approach: Validation using Real-time Digital Simulation

    by Germane Xavier Athanasius, Hemanshu R. Pota, Pv Bala Subramanyam, Valery Ugrinovskii

    This paper addresses the problem of designing decentralized power system stabilisers for interconnected power systems using robust output feedback minimax control techniques. We have considered the problem of designing a robust controller for a generator connected to a multi-machine grid system. To make the controller robust against parameter variations around the operating point, system parameter variations, due to load changes, are represented using integral quadratic constraints (IQCs). The interconnection effects from other machines in the system and local uncertainties are also included in the controller design using IQCs. Generator speed is used as the output feedback variable for the controller, due to the fact that other generator states are difficult to measure. The controller design is validated using a real-time digital simulation (RTDS) facility for a four-machine two-area test system.


  • Analysis of supplementary controls in damping subsynchronous oscillations

    by P.V. Balasubramanyam, A.S.R. Murty, B.N. Sarkar

    Analysis and damping of torsional oscillations through thyristor controlled reactors (TCR) is presented in this paper. The reactive power control is achieved through TCR at the machine terminals. Generator speed signal is used as the auxiliary signal and the terminal voltage feedback signal as the main control signal for the TCR. The following control strategies for auxiliary control of TCRs have been analysed: (1) analysis of basic system without damping controls; (2) proportional control; (3) proportional control with filter; (4) proportional derivative control filter; and (5) proportional plus integral plus derivative control with filter. The main objective of this paper is to discuss the performance of different control strategies for damping torsional oscillations when a generator is connected to an infinite bus via a double circuit 400 kV transmission line, in which one circuit is series compensated. This configuration is similar to IEEE benchmark two model.