Yuriy Varetsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuriy Varetsky has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Zbigniew Hanzelka
AGH University of Science and Technology, Krakow, Poland
4 shared publicationsMykhajlo Seheda
Lviv Polytechnic National University,Dept. of Power Engineering & Control Systems,Lviv,Ukraine
3 shared publicationsVolodymyr Konoval
Lviv Polytechnic National University,Dept. of Power Engineering & Control Systems,Lviv,Ukraine
3 shared publicationsZ. Hanzelka
3 shared publications- Michal Gajdzica
Department of Energy and Fuels, AGH University of Kraków, 30-059 Kraków, Poland
2 shared publications Petro Baran
Lviv Polytech Natl Univ, Lvov, Ukraine
2 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (6) , 72-77
IMPACT OF RENEWABLE ENERGY SOURCE REACTIVE POWER ON VOLTAGE FLUCTUATIONS IN THE DISTRIBUTION GRID
The increasing penetration of renewable energy sources (RES), such as solar and wind power plants, into the medium-voltage distribution grids provokes significant concerns about voltage control at local substations. Understanding how RES operation affects the generation and propagation of voltage fluctuations in the distribution grid is important for engineering decisions in the design and operation of RES. The article presents an algorithm for assessing the impact of RES on voltage fluctuations in the medium-voltage grid. The algorithm accounts for controlling RES at a fixed power factor and is implemented in a grid model developed using software for calculating steady-state conditions. The study shows the impact of RES reactive power on the nature of voltage fluctuations in the distribution grid. Based on modelling of a real medium-voltage grid, the feasibility of optimally mitigating voltage fluctuations by selecting the required RES reactive power factor is demonstrated. References 10, figures 4, table 1.
- 6 November 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (6) , 72-77
Open AccessIMPACT OF RENEWABLE ENERGY SOURCE REACTIVE POWER ON VOLTAGE FLUCTUATIONS IN THE DISTRIBUTION GRID
The increasing penetration of renewable energy sources (RES), such as solar and wind power plants, into the medium-voltage distribution grids provokes significant concerns about voltage control at local substations. Understanding how RES operation affects the generation and propagation of voltage fluctuations in the distribution grid is important for engineering decisions in the design and operation of RES. The article presents an algorithm for assessing the impact of RES on voltage fluctuations in the medium-voltage grid. The algorithm accounts for controlling RES at a fixed power factor and is implemented in a grid model developed using software for calculating steady-state conditions. The study shows the impact of RES reactive power on the nature of voltage fluctuations in the distribution grid. Based on modelling of a real medium-voltage grid, the feasibility of optimally mitigating voltage fluctuations by selecting the required RES reactive power factor is demonstrated. References 10, figures 4, table 1.
- Open Access
Studying Voltage Fluctuations in the MV Distribution Grid with a Renewable Energy Source
The increasing penetration of renewable energy sources (RESs), such as photovoltaic and wind power plants, into the medium-voltage distribution grid creates significant concerns regarding voltage control at local substations. Understanding the specifics of the RES operation impact on the phenomenon and propagation of voltage fluctuations in the distribution grid is important for engineering solutions in the RES design and operation practice. The presented article describes an algorithm for estimating the impact of RES on voltage fluctuations in the medium-voltage grid. The algorithm utilises a RES fixed power factor control mode and is implemented in a grid model developed using software for power flow calculations. The study shows the impact of various RES power factor types on the nature of voltage fluctuations in the distribution grid. The RES operation with lagging reactive power factors, as a method of reducing voltage fluctuation magnitudes, results in a more complex nature of voltage fluctuation propagation compared to those with leading power factor. Based on simulations of a true medium-voltage grid, the possibility of optimal mitigation of voltage fluctuations in a grid by selecting the required RES reactive power factor has been proven. The presented model also allows for calculating changes in distribution grid energy losses depending on the RES reactive power factors, ensuring a practical solution of the control strategy.
Open AccessStudying Voltage Fluctuations in the MV Distribution Grid with a Renewable Energy Source
The increasing penetration of renewable energy sources (RESs), such as photovoltaic and wind power plants, into the medium-voltage distribution grid creates significant concerns regarding voltage control at local substations. Understanding the specifics of the RES operation impact on the phenomenon and propagation of voltage fluctuations in the distribution grid is important for engineering solutions in the RES design and operation practice. The presented article describes an algorithm for estimating the impact of RES on voltage fluctuations in the medium-voltage grid. The algorithm utilises a RES fixed power factor control mode and is implemented in a grid model developed using software for power flow calculations. The study shows the impact of various RES power factor types on the nature of voltage fluctuations in the distribution grid. The RES operation with lagging reactive power factors, as a method of reducing voltage fluctuation magnitudes, results in a more complex nature of voltage fluctuation propagation compared to those with leading power factor. Based on simulations of a true medium-voltage grid, the possibility of optimal mitigation of voltage fluctuations in a grid by selecting the required RES reactive power factor has been proven. The presented model also allows for calculating changes in distribution grid energy losses depending on the RES reactive power factors, ensuring a practical solution of the control strategy.
- Open Access
Power Compatibility of Induction Motors in Industrial Grids Containing Synchronous Generators
Starting an induction motor causes voltage sag in the industrial grid that may disturb the operation of grid equipment. Direct-on-line starting is the simplest and most cost-effective method for starting induction motors, but also the most problematic. Large industries often use internal power plants with synchronous generators and starting powerful motors may impact the generator operations. The synchronous generators could be operated with the automatic or manual mode of voltage control. As the operation experience proves, the generator voltage control mode has a significant impact on the transient behaviours in the industrial power grid when starting a large induction motor. This article presents a case study of the synchronous generator tripping within a true medium-voltage industrial grid during the direct-on-line starting of a large induction motor driving the feed water pump. An analysis of the generator protection logs after the tripping showed that the synchronous generator was controlled in manual mode and its protection relay settings were exceeded. The transients initiated by induction motor starts were studied for possible configurations and operating conditions of the grid using a model developed on the Matlab/Simulink Software platform. The simulations have shown that concern about starting large motors in industrial grids containing internal synchronous generators needs to be solved considering the grid configurations and the coordination of generator protection and control devices.
Open AccessPower Compatibility of Induction Motors in Industrial Grids Containing Synchronous Generators
Starting an induction motor causes voltage sag in the industrial grid that may disturb the operation of grid equipment. Direct-on-line starting is the simplest and most cost-effective method for starting induction motors, but also the most problematic. Large industries often use internal power plants with synchronous generators and starting powerful motors may impact the generator operations. The synchronous generators could be operated with the automatic or manual mode of voltage control. As the operation experience proves, the generator voltage control mode has a significant impact on the transient behaviours in the industrial power grid when starting a large induction motor. This article presents a case study of the synchronous generator tripping within a true medium-voltage industrial grid during the direct-on-line starting of a large induction motor driving the feed water pump. An analysis of the generator protection logs after the tripping showed that the synchronous generator was controlled in manual mode and its protection relay settings were exceeded. The transients initiated by induction motor starts were studied for possible configurations and operating conditions of the grid using a model developed on the Matlab/Simulink Software platform. The simulations have shown that concern about starting large motors in industrial grids containing internal synchronous generators needs to be solved considering the grid configurations and the coordination of generator protection and control devices.
- Open Access
Study of Short Circuit and Inrush Current Impact on the Current-Limiting Reactor Operation in an Industrial Grid
Current-limiting reactors are widely used in industrial electrical grids to reduce the current amplitude in the equipment and stabilize the voltage on the busbar during short circuits. Their application is distinguished by high technical and economic efficiency. However, mechanical damage to the reactors has been observed within extensive industrial grids with many induction motors and internal synchronous generators. The article analyses a case study of the reactor damage in the true industrial grid during a short circuit. An analysis of the damaged reactor’s previous operation had shown that there was a weakening of the fastenings in the reactor design, caused by the repeated starting currents of the grid motors and generators. A study of grid transients during short circuits was carried out by Matlab/Simulink software. The simulation results showed that the reactor could be damaged by a critical peak current in an unfavourable combination of the grid configuration and the short circuit location. The results of the study prove that, for industrial networks containing powerful induction motors and internal synchronous generators, the standardized procedure for selecting current-limiting reactors should additionally consider such factors as the localization in the grid, the effect of equipment-starting currents and possible grid configurations.
Open AccessStudy of Short Circuit and Inrush Current Impact on the Current-Limiting Reactor Operation in an Industrial Grid
Current-limiting reactors are widely used in industrial electrical grids to reduce the current amplitude in the equipment and stabilize the voltage on the busbar during short circuits. Their application is distinguished by high technical and economic efficiency. However, mechanical damage to the reactors has been observed within extensive industrial grids with many induction motors and internal synchronous generators. The article analyses a case study of the reactor damage in the true industrial grid during a short circuit. An analysis of the damaged reactor’s previous operation had shown that there was a weakening of the fastenings in the reactor design, caused by the repeated starting currents of the grid motors and generators. A study of grid transients during short circuits was carried out by Matlab/Simulink software. The simulation results showed that the reactor could be damaged by a critical peak current in an unfavourable combination of the grid configuration and the short circuit location. The results of the study prove that, for industrial networks containing powerful induction motors and internal synchronous generators, the standardized procedure for selecting current-limiting reactors should additionally consider such factors as the localization in the grid, the effect of equipment-starting currents and possible grid configurations.
- 9 December 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 180-183
A DRM technique for OLTC testing by the transformer secondary winding DC voltage curve
The dynamic resistance measurement (DRM) method was developed as a supplementary for testing the transformer on-load tap changer (OLTC) and has become popular in recent years. The DRM method has proven to be an effective method for early detecting potential faults in tap changers. The traditional DRM method is based on a DC current being injected through a transformer winding and a tap changer as it moves from the tap to tap. The measurements are carried out in the tested transformer winding under shorted secondary winding. The article presents a new conception of the DRM method, where the OLTC condition is tested by a voltage curve, that is logged on the no-load secondary transformer winding.
- 9 December 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 180-183
A DRM technique for OLTC testing by the transformer secondary winding DC voltage curve
The dynamic resistance measurement (DRM) method was developed as a supplementary for testing the transformer on-load tap changer (OLTC) and has become popular in recent years. The DRM method has proven to be an effective method for early detecting potential faults in tap changers. The traditional DRM method is based on a DC current being injected through a transformer winding and a tap changer as it moves from the tap to tap. The measurements are carried out in the tested transformer winding under shorted secondary winding. The article presents a new conception of the DRM method, where the OLTC condition is tested by a voltage curve, that is logged on the no-load secondary transformer winding.
- 1 May 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 18-21
VPN-based monitoring power system facilities
Stacje systemu elektroenergetycznego są zwykle sterowane z centralnego punktu sterowania za pomocą różnych systemów telemechanicznych. Obsługa operacyjna i sterowanie większości stacji elektroenergetycznych na Ukrainie, które nie posiadają stałego personelu, realizowane są przez operacyjne zespoły terenowe lub zdalnie za pomocą systemów telemechanicznych. Obecnie na całym świecie, a także w nowo budowanych stacjach na Ukrainie, służby operacyjne i dyspozytorskie stosują zdalne monitorowanie na podstawie bezprzewodowych technologii cyfrowych. W artykule przedstawiono wyniki opracowania bezprzewodowej sieci informacyjnej opartej na rejestratorach cyfrowych ALTRA z wykorzystaniem Virtual Private Network klient-serwer technologii. (Monitorowanie obiektów systemu elektroenergetycznego w oparciu na sieć VPN).
- 1 May 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 18-21
VPN-based monitoring power system facilities
Stacje systemu elektroenergetycznego są zwykle sterowane z centralnego punktu sterowania za pomocą różnych systemów telemechanicznych. Obsługa operacyjna i sterowanie większości stacji elektroenergetycznych na Ukrainie, które nie posiadają stałego personelu, realizowane są przez operacyjne zespoły terenowe lub zdalnie za pomocą systemów telemechanicznych. Obecnie na całym świecie, a także w nowo budowanych stacjach na Ukrainie, służby operacyjne i dyspozytorskie stosują zdalne monitorowanie na podstawie bezprzewodowych technologii cyfrowych. W artykule przedstawiono wyniki opracowania bezprzewodowej sieci informacyjnej opartej na rejestratorach cyfrowych ALTRA z wykorzystaniem Virtual Private Network klient-serwer technologii. (Monitorowanie obiektów systemu elektroenergetycznego w oparciu na sieć VPN).
- 2 April 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 209
Study of transient overvoltages on CSI adjustable speed drives under arcing SLGF in the industrial cable grid
- 2 April 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 209
Study of transient overvoltages on CSI adjustable speed drives under arcing SLGF in the industrial cable grid
- Open Access
- 1 January 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1216 (1) , 012009
A mathematical model for the virtual simulator of the power unit electrical part
The mathematical model is developed for a virtual training system (simulator) of the power unit electrical part operators of a thermal (nuclear) power plant. The model is used to simulating the main operating conditions of the power unit electrical part: generator idling, generator synchronization with the power system, excitation shifting from the main unit to the backup one and vice versa, switching in the power unit auxiliary system, and others. Furthermore, it has been implemented modelling some probable emergency conditions within a power plant: incomplete phase switching, damage to standard power unit equipment, synchronous oscillations, asynchronous mode, etc. The model of the power unit electrical part consists of two interacting software units: models of power equipment (turbine, generator with excitation systems, auxiliary system) and models of its control systems, automation, relay protection and signalling. The models are represented by the corresponding algebraic-differential equations that provide real-time mapping power unit processes at the operator’s request. The developed model uses optimal solving algebraic-differential equations to ensure the virtual process behaviour in real-time. In particular, the implicit Euler method is used to solve differential equations, which is stable when simulating processes in significant disturbances, such as accidental disconnection of the unit from the power system, tripping and energizing loads, generator excitation loss, etc.
- 1 January 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1216 (1) , 012009
Open AccessA mathematical model for the virtual simulator of the power unit electrical part
The mathematical model is developed for a virtual training system (simulator) of the power unit electrical part operators of a thermal (nuclear) power plant. The model is used to simulating the main operating conditions of the power unit electrical part: generator idling, generator synchronization with the power system, excitation shifting from the main unit to the backup one and vice versa, switching in the power unit auxiliary system, and others. Furthermore, it has been implemented modelling some probable emergency conditions within a power plant: incomplete phase switching, damage to standard power unit equipment, synchronous oscillations, asynchronous mode, etc. The model of the power unit electrical part consists of two interacting software units: models of power equipment (turbine, generator with excitation systems, auxiliary system) and models of its control systems, automation, relay protection and signalling. The models are represented by the corresponding algebraic-differential equations that provide real-time mapping power unit processes at the operator’s request. The developed model uses optimal solving algebraic-differential equations to ensure the virtual process behaviour in real-time. In particular, the implicit Euler method is used to solve differential equations, which is stable when simulating processes in significant disturbances, such as accidental disconnection of the unit from the power system, tripping and energizing loads, generator excitation loss, etc.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Modelling PV Impact on Energy Loss in Local MV Grid
This paper presents a model to simulate grid energy loss with distributed renewable energy sources based on grid load profile measurements. The characteristics of distribution grid energy loss under actual load profiles and PV generating on the grid are studied. The studies have shown that using the maximum values of the load powers and power outputs of energy sources for calculating energy loss leads to significant errors. Simulating power flow in the example distribution grid using the measured load profiles and time characteristics of PV and HPP outputs is carried out to show their impact on grid power loss in possible exploitative conditions.
- 13 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Modelling PV Impact on Energy Loss in Local MV Grid
This paper presents a model to simulate grid energy loss with distributed renewable energy sources based on grid load profile measurements. The characteristics of distribution grid energy loss under actual load profiles and PV generating on the grid are studied. The studies have shown that using the maximum values of the load powers and power outputs of energy sources for calculating energy loss leads to significant errors. Simulating power flow in the example distribution grid using the measured load profiles and time characteristics of PV and HPP outputs is carried out to show their impact on grid power loss in possible exploitative conditions.
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Method of Evaluating FACTS Device Impact on Voltage Flicker in the EAF Supply System
FACTS devices are widely used in world practice to compensate for voltage fluctuations caused by the operation of an electric arc furnace (EAF) in a power system. The spectrum of voltage fluctuations depends on the design and operating conditions of the EAF, as well as the characteristics of the power supply system. At the design stage, of considerable interest are methods for assessing the predicted decrease in voltage fluctuations when using the selected compensator for the particular EAF. This article presents the principles of modeling the impact of a FACTS device with a known compensation delay on the level of voltage fluctuations in the EAF power supply system. The index ΔU 10 is used as the equivalent level of voltage fluctuations in the compared applications. This method made it possible to use relatively simple models of EAF, FACTS and power supply system to the adequate comparative evaluating the effect of compensation devices on voltage fluctuations in the EAF power system.
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Method of Evaluating FACTS Device Impact on Voltage Flicker in the EAF Supply System
FACTS devices are widely used in world practice to compensate for voltage fluctuations caused by the operation of an electric arc furnace (EAF) in a power system. The spectrum of voltage fluctuations depends on the design and operating conditions of the EAF, as well as the characteristics of the power supply system. At the design stage, of considerable interest are methods for assessing the predicted decrease in voltage fluctuations when using the selected compensator for the particular EAF. This article presents the principles of modeling the impact of a FACTS device with a known compensation delay on the level of voltage fluctuations in the EAF power supply system. The index ΔU 10 is used as the equivalent level of voltage fluctuations in the compared applications. This method made it possible to use relatively simple models of EAF, FACTS and power supply system to the adequate comparative evaluating the effect of compensation devices on voltage fluctuations in the EAF power system.