Anders Austegard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anders Austegard has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Han Deng
SINTEF Energy Research, Sem Sælandsvei 11, NO-7465 Trondheim, Norway
4 shared publications - Svend Tollak Munkejord
SINTEF Energy Research, Trondheim, Norway
4 shared publications - Alexandra Metallinou Log
SINTEF Energy Research
3 shared publications Bahareh Khosravi
Norwegian Univ Sci & Technol, Trondheim, Norway
2 shared publicationsH G Jacob Stang
SINTEF Energy Res, Trondheim, Norway
2 shared publications- H.G. Jacob Stang
SINTEF Energy Research, NO-7465 Trondheim, Norway
2 shared publications
Latest Publications
- Open Access
- 11 September 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 306
Experiments and modelling of CO2 vessel depressurization: Flash boiling, heat transfer and critical flow through nozzles
- 11 September 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 306
Open AccessExperiments and modelling of CO2 vessel depressurization: Flash boiling, heat transfer and critical flow through nozzles
- Open Access
- 15 July 2025
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 192
Temperature response during rapid depressurization of CO 2 in a pipe: Experiments and fluid-dynamics modelling
- 15 July 2025
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 192
Open AccessTemperature response during rapid depressurization of CO 2 in a pipe: Experiments and fluid-dynamics modelling
- Open Access
- 2 March 2025
- Published by Elsevier in Chemical Engineering Science
- Vol. 309
Decompression-induced condensation of carbon dioxide: Experiments, and prediction of the supercooling limit using classical nucleation theory
- 2 March 2025
- Published by Elsevier in Chemical Engineering Science
- Vol. 309
Open AccessDecompression-induced condensation of carbon dioxide: Experiments, and prediction of the supercooling limit using classical nucleation theory
- Open Access
- 22 May 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035009
Two-capillary viscometer for temperatures and pressures relevant to CO2 capture, transport, and storage—operation and improved analysis at high pressure
High-pressure viscosity measurements are crucial for understanding CO2 transport and storage because CO2 is often transported as a supercritical fluid, at a high pressure and temperature above its critical point. In this study, we extended the operational range of our new two-capillary viscometer to handle pressures up to 20 MPa, focusing on the behaviour of CO2 at temperatures around 300 K. The analysis model is based on the low-pressure principle, which relied on virial descriptions of density and viscosity, proved inadequate under these conditions. Therefore, we introduced a modified hydrodynamic model as a function of density that is suitable for viscosity measurements at high pressure and liquid states. The modified model bypasses the need for a density virial correction. We conducted initial viscosity tests on pure CO2 at five isotherms: 280.01 K, 298.15 K, 300.01 K, 323.15 K, and 348.15 K to validate the performance of the new two capillary viscometer and the modified model at high pressures. The experimental viscosities agreed with the model predictions and comparable within the estimated uncertainty of the data. In addition, we thoroughly explained the calibrations and the analysis of uncertainty estimation. The uncertainty analysis showed a maximum extended combined uncertainty of 1.3% (k = 2) within all thermodynamic states—gas, liquid, and close to the critical region.
- 22 May 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035009
Open AccessTwo-capillary viscometer for temperatures and pressures relevant to CO2 capture, transport, and storage—operation and improved analysis at high pressure
High-pressure viscosity measurements are crucial for understanding CO2 transport and storage because CO2 is often transported as a supercritical fluid, at a high pressure and temperature above its critical point. In this study, we extended the operational range of our new two-capillary viscometer to handle pressures up to 20 MPa, focusing on the behaviour of CO2 at temperatures around 300 K. The analysis model is based on the low-pressure principle, which relied on virial descriptions of density and viscosity, proved inadequate under these conditions. Therefore, we introduced a modified hydrodynamic model as a function of density that is suitable for viscosity measurements at high pressure and liquid states. The modified model bypasses the need for a density virial correction. We conducted initial viscosity tests on pure CO2 at five isotherms: 280.01 K, 298.15 K, 300.01 K, 323.15 K, and 348.15 K to validate the performance of the new two capillary viscometer and the modified model at high pressures. The experimental viscosities agreed with the model predictions and comparable within the estimated uncertainty of the data. In addition, we thoroughly explained the calibrations and the analysis of uncertainty estimation. The uncertainty analysis showed a maximum extended combined uncertainty of 1.3% (k = 2) within all thermodynamic states—gas, liquid, and close to the critical region.
- Open Access
- 20 May 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035008
A two-capillary viscometer for temperatures up to 473 K and pressures up to 100 MPa—operation and verification at low pressure
In this paper, we described the design and construction of a new two-capillary viscometer with several novel technical solutions for viscosity and density measurements. Our design, which is based on the low-pressure principle, featured numerous improvements in hardware and procedure that allowed the greatly extended range of pressure. The new design adopted a (2 × 2) capillary configuration, utilizing different combinations of four capillaries to enable viscosity measurements with a wide range of flow rates, temperatures, and pressures. The design temperature range is 213 K–473 K, and the pressure range is up to 100 MPa. The viscometer was specifically designed for measuring the viscosity of pure CO2 and CO2-rich mixtures, addressing the scarcity of data in conditions relevant to carbon capture, transport, and storage. Our facility is capable of viscosity measurements in different thermodynamic states; gaseous, liquid, supercritical, and critical regions. A commercial densimeter is integrated to measure density under the same temperatures and pressures. We aimed for a total uncertainty target of better than 0.03%. The performance of the viscometer was validated by measurements with pure CO2 at 298.15 K and zero density. We observed a deviation of less than 0.03% between the reference viscosity of CO2 of this work and accurately calculated data using ab initio quantum mechanics with a standard uncertainty of 0.2%. Our primary focus in this paper was to provide a detailed description of the design and construction of the apparatus, emphasizing improvements and introducing new solutions to other research groups in constructing similar instruments suitable for low- and high-pressure viscosity measurements with high accuracy.
- 20 May 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035008
Open AccessA two-capillary viscometer for temperatures up to 473 K and pressures up to 100 MPa—operation and verification at low pressure
In this paper, we described the design and construction of a new two-capillary viscometer with several novel technical solutions for viscosity and density measurements. Our design, which is based on the low-pressure principle, featured numerous improvements in hardware and procedure that allowed the greatly extended range of pressure. The new design adopted a (2 × 2) capillary configuration, utilizing different combinations of four capillaries to enable viscosity measurements with a wide range of flow rates, temperatures, and pressures. The design temperature range is 213 K–473 K, and the pressure range is up to 100 MPa. The viscometer was specifically designed for measuring the viscosity of pure CO2 and CO2-rich mixtures, addressing the scarcity of data in conditions relevant to carbon capture, transport, and storage. Our facility is capable of viscosity measurements in different thermodynamic states; gaseous, liquid, supercritical, and critical regions. A commercial densimeter is integrated to measure density under the same temperatures and pressures. We aimed for a total uncertainty target of better than 0.03%. The performance of the viscometer was validated by measurements with pure CO2 at 298.15 K and zero density. We observed a deviation of less than 0.03% between the reference viscosity of CO2 of this work and accurately calculated data using ab initio quantum mechanics with a standard uncertainty of 0.2%. Our primary focus in this paper was to provide a detailed description of the design and construction of the apparatus, emphasizing improvements and introducing new solutions to other research groups in constructing similar instruments suitable for low- and high-pressure viscosity measurements with high accuracy.
- Open Access
- 20 July 2022
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 156
Experiments and modelling of choked flow of CO2 in orifices and nozzles
- 20 July 2022
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 156
Open AccessExperiments and modelling of choked flow of CO2 in orifices and nozzles
- Open Access
- 1 August 2016
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 421, 67-87
Vapor-liquid equilibrium data for the carbon dioxide and oxygen (CO2 + O2) system at the temperatures 218, 233, 253, 273, 288 and 298 K and pressures up to 14 MPa
- 1 August 2016
- Published by Elsevier in Fluid Phase Equilibria
- Vol. 421, 67-87
Open AccessVapor-liquid equilibrium data for the carbon dioxide and oxygen (CO2 + O2) system at the temperatures 218, 233, 253, 273, 288 and 298 K and pressures up to 14 MPa