CWCornelia Beatrix Wunderer

Cornelia Beatrix Wunderer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cornelia Beatrix Wunderer has a total of 998 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Second-generation Percival sensor and system for upgraded soft X-ray imaging at FELs and synchrotrons

    by C.B. Wunderer, M. Hajheidari, A. Marras, Th. Wendt, F. Anders, J. Correa, M. Dahlgruen, J. Gebert, T. Hirono, H. Hirsemann, et al.

    PERCIVAL, “pixellated energy-resolving CMOS imager versatile and large”, is a 2-megapixel soft X-ray imager developed for use at FELs and modern-day synchrotrons. A combination of capabilities is necessary to meet the scientific needs: a large, uninterrupted imaging area with small pixels, high dynamic range, high frame rate, and soft X-ray suitable entrance window to the sensor. A single PERCIVAL sensor offers over 4 cm × 4 cm uninterrupted imaging area (1408 × 1484 pixels of 27 × 27 μm 2 ). Three auto-adapting gains (per pixel per image) provide the large dynamic range from 13 e - noise to over 3 Me - signal. The sensor is designed for up to 300 Hz frame rate, and can be operated faster in ROI mode. The first generation of the sensor was hampered by severe crosstalk preventing parallel operation of ADC, streamout, and pixel switches and by non-uniformity of baselines over the sensor. A revised “respin” sensor addresses these issues at the root — and good noise performance at higher frame rates as well as a more uniform baseline can now be provided to users. The first generation DAQ system — still based on existing Virtex5 hardware — had limitations that ultimately prevented handling the fast data rates from a Percival running at full speed, or other complexities such as ROI operation. A complete overhaul of the percival-specific DAQ components (FPGA with periphery and firmware) today enables acquisition at envisioned frame rates and in ROI mode. This paper summarizes first laboratory results from the respin sensors in combination with the new DAQ hardware and firmware.

  • Open Access

    Computational microscopy with the PERCIVAL detector system at TwinMic beamline

    by Francesco Guzzi, Alessandra Gianoncelli, Luigi Stebel, Dario Giuressi, Giuseppe Cautero, Roberto Borghes, Iztok Gregori, Fulvio Billè, Martin Scarcia, Valentina Bonanni, et al.

    PERCIVAL is a novel soft X-ray detection system designed for the needs of modern microscopy. By integrating it into the TwinMic end-station at Elettra Sincrotrone Trieste, we conducted an exploratory computational microscopy experiment on biological samples, aiming at evaluating the entire system in a real use-case scenario. We present the methodology to convert the RAW data and our high-resolution image reconstructions.

  • Open Access

    The PERCIVAL detector: first user experiments

    by J. Correa, M. Mehrjoo, R. Battistelli, F. Lehmkühler, A. Marras, C. B. Wunderer, T. Hirono, V. Felk, F. Krivan, S. Lange, et al.

    The PERCIVAL detector is a CMOS imager designed for the soft X-ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ptychography at a free-electron laser, holographic imaging at a storage ring and preliminary tests on X-ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X-ray science.


  • Open Access

    Megahertz-rate ultrafast X-ray scattering and holographic imaging at the European XFEL

    by Nanna Zhou Hagström, Michael Schneider, Nico Kerber, Alexander Yaroslavtsev, Erick Burgos Parra, Marijan Beg, Martin Lang, Christian M. Günther, Boris Seng, Fabian Kammerbauer, et al.

    The advent of X-ray free-electron lasers (XFELs) has revolutionized fundamental science, from atomic to condensed matter physics, from chemistry to biology, giving researchers access to X-rays with unprecedented brightness, coherence and pulse duration. All XFEL facilities built until recently provided X-ray pulses at a relatively low repetition rate, with limited data statistics. Here, results from the first megahertz-repetition-rate X-ray scattering experiments at the Spectroscopy and Coherent Scattering (SCS) instrument of the European XFEL are presented. The experimental capabilities that the SCS instrument offers, resulting from the operation at megahertz repetition rates and the availability of the novel DSSC 2D imaging detector, are illustrated. Time-resolved magnetic X-ray scattering and holographic imaging experiments in solid state samples were chosen as representative, providing an ideal test-bed for operation at megahertz rates. Our results are relevant and applicable to any other non-destructive XFEL experiments in the soft X-ray range.


  • Open Access

    Characterization of the Percival detector with soft X-rays

    by Alessandro Marras, Jonathan Correa, Sabine Lange, Vahagn Vardanyan, Tim Gerhardt, Manuela Kuhn, Frantisek Krivan, Igor Shevyakov, Manfred Zimmer, Moritz Hoesch, et al.

    In this paper the back-side-illuminated Percival 2-Megapixel (P2M) detector is presented, along with its characterization by means of optical and X-ray photons. For the first time, the response of the system to soft X-rays (250 eV to 1 keV) is presented. The main performance parameters of the first detector are measured, assessing the capabilities in terms of noise, dynamic range and single-photon discrimination capability. Present limitations and coming improvements are discussed.


  • Percival: A soft x-ray imager for synchrotron rings and free electron lasers

    by Alessandro Marras, Cornelia Wunderer, Jonathan Correa, Benjamin Boitrelle, Peter Goettlicher, Manuela Kuhn, Frantisek Krivan, Sabine Lange, Frank Okrent, Igor Shevyakov, et al.

    In this paper, we are presenting the Percival detector, a monolithic CMOS Imager for detection of soft x-rays in Synchrotron Rings and Free Electron Lasers. The imager consists in a 2D array of many (2M) small (27um pitch) pixels, without dead or blind zones in the imaging area. The imager achieves low noise and high dynamic range by means of an adaptive-gain in-pixel circuitry, that has been validated on prototypes. The imager features on-chip Analogue-to-Digital conversion to 12+1 bits, and has a readout speed which is compatible with most of Free Electron Laser Facilities. For direct detection of low-energy x-rays, the imager is back-illuminated and post-processed to achieve 100% fill factor.


  • The Percival 2-Megapixel monolithic active pixel imager

    by C.B. Wunderer, J. Correa, A. Marras, S. Aplin, B. Boitrelle, P. Goettlicher, F. Krivan, M. Kuhn, S. Lange, M. Niemann, et al.


  • On the Charge Collection Efficiency of the PERCIVAL Detector

    by J. Correa, A. Marras, C.B. Wunderer, P. Göttlicher, S. Lange, S. Reza, I. Shevyakov, M. Tennert, M. Niemann, H. Hirsemann, et al.

    The PERCIVAL soft X-ray imager is being developed by DESY, RAL, Elettra, DLS, and PAL to address the challenges at high brilliance Light Sources such as new-generation Synchrotrons and Free Electron Lasers. Typical requirements for detector systems at these sources are high frame rates, large dynamic range, single-photon counting capability with low probability of false positives, high quantum efficiency, and (multi)-mega-pixel arrangements. PERCIVAL is a monolithic active pixel sensor, based on CMOS technology. It is designed for the soft X-ray regime and, therefore, it is post-processed in order to achieve high quantum efficiency in its primary energy range (250 eV to 1 keV) . This work will report on the latest experimental results on charge collection efficiency obtained for multiple back-side-illuminated test sensors during two campaigns, at the P04 beam-line at PETRA III, and the CiPo beam-line at Elettra, spanning most of the primary energy range as well as testing the performance for photon-energies below 250 eV . In addition, XPS surface analysis was used to cross-check the obtained results.


  • Report on recent results of the PERCIVAL soft X-ray imager

    by A. Khromova, G. Cautero, D. Giuressi, R. Menk, G. Pinaroli, L. Stebel, J. Correa, A. Marras, C.B. Wunderer, S. Lange, et al.

    The PERCIVAL (Pixelated Energy Resolving CMOS Imager, Versatile And Large) soft X-ray 2D imaging detector is based on stitched, wafer-scale sensors possessing a thick epi-layer, which together with back-thinning and back-side illumination yields elevated quantum efficiency in the photon energy range of 125–1000 eV. Main application fields of PERCIVAL are foreseen in photon science with FELs and synchrotron radiation. This requires high dynamic range up to 105 ph @ 250 eV paired with single photon sensitivity with high confidence at moderate frame rates in the range of 10–120 Hz. These figures imply the availability of dynamic gain switching on a pixel-by-pixel basis and a highly parallel, low noise analog and digital readout, which has been realized in the PERCIVAL sensor layout. Different aspects of the detector performance have been assessed using prototype sensors with different pixel and ADC types. This work will report on the recent test results performed on the newest chip prototypes with the improved pixel and ADC architecture. For the target frame rates in the 10–120 Hz range an average noise floor of 14e− has been determined, indicating the ability of detecting single photons with energies above 250 eV. Owing to the successfully implemented adaptive 3-stage multiple-gain switching, the integrated charge level exceeds 4 106 e− or 57000 X-ray photons at 250 eV per frame at 120 Hz. For all gains the noise level remains below the Poisson limit also in high-flux conditions. Additionally, a short overview over the updates on an oncoming 2 Mpixel (P2M) detector system (expected at the end of 2016) will be reported.


  • Open Access

    Single-shot diffraction data from the Mimivirus particle using an X-ray free-electron laser

    by Tomas Ekeberg, Martin Svenda, M. Marvin Seibert, Chantal Abergel, Filipe R.N.C. Maia, Virginie Seltzer, Daniel P. DePonte, Andrew Aquila, Jakob Andreasson, Bianca Iwan, et al.

    Free-electron lasers (FEL) hold the potential to revolutionize structural biology by producing X-ray pules short enough to outrun radiation damage, thus allowing imaging of biological samples without the limitation from radiation damage. Thus, a major part of the scientific case for the first FELs was three-dimensional (3D) reconstruction of non-crystalline biological objects. In a recent publication we demonstrated the first 3D reconstruction of a biological object from an X-ray FEL using this technique. The sample was the giant Mimivirus, which is one of the largest known viruses with a diameter of 450 nm. Here we present the dataset used for this successful reconstruction. Data-analysis methods for single-particle imaging at FELs are undergoing heavy development but data collection relies on very limited time available through a highly competitive proposal process. This dataset provides experimental data to the entire community and could boost algorithm development and provide a benchmark dataset for new algorithms.