Neeraj Kumar Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Neeraj Kumar Sharma has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Saikat Chakrabarti
Indian Institute of Technology Kanpur
6 shared publications Deepali Yadav
3 shared publicationsAnkush Sharma
2 shared publications- Ankush Sharma
Indian Institute of Technology Kanpur
2 shared publications Balaji Venkateswaran
1 shared publicationBalaji Venkateswaran V
1 shared publication
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (5) , 2206-2217
Dynamic Thermal Line Rating Estimation of Power System
Dynamic thermal line rating (DTLR) enhances the power transfer capability of thermally limited overhead lines by accounting for real-time environmental and operational conditions. Key influencing factors include solar irradiance, ambient temperature, line current, wind velocity (wind speed with angular direction), and conductor temperature. While some parameters are readily available via online sources or existing sensors, accurate DTLR estimation typically requires wind and conductor temperature data, which often demand additional instrumentation and cost. This paper proposes a cost-effective methodology for short transmission lines that eliminates the need for direct wind and conductor temperature measurements. Instead, it estimates the real-time line resistance using data from emulated SCADA or PMU systems, from which the conductor temperature is subsequently estimated. Using this, along with accessible environmental data, the method estimates wind velocity effects and estimates an optimal DTLR. This method is well suited for regions exhibiting relatively uniform weather conditions, particularly flat terrains. Validation is performed using IEEE Standard 738-2012, with DIgSILENT PowerFactory used to emulate real-time data from SCADA and PMU, and DTLR estimation simulated in MATLAB.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (5) , 2206-2217
Dynamic Thermal Line Rating Estimation of Power System
Dynamic thermal line rating (DTLR) enhances the power transfer capability of thermally limited overhead lines by accounting for real-time environmental and operational conditions. Key influencing factors include solar irradiance, ambient temperature, line current, wind velocity (wind speed with angular direction), and conductor temperature. While some parameters are readily available via online sources or existing sensors, accurate DTLR estimation typically requires wind and conductor temperature data, which often demand additional instrumentation and cost. This paper proposes a cost-effective methodology for short transmission lines that eliminates the need for direct wind and conductor temperature measurements. Instead, it estimates the real-time line resistance using data from emulated SCADA or PMU systems, from which the conductor temperature is subsequently estimated. Using this, along with accessible environmental data, the method estimates wind velocity effects and estimates an optimal DTLR. This method is well suited for regions exhibiting relatively uniform weather conditions, particularly flat terrains. Validation is performed using IEEE Standard 738-2012, with DIgSILENT PowerFactory used to emulate real-time data from SCADA and PMU, and DTLR estimation simulated in MATLAB.
- 26 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Enhancement of power system state estimation using dynamic thermal line rating parameters
- 26 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Enhancement of power system state estimation using dynamic thermal line rating parameters
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (12) , 9515-9525
Angle Reference Based Three-Phase State Estimation of Power Distribution Systems
Power distribution systems require three-phase state estimation due to their inherently unbalanced nature. Identifying a balanced reference bus is essential for conducting three-phase state estimation. However, such a reference bus is rarely available in distribution systems. Existing distribution system state estimation (DSSE) methodologies often randomly select a bus for this purpose, leading to biased results, while those based on a single angular reference face convergence issues. To address these challenges, this article introduces a novel method designed to mitigate the limitations associated with the reference bus in DSSE. This method is executed in two stages: first, it obtains the exact phase angles of the reference bus using local measurements available at that bus; second, it utilizes these precise phase angles to estimate the states of the distribution system. The efficacy of the proposed method is demonstrated through validation on the IEEE 13-node feeder, IEEE 37-node feeder, and IEEE 123-node feeder.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (12) , 9515-9525
Angle Reference Based Three-Phase State Estimation of Power Distribution Systems
Power distribution systems require three-phase state estimation due to their inherently unbalanced nature. Identifying a balanced reference bus is essential for conducting three-phase state estimation. However, such a reference bus is rarely available in distribution systems. Existing distribution system state estimation (DSSE) methodologies often randomly select a bus for this purpose, leading to biased results, while those based on a single angular reference face convergence issues. To address these challenges, this article introduces a novel method designed to mitigate the limitations associated with the reference bus in DSSE. This method is executed in two stages: first, it obtains the exact phase angles of the reference bus using local measurements available at that bus; second, it utilizes these precise phase angles to estimate the states of the distribution system. The efficacy of the proposed method is demonstrated through validation on the IEEE 13-node feeder, IEEE 37-node feeder, and IEEE 123-node feeder.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 19 (1)
Coordinated State Estimation of Power Transmission and Distribution Systems
This paper introduces a coordinated state estimation (CSE) approach designed to achieve a unique reference solution for both transmission and distribution systems. The CSE framework additionally addresses the challenges related to balanced bus requirements within distribution system state estimation (DSSE). Specifically, the CSE method models a transmission boundary bus as a reference bus for the execution of DSSE. Furthermore, the methodology constructs a consistency check vector based on the estimated variables of the modelled reference bus, thereby ensuring the coherence of the solution for the entire power system. To manage the substantial complexity of the problem, the CSE approach employs a parallel estimation strategy. This paper validates the CSE technique through a comprehensive analysis of different power transmission and distribution system combinations. The study focuses on the IEEE 14‐bus and New England 39‐bus systems as transmission networks, alongside the IEEE 13‐node and 37‐node feeders as distribution networks. Validation is conducted using MATLAB and DIgSILENT PowerFactory software tools.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 19 (1)
Open AccessCoordinated State Estimation of Power Transmission and Distribution Systems
This paper introduces a coordinated state estimation (CSE) approach designed to achieve a unique reference solution for both transmission and distribution systems. The CSE framework additionally addresses the challenges related to balanced bus requirements within distribution system state estimation (DSSE). Specifically, the CSE method models a transmission boundary bus as a reference bus for the execution of DSSE. Furthermore, the methodology constructs a consistency check vector based on the estimated variables of the modelled reference bus, thereby ensuring the coherence of the solution for the entire power system. To manage the substantial complexity of the problem, the CSE approach employs a parallel estimation strategy. This paper validates the CSE technique through a comprehensive analysis of different power transmission and distribution system combinations. The study focuses on the IEEE 14‐bus and New England 39‐bus systems as transmission networks, alongside the IEEE 13‐node and 37‐node feeders as distribution networks. Validation is conducted using MATLAB and DIgSILENT PowerFactory software tools.
- 30 September 2019
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 8 (11) , 4196-4203
Experimental Verification of Reconfiguration Techniques Applied For Partial Shading on Solar PV
Energy is the one of the basic requirements for sustained economic growth. To meet the growing requirement of energy, and to reduce the CO2 emission, many countries have chosen to meet its energy demand through renewable energy resources for sustainable development. Most popular renewable energy resources are solar and wind; due to the technological advancement in solar technology and its demand in the market made solar panels comparatively cheaper. One of the popular ways to extract solar power is installing solar rooftop. The main factor, which affects the performance of solar rooftop PV system, is power mismatch due to shading. In the literature, many reconfiguration methods have proposed based on electrical interconnections and physical location of the solar cell/modules. In this paper, physical-location based techniques are modified as electrical interconnection techniques and its performance is compared through experimentation at various shading patterns.
- 30 September 2019
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 8 (11) , 4196-4203
Experimental Verification of Reconfiguration Techniques Applied For Partial Shading on Solar PV
Energy is the one of the basic requirements for sustained economic growth. To meet the growing requirement of energy, and to reduce the CO2 emission, many countries have chosen to meet its energy demand through renewable energy resources for sustainable development. Most popular renewable energy resources are solar and wind; due to the technological advancement in solar technology and its demand in the market made solar panels comparatively cheaper. One of the popular ways to extract solar power is installing solar rooftop. The main factor, which affects the performance of solar rooftop PV system, is power mismatch due to shading. In the literature, many reconfiguration methods have proposed based on electrical interconnections and physical location of the solar cell/modules. In this paper, physical-location based techniques are modified as electrical interconnection techniques and its performance is compared through experimentation at various shading patterns.
- 11 March 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.6) , 199
State Estimation of Power System Embedded with FACTS devices and PMUs
In recent days, the power system is incorporated with Flexible AC Transmission System (FACTS) devices for compensation of reactive power to maintain the stability of the system. The stability of the system is highly dependent on the state variables which are the outcomes of a state estimator in the power system. To improve the efficiency of a state estimator, high precision measuring devices such as Phasor Measurement Units (PMUs) are installed in the power system. Hence a state estimator embedded with these compensatory devices and PMUs is necessary for estimation of state variables. The present work has been carried out in three steps. Step 1: Considering the cost of PMUs and the availability of the communication network in the particular location, PMUs are optimally placed in the nodes of the system so that all critical measurements are transmuted into redundant ones using differential evolution (DE) algorithm to perform observability analysis. Step 2: A hybrid state estimation is performed by including the mathematical model of FACTS devices and PMUs. Step 3: It is shown that by installing optimal number of PMUs at desired location, multiple bad data detection and identification capability of residual method is considerably improved. Lastly, numerical simulation with standard IEEE 14 bus system, IEEE 118 bus system and a practical 246 bus system of northern region power grid (NRPG) is presented to confirm the effectiveness of the proposed approach in assessing the estimation of the system state variables.
- 11 March 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2.6) , 199
State Estimation of Power System Embedded with FACTS devices and PMUs
In recent days, the power system is incorporated with Flexible AC Transmission System (FACTS) devices for compensation of reactive power to maintain the stability of the system. The stability of the system is highly dependent on the state variables which are the outcomes of a state estimator in the power system. To improve the efficiency of a state estimator, high precision measuring devices such as Phasor Measurement Units (PMUs) are installed in the power system. Hence a state estimator embedded with these compensatory devices and PMUs is necessary for estimation of state variables. The present work has been carried out in three steps. Step 1: Considering the cost of PMUs and the availability of the communication network in the particular location, PMUs are optimally placed in the nodes of the system so that all critical measurements are transmuted into redundant ones using differential evolution (DE) algorithm to perform observability analysis. Step 2: A hybrid state estimation is performed by including the mathematical model of FACTS devices and PMUs. Step 3: It is shown that by installing optimal number of PMUs at desired location, multiple bad data detection and identification capability of residual method is considerably improved. Lastly, numerical simulation with standard IEEE 14 bus system, IEEE 118 bus system and a practical 246 bus system of northern region power grid (NRPG) is presented to confirm the effectiveness of the proposed approach in assessing the estimation of the system state variables.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 164-172
A Novel Shunt Hybrid Active Filter To Eliminate Dominant Current Harmonics Under Realistic Utility Conditions
The following topics are dealt with: control system synthesis; image segmentation; medical image processing; switching convertors; invertors; brain; entropy; nonlinear control systems; closed loop systems; power convertors.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 164-172
A Novel Shunt Hybrid Active Filter To Eliminate Dominant Current Harmonics Under Realistic Utility Conditions
The following topics are dealt with: control system synthesis; image segmentation; medical image processing; switching convertors; invertors; brain; entropy; nonlinear control systems; closed loop systems; power convertors.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An optimization based method for topology error detection for state estimation
Topology processing is a vital function of a power system state estimator. Detection, identification, and processing of the topology error are pre-requisites for successful execution of the state estimator. The conventional measurement residual based topology error processing methods may fail under certain measurement configurations and system topologies. This paper proposes an optimization based technique for topology error detection of power systems in presence of hybrid measurements. The proposed technique is successfully implemented on a number of test systems.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An optimization based method for topology error detection for state estimation
Topology processing is a vital function of a power system state estimator. Detection, identification, and processing of the topology error are pre-requisites for successful execution of the state estimator. The conventional measurement residual based topology error processing methods may fail under certain measurement configurations and system topologies. This paper proposes an optimization based technique for topology error detection of power systems in presence of hybrid measurements. The proposed technique is successfully implemented on a number of test systems.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 364-368
Observability analysis of power systems in the presence of hybrid measurements
Phasor measurement units (PMUs) are increasingly being used in modern power systems due to their high reporting rate and accuracy. The majority of the measurement devices in the existing power systems, however, are conventional asynchronous measurements. State-of-the-art state estimation algorithms are therefore required to include the hybrid set of measurements. Observability of the system with the given set of measurements is a pre-requisite of any state estimator. This paper proposes a numerical algorithm for observability analysis of power systems having hybrid measurements. The proposed method is demonstrated with the help of a number of test systems.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 364-368
Observability analysis of power systems in the presence of hybrid measurements
Phasor measurement units (PMUs) are increasingly being used in modern power systems due to their high reporting rate and accuracy. The majority of the measurement devices in the existing power systems, however, are conventional asynchronous measurements. State-of-the-art state estimation algorithms are therefore required to include the hybrid set of measurements. Observability of the system with the given set of measurements is a pre-requisite of any state estimator. This paper proposes a numerical algorithm for observability analysis of power systems having hybrid measurements. The proposed method is demonstrated with the help of a number of test systems.